Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat of vaporization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Airborne Measurements of Scale‐Dependent Latent Heat Flux Impacted by Water Vapor and Vertical Velocity Over Heterogeneous Land Surfaces During the CHEESEHEAD19 Campaign

Abstract The water vapor transport associated with latent heat flux (LE) in the planetary boundary layer (PBL) is critical for the atmospheric hydrological cycle, radiation balance, and cloud formation. The spatiotemporal variability of LE and water vapor mixing ratio ( r v ) are poorly understood due to the scale‐dependent and nonlinear atmospheric transport responses to land surface heterogeneity. Here, airborne in situ measurements with the wavelet technique are utilized to investigate scale‐dependent relationships among LE, vertical velocity ( w ) variance (), and r v variance () over a heterogeneous surface during the Chequamegon Heterogeneous Ecosystem Energy‐balance Study Enabled by a High‐density Extensive Array of Detectors 2019 (CHEESEHEAD19) field campaign. Our findings reveal distinct scale distributions of LE, , and at 100 m height, with a majority scale range of 120 m–4 km in LE, 32 m–2 km in , and 200 m–8 km in . The scales are classified into three scale ranges, the turbulent scale (8–200 m), large‐eddy scale (200 m–2 km), and mesoscale (2–8 km) to evaluate scale‐resolved LE contributed by and . The large‐eddy scale in PBL contributes over 70% of the monthly mean total LE with equal parts (50%) of contributions from and . The monthly temporal variations mainly come from the first two major contributing classified scales in LE, , and . These results confirm the dominant role of the large‐eddy scale in the PBL in the vertical moisture transport from the surface to the PBL, while the mesoscale is shown to contribute an additional ∼20%. This analysis complements published scale‐dependent LE variations, which lack detailed scale‐dependent vertical velocity and moisture information.

54 ENVIRONMENTAL SCIENCES↗

ASSESSING FUEL PROPERTY EFFECTS ON CAVITATION AND EROSION PROPENSITY USING A COMPUTATIONAL FUEL SCREENING TOOL

To advance compression ignition combustion strategies, researchers have evaluated fuel property effects and their impact on achieving higher efficiencies and lower emissions levels relative to current capabilities. Within the Department of Energy's Co-Optima initiative, there has been a recent focus on understanding the influence of fuel properties on fuel injection performance. To help identify candidate fuels that can meet desired injector performance metrics, a computational fuel screening tool is under development that can link fuel properties with the tendency of a given fuel to cavitate and lead to cavitation-induced erosion. In the initial development of this tool, five liquid fuel properties were selected to represent candidate fuels, namely density, viscosity, vapor pressure, surface tension, and heat of vaporization. A design of experiments methodology was employed to generate a set of pseudo fuel cases, which can represent the main effects and interactions among the fuel properties and be related to cavitation erosion predictions. Large eddy simulations were performed using a mixture modeling approach to predict the cavitation and erosion propensity of these pseudo-fuels in terms of the mean fuel vapor mole fraction and stored impact energy from repeated cloud collapse events. The low order regression models generated from this study revealed the importance of liquid fuel density on cavitation formation, whereas liquid viscosity was found to have a strong negative correlation with erosion severity. The surrogate models were then used in the fuel screening tool to rank the cavitation and erosion tendency of four candidate single-component fuels: methyl decanoate, isooctane, ethanol and n-dodecane. While the fuel screening tool was not able to quantitatively predict the cavitation and erosion response metrics, the tool was able to accurately rank the relative cavitation and erosion propensity of the four fuels. Overall, ethanol and iso-octane were observed to produce the highest levels of cavitation and erosion, respectively.

cavitation-induced erosion↗

Validated model of a thermoelectric heat pump clothes dryer using secondary pumped loops

