Effects of heat loads on flow and heat transfer in the entrance region of a cooling duct with a staggered array of pin fins
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Experimental results show conclusively that the presence of a small quantity of a noncondensable gas (NCG) mixed with the working fluid has a considerable effect on the condensation process in a rotating heat pipe. The temperature distribution in the condenser shows the blanketing effect of the NCG and the ratio of the molecular weight of the working fluid to that of the NCG has a very definite effect on the shape of this distribution. Some of the effects are quite similar to the well-established data on stationary heat pipes.
NASA has developed a subscale rotating detonation rocket engine platform, enabling rapid parameterization of components and their associated performances. A major performance metric of interest for RDREs is the total heat absorbed at a given operating condition and wave mode operation. To investigate this, several sets of hardware were produced to have variation of the contraction ratio, injector geometry, and length. A wide range of total mass flow rates and mixture ratios were also explored using gaseous methane/oxygen. All hardware was produced using laser powder bed fusion GRCop-42, GRX-810, or C-103 alloys depending on the component cooling requirements. Outer and inner body hardware were made from GRCop-42 where heat fluxes were expected to be high and were water cooled through integrated coolant channels. Nozzles were made from C-103 which are radiatively cooled. Finally, the injectors were produced using GRCop-42 or GRX-810 as passive cooling via propellant injection has previously found to be sufficient given the small gap width of exposed injection surface. Total heat load and bulk heat flux measurements to the hot walls are reported. Trends in heat load and heat flux are shown with relation to parameters such as chamber pressure, area ratio, and wave mode. Heat loads between the inner and outer bodies and the chamber and shroud section are compared.
NASA has developed a subscale rotating detonation rocket engine platform, enabling rapid parameterization of components and their associated performances. A major performance metric of interest for RDREs is the total heat absorbed at a given operating condition and wave mode operation. To investigate this, several sets of hardware were produced to have variation of the contraction ratio, injector geometry, and length. A wide range of total mass flow rates and mixture ratios were also explored using gaseous methane/oxygen. All hardware was produced using laser powder bed fusion GRCop-42, GRX-810, or C-103 alloys depending on the component cooling requirements. Outer and inner body hardware were made from GRCop-42 where heat fluxes were expected to be high and were water cooled through integrated coolant channels. Nozzles were made from C-103 which are radiatively cooled. Finally, the injectors were produced using GRCop-42 or GRX-810 as passive cooling via propellant injection has previously found to be sufficient given the small gap width of exposed injection surface. Total heat load and bulk heat flux measurements to the hot walls are reported. Trends in heat load and heat flux are shown with relation to parameters such as chamber pressure, area ratio, and wave mode. Heat loads between the inner and outer bodies and the chamber and shroud section are compared.
This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.
Abstract High power tokamaks operate with divertor heat loads capable of destroying the plasma facing components (PFCs). High fidelity heat load predictions are necessary to ascertain the PFC state for design and during operation. Typical heat flux calculations are 2D, time invariant, and assume that power flows directly along the magnetic field lines (the optical approximation). These assumptions neglect the complex 3D geometries employed to protect the PFCs, the time varying nature of the plasma and PFC thermal state, and the helical trajectories of ions with finite Larmor radii (the gyro-orbit approximation). An integrated software framework, the heat flux engineering analysis toolkit (HEAT), was developed to generate time varying optical heat loads applied to real engineering computer aided design (CAD) (Looby et al 2022 Fusion Sci. Technol. 78 10–27). Recently, an ion-gyro orbit module has been added to HEAT. This module calculates the helical trajectories of ions as they gyrate about the magnetic field lines using kinetic theory macro-particles to accelerate the calculation. First, the new gyro-orbit module will be presented. Next, a comparison to existing research is performed. Finally, an analysis of the gyro-orbit heat loads for NSTX-U is presented for diverted discharges using the engineering CAD models utilized for PFC fabrication. Including these gyro-orbit effects can enhance the PFC performance by ‘smearing’ out the magnetic shadows associated with the castellated fish-scaled geometry. Simultaneously, the helical trajectories can degrade performance when they load narrow regions on edges and corners with high heat fluxes. Analysis of the trade-offs between these competing effects is included, and regions for further investigation are identified.
Heat loads on the tungsten divertor targets in the ITER and the tokamak power reactors reach ~10MW m{sup −2} in the steady state of DT discharges, increasing to ~0.6–3.5 GW m{sup −2} under disruptions and ELMs. The results of high heat flux tests (HHFTs) of tungsten under such transient plasma heat loads are reviewed in the paper. The main attention is paid to description of the surface microstructure, recrystallization, and the morphology of the cracks on the target. Effects of melting, cracking of tungsten, drop erosion of the surface, and formation of corrugated and porous layers are observed. Production of submicron-sized tungsten dust and the effects of the inhomogeneous surface of tungsten on the plasma–wall interaction are discussed. In conclusion, the necessity of further HHFTs and investigations of the durability of tungsten under high pulsed plasma loads on the ITER divertor plates, including disruptions and ELMs, is stressed.
