Search NASA⌕ Search

SEARCH · Search NASA

Results for “grab sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SARS-CoV-2 raw wastewater surveillance from student residences on an urban university campus

The COVID-19 pandemic brought about an urgent need to monitor the community prevalence of infection and detect the presence of SARS-CoV-2. Testing individual people is the most reliable method to measure the spread of the virus in any given community, but it is also the most expensive and time-consuming. Wastewater-based epidemiology (WBE) has been used since the 1960s when scientists implemented monitoring to measure the effectiveness of the Polio vaccine. Since then, WBE has been used to monitor populations for various pathogens, drugs, and pollutants. In August 2020, the University of Tennessee-Knoxville implemented a SARS-CoV-2 surveillance program that began with raw wastewater surveillance of the student residence buildings on campus, the results of which were shared with another lab group on campus that oversaw the pooled saliva testing of students. Sample collection began at 8 am, and the final RT-qPCR results were obtained by midnight. The previous day’s results were presented to the campus administrators and the Student Health Center at 8 am the following morning. The buildings surveyed included all campus dormitories, fraternities, and sororities, 46 buildings in all representing an on-campus community of over 8,000 students. The WBE surveillance relied upon early morning “grab” samples and 24-h composite sampling. Because we only had three Hach AS950 Portable Peristaltic Sampler units, we reserved 24-h composite sampling for the dormitories with the highest population of students. Samples were pasteurized, and heavy sediment was centrifuged and filtered out, followed by a virus concentration step before RNA extraction. Each sample was tested by RT-qPCR for the presence of SARS-CoV-2, using the CDC primers for N Capsid targets N1 and N3. The subsequent pooled saliva tests from sections of each building allowed lower costs and minimized the total number of individual verification tests that needed to be analyzed by the Student Health Center. Our WBE results matched the trend of the on-campus cases reported by the student health center. The highest concentration of genomic copies detected in one sample was 5.06 × 10 7 copies/L. Raw wastewater-based epidemiology is an efficient, economical, fast, and non-invasive method to monitor a large community for a single pathogen or multiple pathogen targets.

60 APPLIED LIFE SCIENCES↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Raman Spectroscopic In Situ Monitoring of Highly Turbid Media

The ability to run chemical processing more efficiently and cost effectively is a need that spans critical materials recovery and legacy nuclear waste cleanup. Sensors integrated to provide online monitoring are essential to addressing this need by providing near-real time feedback on process conditions, which can improve efficiency, aid in decision making, and reduce the need for grab sample measurements. Optical spectroscopy is well-suited for providing online chemical composition information and has been widely applied in varied chemical systems. However, applications in turbid matrices continue to represent substantial challenges to sensor performance, where absorption or scattering of excitation light can cause significant signal interference. Here, in this study, close-focus Raman probes are investigated for use in turbid media as a way to overcome the signal loss from the scattering of the Raman excitation source. This, paired with advanced data science techniques, allowed for the development of chemometric models for the accurate quantification of several analytes of interest (NO 3 – , NO 2 – , and PO 4 3– ) in highly turbid solutions with solids loadings of up to 20 wt %. This work focuses on offline sample measurement and characterization as an initial step toward the development of online monitoring capabilities. Chemical systems of interest were focused on nuclear waste at the Hanford Site, which represents highly complex matrices that could realize significant processing benefits through the integration of online monitoring.