The energy associated with clothes drying makes up 4% of the total residential electrical energy consumption in the US. The cost is high since most clothes dryers use electric resistance heating which is inexpensive but also energy inefficient. State-of-the-art vapor-compression heat pump clothes dryers offer significant energy savings but have limited market penetration in the US. Here, a new configuration of clothes dryer was studied that utilizes a solid-state thermoelectric heat pump with pumped secondary water loops and conventional fin-and-tube water-to-air heat exchangers. Experimental results are presented for the thermoelectric dryer prototype with a combined energy factor of 6.89 lb BDW /kWh (specific moisture extraction rate of 1.71 kg w /kWh) and a dry time of 84 min for a standard load size of 8.45 lb (3.83 kg) with 57.5% starting moisture content. This is a 85% energy efficiency improvement over baseline electric resistance dryers. The efficiency and drying time results achieved are similar to vapor compression heat pump dryers. Compared to previous air-based thermoelectric clothes dryers, the energy efficiency has been increased by 6%, but drying time has been reduced by as much as 47% using secondary pumped loops and separate heat exchangers, which represents a significant advancement in the technology. In addition to the experimental prototype, a model was also developed to study the performance. The model was validated against experimental prototype data and used to identify the range of performance (dry time and efficiency) that could be expected of the design.

42 ENGINEERING↗

Evidence of vapor shielding effect on heat flux loaded on flowing liquid lithium limiter in EAST

For this study, a lithium (Li) vapour layer was formed around a flowing liquid Li limiter to shield against the plasma incident power and reduce limiter heat flux in the EAST tokamak. The results revealed that after a plasma operation of a few seconds, the layer became clear, which indicated a strong Li emission with a decrease in the limiter surface temperature. This emission resulted in a dense vapour around the limiter, and Li ions moved along the magnetic field to form a green shielding layer on the limiter. The plasma heat flux loaded on the limiter, measured by the probe installed on the limiter, was approximately 52% lower than that detected by a fast-reciprocating probe at the same radial position without the limiter in EAST. Additionally, approximately 42% of the parallel heat flux was dissipated directly with the enhanced Li radiation in the discharge with the liquid metal infused trenches (LIMIT) limiter. This observation revealed that the Li vapour layer exhibited an excellent shielding effect to liquid Li on plasma heat flux, which is a possible benefit of liquid-plasma-facing components in future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free-spray characteristics and spray-wall interactions of methanol on a gasoline direct injector under flash-boiling and non-flash-boiling conditions

Methanol is considered a promising alternative fuel for internal combustion engines (ICEs) due to its high-octane number, fast laminar flame speed, and elevated latent heat of vaporization, all of which support higher compression ratios and improved thermal efficiency. However, its substantial latent heat of vaporization also poses cold-start challenges, such as misfire and fuel film deposition. This study aims to investigate methanol spray morphology and spray-wall interaction using the Spray M injector from the Engine Combustion Network within a constant-pressure flow vessel. A recently developed unified numerical framework capable of modeling both flash and non-flash boiling sprays is validated against experimental liquid volume fraction data acquired via 3-D computed tomography. Here, the results reveal that flash boiling significantly alters the spray morphology, leading to smaller droplets and spray collapse due to enhanced air-entrainment-induced turbulence. Quantitative agreement between experiments and simulations confirms this behavior. Coupled 0-D equilibrium and 3-D computational fluid dynamics analyses show that flash boiling accelerates evaporation and reduces fuel residence time, while non-flash conditions maintain a persistent liquid core more susceptible to wall wetting. Wall temperature diagnostics reveal that spray collapse alters heat transfer patterns by shifting cooling effects. Mixture fraction analysis indicates that evaporation is primarily governed by shear-layer turbulence, though deviations from adiabatic equilibrium mixing emerge under low-turbulence conditions. Finally, increasing fuel, ambient, and wall temperatures reduces wall wetting and film thickness, mitigating cold-start risks. These findings enhance the understanding of methanol sprays’ behavior and support its adoption as a viable, alternative fuel for ICEs.

Engine Combustion Network↗

Sensitivity of magnetohydrodynamic simulations of Joule-heated conductors to the vaporization curve in equations of state

Magnetohydrodynamic (MHD) simulations of electrically exploded aluminum and copper rods demonstrate a technique to validate equations of state (EOS) for rapidly Joule-heated conductors. The balance of internal and magnetic forces at the conductor-insulator interface drives the metal there along the vaporization phase boundary. Variations between critical points and vaporization curves in existing models predict differing densities and temperatures in MHD simulations for these models. Here, the inclusion of Maxwell constructs in the liquid-vapor biphase region of the EOS caused the rod surface to vaporize earlier in time than unmodified tables with van der Waals loops. Velocimetry of recent experiments is used to validate the location of the vaporization curve in existing EOS models and differentiate between the vapor dome treatments. Dielectric coatings applied to the metal surface restricted the conductor’s expansion and diverted the metal into the warm dense matter regime.

