Search NASA⌕ Search

SEARCH · Search NASA

Results for “haptic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Towards an Improved Pilot-Vehicle Interface for Highly Automated Aircraft: Evaluation of the Haptic Flight Control System

The control automation and interaction paradigm (e.g., manual, autopilot, flight management system) used on virtually all large highly automated aircraft has long been an exemplar of breakdowns in human factors and human-centered design. An alternative paradigm is the Haptic Flight Control System (HFCS) that is part of NASA Langley Research Center s Naturalistic Flight Deck Concept. The HFCS uses only stick and throttle for easily and intuitively controlling the actual flight of the aircraft without losing any of the efficiency and operational benefits of the current paradigm. Initial prototypes of the HFCS are being evaluated and this paper describes one such evaluation. In this evaluation we examined claims regarding improved situation awareness, appropriate workload, graceful degradation, and improved pilot acceptance. Twenty-four instrument-rated pilots were instructed to plan and fly four different flights in a fictitious airspace using a moderate fidelity desktop simulation. Three different flight control paradigms were tested: Manual control, Full Automation control, and a simplified version of the HFCS. Dependent variables included both subjective (questionnaire) and objective (SAGAT) measures of situation awareness, workload (NASA-TLX), secondary task performance, time to recognize automation failures, and pilot preference (questionnaire). The results showed a statistically significant advantage for the HFCS in a number of measures. Results that were not statistically significant still favored the HFCS. The results suggest that the HFCS does offer an attractive and viable alternative to the tactical components of today s FMS/autopilot control system. The paper describes further studies that are planned to continue to evaluate the HFCS.

Schutte, Paul↗

Haptic seat for fuel economy feedback

A process of providing driver fuel economy feedback is disclosed in which vehicle sensors provide for haptic feedback on fuel usage. Such sensors may include one or more of a speed sensors, global position satellite units, vehicle pitch/roll angle sensors, suspension displacement sensors, longitudinal accelerometer sensors, throttle position in sensors, steering angle sensors, break pressure sensors, and lateral accelerometer sensors. Sensors used singlely or collectively can provide enhanced feedback as to various environmental conditions and operating conditions such that a more accurate assessment of fuel economy information can be provided to the driver.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Design and Performance of Low Cost Haptic Interfaces to Control Precision Nuclear Robotic System - 18351

Nuclear decommissioning environments are challenging and hazardous, typically involving high temperatures, pressures and extreme radiation. Robotic devices are commonly used to complete tasks within challenging environments, which would otherwise pose a risk to human health, however remotely operating robots without full three-dimensional vision is challenging, and operators of robotic systems require extensive training to enable precise navigation through three-dimensional environments using multiple two-dimensional views for feedback. This project explores the possibility of using a human arm as a master device for controlling a variety of low-cost slave robots, with the aim of reducing training times whilst providing a cheaper, more intuitive control system. Virtual Reality (VR) and haptics are used as an aid for navigation of the remote environment, whilst also providing a digital twin for the operator to enable real-time feedback from the slave robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Haptic stabilization of posture: changes in arm proprioception and cutaneous feedback for different arm orientations

Postural sway during quiet stance is attenuated by actively maintained contact of the index finger with a stationary surface, even if the level of applied force (<1 N) cannot provide mechanical stabilization. In this situation, changes in force level at the fingertip lead changes in center of foot pressure by approximately 250 ms. These and related findings indicate that stimulation of the fingertip combined with proprioceptive information about the hand and arm can serve as an active sensor of body position relative to the point of contact. A geometric analysis of the relationship between hand and torso displacement during body sway led to the prediction that arm and hand proprioceptive and finger somatosensory information about body sway would be maximized with finger contact in the plane of body sway. Therefore, the most postural stabilization should be possible with such contact. To test this analysis, subjects touched a laterally versus anteriorly placed surface while in each of two stances: the heel-to-toe tandem Romberg stance that reduces medial-lateral stability and the heel-to-heel, toes-outward, knees-bent, "duck stance" that reduces fore-aft stability. Postural sway was always least with finger contact in the unstable plane: for the tandem stance, lateral fingertip contact was significantly more effective than frontal contact, and, for the duck stance, frontal contact was more effective than lateral fingertip contact. Force changes at the fingertip led changes in center of pressure of the feet by approximately 250 ms for both fingertip contact locations for both test stances. These results support the geometric analysis, which showed that 1) arm joint angles change by the largest amount when fingertip contact is maintained in the plane of greatest sway, and 2) the somatosensory cues at the fingertip provide both direction and amplitude information about sway when the finger is contacting a surface in the unstable plane.

