Search NASA⌕ Search

SEARCH · Search NASA

Results for “helium mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Materials for Ultra‐Coherent, Mobile, Electron‐Spin Qubits

This research project has had the goal of gaining a better understanding of the physics of electrons bound to the surface of superfluid helium from both experimental and theoretical perspectives. It has particularly been aimed at two areas which had not been well studied: the relaxation and decoherence of the spin of the electrons on the helium surface and how the properties of underlying metallic layers affect the behavior of the electrons when the helium covering the metal is thin. This work is motivated in part by interest in using the spin of these electrons as a quantum bit, or qubit. Low levels of decoherence are advantageous for qubits, and moving the electrons, as one might do in a quantum processor, will be easiest if thin helium films can be employed. It had been suggested that spin decoherence should be very weak for electrons bound to superfluid He, but before this work there have been no quantitative studies of spin relaxation and decoherence. It is especially important to know how moving the electrons across the helium surface would affect their spin coherence. Calculations performed as part of this project show that the Rashba effective magnetic field, the mechanism which limits the spin coherence of mobile electrons in silicon-based devices (an actively pursued qubit technology), is exceptionally weak for electrons bound to helium. This project has identified other decoherence mechanisms which are stronger, but still weak compared to analogous silicon-based structures. Calculated spin coherence times for mobile electrons approach one day, as compared to microseconds in silicon. With coherence times of this magnitude, the spin qubit errors on helium will be completely dominated by errors in the quantum gates. In related work, the possibility of using an artificial spin-orbit interaction (a gradient magnetic field) for quantum operations on the electrons spins was considered. The calculations show that a moderate gradient field, small enough to be generated by a narrow superconducting wire, will enable high-fidelity quantum operations on electrons held in lithographically-defined quantum dots by driving them with a microwave electric field. The spin and motional coherence of the electrons is sufficient to allow high-fidelity 2-qubit quantum operations between electrons in neighboring quantum dots. As an outgrowth of experiments aiming to measure electron spin coherence it was discovered that very high densities of electrons can be stably supported on thin helium films coating ultra-smooth amorphous metallic layers. The measured densities are high enough that the electron system has almost certainly transitioned from an ordered array of electrons, known as a Wigner crystal (ordered by the electrons’ mutual repulsion), to a quantum fluid known as a Fermi liquid. This transition has been a subject of intense interest for over 40 years, since the electron Wigner crystal was first observed with electrons bound to superfluid helium, but it has never been unambiguously observed. Experiments are still underway in these new structures to definitively determine whether true quantum melting of the Wigner crystal has been demonstrated. This work has also catalyzed the development of a new approach for measuring the transport of electrons across very thin helium films, as will be needed for some of the quantum computing applications. The high electron density experiments as well as experiments with electrons bound in quantum dots have led to new techniques which may enable spin coherence measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Helium GC/IMS for the Analysis of Extraterrestrial Volatiles in Exobiology Flight Experiments

For exobiology experiments on board spacecraft or space probes, a wide range of chemical species often must be detected and identified. The limited amount of power and space available for flight instruments severely limits the number of instruments that can be flown on any given mission. It is important then, that these experiments utilize instrumentation with universal response, so that all species of interest can be analyzed. Instrumentation to fulfill the analytical requirements of exobiology experiments has been developed utilizing Gas Chromatography - Ion Mobility Spectrometry. The Gas Chromatograph (GC) combines columns developed specifically for the complex mixtures anticipated with highly sensitive Metastable Ionization Detectors (a type of Helium Ionization Detector). To satisfy the limitations placed on resources, the Ion Mobility Spectrometer (IMS) uses the same ultra high purity helium as the GC. This GC-MS provides the analytical capability to fulfill a wide range of exobiology flight experiment applications and has been included on a proposed Discovery Mission and proposals for both Lander and Orbiter of the European Space Agency's Rosetta Comet Mission. A data base of helium IMS spectra is now being built for these future applications.

