Search NASA⌕ Search

SEARCH · Search NASA

Results for “high variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A 1 MA, variable risetime pulse generator for high energy density plasma research

COBRA is a 0.5 {omega} pulse generator driving loads of order 10 nH inductance to >1 MA current. The design is based on independently timed, laser-triggered switching of four water pulse-forming lines whose outputs are added in parallel to drive the load current pulse. The detailed design and operation of the switching to give a wide variety of current pulse shapes and rise times from 95 to 230 ns is described. The design and operation of a simple inductive load voltage monitor are described which allows good accounting of load impedance and energy dissipation. A method of eliminating gas bubbles on the underside of nearly horizontal insulator surfaces in water was required for reliable operation of COBRA; a novel and effective solution to this problem is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Project 57 Air Monitoring Report: October 1, 2013, through December 31, 2014

On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley north east of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DoD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a nonnuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DoD. Various radiological surveys have been performed in the area and in 2007, the DOE expanded the demarked contamination area by posting signs 200 to 400 feet (60 to 120 meters) outside of the original fence. Plutonium in soil is thought to attach preferentially to smaller particles. Therefore, redistribution of soil particulates by wind (dust) is the mechanism most likely to transport plutonium beyond the boundary of the Project 57 contamination area. In 2011, DRI installed two instrumentation towers to measure radiological, meteorological, and dust conditions. The monitoring activity was implemented to determine if radionuclide contamination was detectable in samples of airborne dust and characterize meteorological and environmental parameters that influence dust transport. Collected data also permits comparison of radiological conditions at the Project 57 monitoring stations to conditions observed at Community Environmental Monitoring Program (CEMP) stations around the NTTR. Biweekly samples of airborne particulates are submitted for laboratory assessment of gross alpha and gross beta radioactivity and for determination of gamma-emitting radionuclides. Annual average gross alpha values at the Project 57 monitoring stations are in the same range as the highest two values reported for the CEMP stations surrounding the NTTR. Annual average gross beta values at the Project 57 monitoring stations are slightly higher than the lowest value reported for the CEMP stations surrounding the NTTR. Gamma spectroscopy analyses on samples collected from the Project 57 stations identified only naturally occurring radionuclides. No manmade radionuclides were detected. Thermoluminescent dosimeters (TLDs) indicated that the average annual radioactivity dose at the monitoring stations is higher than the dose determined at surrounding CEMP stations but approximately half of the estimated national average dose received by the general public as a result of exposure to natural sources. The TLDs at the Project 57 monitoring stations are exposed to both natural sources (terrestrial and cosmic) and radioactive releases from the Project 57 contamination area. These comparisons show that the gross alpha, gross beta, and gamma spectroscopy levels at the Project 57 monitoring stations are similar to levels observed at the CEMP stations but that the average annual dose rate is higher than at the CEMP stations. Winds in excess of approximately 15 mph begin to generate dust movement by saltation (migration of sand at the ground surface) or direct suspension in the air. Saltated sand, PM10 (inhalable) dust, and PM2.5 (fine particulate dust) exhibit an approximately exponential increase with increasing wind speed. The greatest concentrations of dust occur for winds exceeding 20 mph. During the reporting period, winds in excess of 20 mph occurred approximately 1.6 percent of the time. Preliminary assessment of individual wind events suggests that dust generation is highly variable likely because of the influence of other meteorological and environmental parameters. Although winds sufficient to generate significant amounts of dust occur at the Project 57 site, they are infrequent and of short duration. Additionally, the potential for wind transport of dust is dependent on other parameters whose influence have not yet been assessed.

