Search NASA⌕ Search

SEARCH · Search NASA

Results for “glazing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

Tribological Behavior of Structural Materials in High Temperature Helium Gas-Cooled Reactor Environments

The High-Temperature Gas-cooled Reactor (HTGR) is a Generation IV concept designed to produce electricity and hydrogen at high efficiencies via high operating temperatures (700 °C or higher). Helium, the primary coolant for HTGRs, contains impurities (e.g., CO, H2O and CH4) that can induce corrosion reactions at high temperatures such as oxidation and (de)carburization, which in turn can affect the tribological behavior of components. Incoloy® 800HT (Ni-Fe-Cr austenitic solid-solution alloy) and Inconel® 617 (Ni-Cr-Co-Mo solid-solution alloy) are two high-temperature superalloys currently selected as candidate structural materials for the HTGR. The objective of this study is to evaluate the high-temperature tribological performance of these two candidate alloys after conditioning them in HTGR environments. Four regimes of corrosion were considered: a non-conditioned regime (Regime I), an oxidizing regime (Regime II), a carburizing and oxidizing regime (Regime III), and a carburizing regime (Regime IV). To simulate oxidation in HTGR, samples were conditioned for 22 days at elevated temperatures in a once-through helium loop with 4 ppmv H2O. Carburization of the samples was achieved by the commercial process, Kolsterising®. In addition, two surface treatments – shot peening and aluminization – were considered as potential routes of improving the alloys’ wear resistance. Surface-treated samples were tested both before and after conditioning in Regime II. Tribological testing of the samples was performed via a pin-on-disk tribometer at elevated temperatures in ambient environment – 650 and 750°C for 800HT; 850 and 900°C for 617 – with applied loads of 1N, 2N and 5N. The wear behavior of the alloys was assessed via wear volume and friction coefficient measurements, supported by morphological, structural and compositional analyses of the wear tracks. Conditioning the samples in Regime II led to the formation of a chromium oxide on both alloys. This protective scale increased the wear resistance compared to that of as-received samples (Regime I) due to the formation of a compacted ‘glaze’ oxide layer during sliding, rendering the wear track nearly undistinguishable from the unworn background and resulting in wear volumes below the detection limits of the measurement technique. The variability of the friction coefficients of the conditioned samples was also considerably reduced compared to that of the as-received samples due to the glaze layer. Additionally, the initial friction coefficients of the samples conditioned in Regime II were reduced by 45% and 54% compared to those of as-received samples for alloys 800HT and 617, respectively. Carburizing the samples (Regime IV) hardened the surfaces of both alloys and promoted the formation of an iron oxide on 800HT during tribological testing, thereby increasing the wear resistance and decreasing the initial friction coefficient by a factor of two compared to those of as-received 800HT. Alloy 617 exhibited an enhanced wear resistance but similar initial friction coefficient compared to those of as-received samples due to the increased surface hardness. The Mn-Cr oxide developed during Regime III conditioning of 800HT did not develop a glaze layer during tribotesting, even at lower loads. Thus, it was not as protective as the oxide produced during conditioning of Regime II samples, leading to lower wear resistance of 800HT in Regime III compared to that measured in the Regime II condition. 800HT benefited from the aluminization surface treatment, particularly before conditioning in Regime II, due to the promotion of a wear-resistant aluminum oxide layer during testing and the increase in surface hardness due to the presence of a FeAl intermetallic phase. The presence of this phase caused an order-of-magnitude reduction in wear volumes compared to those of as-received 800HT. Aluminization of 617 decreased its wear resistance, particularly after conditioning in Regime II, due to significant wear of the aluminum oxide via a ceramic wear mechanism. This aluminum oxide was removed during sliding, causing the wear volumes to increase by a factor of five compared to those of 617 conditioned in Regime II. Shot-peened 800HT exhibited a tribological behavior similar to that of as-received 800HT, despite an enhancement in the rate of chromium oxide formation. Shot-peened 800HT conditioned in Regime II showed lower wear resistance compared to that of 800HT conditioned in Regime II due to the poor adhesion between the oxide and the underlying metal, preventing the formation of the glaze layer during sliding. Shot peening of 617 increased its wear resistance at higher load, reducing worn volumes by 60% compared to that measured with as-received 617. Tribotesting of shot-peened 617 in Regime II revealed that the glaze-oxide layer was formed at every load, resulting in negligible wear, similar to what was observed from testing 617 after conditioning in Regime II. Overall, alloy 617 exhibited tribologically superior behavior compared to that of alloy 800HT, as demonstrated by its lower friction coefficients and its order-of-magnitude lower wear volumes when measurable.