Kojiro, Daniel R.↗

High Electron Mobility Transistor Structures on Sapphire Substrates Using CMOS Compatible Processing Techniques

System-on-a-chip (SOC) processes are under intense development for high-speed, high frequency transceiver circuitry. As frequencies, data rates, and circuit complexity increases, the need for substrates that enable high-speed analog operation, low-power digital circuitry, and excellent isolation between devices becomes increasingly critical. SiGe/Si modulation doped field effect transistors (MODFETs) with high carrier mobilities are currently under development to meet the active RF device needs. However, as the substrate normally used is Si, the low-to-modest substrate resistivity causes large losses in the passive elements required for a complete high frequency circuit. These losses are projected to become increasingly troublesome as device frequencies progress to the Ku-band (12 - 18 GHz) and beyond. Sapphire is an excellent substrate for high frequency SOC designs because it supports excellent both active and passive RF device performance, as well as low-power digital operations. We are developing high electron mobility SiGe/Si transistor structures on r-plane sapphire, using either in-situ grown n-MODFET structures or ion-implanted high electron mobility transistor (HEMT) structures. Advantages of the MODFET structures include high electron mobilities at all temperatures (relative to ion-implanted HEMT structures), with mobility continuously improving to cryogenic temperatures. We have measured electron mobilities over 1,200 and 13,000 sq cm/V-sec at room temperature and 0.25 K, respectively in MODFET structures. The electron carrier densities were 1.6 and 1.33 x 10(exp 12)/sq cm at room and liquid helium temperature, respectively, denoting excellent carrier confinement. Using this technique, we have observed electron mobilities as high as 900 sq cm/V-sec at room temperature at a carrier density of 1.3 x 10(exp 12)/sq cm. The temperature dependence of mobility for both the MODFET and HEMT structures provides insights into the mechanisms that allow for enhanced electron mobility as well as the processes that limit mobility, and will be presented.

Mueller, Carl↗

Properties of crystalline bismuth selenide and its use as a Hall effect magnetometer

Single crystals of n-type Bi2Se3 grown by the Bridgman technique are found to make excellent Hall effect magnetometers. Plots of Hall resistivity sub yx against magnetic field B to 10 tesla are linear to within 1 percent. Furthermore, the slope of the sub yx against B curve varies by about 1 percent in the region 1.1 to 35 K and by less than 20 percent in the region 1.1 to 300 K. Analysis of galvanomagnetic measurements indicate the samples have semimetallic densities of approximately 10 to the 25th power/cu cm, with two band conduction and near carrier compensation. Reflectivity measurements suggest a band gap of approximately 0.08 eV for the samples. The temperature dependence of mobility is also measured. A series of 50 direct immersions into liquid helium and liquid nitrogen demonstrate the reliability of Bi2Se3 magnetometers for cryogenic use.

Wollam, J. A.↗

Determination of C1-C4 alkanes by ion mobility spectrometry

Results are presented from a comparison between two ion-mobility-spectrometer (IMS) methods of sample ionisation: a conventional IMS with very dry helium and an IMS using metastable helium ionization. As one of the tests, a mixture of several hydrocarbons expected to be the components of Titan's atmosphere (made of ethane, ethylene, acetylene, propane, n-butane, isobutane, and propyne in concentrations from 20 to 200 ppm) was analyzed by both methods. Results from the dry-He IMS showed that the dry-helium approach was more adequate for the analysis of these gases than the metastable-helium IMS approach. In the metastable-He approach, in which several versions of He ionization reaction were tested, the spectra produced were not as clear as the conventional IMS spectra, due to the fact that the strong electric field introduced in the reaction region to generate metastable helium affected the gating, resolution, and collection of the ions.

Kojiro, Daniel R.↗

Design of Muon Campus Full Flow Purifier for Varying Operational Conditions and Horizontal Shipping

The Muon Campus g-2 experiment requires stable helium supply at 5 K to the superconducting magnet. After a short period of operations, the pressure drop across the magnet’s flow supply valve increases due to impurities, resulting in reduced excess capacity concurrently with drop in refrigerator expander efficiency. This requires periodic powering down of the magnet to allow for helium valve “flush” to remove accumulated contamination at the valve as well as warming up the refrigerator expander above 80 K to release contamination. A “mobile” purifier is used for this periodic process but only at 10% of total refrigerator flow such that the purification process is extended. After long duration of running, this purification procedure is required almost every two weeks to restore proper liquid helium supply to the magnet. This shows requirement for full flow purifier which can purify impurities from entire Muon Campus refrigerator system and mitigate existing impurities issue and associated experiment downtime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

