Search NASA⌕ Search

SEARCH · Search NASA

Results for “high frequency of measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

River thorium concentrations can record bedrock fracture processes including some triggered by distant seismic events

Fractures are integral to the hydrology and geochemistry of watersheds, but our understanding of fracture dynamics is very limited because of the challenge of monitoring the subsurface. Here we provide evidence that long-term, high-frequency measurements of the river concentration of the ultra-trace element thorium (Th) can provide a signature of bedrock fracture processes spanning neighboring watersheds in Colorado. River Th concentrations show abrupt (subdaily) excursions and biexponential decay with approximately 1-day and 1-week time constants, concentration patterns that are distinct from all other solutes except beryllium and arsenic. The patterns are uncorrelated with daily precipitation records or seasonal trends in atmospheric deposition. Groundwater Th analyses are consistent with bedrock release and dilution upon mixing with river water. Most Th excursions have no seismic signatures that are detectable 50 km from the site, suggesting the Th concentrations can reveal aseismic fracture or fault events. We find, however, a weak statistical correlation between Th and seismic motion caused by distant earthquakes, possibly the first chemical signature of dynamic earthquake triggering, a phenomenon previously identified only through geophysical methods.

58 GEOSCIENCES↗

ARM data-oriented metrics and diagnostics package for climate model evaluation (ARM-DIAGS-V3) version 3

A Python-based metrics and diagnostics package is currently being developed by the ARM Infrastructure Team at Lawrence Livermore National Laboratory to facilitate the use of long-term high frequency measurements from the ARM program in evaluating the regional climate simulation of clouds, radiation, precipitation, and aerosols. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The CMIP model data sets are also included in the package to enable model inter-comparison as demonstrated in Zhang et al. (2018) and Zhang et al. (2020). The mean of the CMIP model can be served as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, aerosol optical depth, and radiative fluxes, with plan to extend to more fields, such as the evaluation of model simulated aerosol physicochemical properties and cloud microphysics properties. Process-oriented diagnostics focusing on aerosol, cloud, and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. In addition to the Southern Great Plains (SGP), North Slope of Alaska (NSA) and Tropical Western Pacific (TWP) atmospheric observatories in the ARMDIAGS version 2.0, the version 3.0 package have extended to the data collected at the ARM Eastern North Atlantic (ENA) atmospheric observatory and the Observation and Modeling of the Green Ocean Amazon (GOAMAZON) field campaign. The metrics and diagnostics package are currently built upon standard Python libraries and additional Python packages developed by DOE (CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first provide an overview of major metrics in section 2. The input data, which constitutes the core content of the metrics and diagnostics package, is summarized in section 3. A user's guide documenting the workflow/structure of the version 3.0 codes and including step-by-step instruction for running the package is described in section 4.

54 ENVIRONMENTAL SCIENCES↗

Hydropower Biological Evaluation Toolset Best Practice Guide

Field studies using live fish are necessary for the evaluation of turbine biological performance, but they cannot determine the specific hydraulic conditions or physical stresses experienced by the fish, the locations where deleterious conditions occur, or the specific causes of the biological response. Using the Sensor Fish (SF) sensing technology, this deficiency can be overcome because the SF can be released independently or concurrently with live fish directly into operating infrastructure, and it takes high-frequency measurements of hydraulic conditions such as pressure, acceleration, and rotation acting on a body in situ during downstream passage. The Hydropower Biological Evaluation Tools (HBET; Hou et al. 2018) software package, developed by Pacific Northwest National Laboratory (PNNL), is designed to assemble, organize, and process data collected by the PNNL-developed SF and by live fish. HBET was developed specifically to design SF field studies, process the raw data, and analyze the processed data efficiently and scientifically. Its objectives are to facilitate SF studies focused on characterizing hydraulic conditions and to apply SF data for evaluating the impacts on fish from passage through hydro-structures. HBET allows users to design new studies, analyze data, perform statistical analyses, and evaluate predicted biological responses. It can be used by researchers, turbine designers, hydropower operators, and regulators to evaluate hydro-structures to enhance environmental sustainability in a cost-effective manner.

