Search NASA⌕ Search

SEARCH · Search NASA

Results for “high penetration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Data-Driven Multi-agent Deep Reinforcement Learning for Distribution System Decentralized Voltage Control with High Penetration of PVs

This paper proposes a novel model-free/data-driven centralized training and decentralized execution multi-agent deep reinforcement learning (MADRL) framework for distribution system voltage control with high penetration of PVs. The proposed MADRL can coordinate both the real and reactive power control of PVs with existing static var compensators and battery storage systems. Unlike the existing DRL-based voltage control methods, our proposed method does not rely on a system model during both the training and execution stages. This is achieved by developing a new interaction scheme between the surrogate modeling of the original system and the multi-agent soft actor critic (MASAC) MADRL algorithm. In particular, the sparse pseudo-Gaussian process with a few-shots of measurements is utilized to construct the surrogate model of the original environment, i.e., power flow model. This is a data-driven process and no model parameters are needed. Furthermore, the MASAC enabled MADRL allows to achieve better scalability by dividing the original system into different voltage control regions with the aid of real and reactive power sensitivities to voltage, where each region is treated as an agent. This also serves as the foundation for the centralized training and decentralized execution, thus significantly reducing the communication requirements as only local measurements are required for control. Comparative results with other alternatives on the IEEE 123-nodes and 342-nodes systems demonstrate the superiority of the proposed method.

14 SOLAR ENERGY↗

Guest Editorial: Special Issue on recent advancements in electric power system planning with high-penetration of renewable energy resources and dynamic loads

The goal of this Special Issue is to present the state-of-the-art methodologies developed for expansion planning of all segments of the modern power systems, characterized by separated businesses, high penetration of renewable resources and new load types, as well as by application of technologically advanced solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexible Oxy-Fuel Combustion for High-Penetration Variable Renewables

A thermodynamic model was developed for the oxy-combustion Allam-Fetvedt cycle. This information was then used to develop an optimized dispatch strategy using price strips supplied by the modeling teams. The price strips represent future possible grid configurations that include a high penetration of variable renewables and a carbon tax. Multiple optimization strategies and tools were used to maximize the net present value (NPV) of the plant on these potential future grids. The optimization varied the size of the air separation unit, the size of oxygen storage tanks, the size of carbon dioxide storage tanks and the flow rate of the carbon dioxide pipeline. The team was able to determine a dispatch strategy that resulted in a positive NPV for all price strips. This indicates that an oxy-combustion plant with oxygen storage would be economically viable on a future grid with a high degree of variable renewables.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

Inertia Estimation Under High Penetration of Inverter-based Resources

Many types of renewable energy sources, especially solar and wind generation, are connected to the electric grid through power-electronic-based interfaces (inverters). These inverter-based resources (IBRs) are mechanically decoupled from the grid, which reduces system inertia and thus may compromise its stability and reliability. In this study, we examine the impact of high penetration of IBRs on the power grid’s inertia. To achieve this, we intentionally introduce disturbances into a simulation case study, such as a step load change, to observe and record the system’s frequency responses. This study offers a nuanced understanding of how the integration of IBRs affects grid stability, and it provides essential guidance for future grid management and resilience strategies.

Yadav, Ajay↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convolution Neural Network for Fault Identification in Distribution Feeder with High Penetration Solar PV

Identification and zonal classification of the faults is a decisive factor in the relay’s decision to trip or not. Different types of fault like three-phase, line-to-line-to-ground and single-line-to-ground can occur at various locations in the feeder. These faults are seen as the variation in the instantaneous values of three-phase voltages and currents, i.e., waveforms, that are measured at the relay location. The objective of this work is to develop a machine learning model that can identify a fault and classify it to various protection zones based on measured waveforms. In this work, a data-driven relay based on Convolutional Neural Network (CNN) is proposed for fault identification in distribution feeders with high penetration solar PV. The proposed CNN model takes local current and voltage waveforms as input and classify it into fault, no-fault or a capacitor switching. Further, the CNN also attempts to identify fault zones based on the images of waveforms. The overall testing accuracy of the trained model exceeds 95%.

