Dynamic Leaching Method for Intact Salt-stone Samples - 18495

At the Savannah River Site (SRS) low activity salt solution is stabilized via encapsulation within a grout termed salt-stone. Salt-stone is emplaced into large (multi-million liter) concrete storage containers referred to as Salt-stone Disposal Units (SDUs). Technetium-99 (Tc-99) and iodine-129 (I-129) are long-lived radionuclides contained in the low activity salt waste and subsequently incorporated into the grout waste form: both radionuclides are contributors to the potential long-term radiation exposure of the public and environment surrounding the SDUs. With respect to Tc-99, in the reducing, high pH environment within the grout, Tc-99 is expected to be relatively immobile since it exists in a reduced Tc(IV) oxidation state in the form of sparingly soluble hydrated oxides (TcO{sub 2}.xH{sub 2}O) or sulfides (TcS{sub x}). However, in the presence of O{sub 2} (associated with the future infiltration of air or oxygenated ground waters into the salt-stone monolith) it is possible for redox-sensitive Tc(IV) to transition into highly soluble (and mobile) Tc(VII) species, such as pertechnetate (TcO{sub 4}{sup -}), which are more readily transported to the surrounding environment. In contrast, I-129 is highly soluble and its leaching behavior is not anticipated to be significantly impacted by potential changes in redox environment or pH within salt-stone. Traditional approaches to quantifying the leaching behavior of Tc-99 and I-29 from cementitious matrices have involved partitioning experiments using size-reduced (crushed/ground) samples, and determination of the radionuclide fraction immobilized by the cementitious solids. Such experiments create artificially high solid-liquid contact areas that likely result in higher Tc-99 and I-129 leachate concentrations than would be expected for intact, monolithic samples. In the current study a new technique, termed the Dynamic Leaching Method (DLM), is being used to initially investigate the Tc-99 leaching behavior from monolithic salt-stone samples; the system will be used at a later date to evaluate the leaching characteristics of I-129. The data derived using this technique is intended to inform the SRS Salt-stone Disposal Facility (SDF) Performance Assessment (PA) which models the long-term transport of radionuclides from the SDUs to the environment. The DLM utilizes a flexible-wall permeameter to achieve saturated leaching under an elevated hydraulic gradient to simulate and accelerate the future transport of groundwater through salt-stone. Leachates are regularly analyzed with respect to radionuclide concentrations, key constituent concentrations (e.g., Al, Ca, Mg, Na, Si, CO{sub 3}{sup 2-}, NO{sub 2}{sup -}, NO{sub 3}{sup -}, SO{sub 4}{sup 2-}), pH, and reduction potential (E{sub h}) in order to develop an understanding of how chemical changes associated with the pore solution influence grout weathering and radionuclide leaching behavior. This paper provides a brief update with respect to data derived from preliminary Tc-99 leaching evaluations as the DLM was being developed, but the paper is predominantly focused on new sample data in which the DLM technique, pre- and post-DLM salt-stone sample characterization, and leachate analysis protocols have been optimized. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ETF Grout Expansion: Evaluation of MgO Additions and Struvite Precipitation Protocol for Potential Expansion