The heat loading on plasma facing components (PFCs) provides a critical limitation for design and operation of the first wall, divertor, and other special components. Power plants will have high power entering the scrape-off layer and transporting to the first wall and divertor. Although the design for steady heat loads is understood, the approach for transient and offnormal loading is not. The characterization of heat loads developed for ITER1 can be applied to power plants to better develop the operating space of viable solutions and point to research focus areas.
Superconducting magnets used in tokamaks undergo periodic heat load caused by cycling plasma operations inducing AC losses, neutrons fluxes and eddy currents in magnet structures. In the cryogenic system of JT60-SA tokamak, the Auxiliary Cold Box (ACB) distributes helium from the refrigerator to the cryogenic users and in particular to the superconducting magnets. ACB comprises a saturated helium bath with immersed heat exchangers, extracting heat from independent cooling loops. The supercritical helium flow in each cooling loop is driven by a cold circulator. In order to safely operate the refrigerator during plasma pulses, the interface between the ACB and the refrigerator shall be as stable as possible, with well-balanced bath inlet and outlet mass flows during cycling operation. The solution presented in this paper relies on a combination of regulations to smooth pulsed heat loads and to keep a constant refrigeration power during all the cycle. Two smoothing strategies are presented, both regulating the outlet mass flow of the bath: the first one using the bath as a thermal buffer and the second one storing energy in the loop by varying the cold circulator speed. The bath outlet mass flow is also controlled by an immersed resistive heater which enables a constant evaporation rate in the bath when power coming from the loops is decreasing. The refrigeration power is controlled so that the compensating power remains within an acceptable margin. Experimental validation is achieved using the HELIOS facility. This facility running at CEA Grenoble since 2010 is a scaled down model of the ACB bath and Central Solenoid magnet cooling loop of the JT60-SA tokamak. Test results show performances and robustness of the regulations.
EAST is the first full superconducting fusion device. The plasma is confined by the magnetic fields generated from a large set of superconducting magnets which are made of cable in-conduit conductor (CICC). In operation, these magnets suffer heat loads from thermal and nuclear radiation from the surrounding components and plasma as well as the eddy currents and the AC losses generated within the magnets, together with the heat conduction through supports and the resistive heat generated at the current lead transiting to room temperature. The cryogenic system of our EAST consists of a 2kW/4K helium refrigerator and a distribution system for the cooling of poloidal field (PF) and toroidal field (TF) coils, structures, thermal shields, buslines and current leads. Pulsed heat load is the main difference between the cryogenic system of a full superconducting Tokamak system and other large scale cryogenic systems. The cryogenic system operates in a pulsed heat loads mode requiring the helium refrigerator to remove periodically large heat loads in time. At the same time, the cryogenic system parameters such as helium cooling superconducting magnets, helium refrigerator and helium distribution system are changing. In this paper, the variation range of the parameters of superconducting magnets and refrigerator has been analyzed in the typical plasma discharge mode. The control scheme for the pulsed loads characteristics of the cryogenic system has been proposed, the implementation of which helps to smooth the pulse loads and to improve the stability of the operation of the cryogenic system.
A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.
A method including obtaining calibration data for at least one sub-component in a heat transfer assembly, wherein the calibration data comprises at least one indication of coolant flow rate through the sub-component for a given surface temperature delta of the sub-component and a given heat load into said sub-component, determining a measured heat load into the sub-component, determining a measured surface temperature delta of the sub-component, and determining a coolant flow distribution in a first flow path comprising the sub-component from the calibration data according to the measured heat load and the measured surface temperature delta of the sub-component.
Experimental diffusion freezeout rates in a gas loaded heat pipe are presented and compared with predictions of an analysis and computer program published earlier. The experimental approach was to pivot a heat pipe on knife edges and use an analytical mass balance to measure the rate of mass migration within the pipe. Diffusion freezeout rates in a water heat pipe were measured as a function of the condenser sink temperature and the condenser-to-sink thermal conductance. Measured rates varied between 19 and 270 mg/hr and yielded 64 to 99 percent agreement with predicted values. These results indicated that the analysis and computer program for predicting the behavior of gas loaded heat pipes are useful tools for designing such systems.
Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.
Locked mode disruptions with controlled toroidal phase are produced in the DIII-D tokamak by locking to large non-axisymmetric applied magnetic perturbations with different toroidal phases. Additionally, the disruption conducted heat loads are found to go almost completely to the outer divertor region, possibly due to strong inner leg detachment, but possibly also due to plasma motion and limiting on the outer divertor leg shelf. The outer leg conducted heat loads are found to have a significant toroidal variation of order ±30%, with a dominantly n = 1 structure. The heat load phase is shifted from initial locked mode phase in a way that is approximately consistent with heat loss into the scrape-off layer being enhanced at the mode island O-point outer midplane crossing. These measurements suggest that pre-existing locked modes can affect the conducted heat load structure during the thermal quench by affecting the thermal quench MHD phase. This is consistent with previous MHD simulations which indicated that pre-disruption locked mode structures can persist and survive to some degree through the large thermal quench MHD. Finally, this work complements previous work [Shiraki2015] which showed that n = 1 structures in mitigated disruptions can create toroidal variation in the disruption radiated power.
The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.
A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. In this paper, we present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. Finally, by following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs.
The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.