Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

ExaWind: Predictive Wind Energy Simulations

This presentation describes the ExaWind project and the team's progress in creating a suite of performance-portable codes designed for predictive simulations of wind farms on next-generation exascale-class supercomputers. Such simulations will require the resolution of scales spanning many orders of magnitude, from blade boundary layers to wind farm flow structures. In the U.S., the first exascale systems will be GPU accelerated, and different GPU manufacturers have been chosen for the different systems. At the heart of the ExaWind software is a hybrid-solver approach based on the codes Nalu-Wind and AMR-Wind, which are computational fluid dynamics solvers for the incompressible Navier-Stokes equations. Nalu-Wind is an unstructured-grid code used to resolve wind turbine geometry and blade boundary layers, whereas AMR-Wind is a structured-grid background solver for atmospheric turbulent flow and turbine wake propagation. The models are coupled with overset meshes and global linear systems are approximated through a loose-coupling algorithm. Results will include validation-quality high-fidelity simulations and strong/weak scaling results from the Summit supercomputer.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗

Hybrid Modeling of Three-Phase Grid-Supporting Inverters for Dynamic Studies

Grid technologies connected by power electronic converter (PEC) interfaces continually implement grid support functions mandated by grid codes and standards. The transition to converter-based generation demands precise PEC models to assess system dynamics, which have been previously overlooked in conventional power systems. This study proposes a hybrid method for analyzing grid-connected three-phase PEC dynamics with the IEEE standard 1547-2018 Volt-VAr mode that combines physics and data-driven techniques. The physics model reflects the PEC’s internal behavior, whereas the data-driven modeling technique evaluates the grid-supporting capabilities of the smart PEC. The system identification approach is used to generate dynamic PEC models based on changing grid voltage and measured current injected into the grid by the PEC. In the Volt-VAr support mode, a detailed topological model including switches is utilized to compare the goodness-of-fit of the extracted hybrid dynamic model. The results demonstrate that the hybrid PEC model in the Volt-VAr mode accurately matches the dynamics with the topological model.

Subedi, Sunil↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration Study of Converter-Interfaced Combined Heat and Power Plants

Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.

Converter, Combined heat and power, Distributed en↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Model predictive control for voltage restoration in microgrids using temporal logic specifications

Power system operation will encounter numerous voltage variabilities as the proliferation of renewable energy continues. Real-time monitoring and communication technologies can potentially improve voltage stability by enabling the rapid detection of voltage deviations and the implementation of corrective actions. These corrective actions will only be effective in restoring stability if they are chosen in a timely and scalable manner. This paper considers the problem of power systems’ load voltage control in order to simultaneously address both magnitude and time voltage specifications. In order to comply with grid codes and avoid unnecessary relay protection actions, a model predictive control (MPC)-based control strategy employing temporal logic specifications (TLSs) is proposed. The TLSs strategy is introduced as a formalism to control the voltage variation at a critical load bus against operational bounds over time. The control objective is to schedule optimal control input signals from the available supportive energy storage systems, which provide reactive power injections, leading to satisfying the specified finite-time restoration described by the TLSs with minimal control efforts. The simulation results display that the TLSs strategy for power systems’ voltage control synthesis is extremely significant.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimentation in Exploring Photovoltaic Inverter Dynamics Under Different Irradiance Levels Through a Data-Driven Approach

As conventional direct connections of synchronous generators are being phased out, inverter-based resources (IBRs) with grid support functions are increasingly being integrated into power systems. This transition requires the development of accurate dynamic models for IBRs to predict how power systems will adapt to varying levels of IBRs penetration, establish grid code requirements, and ensure compliance. Here, this study introduces an active probing signal-based data-driven modeling technique to accurately derive the dynamics model of a smart photovoltaic inverter operating in Volt-Watt and Freq-Watt modes, in compliance with the IEEE 1547–2018 standard. The paper focuses on investigating how the dynamics of the PV inverter model respond to fluctuations in solar irradiance, utilizing real-time digital simulator experimentation. The experimental analysis demonstrates that the amplitude of dynamics fluctuates with changes in irradiance across both operational modes and confirms the active power’s dependence on irradiance levels. Furthermore, the nature of inverter dynamics varies distinctly between the different modes of activation. Critically, our findings indicate that dynamic models require DC-gain adjustments to accommodate contrasting irradiance levels, highlighting a negative gradient linear relationship between the DC-gain of each model and the irradiance.