The ETF ammonia tolerant grout waste form was developed by the Vitreous State Laboratory (VSL) to stabilize ammonium and thereby prevent emission of ammonia vapor during solidification of an ammonium-rich, concentrated sulfate aqueous waste stream generated at the Hanford Effluent Treatment Facility (ETF). VSL did not observe expansion in samples prepared during the waste form development work. However, Savannah River National Laboratory (SRNL) personnel did encounter expansion, in some cases up to 20+ volume percent expansion in ETF grout samples while preforming work scope to evaluate compositional ranges for ETF brine and of the precipitation and solidification reagent. The work requests can be found in Washington River Protection Services (WRPS) Statement of Work (SOW), Requisitions #: 339922 Revisions 0 and 1, March 11, 2021, and November 2021. Additional evaluation was requested by WRPS SOW Requisitions #: 356730, Revision 1, February 1, 2022, to determine whether differences in the slags or differences in sample preparation protocols used by VSL and SRNL were the cause of the expansion observed in the SRNL samples. G. Chen, WRPS, arranged a materials exchange between VSL and SRNL and coordinated the VSL protocol for grouting and curing 1L of Base Case ETF simulant. Materials were exchanged between VSL and SRNL and both laboratories performed the VSL struvite precipitation-solidification protocol and cured samples for at least 28 days. VSL and SRNL encountered expansion, at varying degrees, in all samples prepared under the material exchange and grouting protocol. Additional material exchange testing between VSL and SRNL and alternative materials evaluation to further investigate the causes of grout expansion and differentiate the effects of various dry materials, grouting procedures, and curing containers was requested by WRPS SOW Requisitions #: 356730, Revision 2, January 10, 2023. Pacific Northwest National Laboratory (PNNL) assembled and distributed materials to both laboratories for testing. Observations from this study indicated variations in MgO additions, water-to-dry mix (dm) ratios and curing containers did not correlate to ETF ammonia grout expansion. In comparison to previous work, SRNL observed the addition rate of NaOH to be a potential factor for the final pH in the struvite precipitation step. In the current testing NaOH was added in bulk (5-10 mL at one time) during the precipitation step. The resulting pH was 7.57-9.15 which is slightly higher than pH observed at a slower addition rate. Additional testing is needed to identify the presence and/or struvite stability in high-pH struvite precipitant ETF ammonia grout samples. Therefore, based on current data, it is unknown if NaOH addition rate is the fundamental cause of grout expansion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Metric for Cementitious Waste Form Inventory Release in the Integrated Disposal Facility

This report describes work supporting Phase 1 of the 2018 Department of Energy (DOE) Office of River Protection’s (ORP) Grand Challenge recipient proposal “Cementitious Immobilization of Treated LAW and Ancillary Benefits to Risk Reduction in Cross Site Transfer”. Phase 1 was to establish a performance metric for grout leachability against which laboratory leach data (as observed diffusivities) can be assed, followed by a comparison of historical test data against this metric. Historically, advancements in the cementitious (grout) waste form performance have been made over the last 40 years, with the majority of progress achieved within the past 8 years as part of the Washington River Protection Solutions, LLC testing program. This report presents a summary of that effort relevant to the Hanford Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Operational and Compositional Factors that Affect the Performance Properties of ARP/MCU Saltstone Grout

The Saltstone Production Facility (SPF) receives low level waste (LLW) salt solution from Tank 50H for treatment and disposal. Tank 50H receives transfers from the Effluent Treatment Project (ETP), the H-Canyon General Purpose Evaporator, and the Actinide Removal Process/Modular Caustic Side Solvent Extraction Unit (ARP/MCU) Decontaminated Salt Solution Hold Tank (DSS-HT). At the SPF, the LLW is mixed with premix (a cementitious mixture of portland cement (PC), blast furnace slag (BFS) and Class F fly ash (FA)) in a Readco mixer to produce fresh (uncured) saltstone that is transferred to the Saltstone Disposal Facility (SDF) vaults. The saltstone formulation (mix design) must produce a grout waste form that meets both placement and performance properties. In previous simulated saltstone studies, multiple compositional factors were identified that drive the performance properties of saltstone made from the projected ARP/MCU salt solution. This composition was selected as salt solution simulant since ARP/MCU is the primary influent into Tank 50H. The primary performance property investigated was hydraulic conductivity since it is a variable input property to the saltstone Performance Assessment (PA) transport model. In addition, the porosity, also referred to as void structure, is another variable that impacts the PA response. In addition, Young's modulus and cured density are other performance properties analyzed in this report; however they are indicators of the performance of saltstone and not direct inputs into the PA. The data from previous studies showed that the largest impact on the performance properties of saltstone was due to curing temperature, followed by aluminate concentration in the salt solution, water to premix ratio and premix composition. However, due to the scope of the previous studies, only a few mixes were cured and analyzed at higher temperatures. The samples cured at 60°C had an increased hydraulic conductivity of approximately 600 times that of the sample cured at room temperature. The hydration reactions initiated during the mixing of the premix and salt solution continue during the curing period in the vaults to produce the hardened waste form product. The heat generated from exothermic hydration reactions results in a temperature increase in the vaults that depends on the composition of the decontaminated salt solution being dispositioned, the grout formulation (mix design) and the pour frequency and volume. This heat generation is a contributing factor to the temperature increase in the vaults that leads to an increased cure temperature for the grout. This report will further investigate the impact of curing temperature on saltstone performance properties (hydraulic conductivity, Young's modulus, porosity, etc.) over a range of aluminate concentration, water to premix (w/p) ratio and weight percent fly ash in the premix processed at the SPF. The three curing temperatures selected for this study were chosen to provide data at fixed cure temperatures that represent measured temperatures in the SDF vaults. This does not represent the conditions in the vault where the temperature of the saltstone is continually changing with time. For example, it may take several days for the saltstone to reach 60°C at a given elevation. Previous results demonstrated that the rates at which a selected curing temperature is reached affect the performance properties. The approach taken in this task, a rapid increase to the curing temperature, may be conservative with respect to decreased performance. Nevertheless, the data will provide a basis from which to determine the impact of curing temperature on saltstone performance as a function of key variables. A statistical evaluation of the results for these mixes will be performed to provide the range, and associated uncertainties, of hydraulic conductivity and other properties over this factor space.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Curing Temperature and Composition on the Performance Properties of Saltstone - 12473