Felmy, Heather M. [Pacific Northwest National Labo↗

Sensor-Equipped Unmanned Surface Vehicle for High-Resolution Mapping of Water Quality in Low- to Mid-Order Streams

Longitudinal profiling of water quality via the deployment of sensors from watercraft has advanced the understanding of spatial patterns in large rivers and lakes; however, a similar approach in low- to mid-order streams is lacking. To fill this gap, we developed an unmanned surface vehicle (USV)-water quality measurement platform (the “AquaBOT”). The components of the AquaBOT included a nitrate sensor, multiparameter sonde (temperature, conductivity, turbidity, dissolved oxygen, chlorophyll), quantum sensor, and global positioning system (GPS) mounted to a small pontoon-style USV. The AquaBOT was tested in four streams and rivers in Iowa and Tennessee. All measured water quality parameters varied longitudinally, and greater ranges were generally observed along the low-order, agriculturally influenced streams in Iowa. Nitrate, in particular, was spatially heterogeneous. For example, during one run in early June, concentrations ranged from 10.5 to 12.5 mg N L –1 along a 2.3 km reach and hotspots were observed directly downstream of some tile drains. The spatial resolution of AquaBOT data collected in June was 10× higher than grab sampling data, and measurements were collected in less time and at a comparable cost. Here, the AquaBOT can complement existing measurement approaches and will lead to advancements in understanding the processes driving water quality along the stream-to-river continuum.

47 OTHER INSTRUMENTATION↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards non-contact pollution monitoring in sewers with hyperspectral imaging

Monitoring water quality in sewers is challenging, particularly because state-of-the-art technologies require contact with the raw wastewater. The presence of fat, oil, grease, and solids makes automated grab sampling difficult and causes sensor fouling. To overcome these limitations, non-contact methods based on light reflectance, such as hyperspectral imaging (HSI), are gaining attention. However, HSI has never been tested for raw wastewater. To assess its accuracy for measuring pollution, we developed a laboratory setup and performed targeted experiments with a combination of raw and diluted wastewater, as well as synthetic turbidity stock solutions. We measured seven pollution variables: chemical oxygen demand, turbidity, dissolved organic compounds, ammonium, total nitrogen, phosphate, and sulphates. We used automated pixel selection and partial least squares regression to retrieve pollution information from the hyperspectral images. Our results, based on 144 samples, suggest that HSI can estimate pollution levels with a precision in the range of state-of-the-art absorbance spectrophotometric methods. Additionally, we found that the combination of pixel and wavelength selection, enabled by the hyperspectral data structure, significantly influences the performance of partial least square modelling. Overall, our findings indicate that HSI is a promising technology for non-contact monitoring of water quality in raw wastewater.

54 ENVIRONMENTAL SCIENCES↗

Levoglucosan data from five coastal streams impacted by the 2020 CZU Lightning Complex Fires, California, United States

This dataset includes levoglucosan data for five coastal California (United States) streams impacted by the 2020 CZU Lightning Complex Fires which burned from August 16th through September 22nd. Levoglucosan is a highly soluble and biolabile fraction of pyrogenic carbon. The five watersheds (San Lorenzo River, Pescadero Creek, Majors Creek, Laguna Creek, and Scott Creek) were impacted by the fires with watersheds experiencing a range of burn severity and extents. Grab samples were collected from each stream between October 2020 and May 2021, targeting both baseflow and event flow hydrologic conditions. Additional biogeochemistry data (i.e., organic and black carbon concentrations) can be found in a separate data package (https://doi.org/10.4211/hs.421c0226bb38460c8393d67fe0c4f802). This data package consists of one main data folder that contains (1) readme; (2) file-level metadata; (3) data dictionary; (4) field metadata with international generic sample numbers (IGSN); (5) methods codes; and (6) levoglucosan data. All files are .csv or .pdf.

2020 CZU Lightning Complex Fires↗

SPRUCE: Shrub Leaf and Stem Functional Traits from 10-year Shrub Layer Biomass Harvests (August 2025)

This data set contains Leaf Mass Area (LMA), Specific Leaf Area (SLA), Leaf Area Index (LAI), and Huber value (Hv) measurements from the 10-year Shrub-layer Biomass harvests in the Spruce and Peatland Responses Under Environmental Change (SPRUCE) experiment in August 2025. The total ground-level cross-sectional sapwood area of Chamaedaphne calyculata (CHCA), Rhododendron groenlandicum (RHGR), and Vaccinium angustifolium (VAAN) were calculated for each of the three shrub-layer community survey plots located in each experimental enclosure. Representative current-year leaves were removed, scanned, dried, and weighed to derive SLA. Grab-samples for VAAN were used to calculate SLA when no biomass was harvested in the shrub-layer community plots. These SLA values were used to infer total one-sided leave surface area from the total species lead dry mass for calculation of LAI and Hv.