36 MATERIALS SCIENCE↗

A method and tool to determine the colorimetric and photobiological properties of light transmitted through glass and other optical materials

Here we describe a framework and provides a computational tool to characterize the color quality and biological potential of light that is transmitted through glass and other optical materials. The IES TM-30 framework and Excel computation tool were adapted to evaluate color quality, with measures from CIE S 026, UL 24480, and the WELL Building Standard v2 added to evaluate biological potential. The user selects a pre-transmittance spectral power distribution (SPD), such as for a CIE D-Series Illuminant, Planckian radiation, electric lamp, or measurement of daylight at a building site. The tool allows a user to populate a database with spectral data for glazing or other optical materials, comprising spectral transmission and the spectral reflectance of both sides. The user creates a unit with one, two, or three panes of glazing or other optical materials, and the tool calculates the composite spectral transmittance accounting for reflections between materials. The tool computes the transmitted SPD, then determines colorimetric and photobiological outputs using the transmitted SPD as the test source. Glass, window, and skylight manufacturers can employ the tool to optimize glazing spectral transmission to achieve intentional colorimetric and photobiological performance with transmitted light. Electric lighting manufacturers, designers, and researchers can use the tool to evaluate the impact of glazing units and other optical materials on the color quality and biological potential of transmitted light.

36 MATERIALS SCIENCE↗

Reference Cell Performance and Modeling on a One-Axis Tracking Surface: Preprint

Performance of five silicon-based reference cells is examined on a single-axis tracking surface. The reference cells' output are modeled using one-minute sampled spectral irradiance and reference cell temperature measurements. The model also incorporates spectral responsivity data for the reference cell. The transmission of light through the glazing multiplies the sum over all appropriate wavelengths of temperature adjusted reference cell responsivity times the measured spectral irradiance. Modeled reference cell output is compared with measured reference cell output under clear sky and totally cloudy sky conditions. For each reference cell the ratio of modeled to measured output varies by less than 2% over the year.

modeling↗

Dataset describing two reference models for full-spectral lighting and daylight simulations together with implementations for two software systems

A dataset of two spectral lighting simulation reference models - one office and one factory hall - is presented. It aims to demonstrate and support full-spectral daylight and electric lighting simulations and facilitate evaluation of non-visual effects of light. The dataset includes Rhino CAD geometry, comprehensive spectral material and light source data and window system BSDF data. Example implementations in the two software tools, Radiance and OWL, enable reproducible workflows and support adoption in other software. The dataset is openly available on Zenodo. The office model reproduces Room 518 at the University of Innsbruck, including a west-facing façade and interior furnishings. The factory hall model follows the proposed geometry in the European standard 15193 for building energy performance. Interior reflectances in the office were measured in-situ using a handheld spectrometer. Exterior spectra and factory hall materials matching specified reflectances were obtained from an online spectral materials database. Glazing transmittance was derived from IGDB data using LBNL Optics/WINDOW. BSDFs for venetian blinds at various tilt angles, and for a diffusing pane adapted from the Complex Glazing Database, were generated in WINDOW. Luminaires in both models are specified with photometric files (Eulumdat/IES) and lamp spectra (Fluorescent 840, 4000 K LED). The provided example implementations (Radiance, OWL) include prepared input data and scripts to run first spectral simulations; example results are also included. The dataset is prepared to support reuse by researchers, designers and software developers for method validation, software engineering and comparison, and development of spectral metrics and controls.

