Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid regulation services”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Distribution Grid Management in the Presence of Distributed Energy Resources

The global concerns over climate change, government policies, and incentives in support of distributed energy resources (DERs) are accelerating the growth of DERs in distribution networks. The growth in DER penetration levels can create various issues such as over/under voltages, reverse power flows, overloading, and protection miscoordination. State-of-the-art grid automation solutions such as advanced distribution management systems (ADMS) and distributed energy resource management systems (DERMS) can leverage the DERs to improve distribution grid operations. The ADMS offers advanced grid management functions such as Volt-VAR optimization (VVO), fault management, and outage management to the distribution operator to improve situational awareness and optimize network operations. The DERMS solutions aggregate the small-scale BTM DERs to provide grid services including demand response, voltage regulation, and situational awareness. In this presentation, distribution grid management approaches in the presence of DERs using ADMS and DERMS will be discussed.

ADMS↗

A Hybrid Optimization and Deep Learning Algorithm for Cyber-Resilient DER Control

With the proliferation of distributed energy resources (DERs) in the distribution grid, it is a challenge to effectively control a large number of DERs resilient to the communication and security disruptions, as well as to provide the online grid services, such as voltage regulation and virtual power plant (VPP) dispatch. To this end, a hybrid feedback-based optimization algorithm along with deep learning forecasting technique is proposed to specifically address the cyber-related issues. The online decentralized feedback-based DER optimization control requires timely, accurate voltage measurement from the grid. However, in practice such information may not be received by the control center or even be corrupted. Therefore, the long short-term memory (LSTM) deep learning algorithm is employed to forecast delayed/missed/attacked messages with high accuracy. The IEEE 37-node feeder with high penetration of PV systems is used to validate the efficiency of the proposed hybrid algorithm. The results show that 1) the LSTM-forecasted lost voltage can effectively improve the performance of the DER control algorithm in the practical cyber-physical architecture; and 2) the LSTM forecasting strategy outperforms other strategies of using previous message and skipping dual parameter update.

cyber-resilient algorithm↗

Fast Frequency Response using Reinforcement Learning-Controlled Wind Turbines

To fulfill the auxiliary grid services such as load regulation, spin and non-spin reserve, and frequency support during emergencies, power system operators often require certain wind farms to operate in de-loaded modes. By leveraging the fast response capability of wind farms, the reserved power in deloaded modes can significantly enhance the stability and reliability of power grids. This paper presents a novel methodology that incorporates wind turbines into reinforcement learning-based solutions for frequency response. The proposed approach employs the state-of-the-art reinforcement learning algorithm, surrogategradient- based evolution strategy (GSES), for continuous control of the wind farm output. Our methodology is tested on a modified IEEE-39 bus system, and simulation outcomes demonstrate that the proposed approach can reliably support the frequency of the power system and prevent unnecessary load shedding.

Gao, Wei↗

Deep Reinforcement Learning Based Control of Wind Turbines for Fast Frequency Response

In order to fulfill vital auxiliary grid services, such as load regulation, spin and non-spin reserve provision, and frequency support during emergencies, there is often a requirement for certain wind farms to operate in de-loaded modes. Leveraging the swift response capabilities of wind farms, this study demonstrates that reserving power in de-loaded modes can significantly enhance power grid stability and reliability during system contingencies. Controlling wind farms optimally for frequency support is intricate due to the nonlinearity of models and controllers and the complexity of wind farm interactions with power systems. Here, to address this challenge, this paper introduces a novel approach that integrates wind turbines into reinforcement learning-based solutions for frequency response. This innovative methodology utilizes the state-of-the-art reinforcement learning algorithm known as the surrogate-gradient-based evolutionary strategy. The proposed learning-based algorithm provides continuous control of wind farm output to rapidly stabilize system frequency and prevent unnecessary trips of under-frequency load shedding relays. To facilitate efficient training, parallel computing techniques are employed. The proposed methodology is evaluated on a modified IEEE-39 bus system, and simulation results reveal its efficacy in reliably supporting power system frequency and preventing the need for unnecessary load shedding.

Gao, Wei [Argonne National Laboratory (ANL), Argon↗

Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads

Coordinated control of electric loads can provide valuable grid services, such as frequency regulation. However, due to the nonlinear characteristics of such load ensembles, it is important to systematically analyze their behavior and establish a thorough understanding of undesirable phenomena that can potentially arise. In this paper, we analyze the frequency response of an aggregate control scheme, with the goal of exploring controller performance limits. We show that rapid switching commands can induce oscillations in the power output due to the inherent lockout mechanism of the underlying devices. Here, we demonstrate that highly detailed aggregate models are required to capture such phenomena. Such models enable deeper understanding of the control boundaries and therefore play an important role in avoiding the introduction of undesirable effects on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From Cell to System: Accelerated hpc Simulations of BESS Aging under Frequency Regulation and Arbitrage use cases

Lithium-ion battery energy storage systems (BESS) packs have emerged as a leading solution for grid-scale energy storage, enhancing resiliency and balancing load fluctuations. Yet, experimental characterization of large-format LIB packs-particularly to assess performance and degradation over hundreds of cycles - demands substantial hardware investment and multi-year testing campaigns. In this work, we couple a hierarchical, physics-based modeling framework agnostic to electrode chemistries with high-performance computing to accelerate systems level evaluation by upto two orders of magnitude. Building on the open-source liionpack platform, we implement cell, module, and pack-scale electrochemical models enriched with mechanistic aging mechanisms and deploy them on an HPC cluster to simulate 150−200kWh systems over 500 - 1,000 cycles with in days. We subject these virtual B ESS to both constant-current cycling and realistic grid service profiles spanning frequency regulation, ramp-rate support, and energy arbitrage-and quantify the resulting degradation patterns. Our results reveal that localized cell aging can induce substantial nonuniformity at module and pack levels, with service-specific cycling protocols driving distinct aging modes. This rapid, multiscale modeling approach provides a powerful design-space exploration tool for optimizing electrical architecture, control strategies, and operational schedules to prolong pack lifetime and lower total cost of ownership.

