Development of liquid xenon detectors for gamma ray astronomy

The application of liquid xenon in high-resolution detectors for gamma-ray astronomy is being investigated. Initial results from a pulse-shape analysis of ionization signals in a liquid-xenon gridded chamber indicate that it is possible to achieve the necessary liquid purity for the transport of free electrons with simple techniques. The energy resolution has been measured as a function of applied electric field, using electrons and gamma-rays from a 207Bi source. At a field of 12 kV/cm the noise-substracted energy resolution of the dominant 569-keV gamma-ray line is 34 keV FWHM (full width at half maximum). This value is mostly determined by recombination of electron-ion pairs on delta-electron tracks.

Aprile, Elena↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗

Spectral slicing X-ray telescope

Layered synthetic microstructure (LSM) X-ray optics is investigated as a system for coupling a conventional glancing incidence X-ray mirror to a high sensitivity X-ray detector. It is shown that, by the use of figured LSM optics, it is possible to magnify the X-ray image produced by the primary mirrors so as to maintain their high inherent spatial resolution. The results of theoretical and design analyses of several spectral slicing X-ray telescope systems that utilize LSM mirrors of hyperboloidal, spherical, ellipsoidal, and constant optical path aspheric configurations are presented. It is shown that the spherical LSM optics are the preferred configuration, yielding subarcsecond performance over the entire field. The Stanford/Marshall Space Flight Center Rocket X-ray Telescope, which will utilize normal incidence LSM optics to couple a Wolter-Schwarzschild primary mirror to high resolution detectors for solar X-ray/EUV studies, is discussed. Design diagrams are included.

Hoover, R. B.↗

Al-26 - A galactic source of gamma-ray line emission

A detectable gamma-ray line at 1.809 MeV results from the decay of Al-26 in the interstellar medium if this isotope is synthesized in supernovae with abundance of about 0.001 relative to Mg-26. The expected intensity from the direction of the galactic center is approximately 0.0001 photon/sq cm/sec per sr, and the line width is less than 3 keV. This intensity is comparable to the intensities of the other strongest gamma-ray lines resulting from processes of nucleosynthesis at 0.847 MeV from Fe-56, 1.156 MeV from Ca-44, and 1.173 and 1.332 MeV from Ni-60. But the width of the line from Al-26 decay is an order of magnitude smaller than that of either the 0.847- or the 1.156-MeV lines, and hence this line should be much more easily observable with high-resolution detectors.

Ramaty, R.↗

Geometric error analysis for shuttle imaging spectrometer experiment

The demand of more powerful tools for remote sensing and management of earth resources steadily increased over the last decade. With the recent advancement of area array detectors, high resolution multichannel imaging spectrometers can be realistically constructed. The error analysis study for the Shuttle Imaging Spectrometer Experiment system is documented for the purpose of providing information for design, tradeoff, and performance prediction. Error sources including the Shuttle attitude determination and control system, instrument pointing and misalignment, disturbances, ephemeris, Earth rotation, etc., were investigated. Geometric error mapping functions were developed, characterized, and illustrated extensively with tables and charts. Selected ground patterns and the corresponding image distortions were generated for direct visual inspection of how the various error sources affect the appearance of the ground object images.

Wang, S. J.↗

Gamma-ray spectroscopic tests for the anisotropy of accelerated particles in solar flares

The profiles of 0.429 and 0.478 MeV gamma-ray lines from Be-7 and Li-7 (produced by interactions of flare-accelerated alpha particles with ambient He in the solar atmosphere) and of the 4.438 MeV line from C-12 (produced by inelastic scattering of C-12 by accelerated protons) depend on the angular distribution of the interacting accelerated particles. The line profiles resulting from various assumed accelerated-particle angular distributions are calculated and it is shown that it will be possible to distinguish among them using observations of gamma-ray spectra from solar flares obtained with high resolution detectors.

Murphy, R. J.↗

4U1722 + 11 - The discovery of an X-ray selected BL Lac object

The Uhuru X-ray source 4U1722 + 11 was observed using the microchannel-plate detector (High Resolution Imager) on the Einstein Observatory, and its coordinates measured to a precision of about 5 arcsec. A 16th-magnitude stellar object within the error circle was observed spectroscopically at CTIO, and at the AAT, and found to have a featureless continuum. Subsequent radio observations at the VLA have established that the object is a radio source at the level of 60 mJy, and optical polarization measurements have determined that the source exhibits variable polarization at the level of 10 percent. On the basis of these observations, it is concluded that 4U1722 + 11 is a member of the class of objects known as X-ray selected blazars of BL Lac objects.