When freshly mixed Saltstone is placed into a vault at the Savannah River Site, the heat of hydration produced during curing causes the temperature of the grout to increase. It is not uncommon for the temperature of the grout to increase by 30 to 50 deg. C above the starting temperature depending on the vault size and location, environmental conditions and pour schedule. For example, temperatures measured by thermocouples in one cell have exceeded 70 deg. C. The elevated temperatures, once reached, can extend for weeks or even months. Recent studies at Savannah River National Laboratory (SRNL) have shown that curing simulated Saltstone mixes at elevated temperatures can lead to reduced compressive strength and dynamic Young's modulus as well as increased total porosity when compared to the same grout mixes cured at 20 deg. C. Samples cured at 60 deg. C can have hydraulic conductivities approximately 600 times greater than samples cured at 20 deg. C. Previous studies have shown that the 60 deg. C cured mix had a dynamic Young's modulus that was half that of the mix cured at 20 deg. C. However, high temperature curing may not always have negative effects on the performance properties of the grout. These results indicate that higher curing temperatures can significantly alter the performance properties that are inputs for the Saltstone Performance Assessment. The Saltstone formulation (mix design) must produce a grout waste form that meets both placement and performance properties. A statistically designed set of mixes was developed to determine key process and compositional factors that affect the performance properties of Saltstone grout. A total of 27 mixes were batched and tested. There are eight baseline mixes that contain high and low values of aluminate concentration, varying w/p ratio, and varying fly ash content in the premix. Each of the eight mixes was cured at 22, 40 and 60 deg. C. The three additional reference mixes batched at the beginning, middle and end of testing showed good reproducibility throughout the study. The results of varying the operational and compositional factors on the performance properties of Saltstone grout are: - The Young's modulus is inversely affected by the curing temperature of the grout. - The aluminate content of the salt solution increases the Young's modulus of the Saltstone for samples cured at 20 and 40 deg. C. - All grouts cured at 60 deg. C have low Young's moduli and the composition of the grout mix did not have any positive effects on the performance properties after curing at this temperature. - The fly ash content in the premix had not discernible effect on the Young's modulus. - The water to premix ratio does not affect the Young's modulus. - Grouts made with the high aluminate salt solution have lower hydraulic conductivities than those made with the low aluminate simulant. - Temperature has an inverse effect on the hydraulic conductivity. - In general, increasing the water to premix ratio and the fly ash content will increase the hydraulic conductivity. - The porosity and cured density of the Saltstone grout are primarily a factor of the water to premix ratio of the grout formulation. The correlation between hydraulic conductivity and Young's modulus investigated in previous studies was evaluated further in this report. The current data as well as data from previous studies was fitted by a second degree polynomial function with a 77.1 % R-squared value. This model can be used to estimate the hydraulic conductivity of a sample based its Young's modulus for a limited range (E values up to 7 GPa). More data points should be included to further define the relationship between these performance properties are high Young's moduli and low hydraulic conductivities. The Young's modulus should still be measured on grouts formulated in future studies to be used as screening method for samples to be sent for hydraulic conductivity measurements. Saltstone grout has a complicated microstructure that is affected by the composition of the salt solution, the dry feed mixture composition, and the conditions under which it cures. The performance properties investigated are interrelated, which can make it difficult to determine individual relationships between various factors. Porosity is a large factor in determining both the Young's modulus and the hydraulic conductivity of the samples. Although the cured density is a straightforward measurement, it is not a significant performance property that needs further investigation. The porosity measurement provides similar and more meaningful data in relation to other performance properties. Based on the results of this study, the aluminate content of the salt solution does have an effect on the Young's modulus and the hydraulic conductivity and its effects should continue to be investigated. However, a new projection of aluminate contents should be used since projections change over time. The variability of fly ash in the premix did not prove to be a contributing factor that effects the performance properties of Saltstone and does not need to be included in future studies unless significant deviations from the baseline mix are proposed. The water to premix ratio has a significant effect on the performance properties of interest and the effects of varying this factor need further investigation. It is recommended that smaller ranges of w/p are investigated in order to provide data that is more relevant to the Saltstone being placed in the vaults. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration of SuperLig{sup R} 605 and SuperLig{sup R} 644 in a Regeneration Flow Sheet to Remove Radioactive Strontium and Cesium from Seawater - 16236

