Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat exchanger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Evaluation of a Passive Heat Exchanger Based Cooling System for Fuel Cell Applications

Fuel cell cooling is conventionally performed with an actively controlled, dedicated coolant loop that exchanges heat with a separate external cooling loop. To simplify this system the concept of directly cooling a fuel cell utilizing a coolant loop with a regenerative heat exchanger to preheat the coolant entering the fuel cell with the coolant exiting the fuel cell was analyzed. The preheating is necessary to minimize the temperature difference across the fuel cell stack. This type of coolant system would minimize the controls needed on the coolant loop and provide a mostly passive means of cooling the fuel cell. The results indicate that an operating temperature of near or greater than 70 C is achievable with a heat exchanger effectiveness of around 90 percent. Of the heat exchanger types evaluated with the same type of fluid on the hot and cold side, a counter flow type heat exchanger would be required which has the possibility of achieving the required effectiveness. The number of heat transfer units required by the heat exchanger would be around 9 or greater. Although the analysis indicates the concept is feasible, the heat exchanger design would need to be developed and optimized for a specific fuel cell operation in order to achieve the high effectiveness value required.

Colozza, Anthony J.↗

Plate heat exchanger for heating or cooling bulk solids

A heat exchanger includes an inlet for receiving bulk solids, a plurality of heat transfer plate assemblies, a plurality of spacers disposed between adjacent heat transfer plate assemblies, and supports for supporting the heat transfer plate assemblies. The heat transfer plate assemblies include a first plate having a first pair of holes extending therethrough, the first plate having channels extending along a surface thereof, for the flow of fluid through the channels, and a second plate bonded to the first plate to enclose the channels, the second plate including a second pair of holes generally aligned with the first pair of holes to form through holes to facilitate flow of the fluid through the through holes and the channels.

Byman, Ashley D.↗

Fluid insulation to prevent ice formation in heat exchangers

Heat transfer surfaces were insulated to maintain air side surface temperature above freezing. Double wall tubes, with annular space between tubes, were filled with static liquid hydrogen. Low thermal conductivity of this hydrogen provided thermal resistance.

Coffinberry, G. A.↗

Modeling of Supercritical CO2 Shell-and-Tube Heat Exchangers Under Extreme Conditions: Part II: Heat Exchanger Model

Abstract Heat exchangers play a critical role in supercritical CO2 Brayton cycles by providing necessary waste heat recovery. Supercritical CO2 thermal cycles potentially achieve higher energy density and thermal efficiency operating at elevated temperatures and pressures. Accurate and computationally efficient estimation of heat exchanger performance metrics at these conditions is important for the design and optimization of sCO2 systems and thermal cycles. In this paper (Part II), a computationally efficient and accurate numerical model is developed to predict the performance of shell-and-tube heat exchangers (STHXs). Highly accurate correlations reported in Part I of this study are utilized to improve the accuracy of performance predictions, and the concept of volume averaging is used to abstract the geometry and reduce computation time. The numerical model is validated by comparison with computational fluid dynamics (CFD) simulations and provides high accuracy and significantly lower computation time compared to existing numerical models. A preliminary optimization study is conducted and the advantage of using supercritical CO2 as a working fluid for energy systems is demonstrated.

Engineering↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods of forming components of heat exchangers and methods of forming heat exchangers

A method of forming at least a component of a heat exchanger comprises introducing a feed material comprising a first portion including a matrix material and a second portion including a sacrificial material on a surface of a substrate, exposing at least the first portion to energy to form bonds between particles of the matrix material and form a first thickness of a structure, introducing additional feed material comprising the first portion over the first thickness of the structure, exposing the additional feed material to energy to form a second thickness of the structure, and removing the sacrificial material from the structure to form at least one channel in the structure. Related heat exchangers and components, and related methods are disclosed.

van Rooyen, Isabella J.↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

A Computational Fluid Dynamic Study on Polymer Heat Exchangers

Polymer heat exchangers have been developed for the applications involving weight restrictions or chemical compatibility and fouling issues owing to the low density, anticorrosive properties, and low thermal expansion of polymers. Recently development of additive manufacturing also brings new opportunities to make polymer heat exchangers with desired design that was hard to realize before. However, due to the lower thermal conductivity polymer composite, the overall heat transfer performance is still a challenge in the polymer heat exchanger technology. In present work, a computational fluid dynamic (CFD) model has been developed to study the overall heat transfer performance of additively manufactured polymer heat exchangers. The CFD results offer an insight of fluid flow and temperature distribution in the polymer heat exchangers. This study provides a guidance not only on the polymer material selection but also on the design of polymer heat exchangers. The conclusions will be helpful to design a polymer heat exchanger whose overall heat transfer performance is comparable to a metal heat exchanger.

