Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Robust Optimal Control of Inverter-Based Resources Under Grid-Forming Operation

In this paper, we propose and solve a robust control problem for inverter-based resources under grid-forming operation to regulate the voltage and frequency. One major challenge is to mitigate the effect of unmeasurable load current disturbance, grid and load parametric uncertainties. Moreover, strong coupling between the state variables on both the AC and DC sides, as well as between the modulating control input and the frequency impose additional challenges. To address these challenges, first, a robust control problem is solved at the high level via transformation into an equivalent, but more tractable, optimal control problem. Then, in the middle layer a voltage control law is designed on the one side, and a frequency control law on the other side. Finally, an inverter filter current controller is designed to complete the controller design. Theoretical results are derived to provide stability guarantees for the resulting closed-loop system. Specifically, we show that the inverter current injection error is dissipative, the frequency error is semi-globally asymptotically stable, and the inverter terminal voltage error is globally asymptotically stable, all with provided sufficient conditions. Here, numerical simulation experiments are used to validate the theoretical claims. Furthermore, the developed controller is compared with existing work in literature to show the efficacy of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

A Demand Bidding Model for Multi-Product Industrial Plants

The growing contribution of renewable energy sources has increased volatility and uncertainty in electricity markets, challenging traditional grid operation paradigms. Demand bidding (DB), a market participation model where (large) electricity users communicate their willingness to pay for electricity to the grid operator, was shown in previous work to enhance grid stability and lower generation cost. We present a DB model for multi-product industrial plants, based on an extended optimal power flow problem where the plant dynamics are represented using autoregressive with extra inputs (ARX) models. We compare DB to price-based demand-side management, showing that, under certain assumptions, the two approaches are equivalent, while DB provides more transparency and predictability to the grid operator. A case study based on an industrial air separation unit is discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Delivery-Risk-Aware Flexibility Scheduling and Dispatch for Aggregated Flexible Loads

Flexible loads like smart thermostats and water heaters can shift energy consumption and provide flexibility to the grid. However, this flexibility is dependent on occupant behavior and can lead to delivery risk, which causes utilities and grid operations to consider them as unreliable for purposes of grid operation. To date, they have not been well integrated into wholesale electricity markets or ancillary service offerings. With proper consideration of uncertainty and risk, these resources can be one of the most cost-effective sources of flexibility. This work uses stochastic optimization to quantify and bid flexibility from a fleet of flexible resources while considering their delivery risk.

DER↗

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗

SNNPG: Using Spiking Neural Networks to Detect Attacks in the Power Grid

We explore the potential of Spiking Neural Networks (SNN) to enhance the security of power grid operations by detecting False Data Injection (FDI) attacks. These attacks manipulate PMU readings, leading to erroneous control decisions and grid disruptions. We develop a method to convert Phase Measurement Unit (PMU) data into spike trains, capturing both temporal and spatial dimensions. Using an SNN model, we conduct evaluations with simulated power grid data, showcasing accuracy in detecting FDI attacks. SNN models rapidly identify anomalies in real-time PMU data, safeguarding grid operations by alerting operators to irregular readings and preventing incorrect decisions.

artificial intelligence↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