Geisler-Moroder, David↗

Wear Performance of incoloy 800HT and inconel 617 in various surface conditions for high-temperature gas-cooled reactor components

Incoloy™ 800HT and Inconel™ 617 are primary candidate structural materials for high-temperature gas-cooled reactors (HTGRs). Impurities (e.g., H 2 O, CH 4 ) in the coolant induce corrosion reactions that affect tribological behavior. We investigate the high-temperature tribological performance of the alloys under surface conditions including: conditioned in H 2 O-containing helium at elevated temperatures, hardened via the carbon-diffusion Kolsterising® treatment, and conditioned after hardening. Initial friction coefficients and volume removed serve as metrics for wear performance. In this work, we find that wear mechanisms including scuffing, glaze-oxide formation, and oxide-layer wear and break-through are governed by surface hardness, chemistry, and applied load. The formation of a glaze-oxide layer is achieved with an oxide of sufficient mechanical integrity if the oxide-substrate interface is strong and the load is low.

42 ENGINEERING↗

Low-Voltage Haze Tuning with Cellulose-Network Liquid Crystal Gels

Being key components of the building envelope, glazing products with tunable optical properties are in great demand because of their potential for boosting energy efficiency and privacy features while enabling the main function of allowing natural light indoors. However, windows and skylights with electric switching of haze and transparency are rare and often require high voltages or electric currents, as well as not fully meet the stringent technical requirements for glazing applications. Here, by introducing a predesigned gel material we describe an approach dubbed “Haze-Switch” that involves low-voltage tuning of the haze coefficient in a broad range of 2–90% while maintaining high visible-range optical transmittance. The approach is based on a nanocellulose fiber gel network infiltrated by a nematic liquid crystal, which can be switched between polydomain and monodomain spatial patterns of optical axis via a dielectric coupling between the nematic domains and the applied external electric field. By utilizing a nanocellulose network of nanofibers ~10 nm in diameter we achieve <10 V dielectric switching and <2% haze in the clear state, as needed for applications in window products. Finally, we characterize physical properties relevant to window and smart glass technologies, like the color rendering index, haze coefficient, and switching times, demonstrating that our material and envisaged products can meet the stringent requirements of the glass industry, including applications such as privacy windows, skylights, sunroofs, and daylighting.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Window Film

This documentation focuses on a single end-use savings shape measure - window film. The window film studied in this analysis, called solar control film, is a passive retrofit solution for windows that does not involve window replacement. This type of film is composed of transparent, tinted, or metalized laminated polyester layers and can be attached to an existing window surface (either on the exterior or interior side of the window). The properties of the window film are designed to shift the thermal and optical performances of the overall glazing system in order to serve various needs the customer would have (e.g., heat, glare). While the practical goal of purchasing and installing a window film varies widely in the real market, this study only focuses on the goal of energy savings, and highlighting the corresponding emissions. Other important aspects that customers typically consider include visual comfort, privacy, aesthetics, ultraviolet protection, etc. Thus, in practice, customers often choose a window film product not only to save energy (or cost) but also to mitigate issues around glare, excessive light, daytime privacy, or inconsistent appearance of the building. Window film products that were modeled in this analysis significantly reduced the solar heat gain coefficient of the overall glazing system, resulting in better energy savings for buildings in hot climate regions. However, significantly reducing the solar heat gain coefficient that can block unfavorable heat during the summer can actually harm blocking favorable heat during the winter. By applying window films on a stock of buildings covering various load and weather conditions, this analysis highlights when (e.g., time of day) and where (e.g., geospacial location) we can save energy with window films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy impacts of nationwide window upgrades in commercial buildings