36 MATERIALS SCIENCE↗

Rubidium and potassium isotopic variations in chondrites and Mars: Accretion signatures and planetary overprints

As moderately volatile elements, isotopes of Rb and K can trace volatilization processes in planetary bodies. Rubidium isotopic data are however very scarce, especially for non-carbonaceous meteorites. Here, in this study, we report combined Rb and K isotopic data (δ 87/85 Rb and δ 41/39 Κ) for 7 ordinary, 6 enstatite, and 4 Martian meteorite falls to understand the causes for the variations in volatile abundances and isotopic compositions. Bulk Rb and K isotopic compositions of planetary bodies are estimated to be (Table 1): Mars +0.10 ± 0.03 ‰ for Rb and -0.26 ± 0.05 ‰ for K, bulk OCs $-0.12^{+0.15}_{-0.24}$ ‰ for Rb and $-0.72^{+0.28}_{-0.41}$ ‰ for K, bulk ECs $-0.02^{+0.29}_{-0.26}$ ‰ for Rb and $-0.33^{+0.37}_{-0.23}$ ‰ for K. The bulk K isotopic compositions of subgroup OCs are estimated to be $-0.72^{+0.26}_{-0.55}$ ‰ for H chondrites, $-0.71^{+0.23}_{-0.39}$ ‰ for L chondrites, and $-0.77^{+0.63}_{-0.30}$ ‰ for LL chondrites. A broad correlation between the Rb and K isotopic compositions of planetary bodies is observed. The correlation follows a slope that is consistent with kinetic evaporation and condensation processes, suggesting volatility-controlled mass-dependent isotope fractionation (as opposed to nucleosynthetic anomalies). Individual ordinary and enstatite chondrites show large Rb and K isotopic variations (-1.02 to +0.29 ‰ for Rb and -0.91 to -0.15 ‰ for K). Samples of lower metamorphic grades display correlated elemental and isotopic fractionations between Rb and K, while samples of higher metamorphic grades show great scatter, suggesting that chondrite parent-body processes have decoupled the two elements and their isotopes at the sample scale. Several processes could have contributed to the observed isotopic variations of Rb and K, including (i) chondrule “nugget effect”, (ii) volatilization during parent-body thermal metamorphism (heat-induced vaporization and gas transport within parent bodies), (iii) thermal diffusion during parent-body metamorphism, and (iv) impact/shock heating. Quantitative modeling of the first two processes suggests that neither of them could produce isotopic variations large enough to explain the observed isotopic variations. Volatilization during parent-body thermal metamorphism [the scenario (ii)], which has been commonly invoked to explain the isotopic variations of volatile elements, is gas transport-limited and its effect on isotopic fractionations of moderately volatile elements should be negligible. Modeling of diffusion processes suggests that (iii) could produce K isotopic variation comparable to the observed variation. The large isotopic variations in non-carbonaceous meteorites are thus most likely due to diffusive redistribution of K and Rb during metamorphism and/or shock-induced heating and vaporization.

58 GEOSCIENCES↗

Review of the potential and challenges of MOF-based adsorption heat pumps for sustainable cooling and heating in the buildings

Heat pumps are regarded as the most suitable means to meet the future demand of heating and cooling in the building, as they require small input of electrical energy and output high thermal energy. Vapor compression heat pump (VCHP) and transcritical-CO 2 heat pump are the two major heat pump technologies currently dominating the market. However, VCHP system suffers from its fugitive emission of hydrofluorocarbon (HFC) refrigerants, and transcritical-CO 2 system requires high operating pressure (typically 9–13 MPa). For low-to-medium temperature heating and cooling applications thermally driven adsorption heat pump (AHP) provides a better alternative to VCHP and transcritical-CO 2 system as AHP uses natural refrigerants and operates at a much lower pressure. But currently available AHP technology has the limitation of low coefficient of performance (COP). Advances in synthesizing metal-organic frameworks (MOF) with high gas adsorption capacity have created an opportunity to address the problem of low COP of current AHP technology. Here, this article reviews the progress made in the past decade in utilizing MOF and conventional adsorbents with different working fluids in AHP technology and compares their performance. The article also summarizes the key challenges for the MOF-based AHP technology and provides the authors’ perspective to address these challenges.