Remediation techniques are needed for efficient removal of radioactive strontium and cesium from seawater. Molecular Recognition Technology, using selective SuperLig{sup R} resins, demonstrates a clean chemistry approach to solving this problem. Molecular Recognition Technology offers high levels of separation of chemically pure metal contaminants, whose subsequent disposal is compatible with simple waste forms (grout and glass). SuperLig{sup R} resins can be regenerated with common reagents and used many times, limited by a dose of 1 E+9 Rad, which assures low volumes of secondary solid waste. The metal selectivity of the SuperLig{sup R} resin ensures that the solid waste is of low residual activity. These properties of sustainability are illustrated in a project that demonstrated the ability of two SuperLig{sup R} resins to selectively remove Cs and Sr from a seawater mimic representative of the contaminated seawater in Fukushima, Dai'ichi, Japan harbor. Removal of radioactive Sr-90 and Cs-134/Cs-137 from seawater using conventional ion exchange or a complexing agent is complicated by the presence of large excesses of competing ions such as Na, K, Ca, and Mg, which can be co-extracted. These competing ions, if co-extracted, reduce the capacity of a single pass resin with the consequent increase in volume of spent resin or decrease in capacity of a regenerable resin. The successful demonstration reported in this study has shown the ability of two proprietary resins, SuperLig{sup R} 605 and SuperLig{sup R} 644, to remove Sr and Cs, respectively, with high selectivity from simulated solutions containing these metal ions together with major constituents of seawater at their normal concentrations. This effort was part of a demonstration project to investigate methods for removal of Sr-90 and Cs-134/Cs-137 from 160,000 cubic meters of seawater impounded at Fukushima, Dai'ichi, Japan harbor. SuperLig{sup R} resins can be regenerated by elution with small volumes of simple acid solutions. SuperLig{sup R} resins have a high tolerance to radiation, with their performance not being degraded by doses of 1.0 E+9 Rad. Estimates, based on the results obtained, are that Cs and Sr levels in the volume of seawater in the Fukushima, Dai'ichi, Japan harbor could be reduced to desired discharge limits in 200 days with some 30 cubic meters of the two SuperLig{sup R} resins and that decontamination factors of 10 or more could be achieved. Results of the demonstration, together with advantages of the Molecular Recognition Technology process over conventional procedures for these separations are presented and discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Chemistry Envelope for the Determination of Pitting Corrosion Susceptibility - 19554

Liquid radioactive wastes at the Hanford and Savannah River sites are stored in large underground carbon steel tanks. The high-level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life (i.e., greater than 60 years). Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. Administrative programs are in place to mitigate potential corrosion mechanisms and thereby maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. Waste chemistry and temperature control are the means by which corrosion degradation of the waste tanks is minimized. Chemistry controls are based on in-situ coupon tests, waste tank experience, and laboratory testing. These requirements comprise the technical standards for corrosion control. The standards are utilized then as guidelines for operational procedures. The present waste chemistry controls for the Hanford DSTs were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the DOE Savannah River Site (SRS). Portions of the SRS chemistry limits, which were developed at the Savannah River National Laboratory (SRNL) were coupled with corrosion testing results from Pacific Northwest National Laboratories (PNNL) and adopted for corrosion control of the double-shell tank (DST) waste at the Hanford Site. Since that time, the temperatures of the waste in the DSTs have decreased to less than 50 deg. C in most cases as the radioactive material has decayed. As a consequence, new chemistry controls were formulated for SCC in 2010. This testing however, did not address that potential for pitting in the supernatant and at the liquid-air interface. Indeed, initial tests indicated that the inhibitor requirements for SCC would be insufficient for the prevention of pitting. In addition to lower waste temperatures, future retrieval and process changes may impact the DST waste chemistry. Initial projections suggest that the waste chemistry of the DSTs may shift to a broader range of pH and higher aggressive anion concentrations (e.g., chloride, sulfate, etc.) than the wastes that are presently stored. Additionally, processes within the vitrification facility may result in streams that are returned to the tank farm for evaporation. These streams may also contain high concentrations of aggressive species. SRNL investigated the propensity for pitting of the carbon steel waste tanks at current and projected DST waste chemistries. A statistically designed series of tests provided a pitting factor that relates the ratio of the inhibitor species to the aggressive species and the probability of observing pitting. An acceptable pitting factor was determined and was utilized for the development of a new chemistry envelope. The new chemistry envelope was compared to the envelope that was established for SCC and was determined to be bounding. Validation of the new chemistry envelope was performed via model simulations and comparison with historical experimental results and approaches to establishing chemistry envelopes. The new chemistry envelope will eventually be part of an overall assessment of the condition of the tanks and any changes made to the overall structural integrity program for the Hanford DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Presence of aromatic-rich organic matter and its characterization in grout materials: Implications for radionuclide immobilization