Birkebak, Joshua [ORNL] (ORCID:0009000955611494)↗

Measuring Hydroxylammonium, Nitrate, and Nitrite Concentration with Raman Spectroscopy for 238 Pu Supply Program

Optical spectroscopy has great potential to improve the timeliness of important analytical measurements for the 238 Pu Supply Program by enabling real-time analysis of process solutions within radiochemical hot cells. Hydroxylammonium (H 3 NOH + ]), nitrate (NO 3 - ), and nitrite (NO 2 - ) are three important molecular species present in multiple aqueous streams throughout the program’s flow sheet. The concentration of each species normally goes uncharacterized during processing. However, rapid quantification may benefit the program because uncertainties in kinetic redox expressions describing hydroxylammonium (HA) and nitrite reactions with Np and Pu leads to uncertainty in process model predictions for solvent extraction runs. HA concentration is normally quantified using ion chromatography, a technique that requires diluted grab samples taken out of the hot cell and analyzed off-line. Here we evaluate Raman spectroscopy for determining the concentration of H 3 NOH + , NO 3 - , and NO 2 - in benchtop tests to determine limits of detection. We also consider the possibility of using Raman spectroscopy in both glove box and hot cell environments for rapid analysis and pinpoint additional development opportunities needed to make this application successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing an-In-Field Alpha Spectrometer (IFAS)-for UF 6 Enrichment Measurement [Slides]

This project is developing an in-field alpha spectrometry system for the purpose of assaying grab samples of uranium hexafluoride (UF 6 ) and determining uranium enrichment. This new system will accommodate Single-Use Destructive Assay (SUDA) samples (PNNL) and will be robust to handle elevated beta-decay radiation present in UF 6 samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Intensity of sample processing methods impacts wastewater SARS-CoV-2 whole genome amplicon sequencing outcomes

Wastewater SARS-CoV-2 surveillance has been deployed since the beginning of the COVID-19 pandemic to monitor the dynamics in virus burden in local communities. Genomic surveillance of SARS-CoV-2 in wastewater, particularly efforts aimed at whole genome sequencing for variant tracking and identification, are still challenging due to low target concentration, complex microbial and chemical background, and lack of robust nucleic acid recovery experimental procedures. The intrinsic sample limitations are inherent to wastewater and are thus unavoidable. Here, we use a statistical approach that couples correlation analyses to a random forest-based machine learning algorithm to evaluate potentially important factors associated with wastewater SARS-CoV-2 whole genome amplicon sequencing outcomes, with a specific focus on the breadth of genome coverage. We collected 182 composite and grab wastewater samples from the Chicago area between November 2020 to October 2021. Samples were processed using a mixture of processing methods reflecting different homogenization intensities (HA + Zymo beads, HA + glass beads, and Nanotrap), and were sequenced using one of the two library preparation kits (the Illumina COVIDseq kit and the QIAseq DIRECT kit). Technical factors evaluated using statistical and machine learning approaches include sample types, certain sample intrinsic features, and processing and sequencing methods. The results suggested that sample processing methods could be a predominant factor affecting sequencing outcomes, and library preparation kits was considered a minor factor. Finally, a synthetic SARS-CoV-2 RNA spike-in experiment was performed to validate the impact from processing methods and suggested that the intensity of the processing methods could lead to different RNA fragmentation

60 APPLIED LIFE SCIENCES↗

What’s in My Toolkit? A Review of Technologies for Assessing Changes in Habitats Caused by Marine Energy Development

