Search NASA⌕ Search

SEARCH · Search NASA

Results for “gated imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo . Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

47 OTHER INSTRUMENTATION↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self‐gated, dynamic contrast‐enhanced magnetic resonance imaging with compressed‐sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice

High‐risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self‐gated, dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe −/− atherosclerotic mice during natural disease progression. Twenty‐four, 8‐week‐old, female Apoe −/− mice were divided into four groups (n = 6 each) and imaged with self‐gated DCE‐MRI at 4, 8, 12, and 16 weeks after high‐fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high‐fat diet and imaged longitudinally at the same time points. Aortic‐root pseudo‐concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash‐in and washout slopes ( b 1 and b 2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b 2 , indicating contrast agent washout, was significantly higher in mice kept on an high‐fat diet for longer periods of time ( p = 0.03). Group comparison revealed significant differences between mice on a high‐fat diet for 4 versus 16 weeks ( p = 0.03). Macrophage density also significantly increased with diet duration ( p = 0.009). Spearman correlation between b 2 from DCE‐MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE‐MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single‐slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.

Calcagno, Claudia↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Unabsorbed light beamlets for diagnosing coronal density profiles and absorption nonuniformity in direct-drive implosions on OMEGA

Laser light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. The 3ωGOI (gated optical imager) beamlets diagnostic images unabsorbed light from all 60 OMEGA beams as distinct “beamlet” spots for each beam. The implosion can be diagnosed using the position and intensity of these beamlets. The position of each beamlet in the image is determined by refraction and can be used to fit the coronal plasma density profile of the implosion. The inferred plasma density profiles are comparable to profiles predicted by the 1-D hydrodynamics code LILAC but suggest the predictions underestimate the density farther out in the corona. The intensity of light in each spot depends on the cumulative effects of absorption and cross-beam energy transfer along the beamlet’s path through the corona. Furthermore, the measured variation in intensity and polarization between similar spots indicates that absorption during OMEGA implosions is less uniform than previously known.

47 OTHER INSTRUMENTATION↗

Study of Shock Formation Parameters With Drive Conditions in Magnetically Accelerated Plasma Flows

We present experimental data regarding the formation of high-energy-density shocks in magnetically accelerated plasma flows using pulsed power drivers. We quantify the flow velocity and temperature of the ablated plasma using optical Thomson scattering and gated emission imaging across two different generators. We show that, regardless of the drive parameters, the plasma flows show continuous acceleration over centimeter spatial scales, in line with trends in published simulation work. When stationary targets are placed in these supersonic flows, bow-shock formation is observed at all drive parameters in a range of materials. In the higher density flow generated on the 1-MA COBRA generator at Cornell University, heating of the upstream flow ahead of the shock is observed and quantified, which is not observed at the lower density flow on the 0.2-MA Bertha driver at UC San Diego. Here, when combined with previous work on the XP generator at Cornell, we can show that these three experimental setups allow control of the effect of radiation loss and upstream absorption on the formation of the bow shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal Plasma-Particle Characterization of Dry Aerosols Using Nanosecond, Femtosecond, and Filament Laser-Produced Plasmas

The ability to rapidly characterize dry aerosols in air using laser-induced breakdown spectroscopy (LIBS) with femtosecond laser pulses promises advancement towards real-time atmospheric sampling and standoff capabilities. Of particular interest is the ability to apply LIBS in the context of low-particle loaded environments where discrete particle interactions must be observed within the sampling volume of the laser-produced plasma (LPP). In this study, dry nanoparticles in suspension are generated from a standard solution and sampled in air using Q-switched nanosecond (ns-) pulses, short-focus (SF) femtosecond (fs-) pulses, and filaments. Short time-gated plasma images are captured to observe spatially and temporally varying discrete plasma-particle interactions, which is shown to influence early air breakdown behavior and subsequent plasma evolution. Along with images, photo-multiplier tube (PMT) measurements are conducted where strong spatiotemporal dependencies are exhibited by the collected emission signal on particle proximity and plasma expansion behavior. Finally, conditional analysis is performed on LIBS measurements to determine associated sampling probabilities and filter out spectra with poor or absent emission peaks with an adaptive threshold algorithm.

42 ENGINEERING↗

CryoSegNet: accurate cryo-EM protein particle picking by integrating the foundational AI image segmentation model and attention-gated U-Net

Picking protein particles in cryo-electron microscopy (cryo-EM) micrographs is a crucial step in the cryo-EM-based structure determination. However, existing methods trained on a limited amount of cryo-EM data still cannot accurately pick protein particles from noisy cryo-EM images. The general foundational artificial intelligence–based image segmentation model such as Meta’s Segment Anything Model (SAM) cannot segment protein particles well because their training data do not include cryo-EM images. Here, we present a novel approach (CryoSegNet) of integrating an attention-gated U-shape network (U-Net) specially designed and trained for cryo-EM particle picking and the SAM. The U-Net is first trained on a large cryo-EM image dataset and then used to generate input from original cryo-EM images for SAM to make particle pickings. CryoSegNet shows both high precision and recall in segmenting protein particles from cryo-EM micrographs, irrespective of protein type, shape and size. On several independent datasets of various protein types, CryoSegNet outperforms two top machine learning particle pickers crYOLO and Topaz as well as SAM itself. The average resolution of density maps reconstructed from the particles picked by CryoSegNet is 3.33 Å, 7% better than 3.58 Å of Topaz and 14% better than 3.87 Å of crYOLO. It is publicly available at https://github.com/jianlin-cheng/CryoSegNet

59 BASIC BIOLOGICAL SCIENCES↗

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

Development of an x-ray radiography platform to study laser-direct-drive energy coupling at the National Ignition Facility

A platform has been developed to study laser-direct-drive energy coupling at the National Ignition Facility (NIF) using a plastic sphere target irradiated in a polar-direct-drive geometry to launch a spherically converging shock wave. To diagnose this system evolution, eight NIF laser beams are directed onto a curved Cu foil to generate Heα line emission at a photon energy of 8.4 keV. These x rays are collected by a 100-ps gated x-ray imager in the opposing port to produce temporally gated radiographs. The platform is capable of acquiring images during and after the laser drive launches the shock wave. A backlighter profile is fit to the radiographs, and the resulting transmission images are Abel inverted to infer radial density profiles of the shock front and to track its temporal evolution. Here, the measurements provide experimental shock trajectories and radial density profiles that are compared to 2D radiation-hydrodynamic simulations using cross-beam energy transfer and nonlocal heat-transport models.

47 OTHER INSTRUMENTATION↗

X-ray characterization of the Icarus ultrafast x-ray imager

Ultrafast x-ray imagers developed at Sandia National Laboratories are a transformative diagnostic tool in inertial confinement fusion and high energy density physics experiments. The nanosecond time scales on which these devices operate are a regime with little precedent, and applicable characterization procedures are still developing. This paper presents pulsed x-ray characterization of the Icarus imager under a variety of illumination levels and timing modes. Results are presented for linearity of response, absolute sensitivity, variation of response with gate width, and image quality.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