Griffiths, R. E.↗

Shuttle Space Suit: Fabric/LCVG Model Validation

A detailed space suit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the space suit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of space suit shielding properties assumed the basic fabric layup (Thermal Micrometeoroid Garment, fabric restraints, and pressure envelope) and LCVG could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present space suit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and high-resolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the space suit s protection properties.

Wilson, J. W.↗

Shuttle Spacesuit: Fabric/LCVG Model Validation

A detailed spacesuit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the spacesuit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of spacesuit shielding properties assumed the basic fabric lay-up (Thermal Micrometeroid Garment, fabric restraints, and pressure envelope) and Liquid Cooling and Ventilation Garment (LCVG) could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present spacesuit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and high- resolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the spacesuit's protection properties.

Wilson, J. W.↗

High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron.

Ahlen, S. P.↗

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.↗

Circuit for high resolution decoding of multi-anode microchannel array detectors

A circuit for high resolution decoding of multi-anode microchannel array detectors consisting of input registers accepting transient inputs from the anode array; anode encoding logic circuits connected to the input registers; midpoint pipeline registers connected to the anode encoding logic circuits; and pixel decoding logic circuits connected to the midpoint pipeline registers is described. A high resolution algorithm circuit operates in parallel with the pixel decoding logic circuit and computes a high resolution least significant bit to enhance the multianode microchannel array detector's spatial resolution by halving the pixel size and doubling the number of pixels in each axis of the anode array. A multiplexer is connected to the pixel decoding logic circuit and allows a user selectable pixel address output according to the actual multi-anode microchannel array detector anode array size. An output register concatenates the high resolution least significant bit onto the standard ten bit pixel address location to provide an eleven bit pixel address, and also stores the full eleven bit pixel address. A timing and control state machine is connected to the input registers, the anode encoding logic circuits, and the output register for managing the overall operation of the circuit.

Kasle, David B.↗

Large-format high resolution microchannel plate detectors for ultraviolet astronomy

This report includes work on two types of two-dimensional position-sensitive detectors that were developed in this lab under this award. We worked to develop and optimize the wire-wound helical delay line detector (HDL) in the first and second years. Some early work on the HDL is contained in a paper included as Appendix A. In the second and third years we developed the concept for, then successfully designed and tested, both a lab prototype, and a flight prototype of the first, crossed delay line detector based on two orthogonal serpentine delay lines (SDL). Some of the work on the SDL is contained in a paper included as Appendix B. Appendix C contains copies of the invention report and record.

Martin, Christopher↗

Performance of high resolution decoding with Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a microchannel plate based photon counting detector with applications in ground-based and space-based astronomy. The detector electronics decode the position of each photon event, and the decoding algorithm that associates a given event with the appropriate pixel is determined by the geometry of the anode array. The standard MAMA detector has a spatial resolution set by the anode array of 25 microns, but the MCP pore resolution exceeds this. The performance of a new algorithm that halves the pixel spacing and improves the pixel spatial resolution is described. The new algorithm does not degrade the pulse-pair resolution of the detector and does not require any modifications to the detector tube. Measurements of the detector's response demonstrate that high resolution decoding yields a 60 percent enhancement in spatial resolution. Measurements of the performance of the high resolution algorithm with a 14 micron MAMA detector are also described. The parameters that control high resolution performance are discussed. Results of the application of high resolution decoding to speckle interferometry are presented.

Kasle, David B.↗

Report of the x ray and gamma ray sensors panel

Overall five major areas of technology are recommended for development in order to meet the science requirements of the Astrotech 21 mission set. These are: detectors for high resolution gamma ray spectroscopy, cryogenic detectors for improved x ray spectral and spatial resolution, advanced x ray charge coupled devices (CCDs) for higher energy resolution and larger format, extension to higher energies, liquid and solid position sensitive detectors for improving stopping power in the energy range 5 to 500 keV and 0.2 to 2 MeV. Development plans designed to achieve the desired capabilities on the time scales required by the technology freeze dates have been recommended in each of these areas.

Szymkowiak, Andrew↗