54 ENVIRONMENTAL SCIENCES↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗

Interflow dynamics on a low relief forested hillslope: Lots of fill, little spill

In this paper, we evaluated the occurrence of perching and interflow over and within a sandy clay loam argillic horizon within first-order, low-relief, forested catchments at the Savannah River Site (SRS) in the Upper Coastal Plain of South Carolina. We measured soil hydraulic properties, depths to the argillic layer, soil moisture, shallow groundwater behavior, interflow interception trench flows, and streamflow over a 4-year period to explore the nature and variability of soil hydraulic characteristics, the argillic “topography”, and their influence on interflow generation. Perching occurred frequently within and above the restricting argillic horizons during our monitoring period, but interflow was infrequent due to microtopographic relief and associated depression storage on the argillic layer surface. High percolation rates through the argillic horizon, particularly through soil anomalies, also reduced the importance of interflow. Interflow generation was highly variable across eleven segments of a 121 m interception trench. Hillslopes were largely disconnected from stream behavior during storms. Hillslope processes were consistent with the fill-and-spill hypothesis and featured a sequence of distinct thresholds: vertical wetting front propagation to the argillic layer; saturation of the argillic followed by local perching; filling of argillic layer depressions; and finally connectivity of depressions leading to interflow generation. Lastly, analysis of trench flow data indicated a cumulative rainfall threshold of 60 mm to generate interflow, a value at the high end of the range of thresholds reported elsewhere.

54 ENVIRONMENTAL SCIENCES↗

Drivers of stability and transience in composition-functioning links during serial propagation of litter-decomposing microbial communities

ABSTRACT Biotic factors that influence the temporal stability of microbial community functioning are an emerging research focus for the control of natural and engineered systems. The discovery of common features within community ensembles that differ in functional stability over time is a starting point to explore biotic factors. We serially propagated a suite of soil microbial communities through five generations of 28-day microcosm incubations to examine microbial community compositional and functional stability during plant litter decomposition. Using dissolved organic carbon (DOC) abundance as a target function, we hypothesized that microbial diversity, compositional stability, and associated changes in interactions would explain the relative stability of the ecosystem function between generations. Communities with initially high DOC abundance tended to converge towards a “low DOC” phenotype within two generations, but across all microcosms, functional stability between generations was highly variable. By splitting communities into two cohorts based on their relative DOC functional stability, we found that compositional shifts, diversity, and interaction network complexity were associated with the stability of DOC abundance between generations. Further, our results showed that legacy effects were important in determining compositional and functional outcomes, and we identified taxa associated with high DOC abundance. In the context of litter decomposition, achieving functionally stable communities is required to utilize soil microbiomes to increase DOC abundance and long-term terrestrial DOC sequestration as one solution to reduce atmospheric carbon dioxide concentrations. Identifying factors that stabilize function for a community of interest may improve the success of microbiome engineering applications. IMPORTANCE Microbial community functioning can be highly dynamic over time. Identifying and understanding biotic factors that control functional stability is of significant interest for natural and engineered communities alike. Using plant litter–decomposing communities as a model system, this study examined the stability of ecosystem function over time following repeated community transfers. By identifying microbial community features that are associated with stable ecosystem functions, microbial communities can be manipulated in ways that promote the consistency and reliability of the desired function, improving outcomes and increasing the utility of microorganisms.

59 BASIC BIOLOGICAL SCIENCES↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Future Roles of Milli-, Micro-, and Nano- Grids