13 HYDRO ENERGY↗

Event Log / Raw Data

The WFIP3 event log is a curated record spanning 578 days of meteorological phenomena and field observations that complements the campaign’s high-frequency measurements. The log combines manually documented daily weather discussions with automatically derived indicators of key atmospheric processes, providing standardized, publicly available context to support model evaluation, forecast verification, and case-study selection for offshore boundary-layer research.

17 WIND ENERGY↗

Estimating scalar turbulent fluxes with slow-response sensors in the stable atmospheric boundary layer

Conventional and recently developed approaches for estimating turbulent scalar fluxes under stable atmospheric conditions are evaluated, with a focus on gases for which fast sensors are not readily available. First, the relaxed eddy accumulation (REA) classical approach and a recently proposed mixing length parameterization, labeled A22, are tested against eddy-covariance computations. Using high-frequency measurements collected from two contrasting sites (the frozen tundra near Utqiaġvik, Alaska, and a sparsely vegetated grassland in Wendell, Idaho, during winter), it is shown that the REA and A22 models outperform the conventional Monin–Obukhov similarity theory (MOST) utilized widely to infer fluxes from mean gradients. Second, scenarios where slow trace gas sensors are the only viable option in field measurements are investigated using digital filtering applied to fast-response sensors to simulate their slow-response counterparts. With a filtered scalar signal, the observed filtered eddy-covariance fluxes are referred to here as large-eddy-covariance (LEC) fluxes. A virtual eddy accumulation (VEA) approach, akin to the REA model but not requiring a mechanical apparatus to separate the gas flows, is also formulated and tested. A22 outperforms VEA and LEC in predicting the observed unfiltered (total) eddy-covariance (EC) fluxes; however, VEA can still capture the LEC fluxes well. This finding motivates the introduction of a sensor response time correction into the VEA formulation to offset the effect of sensor filtering on the underestimated net averaged fluxes. The only needed parameter for this correction is the mean velocity at the instrument height, a surrogate of the advective timescale. The VEA approach is very suitable and simple to use with gas sensors of intermediate speed (∼ 0.5 to 1 Hz) and with conventional open- or closed-path setups.

58 GEOSCIENCES↗

Strong temporal variation in treefall and branchfall rates in a tropical forest is related to extreme rainfall: results from 5 years of monthly drone data for a 50 ha plot

Abstract. A mechanistic understanding of how tropical-tree mortality responds to climate variation is urgently needed to predict how tropical-forest carbon pools will respond to anthropogenic global change, which is altering the frequency and intensity of storms, droughts, and other climate extremes in tropical forests. We used 5 years of approximately monthly drone-acquired RGB (red–green–blue) imagery for 50 ha of mature tropical forest on Barro Colorado Island, Panama, to quantify spatial structure; temporal variation; and climate correlates of canopy disturbances, i.e., sudden and major drops in canopy height due to treefalls, branchfalls, or the collapse of standing dead trees. Canopy disturbance rates varied strongly over time and were higher in the wet season, even though wind speeds were lower in the wet season. The strongest correlate of monthly variation in canopy disturbance rates was the frequency of extreme rainfall events. The size distribution of canopy disturbances was best fit by a Weibull function and was close to a power function for sizes above 25 m2. Treefalls accounted for 74 % of the total area and 52 % of the total number of canopy disturbances in treefalls and branchfalls combined. We hypothesize that extremely high rainfall is a good predictor because it is an indicator of storms having high wind speeds, as well as saturated soils that increase uprooting risk. These results demonstrate the utility of repeat drone-acquired data for quantifying forest canopy disturbance rates at fine temporal and spatial resolutions over large areas, thereby enabling robust tests of how temporal variation in disturbance relates to climate drivers. Further insights could be gained by integrating these canopy observations with high-frequency measurements of wind speed and soil moisture in mechanistic models to better evaluate proximate drivers and with focal tree observations to quantify the links to tree mortality and woody turnover.

