Search NASA⌕ Search

SEARCH · Search NASA

Results for “high temperature gas sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Perovskite-sensitized β-Ga 2 O 3 nanorod arrays for highly selective and sensitive NO 2 detection at high temperature

Amongst various gaseous pollutants, NO 2 is one of the major exhausts originating from fossil fuel and gas combustions in vehicle engines and power plants at high temperature. Under such a scenario, in situ and real-time gas detection and monitoring solutions are largely limited, which hinders the energy-efficient and resource-saving operations of these advanced energy systems. Herein, a new type of perovskite-sensitized β-Ga 2 O 3 nanorod-array has been successfully fabricated to detect NO x at high temperature selectively and sensitively. The demonstrated gas sensors are highly sensitive to NO 2 at 800 °C, with excellent reversible and reproducible response characteristics. Through the surface decoration of perovskite-type La 0.8 Sr 0.2 CoO 3 (LSCO) nanoparticles, the sensitivity of β-Ga 2 O 3 nanorod array gas sensors is enhanced by nearly an order of magnitude, along with much faster response dynamics. A remarkable selectivity toward oxidative gases was also demonstrated with the robust differentiation of NO 2 .

36 MATERIALS SCIENCE↗

Packaging Technologies for High Temperature Electronics and Sensors

This paper reviews ceramic substrates and thick-film metallization based packaging technologies in development for 500 C silicon carbide (SiC) electronics and sensors. Prototype high temperature ceramic chip-level packages and printed circuit boards (PCBs) based on ceramic substrates of aluminum oxide (Al2O3) and aluminum nitride (AlN) have been designed and fabricated. These ceramic substrate-based chip-level packages with gold (Au) thick-film metallization have been electrically characterized at temperatures up to 550 C. A 96% alumina based edge connector for a PCB level subsystem interconnection has also been demonstrated recently. The 96% alumina packaging system composed of chip-level packages and PCBs has been tested with high temperature SiC devices at 500 C for over 10,000 hours. In addition to tests in a laboratory environment, a SiC JFET with a packaging system composed of a 96% alumina chip-level package and an alumina printed circuit board mounted on a data acquisition circuit board was launched as a part of the MISSE-7 suite to the International Space Station via a Shuttle mission. This packaged SiC transistor was successfully tested in orbit for eighteen months. A spark-plug type sensor package designed for high temperature SiC capacitive pressure sensors was developed. This sensor package combines the high temperature interconnection system with a commercial high temperature high pressure stainless steel seal gland (electrical feed-through). Test results of a packaged high temperature capacitive pressure sensor at 500 C are also discussed. In addition to the pressure sensor package, efforts for packaging high temperature SiC diode-based gas chemical sensors are in process.

Chen, Liang-Yu↗

Application of a Physics-Informed Convolutional Neural Network for Monitoring the Temperature Fields in High-Temperature Gas Reactors

Here, this work presents current advances in applying a physics-informed convolutional neural network (CNN) to evaluate temperature distributions in advanced reactors. Our goal is to demonstrate that the CNN can reconstruct temperature fields within the solid region of a prismatic fuel assembly in a high-temperature gas reactor (HTGR) with sensor data available in only a few cooling channels. Before that, we showcase the superior performance of the physics-informed CNN in comparison to a purely data-driven multilayer perceptron (MLP), considering a canonical heated channel setup. This analysis shows the advantages of our approach and justifies its choice. The datasets employed here are obtained upon numerical simulations performed with codes under the Nuclear Energy Advanced Modeling and Simulation program. This work is important, as industry experience indicates that the assembly material in HTGR concepts is prone to large thermal-mechanical loads nearing operational limits. This makes it crucial to characterize peak temperatures and their distributions near hot spots. Modern thermocouples are unreliable in these types of harsh environments because of the high neutron fluxes and elevated temperatures involved. The CNN-based field reconstruction represents an attractive solution, enabling sensor arrays in less aggressive locations and augmenting indirect predictions for less accessible regions. The results show that the CNN reduces prediction errors by orders of magnitude in comparison to the MLP, considering the simple yet well-representative heated channel case. In the case of the HTGR fuel assembly, the CNN can successfully reconstruct temperature fields over various cooling regimes. Furthermore, we also explore the algorithm’s ability to detect abnormalities. Interestingly, the CNN proves it has the capacity to detect blockage in one of the noninstrumented cooling channels.

