Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution spectroscopy databases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

The Volatile Composition of Comet C/2017 E4 (Lovejoy) before its Disruption, as Revealed by High-Resolution Infrared Spectroscopy with iSHELL at the NASA/IRTF

In 2017 April, we acquired comprehensive high-resolution spectra of newly discovered comet C/2017 E4 (Lovejoy) as it approached perihelion, and before its disintegration. We detected many cometary emission lines in the range (2.8-5.3) μm, in four customized instrument settings (L1-c, L3, Lp1-c, and M1) of iSHELL-the new near-IR high-resolution immersion echelle spectrograph at NASA/IRTF (Maunakea, Hawaii). We identified 12 molecular species: nine primary volatiles (H2O, HCN, NH3, CO, C2H2, C2H6, CH4, CH3OH, H2CO) and three product species (CN, NH2, OH). We detected 85 H2O emission lines from 12 water vibrational bands across L1-c and M1 settings. The many detected water emission lines enabled retrieval of accurate measures for ortho- and para-H2O independently, thereby reducing systematic uncertainty in the derived ortho-para ratio and nuclear spin temperature. Excitation analyses and emission profile analyses were performed for all species, and molecular abundance ratios relative to water are compared with values found for other Oort Cloud comets in our infrared database. Abundance ratios are consistent for most species, with the exception of underabundant methanol and overabundant ammonia in E4.

Faggi, S.↗

The Volatile Composition of Comet C/2017 E4 (Lovejoy) Before Its Disruption, as Revealed by High-Resolution Infrared Spectroscopy with iSHELL at the NASA-IRTF

In April 2017, we acquired comprehensive high-resolution spectra of newly-discovered comet C/2017 E4 (Lovejoy) as it approached perihelion, and before its disintegration. We detected many cometary emission lines in the (2.8–5.3)μm range, in four customized instrument settings (L1-c, L3, Lp1-cand M1) of iSHELL -the new near-IR high resolution immersion echelle spectrograph at NASA/IRTF (Maunakea, Hawaii). We identified twelve molecular species; nine primary volatiles (H2O, HCN, NH3, CO, C2H2, C2H6, CH4, CH3OH, H2CO) and three product species (CN, NH2,OH). We detected 85H2O emission lines from 12 water vibrational bands across L1-c and M1 settings. The many detected water emission lines enabled retrieval of accurate measures for ortho-and para-H2O independently, thereby reducing systematic uncertainty in the derived ortho-para ratio and nuclear spin temperature. Excitation analyses and emission profile analyses were performed for all species, and molecular abundance ratios relative to water are compared with values found for other Oort Cloud comets in our infrared database. Abundance ratios are consistent for most species, with the exception of under-abundant methanol and over-abundant ammonia in E4.

S. Faggi↗

Microwave, Millimeter, Submillimeter, and Far Infrared Spectral Databases

The spectrum of most known astrophysical molecules is derived from transitions between a few hundred to a few hundred thousand energy levels populated at room temperature. In the microwave and millimeter wave regions. spectroscopy is almost always performed with traditional microwave techniques. In the submillimeter and far infrared microwave technique becomes progressively more technologically challenging and infrared techniques become more widely employed as the wavelength gets shorter. Infrared techniques are typically one to two orders of magnitude less precise but they do generate all the strong features in the spectrum. With microwave technique, it is generally impossible and rarely necessary to measure every single transition of a molecular species, so careful fitting of quantum mechanical Hamiltonians to the transitions measured are required to produce the complete spectral picture of the molecule required by astronomers. The fitting process produces the most precise data possible and is required in the interpret heterodyne observations. The drawback of traditional microwave technique is that precise knowledge of the band origins of low lying excited states is rarely gained. The fitting of data interpolates well for the range of quantum numbers where there is laboratory data, but extrapolation is almost never precise. The majority of high resolution spectroscopic data is millimeter or longer in wavelength and a very limited number of molecules have ever been studied with microwave techniques at wavelengths shorter than 0.3 millimeters. The situation with infrared technique is similarly dire in the submillimeter and far infrared because the black body sources used are competing with a very significant thermal background making the signal to noise poor. Regardless of the technique used the data must be archived in a way useful for the interpretation of observations.

Pearson, J. C.↗

High Resolution Spectroscopy to Support Atmospheric Measurements

The major research activities performed during the cooperative agreement enhanced our spectroscopic knowledge of molecules of atmospheric interest such as carbon dioxide, water vapor, ozone, methane, and carbon monoxide, to name a few. Measurements were made using the NASA Langley Tunable Diode Laser Spectrometer System (TDL) and several Fourier Transform Spectrometer Systems (FTS) around the globe. The results from these studies made remarkable improvements in the line positions and intensities for several molecules, particularly ozone and carbon dioxide in the 2 to 17-micrometer spectral region. Measurements of pressure broadening and pressure induced line shift coefficients and the temperature dependence of pressure broadening and pressure induced line shift coefficients for infrared transitions of ozone, methane, and water vapor were also performed. Results from these studies have been used for retrievals of stratospheric gas concentration profiles from data collected by several Upper Atmospheric Research satellite (UARS) infrared instruments as well as in the analysis of high resolution atmospheric spectra such as those acquired by space-based, ground-based, and various balloon- and aircraft-borne experiments. Our results made significant contributions in several updates of the HITRAN (HIgh resolution TRANsmission) spectral line parameters database. This database enjoys worldwide recognition in research involving diversified scientific fields.