Design of Stand-Alone Cryomodule based on Superconducting Quarter-Wave Resonator

Present superconducting accelerators require a central refrigeration system and piping to distribute liquid helium and nitrogen. Stand-alone cryocooler-based systems are of significant interest both to scientific and industrial customers, as they allow applications at facilities where no cryogenic equipment and expertise exists, where it is undesirable to develop additional cryogenic systems, or where a mobile system that can be transported between beamlines or facilities is required. The technical challenge of this approach is to minimize the heat losses to the liquid helium so that commercially available, self-contained cryocoolers are able to handle the thermal load. This paper presents an improved design for a stand-alone quarter-wave resonator (QWR) cryomodule a based on commercially available cryocoolers. This cryomodule has a particular application in the ATLAS intensity upgrade project where it will house a 72.75 MHz QWR for beam energy adjustments to experimental areas, where no helium cryogenic systems exist. The described cryomodule may also be the critical part of a turnkey system with application to material processing, semiconductor manufacturing, food irradiation and homeland security. The development of low heat loss peripheral components reduces cost and widens applicability of the system. We will discuss the cryomodule and RF coupler designs, including numerical thermal and structural analyses.

43 PARTICLE ACCELERATORS↗

Experimental Realization of One-Dimensional Helium

Abstract As the spatial dimension is lowered, locally stabilizing interactions are reduced, leading to the emergence of strongly fluctuating phases of matter without classical analogues. Realizing 1D platforms has been elusive, due to their inherent lack of stability, with a few notable exceptions such as spin chains and ultracold low-density gasses. The inability of such systems to exhibit long range order is essential to their universal description in terms of the Tomonaga-Luttinger liquid theory. Here we report on the experimental observation of a one-dimensional quantum liquid of $$^4$$ 4 He using nanoengineering to confine it within a porous material preplated with a noble gas to enhance dimensional reduction. The resulting excitations of the confined $$^4$$ 4 He, confirmed by neutron scattering, are qualitatively different than three- and two-dimensional superfluid helium, and consistent with Quantum Monte Carlo calculations. The results can be analyzed in terms of a mobile impurity in an otherwise linear Luttinger liquid allowing for the extraction of the microscopic parameters describing the emergent quantum liquid.

Sokol, Paul E.↗

Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

Source record↗

Design of Muon Campus full flow purifier for varying operational conditions and horizontal shipping

Constant ingress of impurities in Muon Campus g-2 experiment at Fermilab has resulted in reduction of efficiency of cryogenic expanders and occasional undesired downtime to flush the impurities. Due to insufficiency of current 0.06 kg/s mobile purifier, a full flow purifier is designed to be used in Muon Campus which purifies 0.24 kg/s of Helium throughput of 4 compressors through charcoal bed at 80 K and returns ambient Helium back to the system. The purifier is designed to be operated near liquid Nitrogen temperature during cold operations and up to 400 K during regeneration. Both warm and cold operational range of the purifier has required use of appropriate clearances in design due to expansion and contraction. The vessel of around 5.5 m height which is designed to be operated vertically is to be shipped horizontally. The asymmetrical position of heavy stainless steel heat exchanger in the purifier support frame and 5g vertical load design consideration for shipping has required use of shipping supports and heat exchanger rotational stops to comply with design requirements. FEA of purifier system is performed in cold, warm and shipping cases to verify that the purifier satisfies the design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen induced dislocation core reconstruction in bcc tungsten

Dislocation, playing a crucial role in the plastic deformation of metals, can be significantly affected by introducing solute elements. Hydrogen (H) embrittlement is one such example, while the underlying mechanism for H affected dislocation structural stability and mobility remains unclear and the role of H has been controversial. Here, using first-principles calculations, we demonstrate that the effect of H on screw dislocation in bcc tungsten (W) is H concentration-dependent, signified by a H-induced transition of SD core structure. At low concentrations of H segregation, dislocation maintains the intrinsic easy-core structure, and H atoms are attached to the “periphery” of dislocation to enhance dislocation motion. In contrast, at high H concentrations, dislocation transforms into a hard-core, metal hydride-like structure, as H atoms become the “body” of dislocation to significantly reduce the dislocation mobility in W. Further, such local easy-to-hard transition can also be induced by the other solutes, including helium, carbon, nitrogen and oxygen. Our work sheds new light on the H-dislocation interactions in bcc W, having broad implications in the interstitial solute-related phenomena.