Machine learning↗

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

An Overview of Wide Bandgap Silicon Carbide Sensors and Electronics Development at NASA Glenn Research Center

A brief overview is presented of the sensors and electronics development work ongoing at NASA Glenn Research Center which is intended to meet the needs of future aerospace applications. Three major technology areas are discussed: 1) high temperature SiC electronics, 2) SiC gas sensor technology development, and 3) packaging of harsh environment devices. Highlights of this work include world-record operation of SiC electronic devices including 500?C JFET transistor operation with excellent properties, atomically flat SiC gas sensors integrated with an on-chip temperature detector/heater, and operation of a packaged AC amplifier. A description of the state-of-the-art is given for each topic. It is concluded that significant progress has been made and that given recent advancements the development of high temperature smart sensors is envisioned.

Hunter, Gary W.↗

A Brief Overview of Relevant Silicon Carbide Electronics and Sensor Development for Long Duration Venus Surface Exploration

This presentation concentrates on the potential of long duration Venus surface missions, and the role of Silicon Carbide (SiC) electronics and sensor advancements in such exploration. For example, SiC integrated circuit (IC) electronics have matured to a state where a simple long-life scientific probe is feasible for extended Venus surface operations. These electronics have been demonstrated for more than a year at 500˚C, and 60 days in high-fidelity simulated Venus surface conditions [1-2]. Further, high temperature chemical sensing technology, including SiC-based gas sensors, integrated with SiC electronics can enable future exploration of the Venus surface atmosphere [3]. Continued maturation of these high temperature electronics and sensors has been part of the Long-Lived In-Situ Solar System Explorer (LLISSE) project to provide an operational system for in situ exploration of the Venus surface up to 60 days [4]. A key focus of this work includes increasing the complexity and decreasing the power consumption of the ICs which will pave the way to enhanced capabilities, such as long-duration Venus seismic measurements and other mission capabilities currently under development. This is in parallel to work expanding the capabilities of the sensor technology to provide science measurements on the Venus surface. This presentation will give an overview of possible extended duration Venus surface exploration and some of the SiC-based technologies that can enable this exploration.

high temperature Venus surface electronics sensors↗

Diode Laser Sensors for Arc-Jet Characterization

The development and application of tunable diode laser (TDL) absorption sensors to monitor the health and operating conditions in the large-scale 60 MW arc-heated- plasma wind-tunnel at NASA Ames Research Center is reported. The interactive heating facility (THF) produces re-entry flow conditions by expanding the gas heated in a constricted plasma arc-heater to flow at high velocity over a model located in a test cabin. This facility provides the conditions needed to test thermal protective systems for spacecraft re-entering the earth s atmosphere. TDL sensors are developed to monitor gas flows in both the high-temperature constricted flow and the supersonic expansion flow into test cabin. These sensors utilize wavelength-tuned diode lasers to measure absorption transitions of atomic oxygen near 777.2 nm, atomic nitrogen near 856.8 nm, and atomic copper near 793.3 nm. The oxygen and nitrogen sensors measure the population density in exited electronic states of these atoms. The measurements combined with the assumption of local thermal and chemical equilibrium yield gas temperature (typically near 7,000K). The nitrogen and oxygen population temperatures are redundant, and their close agreement provides an important test of the local thermal equilibrium assumption. These temperature sensors provide time-resolved monitors of the operating conditions of the arc-heater and can be used to verify and control the test conditions. An additional TDL sensor was developed to monitor the copper concentration in the arc-heater flow yielding values as high as 13 ppm. Measurements of copper in the flow can identify flow conditions with unacceptably rapid electrode erosion, and hence this sensor provides valuable information needed to schedule maintenance to avoid costly arc-heater failure. TDL sensors were also developed for measurements in the test cabin, where absorption measurements of the populations of argon and molecular nitrogen in excited metastable electronic states established that the number density of these excited species is much lower than estimated using frozen-chemistry approximations. This key finding suggests that in the post-expansion region there is not a significant energy sequestration in electronically excited species. Finally, TDL measurements of atomic potassium seeded into the test cabin flow were used to directly measure the static temperature of the test gas. The results of this study illustrate the high potential of time-resolved TDL measurements for routine and economical sensing of arc-heater health (gas temperature and electrode erosion) as well as the time-resolved test-cabin-flow conditions in front of the model.