Grout materials are commonly used to immobilize low-level radioactive waste. Organic moieties can be unintentionally present in common ingredients used to make these grout waste forms, which may result in the formation of organo-radionuclide species. These species can positively or negatively affect the immobilization efficiency. However, the presence of organic carbon compounds is rarely considered in models or characterized chemically. Here, we quantify the organic pool of grout formulations with and without slag, as well as the individual dry ingredients used to make the grout samples (ordinary Portland cement (OPC), slag and fly ash), including total organic carbon (TOC) and black carbon, followed by aromaticity evaluation and molecular characterization via Electro Spray Ionization Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (ESI-FTICRMS). All dry grout ingredients contained significant amounts of organic carbon, ranging from 550 mg/kg to 6250 mg/kg for the TOC pool, with an averaged abundance of 2933 ± 2537 mg/kg, of which 60 ± 29% was composed of black carbon. The significant abundance of a black carbon pool implies the presence of the aromatic-like compounds, which was further identified by both phosphate buffer-assisted aromaticity evaluation (e.g., >1000 mg-C/kg as aromatic-like carbon in the OPC) and dichloromethane (DCM) extraction with ESIFTICRMS analysis. Besides aromatic-like compounds, other organic moieties were also detected in the OPC, such as carboxyl-containing aliphatic molecules. While the organic compound only consists of minor fractions of the grout materials investigated, our observations of the presence of various radionuclide-binding organic moieties suggests the potential formation of organo-radionuclides, such as radioiodine, which might be present at lower molar concentrations than TOC. Here, evaluating the role of organic carbon complexation in controlling the disposed radionuclides, especially for those radionuclides with strong association with organic carbon, has important implications for the long-term immobilization of radioactive waste in grout systems.

36 MATERIALS SCIENCE↗

In-service inspection of radioactive waste tanks at the Savannah River Site - 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks, will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Secondary Waste Cementitious Waste Form Data Package for the Integrated Disposal Facility Performance Assessment

A review of the most up-to-date and relevant data currently available was conducted to develop a set of recommended values for use in the Integrated Disposal Facility (IDF) performance assessment (PA) to model contaminant release from a cementitious waste form for aqueous wastes treated at the Hanford Effluent Treatment Facility (ETF). This data package relies primarily upon recent data collected on Cast Stone formulations fabricated with simulants of low-activity waste (LAW) and liquid secondary wastes expected to be produced at Hanford. These data were supplemented, when necessary, with data developed for saltstone (a similar grout waste form used at the Savannah River Site). Work is currently underway to collect data on cementitious waste forms that are similar to Cast Stone and saltstone but are tailored to the characteristics of ETF-treated liquid secondary wastes. Recommended values for key parameters to conduct PA modeling of contaminant release from ETF-treated liquid waste are provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Mercury in the SRS Tank Waste Storage and Treatment Processes for Applicability to Hanford Waste Processing