Although it has slowed considerably, consumption of electricity continues to grow in developed economies. Further, there are some unknowns which might accelerate this growth, such as electrification of vehicle fleets and geothermal heat pump space and water heating. Most analysts anticipate that distributed energy resources (DER) will provide a large share of the expanded generation capacity required to meet this seemingly inexorably increasing electricity demand. Further, given the urgency of tackling the climate change problem, most of the added assets must be carbonfree renewables or nuclear, end-use efficiency improvements, or highly efficient fossil-fired technologies. In developed economies worldwide, the current power delivery paradigm has been in place for more than a century, i.e. since the emergence of polyphase AC systems around the turn of the last century. A key feature of this structure is that, in principle, universal service is delivered at a consistent level of power quality and reliability (PQR) throughout large regions. This paper describes a future possible structure for the electricity generation and delivery system that leaves the existing high voltage meshed grid paradigm in place, but involves radical reorganization of parts of the distribution network and customer sites. Managing a much more diverse dispersed system poses major challenges to the current centralized grid paradigm, particularly since many of these assets are small to tiny by macrogrid standards and they may ultimately number in the millions. They are also not ones that centralized control can rely upon to function in traditionally dependable ways, e.g. renewable generation can be highly variable and changes in output of generators are not independent. Although most involved in the industry agree that a paradigm shift is both necessary and desirable to manage the new system, the nature of the future system remains quite unclear. In the possible structure described here, the traditional grid, or macrogrid, remains similar at the high voltage meshed level. Three new entities are added more locally: community grids or milligrids that operate a segment of the existing distribution system, microgrids which are akin to current customer sites but which have automonous control, and nanogrids, such as telecom or Ethernet networks that currently distribute power to many low-power devices. The latter exist currently in the local electrical systems but are not typically considered a part of the traditional electricity supply system. Because all these new entities exhibit some localized control, providing appropriate local heterogeneous PQR becomes a possibility. These new grid concepts enable a more"bottom-up" approach to electricity distribution, in contrast to the historic 'top-down' model. The future will almost certainly include a mix of the two, but the balance among them and the interface (if any) between them is unclear.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variable Renewable Energy in Long-Term Planning Models: A Multi-Model Perspective

Long-term capacity expansion models of the U.S. electricity sector have long been used to inform electric sector stakeholders and decision-makers. With the recent surge in variable renewable energy (VRE) generators — primarily wind and solar photovoltaics — the need to appropriately represent VRE generators in these long-term models has increased. VRE generators are especially difficult to represent for a variety of reasons, including their variability, uncertainty, and spatial diversity. This report summarizes the analyses and model experiments that were conducted as part of two workshops on modeling VRE for national-scale capacity expansion models. It discusses the various methods for treating VRE among four modeling teams from the Electric Power Research Institute (EPRI), the U.S. Energy Information Administration (EIA), the U.S. Environmental Protection Agency (EPA), and the National Renewable Energy Laboratory (NREL). The report reviews the findings from the two workshops and emphasizes the areas where there is still need for additional research and development on analysis tools to incorporate VRE into long-term planning and decision-making. This research is intended to inform the energy modeling community on the modeling of variable renewable resources, and is not intended to advocate for or against any particular energy technologies, resources, or policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fine-scale landscape characteristics, vegetation composition, and snowmelt timing control phenological heterogeneity across low-Arctic tundra landscapes in Western Alaska

The Arctic is warming at over twice the rate of the rest of the Earth, resulting in significant changes in vegetation seasonality that regulates annual carbon, water, and energy fluxes. However, a crucial knowledge gap exists regarding the intricate interplay among climate, permafrost, and vegetation that generates high phenology variability across extensive tundra landscapes. This oversight has led to significant discrepancies in phenological patterns observed across warming experiments, long-term ecological observations, and satellite and modeling studies, undermining our ability to understand and forecast plant responses to climate change in the Arctic. To address this problem, we assessed plant phenology across three low-Arctic tundra landscapes on the Seward Peninsula, Alaska, using a combination of in-situ phenocam observations and high-resolution PlanetScope CubeSat data. We examined the patterns and drivers of phenological diversity across the landscape by (1) quantifying phenological diversity among dominant plant function types (PFTs) and (2) modeling the interrelations between plant phenology and fine-scale landscape features, such as topography, snowmelt, and vegetation. Our findings reveal that both spring and fall phenology varied significantly across Arctic PFTs, accounting for about 25%–44% and 34%–59% of the landscape-scale variation in the start of spring [SOS] and start of fall [SOF], respectively. Deciduous tall shrubs (e.g. alder and willow) had a later SOS (~7 d behind the mean of other PFTs), but completed leaf expansion (within 2 weeks) considerably faster compared to other PFTs. We modeled the landscape-scale variation in SOS and SOF using Random Forest, which showed that plant phenology can be accurately captured by a suite of variables related to vegetation composition, topographic characteristics, and snowmelt timing (variance explained: 53%–68% for SOS and 59%–82% for SOF). Notably, snowmelt timing was a crucial determinant of SOS, a factor often neglected in most spring phenology models. Our study highlights the impact of fine-scale vegetation composition, snow seasonality, and landscape features on tundra phenological heterogeneity. Improved understanding of such considerable intra-site phenological variability and associated proximate controls across extensive Arctic landscapes offers critical insights for representation of tundra phenology in process models and associated impact assessments with climate change.