Hanson, Ronald K.↗

Thermodynamic Modeling of Complex Solid Solutions in the Lu-H-N System via Graph Neural Network Accelerated Monte Carlo Simulations

Metal hydrides are important across diverse applications, such as hydrogen storage, batteries, gas sensors, nuclear reactions, and high-temperature superconductivity. Previous computational studies of metal hydrides under extreme pressures, e.g., 𝑂⁡(10 2 ) ⁢GPa, usually treat them as stoichiometric compounds without considering interstitial lattice disorder. As pressures become more moderate in the 𝑂⁡(10 0 ) ⁢GPa and below range, hydrogen disorder at interstitial lattice sites becomes prominent, e.g., in the N-doped Lu hydride that was recently claimed superconducting near 1 GPa. Further adding compositional complexity from alloying and/or multielement interstitial occupation makes elucidating pressure- and temperature-dependent observables intractable by first-principles calculations alone. We therefore propose a lattice graph neural-network surrogate modeling approach to predict configuration- and pressure-dependent equation-of-state properties. Their efficiency permits Monte Carlo simulations to calculate Gibbs energies and pressure-dependent phase diagrams, thereby revealing insights into the synthesis conditions required for achieving desired phase equilibria. We demonstrate this concept for the compositionally complex cubic Lu(H,N,Va) 3 system where three constituents (hydrogen, nitrogen and vacancy) have disordered multielement interstitial occupancies and insights into pressure-dependent phase equilibria are critically needed, e.g., N-doping levels can significantly lower dehydrogenation temperatures and provide a new strategy to optimize hydrogen-storage alloys. This work can improve the thermodynamic understanding of the Lu-H-N system and help rational synthesis of N-doped Lu hydrides, but more generally demonstrates an efficient approach to model pressure-dependent thermodynamics of multicomponent solid solutions.

Monte Carlo methods↗

Fiberoptics technology and its application to propulsion control systems

Current work on optical sensors and optically controlled actuators for use in air-breathing engine control systems is reviewed with particular reference to the design and operation of several new fiber-optic devices. These include a tachometer, a rotary position encoder, a Fabry-Perot interferometer and a rare-earth sensor for measuring engine gas temperatures, a high-temperature photoswitch designed for the range -55 to 260 C, and optical cables and connectors. The advantages of optics over conventional wire systems used for sensing and actuator control are briefly discussed.

Baumbick, R. J.↗

Research instrumentation for hot section components of turbine engines

Programs to develop research instrumentation for use on hot section components of turbine engines are discussed. These programs can be separated into two categories: one category includes instruments which can measure the environment within the combustor and turbine components, the other includes instruments which measure the response of engine components to the imposed environment. Included in the first category are instruments to measure total heat flux and fluctuating gas temperature. High temperature strain measuring systems, thin film sensors (e.g., turbine blade thermocouples) and a system to view the interior of a combustor during engine operation are programs which comprise the second category. The paper will describe the state of development of these sensors and measuring systems and, in some cases, show examples of measurements made with this instrumentation. The discussion will cover work done at NASA Lewis and at various contractor facilities.

Englund, D. R.↗

Improving Stability of an Optical Fiber pH Sensor with a Calcined Polyethylenimine-Coating at High Pressures and Temperatures