14 SOLAR ENERGY↗

Secondary Voltage Control Via Demand-Side Energy Storage with Temporal Logic Specifications

This paper proposes a secondary voltage control method that can handle the temporal logic specifications (TLSs). The control objective is to schedule a control signal for energy storage system (ESS) such that the voltage variation of a defined critical bus satisfies TLSs. The TLS allows definitions of set and timing constraints at the same time, such as a finite-time restoration. A simplified analytical model is derived to describe the voltage variation of critical buses. Based on this model, a numerical optimal control problem is formulated as a mixed integer linear program to generate the proper control input for the ESS. The proposed control is verified on a lumped distribution system model. With this control diagram, supportive controllers can be easily designed to make voltage behaviors comply with grid codes and avoid unnecessary relay actions.

Zhang, Yichen↗

On the Need for Communication for Voltage Regulation of Power Distribution Grids

We consider the problem of regulating the voltage profile of a power distribution grid by controlling the reactive power injection of distributed microgenerators. We define a very general class of purely local feedback controllers in which reactive power injection is adjusted based on the local voltage measurements. This class includes most of the solutions proposed in the literature and in the latest grid codes. We show that these strategies do not guarantee the desired regulation, as each of them can have an equilibrium that is not feasible with respect to the desired voltage and power constraints. We then propose a networked feedback law to show that, by adding short-range communication between microgenerators, it is possible to design control strategies that provably converge to the feasible set. This fundamental performance gap between local and networked strategies is finally illustrated via simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗

Fault Response of Distributed Energy Resources Considering the Requirements of IEEE 1547-2018

Inverter-based DER responses to faults on the electric power system are different than those of conventional generators and are often poorly understood. Inverter fault responses are largely software-defined, within physics-based constraints. DERs are regulated by standards and grid codes that also constrain their responses. Though fault response of DERs will vary widely, for any DER following any particular standard, a pattern of fault response can be synthesized by observing that particular standard. In this paper, the recently published IEEE 1547-2018 is examined to explore the general fault response of any DER that follows IEEE 1547-2018. Additionally, an IEEE 1547-2018 compliant inverter model is developed and tested in simulation to find the fault response, and that response is compared with the fault response of a commercial off-the-shelf inverter.

41 EE - Solar Energy Technologies Office (EE-4S)↗

US 2023/0182605 A1 Network constraint energy management system for electric vehicle depot charging and scheduling

Network constraint energy management system for electric vehicle (EV) depot charging and scheduling. In an embodiment, a power schedule is received from an economic dispatch application for a charging depot comprising EV charging station(s) and distributed energy resource(s). The power schedule may be simulated on a distribution network model of the charging depot, according to load flow analysis, to determine whether any grid-code violations occur. In response to the detection of violation(s), a constraint may be generated for each violating node, and the economic dispatch application may be re-executed with the constraint(s) to produce a new power schedule, until no violations are detected. When not all load demand can be satisfied by the power schedule, a charging schedule may be adjusted to ensure that critical energy requirements are satisfied. The final power and charging schedules may be used to schedule and control power generation and charging in the charging depot.

Hafiz, Faeza↗

Charging location selection of an incoming electric vehicle for large EV depot infrastructure

As the use of renewable energy resources increases within charging infrastructures, the risk that charging an additional load within the charging infrastructure will create a violation of the applicable grid code also increases. In an embodiment, a charging location is selected for an incoming load based on a load flow analysis, to thereby mitigate the risk of a violation. This selection process may also account for the charging schedule of the load and the capacity of available charging stations (e.g., fast charging vs. slow charging).

Hafiz, Faeza↗

Validation of blade-resolved computational fluid dynamics for a MW-scale turbine rotor in atmospheric flow

In this study, simulation results of two different computational fluid dynamics codes, Nalu-Wind and EllipSys3D, are presented for a wind turbine rotor in complex yawed and sheared inflow. The results are compared to measurements from the DanAero experiments, to validate computed pressures and azimuthal trends. Despite different code methodologies and grid setups, the codes agree well in computed pressures and integrated forces along the blade for all blade azimuthal positions, however with some discrepancy in the very yawed case. Additionally, both codes capture well the azimuthal trends and force levels seen in measurements. Investigation into discrepancies shows that expanding grids before the rotor, lead to smearing of the wind profiles, which is likely the main cause of the differences in the results between the codes. Additionally, omission of the ground constraint cause discrepancies in relative velocity seen by the passing blade, due to an over speeding beneath the rotor.

17 WIND ENERGY↗