54 ENVIRONMENTAL SCIENCES↗

Manufacturing Supply Chain Development for Modular Solar-Thermochemical Conversion Platform [Abstract]

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Concept Overview & Preliminary Analysis

'H2@Scale' is an opportunity for wide-scale use of hydrogen as an intermediate that carries energy from various production options to multiple uses. It is based on identifying and developing opportunities for low-cost hydrogen production and investigating opportunities for using that hydrogen across the electricity, industrial, and transportation sectors. One of the key production opportunities is use of low-cost electricity that may be generated under high penetrations of variable renewable generators such as wind and solar photovoltaics. The technical potential demand for hydrogen across the sectors is 60 million metric tons per year. The U.S. has sufficient domestic renewable resources so that each could meet that demand and could readily meet the demand using a portfolio of generation options. This presentation provides an overview of the concept and the technical potential demand and resources. It also motivates analysis and research on H2@Scale.

30 DIRECT ENERGY CONVERSION↗

Using Electric Vehicles to Meet Balancing Requirements Associated with Wind Power

Many states are deploying renewable generation sources at a significant rate to meet renewable portfolio standards. As part of this drive to meet renewable generation levels, significant additions of wind generation are planned. Due to the highly variable nature of wind generation, significant energy imbalances on the power system can be created and need to be handled. This report examines the impact on the Northwest Power Pool (NWPP) region for a 2019 expected wind scenario. One method for mitigating these imbalances is to utilize plug-in hybrid electric vehicles (PHEVs) or battery electric vehicles (BEVs) as assets to the grid. PHEVs and BEVs have the potential to meet this demand through both charging and discharging strategies. This report explores the usage of two different charging schemes: V2GHalf and V2GFull. In V2GHalf, PHEV/BEV charging is varied to absorb the additional imbalance from the wind generation, but never feeds power back into the grid. This scenario is highly desirable to automotive manufacturers, who harbor great concerns about battery warranty if vehicle-to-grid discharging is allowed. The second strategy, V2GFull, varies not only the charging of the vehicle battery, but also can vary the discharging of the battery back into the power grid. This scenario is currently less desirable to automotive manufacturers, but provides an additional resource benefit to PHEV/BEVs in meeting the additional imbalance imposed by wind. Key findings in the report relate to the PHEV/BEV population required to meet the additional imbalance when comparing V2GHalf to V2GFull populations, and when comparing home-only-charging and work-and-home-charging scenarios. Utilizing V2GFull strategies over V2GHalf resulted in a nearly 33% reduction in the number of vehicles required. This reduction indicates fewer vehicles are needed to meet the unhandled energy, but they would utilize discharging of the vehicle battery into the grid. This practice currently results in the voiding of automotive manufacturer's battery warranty, and is not feasible for many customers. The second key finding is the change in the required population when PHEV/BEV charging is available at both home and work. Allowing 10% of the vehicle population access to work charging resulted in nearly 80% of the grid benefit. Home-only charging requires, at best, 94% of the current NWPP light duty vehicle fleet to be a PHEV or BEV. With the introduction of full work charging availability, only 8% of the NWPP light duty vehicle fleet is required. Work charging has primarily been associated with mitigating range anxiety in new electric vehicle owners, but these studies indicate they have significant potential for improving grid reliability. The V2GHalf and V2GFull charging strategies of the report utilize grid frequency as an indication of the imbalance requirements. The introduction of public charging stations, as well as the potential for PHEV/BEVs to be used as a resource for renewable generation integration, creates conditions for additional products into the ancillary services market. In the United Kingdom, such a capability would be bid as a frequency product in the ancillary services market. Such a market could create the need for larger, third-party aggregators or services to manage the use of electric vehicles as a grid resource. Ultimately, customer adoption, usage patterns and habits, and feedback from the power and automotive industries will drive the need.