Non-NASA Center↗

Pneumatic Haptic Interfaces

An instrumentation system for direct measurement of the thermal conductivity of a small sample of a highly insulating material has been devised. As used here, (1) "small" signifies having dimensions of the order of two centimeters - significantly less than the sizes of specimens for which prior devices for direct measurement of thermal conductivity have been designed; and (2) "highly insulating" signifies having thermal conductivity of the order of that of air. The heart of the system is an assembly that includes two copper disks - one electrically heated, the other cooled with chilled water. The disks are separated by a guard ring made of strong, thermally insulating polymethacrylamide foam. The sample fits between the copper disks and within the ring (see figure). Matched thermocouples are used to measure the temperatures of the heated and cooled disks. The heated and cooled disks are affixed to larger foam disks, and the essentially still air in the gap between the larger disks insulates the sides of the specimen. This air gap region can be further divided by extending the foam ring into the gap region. The entire assembly as described thus far is lightly clamped together by means of nylon threaded rods and is placed inside a cylindrical chamber wherein the temperature is maintained at a set value (typically, 25 C).

Bae, Sam Y.↗

Multimodal information Management: Evaluation of Auditory and Haptic Cues for NextGen Communication Displays

Auditory communication displays within the NextGen data link system may use multiple synthetic speech messages replacing traditional ATC and company communications. The design of an interface for selecting amongst multiple incoming messages can impact both performance (time to select, audit and release a message) and preference. Two design factors were evaluated: physical pressure-sensitive switches versus flat panel "virtual switches", and the presence or absence of auditory feedback from switch contact. Performance with stimuli using physical switches was 1.2 s faster than virtual switches (2.0 s vs. 3.2 s); auditory feedback provided a 0.54 s performance advantage (2.33 s vs. 2.87 s). There was no interaction between these variables. Preference data were highly correlated with performance.

Begault, Durand R.↗

Simulation System for Training in Laparoscopic Surgery

A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

Basdogan, Cagatay↗

Synthesis and Characterization of Uranium Complexes Supported by Substituted Aryldimethylsilylanilide Ligands

Here, we report the synthesis and characterization of substituted aryldimethylsilyldiisopropylanilide ligands and their respective bisamido complexes of U(III), (3,5-R 2 -PhMe 2 SiNDipp) 2 UI(dioxane) x (1, R = H, x= 0; 2, R = Me, x = 0; 3, R = t Bu, x = 1). We found that the steric bulk of the 3,5-R 2 -Ph ring affects the hapticity of the U–arene interaction. In the solid-state, 1 is a U–(η 6 -arene) complex, while 2 is a bis(U–(η 1 -arene)) complex. Theoretically calculated bond orders at PBE0 and PBE0-D3 levels of theory support these hapticity assignments. The 3,5- t Bu 2 -Ph rings of 3 are too bulky to interact with U and solid-state metrical parameters initially suggested a U–(η 1 -arene) interaction with one of the Dipp rings. However, bond order calculations show that this interaction is even weaker than in the previously reported ((PhMe 2 Si) 2 N) 3 U complex, leading to the conclusion that 3 is best described as a U–(η o -arene) complex. Molecular orbital analyses in conjunction with electron localization methods reveal that the U–(η 6 -arene) bonding in 1 is primarily electrostatic in nature. Some charge transfer takes place from the arene π orbitals to the U 6d/5f hybrid orbitals in addition to subtle δ-back-bonding. In 2 and 3, both π and δ interactions are substantially weaker, in agreement with the differences in the U–arene coordination modes. Surprisingly, attempts to generate less sterically bulky (3,5-R 2 -PhMe 2 SiNPh) 2 UI complexes results in disproportionation to homoleptic tetraamido (3,5-R 2 -PhMe 2 SiNPh) 4 U(IV) (4, R = H; 5, R = Me) complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