Marine energy devices are installed in highly dynamic environments and have the potential to affect the benthic and pelagic habitats around them. Regulatory bodies often require baseline characterization and/or post-installation monitoring to determine whether changes in these habitats are being observed. However, a great diversity of technologies is available for surveying and sampling marine habitats, and selecting the most suitable instrument to identify and measure changes in habitats at marine energy sites can become a daunting task. We conducted a thorough review of journal articles, survey reports, and grey literature to extract information about the technologies used, the data collection and processing methods, and the performance and effectiveness of these instruments. We examined documents related to marine energy development, offshore wind farms, oil and gas offshore sites, and other marine industries around the world over the last 20 years. A total of 120 different technologies were identified across six main habitat categories: seafloor, sediment, infauna, epifauna, pelagic, and biofouling. The technologies were organized into 12 broad technology classes: acoustic, corer, dredge, grab, hook and line, net and trawl, plate, remote sensing, scrape samples, trap, visual, and others. Visual was the most common and the most diverse technology class, with applications across all six habitat categories. Technologies and sampling methods that are designed for working efficiently in energetic environments have greater success at marine energy sites. In addition, sampling designs and statistical analyses should be carefully thought through to identify differences in faunal assemblages and spatiotemporal changes in habitats.

16 TIDAL AND WAVE POWER↗

Triton Field Trials - Changes in Habitats, a Literature Review of Monitoring Technologies

Marine energy devices are installed in highly dynamic environments and have the potential to affect benthic and pelagic habitats around them. Regulatory bodies often require baseline characterization and/or post-installation monitoring to determine whether changes in these habitats are being observed. However, a great diversity of technologies is available for surveying and sampling marine habitats. Selecting the most suitable instrument to identify and measure changes in habitats at marine energy sites can become a daunting task. We conducted a thorough review of journal articles, survey reports, and grey literature to extract information about the technologies used, the data collection and processing methods, and the performance and effectiveness of these instruments. We examined documents related to marine energy development, offshore wind farms, oil and gas offshore sites, and other marine industries around the world over the last 20 years, as well as national and international guidelines for surveying habitats around offshore activities. A total of 120 different technologies were identified across six main habitat categories: seafloor, sediment, infauna, epifauna, pelagic, and biofouling. The technologies were organized into 12 broad technology classes: acoustic, corer, dredge, grab, hook and line, net and trawl, plate, remote sensing, scrape samples, trap, visual, and others. Visual was the most common and the most diverse technology class, with applications across all six habitat categories. Sampling designs varied considerably among the reviewed studies but transect was the predominant design for surveying seafloor, epifauna, and pelagic habitats. The most common data analyses were univariate and multivariate statistical analyses aimed at calculating and comparing biodiversity indices, characterizing faunal assemblages or sediment classes, or modeling the distribution of animals related to abiotic parameters. Technologies and sampling methods adaptable and designed to work efficiently in energetic environments have greater success at marine energy sites. In addition, sampling designs and statistical analyses should be carefully thought through to identify differences in faunal assemblages and spatiotemporal changes in habitats.

16 TIDAL AND WAVE POWER↗

Pre–T cell receptors topologically sample self-ligands during thymocyte β-selection

Self-discrimination, a critical but ill-defined molecular process programmed during thymocyte development, requires myriad pre–T cell receptors (preTCRs) and αβTCRs. Using x-ray crystallography, we show how a preTCR applies the concave β-sheet surface of its single variable domain (Vβ) to “horizontally” grab the protruding MHC α2-helix. By contrast, αβTCRs purpose all six complementarity-determining region (CDR) loops of their paired VαVβ module to recognize peptides bound to major histocompatibility complex molecules (pMHCs) in “vertical” head-to-head binding. Additionally, the preTCR topological fit ensures that CDR3β reaches the peptide’s featured C-terminal segment for pMHC sampling, establishing the subsequent αβTCR canonical docking mode. “Horizontal” docking precludes germline CDR1β- and CDR2β-MHC binding to broaden β-chain repertoire diversification before αβTCR-mediated selection refinement. Thus, one subunit successively attunes the recognition logic of related multicomponent receptors.