Ramesh, Meghana↗

Efficient Phasor-Based Dynamic Volt/VAr and Volt/Watt Analysis of Large Distribution Grid with High Penetration of Smart Inverters

As the penetration of power-electronics based smart inverters (SIs) is increasing in distribution grids, it adds computational challenges in solving dynamic models of large-scale distribution feeders. Voltage and reactive power (Volt/VAr), and voltage and active power (Volt/Watt) dynamics have been analyzed at slower time scales akin to the control of legacy grid devices. However, smart inverters, being power-electronics based devices, can provide dynamic active/reactive power support at a faster time scale, which necessitates Volt/VAr and Volt/Watt dynamics to be analyzed at a faster time scale. The existing dynamic models are overly detailed and computationally intractable for distribution feeders with a large number of inverters. In this context, this proposed work aims towards developing a computationally tractable, scalable, and accurate phasor-based model for dynamic Volt/VAr and Volt/Watt analyses of large distribution systems with high penetration of smart inverters. Case studies demonstrate that the proposed phasor-based model sufficiently captures the Volt/VAr and Volt/Watt dynamics, and is computationally faster by one order of magnitude compared to the average model and by two orders of magnitude compared to the detailed switching model. Case studies also demonstrate the efficacy and scalability of the proposed model in analyzing Volt/VAr and Volt/Watt dynamics of large-scale power networks with hundreds of SIs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of High Penetration Distributed Energy Resources on the Bulk Electric System

The growth of distributed energy resources (DERs), mostly generation using intermittent renewable energy sources, along with the retirement of central generation (mostly conventional power plants using fossil-fuel-based resources) has implications for the steady-state and dynamic performance of the bulk electric system (BES). Among the DERs connected to the distribution system, photovoltaic (PV) systems are the most prevalent and have been installed at an increasing rate. Until recently, the penetration levels of DERs have not been high enough to create significant impacts on the reliability and security of power system operation. However, in recent years, the penetration levels of DERs have risen to a level that their impacts on the bulk electric system should be considered in a detailed fashion in planning and operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

High Penetration Solar and Battery Project in Noatak, Alaska

Through funding from the Department of Energy’s Office of Indian Energy, the Northwest Arctic Borough (NAB) and the Native Village of Noatak (NNV) formed a Tribal Energy Development Organization (TEDO) to implement the Noatak Solar and Battery Project to reduce reliance on costly imported diesel, stabilize energy costs, and strengthen local energy sovereignty.

14 SOLAR ENERGY↗

Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY↗

Sensors with Intelligent Measurement Platform and Low-cost Equipment (SIMPLE) for Monitoring and Control of Medium Voltage Distribution Systems with High Penetration of Intermittent Distributed Energy Resources

The primary focus of the SIMPLE project was to develop, commission, test and introduce intelligent voltage and current sensor platform with enhanced characteristics (accuracy, bandwidth and harmonic range) and high measurement granularity for medium voltage distribution system monitoring, protection and control. The enhancements incorporated existing (commercially available) sensors and made them suitable for applications such as voltage regulation, frequency support, fault detection and location, distribution system state estimation, power quality measurements and electrical distribution network topology processing. The development of the intelligent sensor platform was driven by the need for high-fidelity monitoring and control of medium voltage distribution feeder to enable higher penetration of renewable resources and microgrid operation.

14 SOLAR ENERGY↗

Protection of Distribution Circuits with High Penetration of Solar PV: Distance, Learning, and Estimation-Based Methods

The results of DOE Solar Energy Technologies Office project 34233 are presented. The newest version of IEEE Standard 1547 enables photovoltaic inverters to ride through voltage disturbances, improving bulk system reliability, at the expense of removing undervoltage trip as a fast method of de facto fault detection in high PV adoption scenarios. The project explored new methods of fault detection that don't rely on communication systems and could be available quickly, including distance-based schemes, focused directional relays, and two different data-driven schemes. The schemes were evaluated with fast-phasor simulation, electromagnetic transient simulation, and field data collection at partner utilities Chattanooga Electric Power Board and Dominion Energy Virginia. Accomplishments and possible paths forward are summarized.

14 SOLAR ENERGY↗