The Savannah River Site (SRS) and Hanford produced large quantities of plutonium and other radioisotopes. The separations processes recovered plutonium and produced large quantities of High- Level Waste (HLW) that accumulated at each site in large, underground storage tanks. SRS has been retrieving the stored HLW, pretreating the waste for immobilization, and immobilizing the waste in glass or grout waste forms since the mid-1990s. Treatment of the waste at Hanford is expected to start in the early 2020s. Mercury is present in both the SRS and Hanford tank waste. SRS has recently completed an evaluation of mercury speciation throughout the tank waste treatment and immobilization flowsheet. This study was reviewed to determine what information from the study can be applied to the Hanford tank waste treatment program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Hanford ETF Grout Evaluation Report

The Hanford Effluent Treatment Facility (ETF) ammonia tolerant grout waste form was developed by the Vitreous State Laboratory (VSL) to stabilize ammonium and thereby prevent emission of ammonia vapor during processing of a final cementitious waste form. This ETF evaporator bottom waste is a concentrated sodium sulfate aqueous solution that also contains dissolved ammonium. The VSL waste form was produced in a two-step process in which struvite (MgNH 4 PO 4.6 H 2 O) is precipitated and then the resulting slurry is solidified in a cementitious matrix. SRNL researchers were tasked to evaluate the effect of compositional and struvite stability in simulated ETF evaporator brine. In 2022 to 2023, samples prepared by SRNL experienced significant expansion (up to 20 volume %) which was not observed by VSL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Formulation of Cast Stone for {sup 99}Tc Immobilization in Sulfate Rich Secondary Waste Stream - 16098

A low-temperature, cementitious waste form called Cast Stone (or grout) has been selected for solidification of the Effluent Treatment Facility (ETF)-treated wastes at the Hanford Site. Because the waste stream to be solidified may be relatively high in sulfate, the current Cast Stone dry blend formulation with ordinary Portland cement (OPC), fly ash (FA), and blast furnace slag (BFS) (47% BFS, 45% FA, and 8% OPC) may not be adequate. Thus a new formulation, called secondary waste grout, was proposed and tested. The secondary waste grout uses hydrated lime [Ca(OH){sub 2}] to tie up the sulfate initially such that ettringite [Ca{sub 6}Al{sub 2}(SO{sub 4}){sub 3}(OH){sub 12}.26(H{sub 2}O)] forms rapidly instead of forming as the cementitious waste form cures. Three different liquid waste simulants (242-A evaporator, Environmental Restoration Disposal Facility [ERDF] leachates, and Hanford Tank Waste Treatment and Immobilization Plant [WTP] off-gas condensates) were prepared and solidified using this new dry blend formulation. Baseline grout dry mixes were 20 wt% hydrated lime (HL), 35 wt% OPC, and 45 wt% BFS, and two different water-to-dry mix (w/dm) ratios (0.5 and 0.6) of free water mass to mass of dry blend were tested. After curing for a minimum of 28 days, the grout solidified waste forms were characterized and used for Tc leachability testing using the EPA 1315 Method. X-ray diffraction analysis confirmed that ∼12-15% of ettringite was formed in early stage of 28-day curing for the grouts prepared with the high sulfate WTP simulant and HL addition. In addition, the new formulation of secondary waste grout prepared with HL (20%), OPC (35%), and BFS (45%) at either 0.5 or 0.6 water to dry mix ratio yields higher average Tc interval leachability index (LI) values (12.5 to 13.9) after 28 to 90 days of leaching using deionized water, which is higher than the desired {sup 99}Tc LI value of 12 for grout destined for burial in the Integrated Disposal Facility at the Hanford Site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model Package Report: Composite Analysis Solid Waste Release Model (CASWR Model)