36 MATERIALS SCIENCE↗

Deployable Cryocooler Based Cryomodule

Superconducting Radio Frequency (SRF) linear accelerators (linacs) have shown tremendous promise in extending the intensity frontier of particle accelerator technology. However, they are large and complex systems, requiring a central refrigeration system and complex piping to distribute liquid helium and nitrogen to the accelerating cavities. In response to these problems, RadiaBeam Technologies, LLC. proposes to develop a small mobile cryomodule that can be safely deployed to its planned field location. The scope of this work is to provide RadiaBeam with the specifications for a complete 650 MHz RF cavity model that can be incorporated into a compact SRF accelerator. Fermilab’s contribution will involve sharing contact resistance measurements, design parameters, and solid models. Design parameters will include the cavity frequency and gradient, length of the linac, number of cryocoolers, etc. This will ensure that the design is useful for practical linacs. A complete cryomodule design is envisioned. Radiabeam will design the cryomodule based on input from Fermilab’s experience on conduction cooling and the needs for a compact SRF accelerator.

43 PARTICLE ACCELERATORS↗

Room-Temperature Determination of Two-Dimensional Electron Gas Concentration and Mobility in Heterostructures

A technique for determination of room-temperature two-dimensional electron gas (2DEG) concentration and mobility in heterostructures is presented. Using simultaneous fits of the longitudinal and transverse voltages as a function of applied magnetic field, we were able to separate the parameters associated with the 2DEG from those of the parallel layer. Comparison with the Shubnikov-de Haas data derived from measurements at liquid helium temperatures proves that the analysis of the room-temperature data provides an excellent estimate of the 2DEG concentration. In addition we were able to obtain for the first time the room-temperature mobility of the 2DEG, an important parameter to device application. Both results are significantly different from those derived from conventional Hall analysis.

Schacham, S. E.↗

NASA Tech Briefs, October 2012

Topics discussed include: Detection of Chemical Precursors of Explosives; Detecting Methane From Leaking Pipelines and as Greenhouse Gas in the Atmosphere; Onboard Sensor Data Qualification in Human-Rated Launch Vehicles; Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride; A Probabilistic Mass Estimation Algorithm for a Novel 7-Channel Capacitive Sample Verification Sensor; Low-Power Architecture for an Optical Life Gas Analyzer; Online Cable Tester and Rerouter; A Three-Frequency Feed for Millimeter-Wave Radiometry; Capacitance Probe Resonator for Multichannel Electrometer; Inverted Three-Junction Tandem Thermophotovoltaic Modules; Fabrication of Single Crystal MgO Capsules; Inflatable Hangar for Assembly of Large Structures in Space; Mars Aqueous Processing System; Hybrid Filter Membrane; Design for the Structure and the Mechanics of Moballs; Pressure Dome for High-Pressure Electrolyzer; Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings; Compact, Low-Force, Low-Noise Linear Actuator; Ultra-Compact Motor Controller; Extreme Ionizing-Radiation-Resistant Bacterium; Wideband Single-Crystal Transducer for Bone Characterization; Fluorescence-Activated Cell Sorting of Live Versus Dead Bacterial Cells and Spores; Nonhazardous Urine Pretreatment Method; Laser-Ranging Transponders for Science Investigations of the Moon and Mars; Ka-Band Waveguide Three-Way Serial Combiner for MMIC Amplifiers; Structural Health Monitoring with Fiber Bragg Grating and Piezo Arrays; Low-Gain Circularly Polarized Antenna with Torus-Shaped Pattern; Stereo and IMU- Assisted Visual Odometry for Small Robots; Global Swath and Gridded Data Tiling; GOES-R: Satellite Insight; Aquarius iPhone Application; Monitoring of International Space Station Telemetry Using Shewhart Control Charts; Theory of a Traveling Wave Feed for a Planar Slot Array Antenna; Time Manager Software for a Flight Processor; Simulation of Oxygen Disintegration and Mixing With Hydrogen or Helium at Supercritical Pressure; A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling; Sapphire Viewports for a Venus Probe; The Mobile Chamber; Electric Propulsion Induced Secondary Mass Spectroscopy; and Radiation-Tolerant DC-DC Converters.