59 BASIC BIOLOGICAL SCIENCES↗

AI-Batt (Autonomous Identification of Battery Life Models) [SWR 21-36]

Autonomous Identification of Battery Life Models (AI-Batt) AI-Batt is a MATLAB code base for developing lifetime models for batteries from accelerated aging data. The code base provides many functions for processing, visualizing, and modeling battery aging data, making the data processing, exploration, and modeling workflow substantially faster. These tools are tailored for working with battery aging data sets, which usually consist of many separate time-series for each cell, with many test conditions and possible replicates at each condition, which makes it difficult to simply process or visualize the data set. Complex modeling tasks, such as cross-validation, sensitivity analysis, and uncertainty quantification have been implemented to enable thorough statistical investigation of model predictions. Additionally, several machine-learning algorithms are implemented to autonomously identify suitable models via symbolic regression. Data processing functions automatically cast data from the struct data type, which is commonly used to store experimental data, but is not an acceptable input for most algorithms, to the table data type, which can be easily used as input to any optimization algorithm. Also, the data can be separated into time-invariant and time-variant data tables, which is helpful for exploring the data set as well as developing separate models for time-variant and time-invariant aging mechanisms. For example, in aging tests with constant temperature, temperature is a time-invariant experimental condition. Visualization tools enable plotting of data, model fits, and model simulations possible with single-line function calls, empowering data exploration of complex data sets with both time-varying and time-invariant trends. Plots can be automatically generated for the whole data set, or separated by data group (groups of test replicates) or individual data series. Data points or data series can be automatically colored by the value of a variable with a variety of color maps, and model predictions can also be colored by the value of a fit statistic. Comparisons between data sets and the predictions/simulations of different models on the same data set can be easily plotted as well. Distributions of parameter values from bootstrap resampling can be plotted to visualize the reliability of parameter estimation, or determine any correlations between parameters. Modeling tools handle the complex task of creating and parsing symbolic equations for modeling battery lifetime. Equations are parsed to grab relevant data variables, parameter values, or specified sub-models for input into optimization, evaluation, or simulation functions. Models can be optimized locally (one set of parameters for each data series), bi-level (some parameters shared across the data set), or globally (single set of parameters for all data). Functions implementing symbolic regression algorithms help users to discover effective model equations, even in poorly sampled, high-dimensional data.

Smith, Kandler↗

Observation and differential cross section measurement of neutral current DIS events with an empty hemisphere in the Breit frame

The Breit frame provides a natural frame to analyze lepton–proton scattering events. In this reference frame, the parton model hard interactions between a quark and an exchanged boson defines the coordinate system such that the struck quark is back-scattered along the virtual photon momentum direction. In Quantum Chromodynamics (QCD), higher order perturbative or non-perturbative effects can change this picture drastically. As Bjorken-x decreases below one half, a rather peculiar event signature is predicted with increasing probability, where no radiation is present in one of the two Breit-frame hemispheres and all emissions are to be found in the other hemisphere. At higher orders in $\alpha$ s or in the presence of soft QCD effects, predictions of the rate of these events are far from trivial, and that motivates measurements with real data. We report on the first observation of the empty current hemisphere events in electron–proton collisions at the HERA collider using data recorded with the H1 detector at a center-of-mass energy of 319 GeV. The fraction of inclusive neutral-current DIS events with an empty hemisphere is found to be 0.0112 ± 3.9% stat ± 4.5% syst ± 1.6% mod in the selected kinematic region of 150 < Q 2 < 1500 GeV 2 and inelasticity 0.14 < y < 0.7. The data sample corresponds to an integrated luminosity of 351.1 pb -1 , sufficient to enable differential cross section measurements of these events. The results show an enhanced discriminating power at lower Bjorken-x among different Monte Carlo event generator predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