Benner, D. Chris↗

High Resolution Spectroscopy to Support Atmospheric Measurements

The major research activities performed during the cooperative agreement enhanced our spectroscopic knowledge of molecules of atmospheric interest such as carbon dioxide, water vapor, ozone, methane, and carbon monoxide, to name a few. Measurements were made using the NASA Langley Tunable Diode Laser Spectrometer System (TDL) and several Fourier Transform Spectrometer Systems (FTS) around the globe. The results from these studies made remarkable improvements in the line positions and intensities for several molecules, particularly ozone and carbon dioxide in the 2 to 17-micrometer spectral region. Measurements of pressure broadening and pressure induced line shift coefficients and the temperature dependence of pressure broadening and pressure induced line shift coefficients for infrared transitions of ozone, methane, and water vapor were also performed. Results from these studies have been used for retrievals of stratospheric gas concentration profiles from data collected by several Upper Atmospheric Research satellite (UARS) infrared instruments as well as in the analysis of high resolution atmospheric spectra such as those acquired by space-based, ground-based, and various balloon-and aircraft-borne experiments. Our results made significant contributions in several updates of the HITRAN (HIgh resolution TRANsmission) spectral line parameters database. This database enjoys worldwide recognition in research involving diversified scientific fields.

Benner, D. Chris↗

High Resolution Spectroscopy to Support Atmospheric Measurements

The major research activities performed during the cooperative agreement enhanced our spectroscopic knowledge of molecules of atmospheric interest such as H2O (water vapor), O3 (ozone), HCN (hydrogen cyanide), CH4 (methane), NO2 (nitrogen dioxide) and CO (carbon monoxide). The data required for the analyses were obtained from two different Fourier Transform Spectrometers (FTS); one of which is located at the National Solar Observatory (NSO) on Kitt Peak, Arizona and the other instrument is located at the Pacific Northwest National Laboratories (PNNL) at Richland, Washington. The data were analyzed using a modified multispectrum nonlinear least squares fitting algorithm developed by Dr. D. Chris Benner of the College of William and Mary. The results from these studies made significant improvements in the line positons and intensities for these molecules. The measurements of pressure broadening and pressure induced line shift coefficients and the temperature dependence of pressure broadening and pressure induced shift coefficients for hundreds of infrared transitions of HCN, CO3 CH4 and H2O were also performed during this period. Results from these studies have been used for retrievals of stratospheric gas concentration profiles from data collected by several Upper Atmospheric Research Satellite (UARS) infrared instruments as well as in the analysis of high resolution atmospheric spectra such as those acquired by space-based, ground-based, and various balloon- and aircraft-borne experiments. Our results made significant contributions in several updates of the HITRAN (HIgh resolution TRANsmission) spectral line parameters database. This database enjoys worldwide recognition in research involving diversified scientific fields. The research conducted during the period 2003-2006 has resulted in publications given in this paper. In addition to Journal publications, several oral and poster presentations were given at various Scientific conferences within the United States and abroad.

Venkataraman, Malathy Devi↗

AstroBiology Explorer Mission Concepts (ABE/ASPIRE)

The AstroBiology Explorer (ABE) and the Astrobiology Space InfraRed Explorer (ASPIRE) Mission Concepts are two missions designed to address the questions (1) Where do we come from? and (2) Are we alone? as outlined in NASA s Origins Program using infrared spectroscopy to explore the identity, abundance, and distribution of molecules of astrobiological importance throughout the Universe. The ABE mission s observational program is focused on six tasks to: (1) Investigate the evolution of ice and organics in dense clouds and star formation regions, and the young stellar/planetary systems that form in them; (2) Measure the evolution of complex organic molecules in stellar outflows; (3) Study the organic composition of a wide variety of solar system objects including asteroids, comets, and the planets and their satellites; (4) Identify organic compounds in the diffuse interstellar medium and determine their distribution , abundance, and change with environment; (5) Detect and identify organic compounds in other galaxies and determine their dependence on galactic type; and (6) Measure deuterium enrichments in interstellar organics and use them as tracers of chemical processes. The ASPIRE mission s observational program expands upon ABE's core mission and adds tasks that (7) Address the role of silicates in interstellar organic chemistry; and (8) Use different resolution spectra to assess the relative roles and abundances of gas- and solid-state materials. ABE (ASPIRE) achieves these goals using a highly sensitive, cryogenically-cooled telescope in an Earth drift-away heliocentric orbit, armed with a suite of infrared spectrometers that cover the 2.5-20(40) micron spectral region at moderate spectral resolution (R>2000). ASPIRE's spectrometer complement also includes a high-resolution (R>25,000) module over the 4-8 micron spectral region. Both missions target lists are chosen to observe a statistically significant sample of a large number of objects of varied types in support of the tasks outline above. The ABE and ASPIRE mission lifetimes are designed to be 14 months and 3 years, respectively, both with significant cryogen and propellant lifetime margins to support an extended observing campaign. The ABE/ASPIRE mission concepts and their supporting Science Teams are led by Principal Investigator Dr. Scott Sandford of NASA s Ames Research Center, with industry partner Ball Aerospace Technologies Ltd., and managed by Jet Propulsion Laboratory. The ABE/ASPIRE Science Operations will be carried out at NASA s Ames Research Center, and the ABE/ASPIRE database will be archived at Caltech/IPAC.

Sandford, Scott↗

The HITRAN2016 Molecular Spectroscopic Database

This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is composed of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 300 additional molecules important in different areas of atmospheric science have been added to the database. The compilation can be accessed through www.hitran.org. Most of the HITRAN data have now been cast into an underlying relational database structure that offers many advantages over the long-standing sequential text-based structure. The new structure empowers the user in many ways. It enables the incorporation of an extended set of fundamental parameters per transition, sophisticated line-shape formalisms, easy user-defined output formats, and very convenient searching, filtering, and plotting of data. A powerful application programming interface making use of structured query language (SQL) features for higher-level applications of HITRAN is also provided.

HITRAN↗