30 DIRECT ENERGY CONVERSION↗

Analytical solution and parameter estimation for heat of wetting and vapor adsorption during spontaneous imbibition in tuff

An analytical expression is derived for the thermal response observed during spontaneous imbibition of water into a dry core of zeolitic tuff. Sample tortuosity, thermal conductivity, and thermal source strength are estimated from fitting an analytical solution to temperature observations during a single laboratory test. Here, the closed-form analytical solution is derived using Green's functions for heat conduction in the limit of “slow” water movement; that is, when advection of thermal energy with the wetting front is negligible. The solution has four free fitting parameters and is efficient for parameter estimation. Laboratory imbibition data used to constrain the model include a time series of the mass of water imbibed, visual location of the wetting front through time, and temperature time series at six locations. The thermal front reached the end of the core hours before the visible wetting front. Thus, the predominant form of heating during imbibition in this zeolitic tuff is due to vapor adsorption in dry zeolitic rock ahead of the wetting front. The separation of the wetting front and thermal front in this zeolitic tuff is significant, compared to wetting front behavior of most materials reported in the literature. This work is the first interpretation of a thermal imbibition response to estimate transport (tortuosity) and thermal properties (including thermal conductivity) from a single laboratory test.

36 MATERIALS SCIENCE↗

Relaxing the constant molar overflow assumption in distillation optimization

Abstract The constant molar overflow (CMO) framework, while useful for shortcut distillation models, assumes that all components have the same latent heats of vaporization. A simple transformation, from molar flows to latent‐heat flows, allows shortcut models to retain the mathematical simplicity of the CMO framework while accounting for different latent heats, resulting in the constant heat transport (CHT) framework for adiabatic distillation columns. Although several past works have already proposed this transformation in the literature, it has not been well utilized in recent times. In this article, we show the utility of this transformation in upgrading various applications such as identifying energy‐efficient multicomponent distillation configurations based on heat duty rather than surrogate vapor flow. The method transforms the diagram to a diagram. Furthermore, we derive new and insightful analytical results in distillation, such as cumulative latent‐heat stage fractions having monotonic profiles within a distillation column under the CHT framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Predicting critical heat flux using localized sensing at invisible vapor-liquid interfaces

Predicting critical heat flux (CHF) in two-phase electronics cooling systems remains a significant challenge due to the sudden onset of boiling crisis and the difficulty in directly visualizing vapor-liquid interfaces. Existing sensing methods rely on lagging temperature measurements, optically accessible systems, or spatially averaged signals that cannot pinpoint CHF initiation at localized high-heat-flux regions. Here, we report a planar capacitive sensing approach that enables real-time, localized detection of vapor-liquid interface dynamics for CHF prediction in boiling heat transfer. The capacitive sensor exploits the dielectric constant difference between liquid and vapor phases to capture bubble nucleation, growth, and departure dynamics with a temporal resolution down to 2 ms. The capacitive sensing reveals distinct signals across boiling regimes: from high-frequency fluctuations during strong nucleate boiling to low-frequency fluctuations with increased amplitudes when approaching CHF. The multi-sensor array experiments demonstrate real-time localized sensing, where each sensor responds exclusively to boiling in its immediate vicinity without crosstalk from neighboring regions. This non-intrusive sensing approach provides predictive rather than lagging sensing signals of CHF occurrence, offering predictive diagnosis of two-phase liquid cooling for the thermal management of high-power-density electronics.