Source record↗

Hazardous Gas Leak Analysis in the Space Shuttle

Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.

Barile, Ronald G.↗

Helium causing disappearance of a/2<111> dislocation loops in binary Fe-Cr ferritic alloys

In this work, single and dual-beam self-ion irradiations were performed at 500°C on ultra-high purity Fe14%Cr alloy to ~0.33 displacements-per-atom (dpa), and 0 or 3030 atomic-parts-per-million (appm) helium/dpa, respectively. Using transmission electron microscopy, we reveal that helium can drastically modify the dislocation loop Burgers vector in Fe-Cr alloys. Helium co-implantation caused complete disappearance of a/2<111> type dislocation loops, and the microstructure consisted of only a<100> loops. Conversely, a/2<111> type loops were predominant without He co-implantation. The total loop density remained largely unaffected. The results strikingly contrast literature asserting that helium stabilizes a/2<111> type loops in bcc Fe alloys, based on low temperature irradiations. Collectively analyzing the results with literature suggest that the small positive interaction between helium and self-interstitial atoms (SIA) in Fe predicted by atomistic simulations maybe insufficient to holistically explain the dislocation loop microstructure development in presence of helium. Helium-SIA positive binding inadvertently implies elevated a/2<111> loop fraction and higher loop densities that the present results contradict. Helium induced high cavity density causing a preferential loss of highly glissile <111> clusters, leaving the matrix saturated with <100> type clusters is proposed as a potential mechanism. Further, the in-situ irradiations combined with Burgers vector analysis strengthened the evidence of Cr-induced dislocation loop mobility reduction that appears to stabilize the a/2<111> type loops and causes higher loop densities in Fe-Cr alloys.

36 MATERIALS SCIENCE↗

Response of 11 B enriched ZrB 2 ultra-high temperature ceramic to neutron irradiation at elevated temperatures

ZrB 2 , an ultra-high temperature ceramic (UHTC) is being considered for use in fusion reactor first-wall structures, yet its response to irradiation remains poorly understood. This study employed scanning/transmission electron microscopy (S/TEM), synchrotron X-ray diffraction (XRD), finite element calculations, and thermal property measurements to thoroughly investigate the neutron-irradiation effects on 11 B-enriched ZrB 2 . Neutron irradiations were conducted at 220 °C and 620 °C, with a neutron fluence of 2.2 × 10 25 neutron/m 2 (energy > 0.1 MeV), resulting in 3.9 dpa and 4200 appm He. The study revealed the unusual prevalence of prism loops and a > c anisotropic lattice swelling, likely linked to the low c/a ratio of ZrB 2 , leading to grain boundary microcracking. Reducing the grain sizes was effective in reducing intergranular cracking and macroscopic swelling. The observation of cavities in ZrB 2 irradiated at 620 °C, as opposed to 220 °C, prompts questions about the temperature at which vacancies in ZrB 2 become mobile, and the role of neutron absorption by 10 B in elevating irradiation temperatures. Isotopic enrichment in 11 B proves to be a viable strategy for mitigating helium production in transition-metal diborides, which is a critical consideration for nuclear applications. Irradiation-induced defects reduce the thermal diffusivity and conductivity of ZrB 2 by a factor of 4–9, which has important implications for its role as a plasma-facing material in fusion reactors that drive high heat fluxes through first-wall materials. Here, this comprehensive study lays the foundation for understanding ZrB 2 behavior under neutron irradiation and highlights important phenomena to consider for various material applications.

36 MATERIALS SCIENCE↗