Ayalasomayajula, Surya [ORNL] (ORCID:0009000860788↗

Optimized allocation method of the VSC-MTDC system for frequency regulation reserves considering the cost

In recent years, the interconnection of asynchronous power grids through the VSC-MTDC system has been proposed and extensively studied in light of the potential benefits of economical bulk power exchanges and frequency regulation reserves sharing. This paper proposed an optimized allocation method for sharing frequency regulation reserves among the interconnected power systems and the corresponding frequency regulation control of the VSC-MTDC system under emergency frequency deviation events. Firstly, the frequency regulation reserve classification is proposed. In the classification, the available frequency response capacity reserves of each interconnection are divided into commercial reserves and regular reserves. While the commercial reserves are procured through long-term contracts, the regular reserves are purchased based on market prices of frequency regulation services. Secondly, based on the proposed frequency regulation reserve classification, a novel frequency regulation control is then introduced for the VSC-MTDC system. This control method could minimize the costs of the disturbed power grid for the needed frequency response supports from the other power grids. Simulation verifications are performed on a modified IEEE 39 bus system and a highly reduced power system model representing the North American grids. The simulation verification indicates that the developed frequency regulation control significantly reduced ancillary service costs of the disturbed power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

Enabling DER Participation in Frequency Regulation Markets

Distributed energy resources (DERs) are playing an increasing role in ancillary services for the bulk grid, particularly in frequency regulation. In this article, we propose a framework for collections of DERs, combined to form microgrids and controlled by aggregators, to participate in frequency regulation markets. Our approach covers both the identification of bids for the market clearing stage and the mechanisms for the real-time allocation of the regulation signal. The proposed framework is hierarchical, consisting of a top layer and a bottom layer. The top layer consists of the aggregators communicating in a distributed fashion to optimally disaggregate the regulation signal requested by the system operator. The bottom layer consists of the DERs inside each microgrid whose power levels are adjusted so that the tie line power matches the output of the corresponding aggregator in the top layer. The coordination at the top layer requires the knowledge of cost functions, ramp rates, and capacity bounds of the aggregators. We develop meaningful abstractions for these quantities respecting the power flow constraints and taking into account the load uncertainties and propose a provably correct distributed algorithm for optimal disaggregation of regulation signals among the microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Wind Controls: A Research Roadmap for Microgrids, Infrastructure Resilience, and Controls Launchpad (MIRACL)

The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project’s controls research area aims to expand the benefits from distributed wind (DW) generation assets beyond solely providing low cost power directly to consumers. To make distributed wind turbines operate more effectively there is a need for more advanced ways to control them, allowing power companies, businesses, and energy consumers to take advantage of the unique characteristics of wind energy. DW can contribute to the safe and secure operation of grid by providing services such as voltage regulation, frequency regulation, spinning reserves, and even black start capabilities. In the larger DER context where much of the research has focused around solar technologies, the inertia available in wind technologies has generally not been considered. For wind turbines to provide these services in an optimal and expanded way, development and demonstration of control methods and communication interfaces within a grid and microgrid framework are required. In this document, NREL led the literature review in collaboration with SNL, of DER controls-focused integration research to establish a baseline for the controls research under the MIRACL project to identify specific control functions to be focused on throughout this project. This literature review focused primarily on the control functions of variable distributed generation, largely pulling from past solar PV and battery controls works, with a specific focus on applicability for distributed wind energy systems. The goal of this document is to identify a research roadmap based on the open literature and past national laboratory works to inform advanced wind turbine and power electronics control functions for four use cases: 1) distributed wind in isolated systems, 2) grid-connected microgrids (wind-hybrid systems and islanded operation), 3) behind-the-meter distributed wind applications in the power distribution systems, and 4) front-of-the-meter distributed wind applications in the power distribution systems.

17 WIND ENERGY↗

Reducing Grid Costs while Abating Emissions: Opportunities for Flexible Building Loads

This study evaluates the value of technology-agnostic, shiftable flexible building loads in modeled 2030 and 2040 U.S. grids for four types of customers under three potential aggregated distributed energy resources programs. The value examined includes monetary value from providing grid services (e.g., energy, capacity, flexibility reserve, regulation reserve, contingency reserve) and from reducing greenhouse gas emissions. By comparing more than 845,164,800 simulated shifting opportunities, the study finds that the timing of consumption is critical for profit-driven customers. A program that is activated for 30 critical hours of system operation can result in to $73 per year in revenue for 1 kWh of shiftable load. Emission reduction, on the other hand, is best accumulated through a year-round program: 1 kWh of shiftable load can lead to up to 487.9 kg CO2e carbon reduction per year. The report also provides detailed insights on the trade-off between revenue and emissions, regional variation, short- versus medium- term value, and impacts from various building flexibility parameters, such as shifting window and dissipation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Topological Machine Learning Methods for Power System Responses to Contingencies: Preprint

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remain untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topologybased system that depends on neural network architecture for impact metrics classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, namely, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates both more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn complex relationships between electrical properties and local topological measurements on the simulated response to contingencies for NREL-SIIP power system.

graph theory↗