With an increased interest in subsurface gas storage technology for various energy applications, monitoring wellbore structural stability and subsurface geochemistry has become more pressing, and pH is a key parameter to measure. As high pressure and elevated temperatures in subsurface conditions are comparatively harsh relative to that expected for most standard pH sensor designs, any pH monitoring hardware must be designed for extended exposure to high pressures and temperatures. We previously reported that an optical fiber pH sensor functionalized with a calcined polyethylenimine coating had shown some promise as a high temperature and pressure pH sensor but with some drifting when operating for longer than 8 hours. In this paper, we investigated the coating composition and potential cause of the drifting and improved the stability of the prepared coating to minimize sensor drift under simulated wellbore conditions. Scanning electron microscopy (SEM) had previously shown moderate cracking at high pressures over short tests. By applying X-ray photoelectron spectroscopy (XPS) to characterize the sensor coating before and after one week of testing in an H2/CH4 gas blend at 80 °C and 900 psi, a compositional change in the coating was observable, which may indicate susceptibility to alteration by subsurface gas storage conditions. Non-reducing (CH4, N2) environments were also tested, and confirmed that both temperature and pressure were also contributing to the drift.

energy infrastructure↗

Improving Stability of an Optical Fiber pH Sensor with a Calcined Polyethylenimine-Coating at High Pressures and Temperatures

With an increased interest in subsurface gas storage technology for various energy applications, monitoring wellbore structural stability and subsurface geochemistry has become more pressing, and pH is a key parameter to measure. As high pressure and elevated temperatures in subsurface conditions are comparatively harsh relative to that expected for most standard pH sensor designs, any pH monitoring hardware must be designed for extended exposure to high pressures and temperatures. We previously reported that an optical fiber pH sensor functionalized with a calcined polyethylenimine coating had shown some promise as a high temperature and pressure pH sensor but with some drifting when operating for longer than 8 hours. In this paper, we investigated the coating composition and potential cause of the drifting and improved the stability of the prepared coating to minimize sensor drift under simulated wellbore conditions. Scanning electron microscopy (SEM) had previously shown moderate cracking at high pressures over short tests. By applying X-ray photoelectron spectroscopy (XPS) to characterize the sensor coating before and after one week of testing in an H2/CH4 gas blend at 80°C and 900 psi, a compositional change in the coating was observable, which may indicate susceptibility to alteration by subsurface gas storage conditions. Non-reducing (CH4, N2) environments were also tested, and confirmed that both temperature and pressure were also contributing to the drift.

energy infrastructure↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Isolating Gas Sensor From Pressure And Temperature Effects

Two-stage flow system enables oxygen sensor in system to measure oxygen content of low-pressure, possibly-high-temperature atmosphere in test environment while protecting sensor against possibly high temperature and fluctuations in pressure of atmosphere. Sensor for which flow system designed is zirconium oxide oxygen sensor sampling atmospheres in high-temperature wind tunnels. Also adapted to other gas-analysis instruments that must be isolated from pressure and temperature effects of test environments.

Sprinkle, Danny R.↗

Toward local core outlet temperature monitoring in gas-cooled nuclear reactors using distributed fiber-optic temperature sensors

Gas-cooled nuclear reactors operate at temperatures up to 950 °C with significant spatial variations in power generation and coolant flow through hundreds of parallel flow channels, resulting in complex mixing at the core outlet. The high temperatures and complex mixing can damage downstream components, challenge reactor calorimetry for power determination, and result in significant conservatism in calculated peak fuel temperatures, which ultimately limits the total power output. Directly measuring each gas stream individually is unrealistic using single point thermocouples, requiring more robust sensing techniques. Fiber-optic sensors are resilient to high temperatures (up to 1,000 °C) and radiation damage. Moreover, distributed measurements can be made along the length of one fiber, making them potential candidates for monitoring local core outlet temperatures to improve core calorimetry and identify hot channels. Here, to the authors’ knowledge, this manuscript is the first to report spatially distributed fiber optic temperature measurements to quantify mixing at the outlet of a relevant orifice plate under prototypic temperature and flow regimes to assess the feasibility of using fiber-optic sensors for distributed measurements of coolant temperature in gas-cooled reactors. A single optical fiber captured dynamic changes in local temperatures, whereas the mixed outlet temperature exhibited a muted response and could not identify which channels were responsible for the change in the mixed outlet temperature. The discussion focuses on potential challenges for deploying distributed optical fibers in gas-cooled reactors, including the effects of vibrations, radiation-induced signal attenuation and drift, and routing of the fiber while minimizing flow obstructions.

42 ENGINEERING↗

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress↗