54 ENVIRONMENTAL SCIENCES↗

Investigating lab-scaled offshore wind aerodynamic testing failure and developing solutions for early anomaly detections

As offshore wind systems become more complex, the risk of human error or equipment malfunction increases during experimental testing. This study investigates a lab-scale incident involving a 1 : 50 scale 5 MW wind turbine, where a generator failure led to rotor overspeed and a blade–tower strike. To improve early fault detection, we propose a data-driven method based on multivariate long short-term memory (LSTM) models. High-frequency measurements are projected onto principal components, and anomalies are identified using reconstruction error and its time derivative. Two models are trained on different healthy datasets and tested using single- and multi-principal component (1PC and MPC) variations. Results show that combining both error and error derivative improves detection accuracy. The 1PC model detects faults faster, has a higher recall rate, and achieves a 43 % improvement in anomaly detection accuracy, while the MPC model yields higher precision. This approach provides a simple and effective tool for early anomaly detection in lab-scale experiments, helping to reduce the risk of future failures during the testing of new technologies.

17 WIND ENERGY↗

Statistical Study of the Nonthermal Continuum Radiation Beaming Angle Measured by the High Frequency Receiver on Van Allen Probes-A

The nonthermal continuum (NTC) radiation beaming angle is computed over the entire Van Allen Probes-A mission when the spacecraft was in the dawn sector. The conditions in the dawn sector are favorable for the wave vector to lie near/in the spacecraft's spin plane allowing a favorable estimate of the beaming angle, and the dawn sector is also advantageous in that previous studies show NTC occurrence to peak in this sector. We found that scatter plots, over the entire mission, of beaming angle versus magnetic latitude form a distinct inverted-V pattern, with the apex at/near the magnetic equator. This pattern was sharpest for frequencies ( f ) ≲ 100 kHz. Using the NTC beaming formula from the linear mode conversion theory (LMCT), we show that such an inverted-V pattern is expected due to the large variation in the plasmapause location over the entire mission. The theoretical derived pattern qualitatively reproduces the observed pattern but not quantitatively. The lack of quantitative agreement is discussed and is attributed to several factors, one factor is off-centered emissions from the radio window. The qualitative agreement strongly supports LMCT as being the dominant mechanism generating NTC for f ≲ 100 kHz. For f ≳ 100 kHz, the inverted-V pattern becomes less distinct, and strong near-equatorial beaming is observed. Finally, after considering contamination of our selections by left-handed polarized AKR, our study suggests that besides LMCT another unidentified NTC generation mechanism becomes important for f ≳ 100 kHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Bulk modulus measurement at mHz frequencies and high-pressure using synchrotron x-ray radiation

We report an experimental protocol for measuring the frequency dependence of the bulk modulus carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. An oscillating pressure perturbation characterized by x-ray diffraction produces a volume strain measured by imaging. Together, these yield the bulk modulus of the sample. In this work, we report data at 3 mHz as an example of the possibility of providing these data for the frequency range of 1 mHz–100 mHz.

47 OTHER INSTRUMENTATION↗

Pedestal fluctuation measurements with charge exchange imaging at the DIII-D tokamak

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. Here, the diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 – 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ~ 0.4 cm to access higher k r instabilities (k r < 8 cm –1 ) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing local electron temperature and density inside a sheared flow stabilized Z-pinch using portable optical Thomson scattering

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

47 OTHER INSTRUMENTATION↗

Improving the Quality of Geothermal Data Through Data Standards and Pipelines Within the Geothermal Data Repository: Preprint

For machine learning outputs to be applicable to real world problems, high quality data are needed to ensure high quality results. With the more recent emphasis on machine learning in geothermal, there is an increasing need for greater focus on the quality of the data available for use in these projects. For example, Geothermal Operational Optimization Using Machine Learning (GOOML) utilized large quantities of geothermal power plant operational data to inform power plant operational configurations to maximize power generation. High quality datasets result from dependable sensors or devices collecting data, high frequency of measurements, sufficient data points, adequate metadata, reliable storage of data, and sufficient data curation. Another component that contributes to high quality data is reusability, which can be enhanced through data standardization. Data Standardization creates consistency in formatting and contents of like datasets, lessening preprocessing requirements and ensuring adequate information provided by a given dataset. The Geothermal Data Repository (GDR) aims to help improve data quality through automated data standardization for high-value datasets through the implementation of data pipelines alongside reliable and accessible long-term storage for datasets. As such, the GDR has decided to shift away from recommending the use of Excel-based content models and towards the implementation of automated data pipelines. This takes the burden of data standardization off the user and project team and will increase the availability of standardized geothermal data available through the GDR. A set of recommendations, or a data standard for each data type will exist with each data pipeline in order to advise data collection for maximum usability for future research. This paper serves to describe the GDR's proposed transition towards data standardization through automated data pipelines, to discuss the need for and value of such a shift, and to call for suggestions from the community regarding the most useful data standards and pipelines.

data↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The High-Frequency Signature of Slow and Fast Laboratory Earthquakes

Tectonic faults fail through a spectrum of slip modes, ranging from slow aseismic creep to rapid slip during earthquakes. Understanding the seismic radiation emitted during these slip modes is key for advancing earthquake science and earthquake hazard assessment. In this work, we use laboratory friction experiments instrumented with ultrasonic sensors to document the seismic radiation properties of slow and fast laboratory earthquakes. Stick-slip experiments were conducted at a constant loading rate of 8 μm/s and the normal stress was systematically increased from 7 to 15 MPa. We produced a full spectrum of slip modes by modulating the loading stiffness in tandem with the fault zone normal stress. Acoustic emission data were recorded continuously at 5 MHz. We demonstrate that the full continuum of slip modes radiate measurable high-frequency energy between 100 and 500 kHz, including the slowest events that have peak fault slip rates <100 μm/s. The peak amplitude of the high-frequency time-domain signals scales systematically with fault slip velocity. Stable sliding experiments further support the connection between fault slip rate and high-frequency radiation. Experiments demonstrate that the origin of the high-frequency energy is fundamentally linked to changes in fault slip rate, shear strain, and breaking of contact junctions within the fault gouge. Our results suggest that having measurements close to the fault zone may be key for documenting seismic radiation properties and fully understanding the connection between different slip modes.

58 GEOSCIENCES↗

Comparison of Power System Current Sensors via Playback of Electrical Disturbances

The need to accurately measure high-frequency content in power system voltage and current phenomena is increasingly becoming more of a priority. As the amount of distributed energy resources (DER) and nonlinear loads penetrating the grid increases, so do challenges associated with traditional measurement and metering applications. In this paper, three commercially-available medium-voltage-level current sensors are characterized in terms of their harmonic amplitude and phase performance against reference signals that are “played back” through the sensors through the use of an arbitrary waveform generator. It is shown that none of the three sensors studied are able to faithfully replicate all of the input signals completely, though there are advantages and disadvantages to each in terms of noise, resonance, and induced phase drift. Additionally, the Goodness-of-Fit metric, typically used for PMU model validation, is used to generate side-by-side comparisons of sensor accuracy over a small window around the events under study.

Wilson, Aaron↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Sources of error and methods to improve accuracy in interface state density analysis using quasi-static capacitance–voltage measurements in wide bandgap semiconductors

Characterizing interface trap states in commercial wide bandgap devices using frequency-based measurements requires unconventionally high probing frequencies to account for both fast and slow traps associated with wide bandgap materials. The C - ψs technique has been suggested as a viable quasi-static method for determining the interface trap state densities in wide bandgap systems, but the results are shown to be susceptible to errors in the analysis procedure. Here this work explores the primary sources of errors present in the C - ψs technique using an analytical model that describes the apparent response for wide bandgap MOS capacitor devices. Measurement noise is shown to greatly impact the linear fitting routine of the 1/C$^{*2}_s$ vs Ψ s plot to calibrate the additive constant in the surface potential/gate voltage relationship, and an inexact knowledge of the oxide capacitance is also shown to impede interface trap state analysis near the band edge. In addition, a slight nonlinearity that is typically present throughout the 1/C$^{*2}_s$ vs Ψ s plot hinders the accurate estimation of interface trap densities, which is demonstrated for a fabricated n-SiC MOS capacitor device. Methods are suggested to improve quasi-static analysis, including a novel method to determine an approximate integration constant without relying on a linear fitting routine.

42 ENGINEERING↗