This report presents comprehensive estimates of the energy impacts of nationwide commercial building window upgrades in the United States, using a conservative approach. Windows play a substantial role in determining building energy use and occupant experience. Estimates point to commercial building windows impacting loads that represent more than 6 quads (approximately 6%) of annual primary energy use in the U.S. (Harris, 2022). Beyond heating and cooling loads, windows also have effects on lighting and occupant comfort. The fastest route to improving the energy efficiency of windows in U.S. buildings is upgrading or replacing windows in existing buildings. This is due to poor performance of windows in older existing buildings compared to most new construction, low levels of window replacement, and long window service life compared to energy-using building components. Nationwide window upgrades were considered using the following technologies: • Secondary glazing systems • Double pane (clear and tinted) • Triple pane (clear and tinted) • Electrochromic glazing Nationwide upgrades provide on the order of 4%–6% site energy savings in typical buildings, or up to 26% in buildings with the highest savings potential. Electrochromic windows, with their ability to adapt dynamically to environmental conditions, can provide additional benefits, ranging from median savings of 7.2% in buildings with window to wall ratio (WWR) greater than 10% and up to 28% for some buildings. Savings increase substantially for buildings with higher WWR. This study’s approach focused on isolating the direct energy benefits from improvement in window performance, and does not take into account the following additional benefits from window retrofits, which are likely to be substantial: • Managing peak demand and enabling HVAC equipment downsizing. • Energy savings from customizing upgrades to building type and climate. • Energy savings and comfort improvements resulting from post-retrofit reductions in air leakage. • Non-energy benefits, such as occupant comfort and resilience during extreme weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulative Prediction of Solar Illuminance and Application of the Du-Sharples Model in Estimating Adapted Daylighting Metrics for an Urban Environment

The practice of daylighting in indoor spaces can significantly reduce electricity consumption and carbon emissions, improve human productivity, and enhance mood and cognitive perception. This work discussed the recent developments in daylighting science and practice, computed the periodic variations in average diurnal daylight levels for each month, quantified in terms of global horizontal illuminance and diffuse horizontal illuminance, for Kolkata, India, a city with tropical wet and dry climate, with two empirical luminous efficacy models of estimating solar illuminance, and assessed daylighting metrics with the Du-Sharples model. A program was formulated that could compute and generate daylight data with monthly-hourly solar irradiation data and the Du-Sharples model was utilized to predict dirt-corrected daylighting metrics for three glazing transmittance values and five elemental carbon deposition levels on glazing material. The highest monthly average global horizontal illuminance is recorded in April (64.05 klx for Littlefair model and 66.82 klx for Muneer-Kinghorn model) and the highest monthly average diffuse horizontal illuminance is recorded in July (33.23 klx for Littlefair model and 30.63 klx for Muneer-Kinghorn model). Further, the computed yearly average global and diffuse horizontal illuminance levels agree well with a previous study that applied the Perez model. Yearly average horizontal work surface illuminance level remained >1.5 klx for window-towall area ratio >30 %. The approach adopted in this work and the temporal variation charts of computed exterior daylight level data may assist building service engineers, architects, and indoor lighting practitioners in making informed policy decisions at different stages of building planning.

Engineering↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Thermochromic Halide Perovskite Windows with Ideal Transition Temperatures

Abstract Urban centers across the globe are responsible for a significant fraction of energy consumption and CO 2 emission. As urban centers continue to grow, the popularity of glass as cladding material in urban buildings is an alarming trend. Dynamic windows reduce heating and cooling loads in buildings by passive heating in cold seasons and mitigating solar heat gain in hot seasons. Here, reduced energy consumption in highly glazed buildings in a mesoscopic building energy model is demonstrated when thermochromic windows are employed. Savings are realized across eight disparate climate zones of the United States. The model is used to determine ideal critical transition temperatures of 20–27.5 °C for thermochromic windows based on metal halide perovskite materials. Ideal transition temperatures are realized experimentally in composite metal halide perovskite films composed of perovskite crystals and an adjacent reservoir phase. The transition temperature is controlled by cointercalating methanol, instead of water, with methylammonium iodide and tailoring the hydrogen‐bonding chemistry of the reservoir phase. Thermochromic windows based on metal halide perovskites represent a clear opportunity to mitigate the effects of energy‐hungry buildings.