This document describes the implementation of a solid waste form release model in GoldSim for the Hanford Site Composite Analysis (CA) Update. This Composite Analysis Solid Waste Release model (CASWR model) was designed to generate deterministic radionuclide release rates for Hanford’s Central Plateau solid waste disposal sites using single realizations of release model coefficients. Five generalized waste form types are used for the conceptual model of waste release: surplus reactor block, cement, soil-debris, grouted residual waste, and ancillary equipment. The surplus reactor block waste form consists of radionuclide leaching from surplus production graphite reactor core blocks via unspecified processes (White et al., 1984 as cited in PNNL-15965). The cement waste form represents solidified wastes whose permeability is much lower than that of the surrounding soil. The soil-debris waste form type is defined as unconsolidated waste mixed with soil material. Tanks and canyon complexes comprise the grouted residual waste form such that their solid waste will be grouted and capped with a surface barrier at the completion of their cleanup. Finally, the ancillary equipment waste form constitutes contaminant releases from ancillary and auxiliary waste form residues associated with tank farms at closure. Individual sub-models are implemented to numerically represent a respective waste form within the CASWR Model: Surplus Reactor Block Sub-model, Cement Sub-model, SoilDebris Sub-model, Grouted Residual Waste Sub-model, and Ancillary Equipment Submodel. Advection is assumed to be the primary transport process governing the release of radionuclides in the Ancillary Equipment and Soil-Debris Sub-models. Diffusion is assumed to be the primary release process in the Grouted Residual Waste and Cement Sub-models. An unspecified zero-order release process is considered in the Surplus Reactor Block Sub-model due to the lack of information regarding actual processes involved in irradiated graphite leaching. The Surplus Reactor Block, Cement, and SoilDebris Sub-models were compared against analytical solutions (PNNL-11800, Composite Analysis for Low-Level Waste Disposal in the 200 Area Plateau of the Hanford Site). The agreement between results of these analytical solutions and the corresponding waste form models verified their correct implementation in GoldSim. A 1-D modeling abstraction approach for the Grouted Residual Waste and Ancillary Equipment Sub-models was adopted from existing Performance Assessment (PA) models. Despite the simplifications made in these sub-models, they were found to be appropriate representations of the waste forms, similar to what was used in the Waste Management Area C PA model (RPP-ENV-58782, Performance Assessment of Waste Management Area C, Hanford Site, Washington, Rev. 0). A sensitivity analysis was conducted to identify the most influential parameters in each waste form sub-model. Suggestions for considering pH-dependent and redox-dependent release mechanisms are formulated through the development of a conditional constant approach in GoldSim.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updated Liquid Secondary Waste Grout Formulation and Preliminary Waste Form Qualification

This report describes the results from liquid secondary waste grout (LSWG) formulation and cementitious waste form qualification tests performed by Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions, LLC (WRPS). New formulations for preparing a cementitious waste form from a high-sulfate liquid secondary waste stream simulant, developed for Effluent Management Facility (EMF) process condensates merged with low activity waste (LAW) caustic scrubber, and the release of key constituents (e.g. 99 Tc and 129 I) from these monoliths were evaluated. This work supports a technology development program to address the technology needs for Hanford Site Effluent Treatment Facility (ETF) liquid secondary waste (LSW) solidification and supports future Direct Feed Low-Activity Waste (DFLAW) operations. High-priority activities included simulant development, LSWG formulation, and waste form qualification. The work contained within this report relates to waste form development and testing and does not directly support the 2017 integrated disposal facility (IDF) performance assessment (PA). However, this work contains valuable information for use in PA maintenance past FY17, and for future waste form development efforts. The provided data should be used by (i) cementitious waste form scientists to further understanding of cementitious dissolution behavior, (ii) IDF PA modelers who use quantified constituent leachability, effective diffusivity, and partitioning coefficients to advance PA modeling efforts, and (iii) the U.S. Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program. The results obtained help fill existing data gaps, support final selection of a LSWG waste form, and improve the technical defensibility of long-term waste form performance estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updated Liquid Secondary Waste Grout Formulation and Preliminary Waste Form Qualification

This report describes the results from liquid secondary waste grout (LSWG) formulation and cementitious waste form qualification tests performed by Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions, LLC (WRPS). New formulations for preparing a cementitious waste form from a high-sulfate liquid secondary waste stream simulant, developed for Effluent Management Facility (EMF) process condensates merged with low activity waste (LAW) caustic scrubber, and the release of key constituents (e.g. 99Tc and 129I) from these monoliths were evaluated. This work supports a technology development program to address the technology needs for Hanford Site Effluent Treatment Facility (ETF) liquid secondary waste (LSW) solidification and supports future Direct Feed Low-Activity Waste (DFLAW) operations. High-priority activities included simulant development, LSWG formulation, and waste form qualification. The work contained within this report relates to waste form development and testing and does not directly support the 2017 integrated disposal facility (IDF) performance assessment (PA). However, this work contains valuable information for use in PA maintenance past FY17, and for future waste form development efforts. The provided data should be used by (i) cementitious waste form scientists to further understanding of cementitious dissolution behavior, (ii) IDF PA modelers who use quantified constituent leachability, effective diffusivity, and partitioning coefficients to advance PA modeling efforts, and (iii) the U.S. Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program. The results obtained help fill existing data gaps, support final selection of a LSWG waste form, and improve the technical defensibility of long-term waste form performance estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