17 WIND ENERGY↗

On the Path to SunShot - Emerging Issues and Challenges with Integrating High Levels of Solar into the Distribution System

Wide use of advanced inverters could double the electricity-distribution system’s hosting capacity for distributed PV at low costs—from about 170 GW to 350 GW (see Palmintier et al. 2016). At the distribution system level, increased variable generation due to high penetrations of distributed PV (typically rooftop and smaller ground-mounted systems) could challenge the management of distribution voltage, potentially increase wear and tear on electromechanical utility equipment, and complicate the configuration of circuit-breakers and other protection systems—all of which could increase costs, limit further PV deployment, or both. However, improved analysis of distribution system hosting capacity—the amount of distributed PV that can be interconnected without changing the existing infrastructure or prematurely wearing out equipment—has overturned previous rule-of-thumb assumptions such as the idea that distributed PV penetrations higher than 15% require detailed impact studies. For example, new analysis suggests that the hosting capacity for distributed PV could rise from approximately 170 GW using traditional inverters to about 350 GW with the use of advanced inverters for voltage management, and it could be even higher using accessible and low-cost strategies such as careful siting of PV systems within a distribution feeder and additional minor changes in distribution operations. Also critical to facilitating distributed PV deployment is the improvement of interconnection processes, associated standards and codes, and compensation mechanisms so they embrace PV’s contributions to system-wide operations. Ultimately SunShot-level PV deployment will require unprecedented coordination of the historically separate distribution and transmission systems along with incorporation of energy storage and “virtual storage,” which exploits improved management of electric vehicle charging, building energy systems, and other large loads. Additional analysis and innovation are neede

14 SOLAR ENERGY↗

Advancing the Adoption of High Performance Computing for Time Domain Simulation

Time domain transient stability simulation of large interconnected power systems is becoming increasingly computationally intensive. With the addition of high levels of variable generation that can aggregately ramp over many hours, both the complexity and time horizon for which power system simulations will need to be conducted are increasing. Additionally, extended-term time domain simulation is required to analyze power system security when cascading events across the system span minutes or even hours. Analysis of these occurrences requires modeling power system dynamics over tens of minutes to many hours rather than tens of seconds. Because of the required high computational intensity, there are presently no stability modeling/simulation platforms that combine the needed computational capabilities with the required power system models relevant for representing and analyzing the potential reliability implications of phenomena that occurs over both short- and extended-term dynamic timeframes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overview of Wholesale Electricity Markets

This chapter provides a comprehensive review of four key electricity markets: energy markets (day-ahead and real-time markets); ancillary service markets; financial transmission rights markets; capacity markets. It also discusses how the outcomes of each of these markets may be impacted by the introduction of high penetrations of variable generation. Furthermore, the chapter examines considerations needed to ensure that wholesale market designs are inclusive of emerging technologies, such as demand response, distributed generation, and distributed storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interannual fires as a source for subarctic summer decadal climate variability mediated by permafrost thawing

Climate model simulations run under the Coupled Model Intercomparison Project Phase 6 (CMIP6) use an inhomogeneous biomass burning aerosol (BBA) emission dataset, which exhibits pronounced interannual variability from 1997–2014 due to the infusion of satellite data. Using the Community Earth System Model version 2 Large Ensemble (CESM2-LE) with original and smoothed CMIP6 BBA forcings, we show that the CMIP6 data inhomogeneity causes spurious decadal subarctic land warming. During years with reduced aerosol concentrations, increased solar radiation can trigger abrupt subarctic permafrost thawing, increased soil water drainage, upper soil drying, and subsequent surface warming. This slow process, which is further amplified by nonlinear cloud-aerosol interactions, cannot be completely offset during years of increased aerosol fluxes, thereby reddening surface temperature spectra in response to large-amplitude interannual aerosol forcing. More generally, our CESM2 experiments identify a pathway for generating decadal variability in high latitudes, involving interannual shortwave forcing and slow nonlinear soil responses.

54 ENVIRONMENTAL SCIENCES↗