14 SOLAR ENERGY↗

A rotorcraft in-flight ice detection framework using computational aeroacoustics and Bayesian neural networks

Abstract This work develops a novel ice detection framework specifically suitable for rotorcraft using computational aeroacoustics and Bayesian neural networks. In an offline phase of the work, the acoustic signature of glaze and rime ice shapes on an oscillating wing are computed. In addition, the aerodynamic performance indicators corresponding to the ice shapes are also monitored. These performance indicators include the lift, drag, and moment coefficients. A Bayesian neural network is subsequently trained using projected Stein variational gradient descent to create a mapping from the acoustic signature generated by the iced wings to predict their performance indicators along with quantified uncertainty that is highly important for time- and safety-critical decision-making scenarios. While the training is carried out fully offline, usage of the Bayesian neural network to make predictions can be conducted rapidly online allowing for an ice detection system that can be used in real time and in-flight.

42 ENGINEERING↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daylight simulation workflows incorporating measured bidirectional scattering distribution functions

Daylight predictions of architectural spaces depend on good estimates of light transfer through skylights, windows and other fenestration systems. For clear glazing and painted surfaces, parametric transmission and reflection models have proven adequate, but there are many cases where light-scattering, semi-specular shading and daylighting materials defy simple characterization. Something as commonplace as fabric roller shades and venetian blinds may turn daylight prediction into guesswork, and numerous advanced systems on the market tuned specifically to enhance daylight are not sufficiently characterized to distinguish their performance. In this paper, we describe new tools available to handle novel and specialized fabrics, materials, and devices using data-driven modelling of bi-directional scattering distribution functions (BSDFs). These representations are usually tabulated at constant or adjustable angular resolution for efficient point-in-time and annual daylight simulations. We describe a variety of BSDF simulation workflows, including some of the tools and methods that make advanced analysis possible, and highlight some of the current challenges. We conclude with a discussion of future work and how such data might be created and shared worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term effects of thinning and woody control on longleaf pine plantation development, understory abundance, and tree damage from an ice storm

Longleaf pine (Pinus palustris) plantations have been established across the southeastern United States as the first step in restoring the declining savanna ecosystem, yet their long-term stability and development to open canopied woodlands may depend on early density and vegetation management treatments. Commercial thinning (CT) was applied in 2012 (year 18) to a long-term study of longleaf pine community restoration at the Savannah River Site near Aiken, SC to increase abundance of herb species. Although precommercial thinning (PCT) and woody vegetation control increased herb species cover during the first five years of the study, measurements from years 17 to 22 indicated a continuing decline in their cover since year 9 despite application of CT in year 18. Herb species richness, however, increased from 21 to 43 species per 100 m2 area during the last six years of the study, likely a result of disturbances associated with CT and an ice storm in year 20. Application of PCT in 1994, when the plantations were 8–11 years old, reduced their susceptibility to stem bending and breakage from the ice storm, which occurred 20 years later in 2014. Measured 5 months before the storm, pine height: dbh ratio (HD) averaged 78 and 90 for trees growing with and without PCT, respectively, and stem breakage (% of trees) from the ice storm increased linearly (r2 = 0.53) with HD. Pine mortality from the combined effects of glaze ice and wind differed with (28%) versus without (45%) PCT, indicating that long-term stability of longleaf pine plantations depends on early density management.

54 ENVIRONMENTAL SCIENCES↗