CHF↗

Experimental study of flash boiling spray with isooctane, hexane, ethanol and their binary mixtures

The main goal of this study is to understand the effect of fuel properties on flash boiling sprays using multi-hole injectors. Macroscopic characteristics were investigated using Diffused Backlight Imaging (DBI) and quantified with liquid penetration length and spray angles. Phase Doppler Anemometry (PDA) was applied to measure the droplet size and velocity. Behaviors of spray with three single-component fuels (isooctane, hexane, ethanol) under different ambient pressures (100 kPa, 80 kPa, 50 kPa, 22 kPa) as well as their binary mixtures under different blend ratios (10%, 30%, 85%) were reported and analyzed. The results showed that adding ethanol or hexane to isooctane could both promote flash boiling by increasing the overall vapor pressure thus superheated degree. Under mixing ratios of 10% and 30%, sprays with ethanol blends showed more severe flash boiling comparing with sprays with hexane blends. Shorter liquid penetration and better liquid dispersion have been observed. Comparing with isooctane spray, the droplet size continuously decreased with increasing hexane content due to enhanced breakup and faster vaporization. Sprays with ethanol mixtures showed a different trend. Noticeable droplet size reduction has been observed for spray with 10% ethanol content. However, droplet size did not further decrease with higher blend ratios regardless of higher flash boiling intensity. Such observations indicate severe vaporization inhibition caused by the high latent heat of vaporization of ethanol. For sprays with all test fuels, collapsing occurred when the pressure ratio of ambient pressure to saturation pressure (Rp) dropped below 0.3.

03 NATURAL GAS↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Process-dependent anisotropic thermal conductivity of laser powder bed fusion AlSi10Mg: impact of microstructure and aluminum-silicon interfaces

Purpose AlSi10Mg alloy is commonly used in laser powder bed fusion due to its printability, relatively high thermal conductivity, low density and good mechanical properties. However, the thermal conductivity of as-built materials as a function of processing (energy density, laser power, laser scanning speed, support structure) and build orientation, are not well explored in the literature. This study aims to elucidate the relationship between processing, microstructure, and thermal conductivity. Design/methodology/approach The thermal conductivity of laser powder bed fusion (L-PBF) AlSi10Mg samples are investigated by the flash diffusivity and frequency domain thermoreflectance (FDTR) techniques. Thermal conductivities are linked to the microstructure of L-PBF AlSi10Mg, which changes with processing conditions. The through-plane exceeded the in-plane thermal conductivity for all energy densities. A co-located thermal conductivity map by frequency domain thermoreflectance (FDTR) and crystallographic grain orientation map by electron backscattered diffraction (EBSD) was used to investigate the effect of microstructure on thermal conductivity. Findings The highest through-plane thermal conductivity (136 ± 2 W/m-K) was achieved at 59 J/mm 3 and exceeded the values reported previously. The in-plane thermal conductivity peaked at 117 ± 2 W/m-K at 50 J/mm 3 . The trend of thermal conductivity reducing with energy density at similar porosity was primarily due to the reduced grain size producing more Al-Si interfaces that pose thermal resistance. At these interfaces, thermal energy must convert from electrons in the aluminum to phonons in the silicon. The co-located thermal conductivity and crystallographic grain orientation maps confirmed that larger colonies of columnar grains have higher thermal conductivity compared to smaller columnar grains. Practical implications The thermal properties of AlSi10Mg are crucial to heat transfer applications including additively manufactured heatsinks, cold plates, vapor chambers, heat pipes, enclosures and heat exchangers. Additionally, thermal-based nondestructive testing methods require these properties for applications such as defect detection and simulation of L-PBF processes. Industrial standards for L-PBF processes and components can use the data for thermal applications. Originality/value To the best of the authors’ knowledge, this paper is the first to make coupled thermal conductivity maps that were matched to microstructure for L-PBF AlSi10Mg aluminum alloy. This was achieved by a unique in-house thermal conductivity mapping setup and relating the data to local SEM EBSD maps. This provides the first conclusive proof that larger grain sizes can achieve higher thermal conductivity for this processing method and material system. This study also shows that control of the solidification can result in higher thermal conductivity. It was also the first to find that the build substrate (with or without support) has a large effect on thermal conductivity.

Engineering↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