Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

Minimum Resolution Requirements for Gamma Identification Algorithms

Each year there are millions of dollars spent on the research and production of high-resolution detectors. This research indicates that the pursuit of higher resolution detectors is not always necessary. The terminal resolution of a NaI detector, or highest detector resolution, at which identification algorithms fail to identify highly enriched uranium (HEU) was evaluated using GADRAS, Genie, and GammaVision. GADRAS employs a template matching algorithm, while Genie and GammaVision utilize a mathematical approach for peak search and identification. The NaI spectra utilized for evaluation were generated using the GADRAS Inject tab and source modeling functions. Each spectrum included terrestrial and cosmic background from Dallas, TX. The resolutions for each spectrum were increased from a default 8.92% to a point where each algorithm would fail to identify 235 U from a HEU source. Six different source configurations were used in this research: bare HEU, 50% shielded HEU, 90% shielded HEU, bare HEU with an interference source of 99 mTc, bare HEU with 99 mTc both shielded 50%, and bare HEU with 99 mTc both shielded 90%. T

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New room temperature high resolution solid-state detector (CdZnTe) for hard x rays and gamma rays

The new CdZnTe high 'Z' material represents a significant improvement in detectors for high energy photons. With the thicknesses available, photons up to 100 keV can be efficiently detected. This material has a wide band gap of 1.5 - 2.2 eV which allows it to operate at room temperature while providing high spectral resolution. Results of resolution evaluations are presented. This detector can be used for high resolution spectral measurements of photons in x-ray and gamma-ray astronomy, offering a significant reduction in the weight, power, and volume of the detector system compared to more conventional detector types such as scintillation counters. In addition, the detector will have the simplicity and reliability of solid-state construction. The CdZnTe detector, as a new development, has not yet been evaluated in space. The Get Away Special program can provide this opportunity.

Stewart, Amyelizabeth C.↗

Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗

Spectral slicing X-ray telescope

Layered synthetic microstructure (LSM) X-ray optics is investigated as a system for coupling a conventional glancing incidence X-ray mirror to a high sensitivity X-ray detector. It is shown that, by the use of figured LSM optics, it is possible to magnify the X-ray image produced by the primary mirrors so as to maintain their high inherent spatial resolution. The results of theoretical and design analyses of several spectral slicing X-ray telescope systems that utilize LSM mirrors of hyperboloidal, spherical, ellipsoidal, and constant optical path aspheric configurations are presented. It is shown that the spherical LSM optics are the preferred configuration, yielding subarcsecond performance over the entire field. The Stanford/Marshall Space Flight Center Rocket X-ray Telescope, which will utilize normal incidence LSM optics to couple a Wolter-Schwarzschild primary mirror to high resolution detectors for solar X-ray/EUV studies, is discussed. Design diagrams are included.

Hoover, R. B.↗

Controlled Shifts of X-ray Emission Lines Measured with Transition Edge Sensors at the Advanced Photon Source

The measurement of shifts in the energy of X-ray emission lines is important for understanding the electronic structure and physical properties of materials. In this study, we demonstrate a method using a synchrotron source to introduce controlled eV-scale shifts of a narrow line in between fixed-energy fluorescence lines. We use this to characterize the ability of a hard X-ray superconducting Transition Edge Sensor (TES) array to measure line shifts. Fixed fluorescence lines excited by higher harmonics of the monochromatic X-ray beam are used for online energy calibration, while elastic scattering from the primary harmonic acts as the variable energy emission line under study. We use this method to demonstrate the ability to track shifts in the energy of the elastic scattering line of magnitude smaller than the TES energy resolution, and find we are ultimately limited by our calibration procedure. The method can be applied over a wide X-ray energy range and provides a robust approach for the characterization of the ability of high-resolution detectors to detect X-ray emission line shifts, and the quantitative comparison of energy calibration procedures.

Guruswamy, Tejas (ORCID:0000000241656765)↗

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

43 PARTICLE ACCELERATORS↗

Optimization Studies of Radiation Shielding for PIP-II Project at Fermilab

The Proton Improvement Plan-II (PIP-II) at Fermilab represents a significant advancement in the quest to answer some of the most profound questions about our universe using the world's most intense high-energy neutrino beam. The project requires the construction of a new addition to the Fermilab accelerator complex – an 800-MeV high-intensity superconducting linear accelerator. Ensuring the safety and regulatory compliance of this ambitious project is paramount, necessitating thorough dose rate assessments under both normal operational and accidental scenarios to align with the Fermilab Radiological Control Manual (FRCM) standards. Our approach included a shielding optimization used for the simulations with the Monte Carlo code MARS [1,2,3] to incorporate new magnet and collimator designs, essential for reflecting the current state of PIP-II infrastructure. The implementation of high-resolution detector planes, despite their computational demands, enabled us to gather detailed radiation field data crucial for optimizing shielding configurations. To overcome the significant computational demands, we developed a branching code that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through geometry splitting and the application of Russian Roulette techniques, tailored to prioritize regions of interest based on predefined importances and weight limits.

Makovec, Alajos↗

Optimization Studies of Radiation Shielding for the PIP-II Project at Fermilab

The PIP-II project at Fermilab, which includes an 800-MeV superconducting LINAC, demands rigorous radiation shielding optimization to meet safety requirements. We updated the MARS geometry model to reflect new magnet and collimator designs and introduced high-resolution detector planes to better capture radiation field distributions. To overcome the significant computational demands, we implemented a well-known branching technique that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through particle splitting and the application of Russian Roulette techniques. Additionally, new graphical tools were created to streamline data visualization and MARS code usability.

Makovec, Alajos [Fermilab] (ORCID:0000000286157492↗

Al-26 - A galactic source of gamma-ray line emission

A detectable gamma-ray line at 1.809 MeV results from the decay of Al-26 in the interstellar medium if this isotope is synthesized in supernovae with abundance of about 0.001 relative to Mg-26. The expected intensity from the direction of the galactic center is approximately 0.0001 photon/sq cm/sec per sr, and the line width is less than 3 keV. This intensity is comparable to the intensities of the other strongest gamma-ray lines resulting from processes of nucleosynthesis at 0.847 MeV from Fe-56, 1.156 MeV from Ca-44, and 1.173 and 1.332 MeV from Ni-60. But the width of the line from Al-26 decay is an order of magnitude smaller than that of either the 0.847- or the 1.156-MeV lines, and hence this line should be much more easily observable with high-resolution detectors.

Ramaty, R.↗

Geometric error analysis for shuttle imaging spectrometer experiment

The demand of more powerful tools for remote sensing and management of earth resources steadily increased over the last decade. With the recent advancement of area array detectors, high resolution multichannel imaging spectrometers can be realistically constructed. The error analysis study for the Shuttle Imaging Spectrometer Experiment system is documented for the purpose of providing information for design, tradeoff, and performance prediction. Error sources including the Shuttle attitude determination and control system, instrument pointing and misalignment, disturbances, ephemeris, Earth rotation, etc., were investigated. Geometric error mapping functions were developed, characterized, and illustrated extensively with tables and charts. Selected ground patterns and the corresponding image distortions were generated for direct visual inspection of how the various error sources affect the appearance of the ground object images.

Wang, S. J.↗