Zhang, Mingkan↗

Modular Heat Exchanger With Integral Heat Pipe

Modular heat exchanger with integral heat pipe transports heat from source to Stirling engine. Alternative to heat exchangers depending on integrities of thousands of brazed joints, contains only 40 brazed tubes.

Schreiber, Jeffrey G.↗

Experimental Investigation of Gas-Side Performance of a Compact Finned-Tube Heat Exchanger

Heat-transfer and pressure-drop data were obtained experimentally for the gas side of a liquid-metal to air, compact finned-tube heat exchanger. The heat exchanger was fabricated from 0.185-inch Inconel tubing in an inline array. The fins were made of 310 stainless-steel- clad copper with a total thickness of 0.010 inch, and the fin pitch was 15.3 fins per inch. The liquid used as the heating medium was sodium. The heat-exchanger inlet gas temperature was varied from 5100 to 1260 R by burning JP fuel for airflow rates of 0.4 to 10.5 pounds per second corresponding to an approximate Reynolds number range of 300 to 9000. The sodium inlet temperature was held at 1400 R with the exception of a few runs taken at 1700 and 1960 R. The maximum ratio of surface temperature to air bulk temperature was 1.45. Friction-factor data with heat transfer were best represented by a single line when the density and viscosity of Reynolds number were evaluated at the average film temperature. At the lower Reynolds numbers reported, the friction data with heat transfer plotted slightly above the friction data without heat transfer. The density of the friction factor was calculated at the average bulk temperature. Heat-transfer results of this investigation were correlated by evaluating the physical properties of air (specific heat, viscosity, and thermal conductivity) at the film temperature.

Gedeon, Louis↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal hydraulic characteristics of liquid sodium and supercritical CO 2 in a diffusion bonded heat exchanger

Compact heat exchangers are being examined for use in advanced, high-temperature nuclear or concentrated solar power plants to improve thermal efficiencies and reduce capital costs. At the time of this work, no experimental investigation of liquid sodium in the popular diffusion-bonded heat exchanger design had been performed. Herein this paper describes the thermal-hydraulic and overall operations performance observed during testing of a 316/L stainless steel “zig-zag” microchannel heat exchanger operating between a (0.5 kg/s) sodium loop and a (0.3 kg/s) recuperated supercritical CO 2 system with outlet conditions up to 550 °C at 16 MPa. Observed pressure drop is presented in the form of an effective friction factor correlation which aligns closely with recent experimental data. The thermal performance of this heat exchanger, measured by its overall conductance under various flow conditions, was decomposed to examine the independent convection behaviors of both the CO 2 and sodium streams. These results are presented in the form of Nusselt correlations fitted to the experimental data. The sodium heat transfer correlation aligns closely with the widely accepted Lubarsky-Kaufman correlation, while the CO 2 heat transfer correlation lies between previous correlations developed by computational and experimental methods. This was the first long-duration use of sodium in a microchannels (~1.8 mm hydraulic diameter) heat exchanger. The use of an oxide control system enabled trouble-free operation of the heat exchanger for over 150 h of high-temperature operation. This first-of-a-kind demonstration using liquid sodium and supercritical carbon dioxide shows great promise for further application of this technology in advanced nuclear or solar power plants.

42 ENGINEERING↗

MHTLS Cross-flow Heat Exchanger Temperature Performance Data

The presentation and supporting information provide data on the performance of an engineering-scale cross-flow heat exchanger used in hydrothermal liquefaction (HTL). Temperature profiles are provide for the process of waste water treatment sludges and a food waste. The data can be used to model larger-scale heat exchangers used in HTL.

Bioenergy Technologies Tags Heat Exchanger HTL MHT↗

Hollow lattice thermal energy storage heat exchanger

Example heat exchangers and methods of use are described herein. An example heat exchanger includes a lattice structure including a plurality of conduits defining a plurality of interstitial voids between the plurality of conduits. Each of the plurality of conduits includes an inlet and an outlet, and the plurality of conduits are arranged such that, between the inlet and the outlet, each of the conduits intersects at least one other conduit to enable flow between the intersecting conduits. The example heat exchanger also includes a first manifold formed unitarily with the lattice structure, the first manifold comprising a first plurality of openings in fluid communication with each inlet of the plurality of conduits. The example heat exchanger further includes a phase change material (PCM) disposed within and substantially filling the plurality of interstitial voids.

Stoia, Michael F.↗

Design of Modular Test Facility for Particle/sCO2 Heat Exchanger Evaluation

Heliogen has designed a 1.3 MW particle and supercritical carbon dioxide (sCO2) test loop to retire technical and manufacturing risks. The data from this facility will be used to validate near commercial-scale particle heat exchanger modules. The heat exchanger is scaled to capture all features of the full-scale modules. Testing will be conducted with CARBOBEAD HSP 16/30, a larger particle size than other recent testing. The system was designed to ASME codes with the constraint that sCO2 piping and other major components are stainless steels.

14 SOLAR ENERGY↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