Search NASA⌕ Search

SEARCH · Search NASA

Results for “histogram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal Evolution and Dose-Volume Histogram Predictors of Visual Acuity After Proton Beam Radiation Therapy of Uveal Melanoma

Purpose: To perform an in-depth temporal analysis of visual acuity (VA) outcomes after proton beam radiation therapy (PBRT) in a large, uniformly treated cohort of uveal melanoma (UM) patients, to determine trends in VA evolution depending on pretreatment and temporally defined posttreatment VA measurements; and to investigate the relevance of specific patient, tumor and dose-volume parameters to posttreatment vision loss. Methods and Materials: Uveal melanoma patients receiving PBRT were identified from a prospectively maintained database. Included patients (n=645) received 56 GyE in 4 fractions, had pretreatment best corrected VA (BCVA) in the affected eye of count fingers (CF) or better, with posttreatment VA assessment at specified post-PBRT time point(s). Patients were grouped according to the pretreatment BCVA into favorable (≥20/40) or unfavorable (20/50-20/400) and poor (CF) strata. Temporal analysis of BCVA changes was described, and univariate and forward stepwise multivariate logistic regression analyses were performed to identify predictors for VA loss. Results: Median VA follow-up was 53 months (range, 3-213 months). At 60-month follow up, among evaluable treated eyes with favorable pretreatment BCVA, 45% retained BCVA ≥20/40, whereas among evaluable treated eyes with initially unfavorable/poor BCVA, 21% had vision ≥20/100. Among those with a favorable initial BCVA, attaining BCVA of ≥20/40 at any posttreatment time point was associated with subsequent maintenance of excellent BCVA. Multivariate analysis identified volume of the macula receiving 28GyE (P<.0001) and optic nerve (P=.0004) as independent dose-volume histogram predictors of 48-month post-PBRT vision loss among initially favorable treated eyes. Conclusions: Approximately half of PBRT-treated UM eyes with excellent pretreatment BCVA assessed at 5 years after treatment will retain excellent long-term vision. 28GyE macula and optic nerve dose-volume histogram parameters allow for rational treatment planning optimization that may lead to improved visual outcomes. The detailed temporal analysis with intermediate as well as long-term functional prognosis, and the relationship of outcomes with clinical and treatment planning parameters, is critical for informed care of UM patients before and after PBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling the dark current histogram induced by gold contamination in complementary-metal-oxide-semiconductor image sensors

We propose a model for dark current induced by metallic contamination in a CMOS image sensor. Based on Shockley-Read-Hall kinetics, the expression of dark current proposed accounts for the electric field enhanced emission factor due to the Poole-Frenkel barrier lowering and phonon-assisted tunneling mechanisms. To that aim, we considered the distribution of the electric field magnitude and metal atoms in the depth of the pixel. Poisson statistics were used to estimate the random distribution of metal atoms in each pixel for a given contamination dose. Then, we performed a Monte-Carlo-based simulation for each pixel to set the number of metal atoms the pixel contained and the enhancement factor each atom underwent, and obtained a histogram of the number of pixels versus dark current for the full sensor. Excellent agreement with the dark current histogram measured on an ion-implanted gold-contaminated imager has been achieved, in particular, for the description of the distribution tails due to the pixel regions in which the contaminant atoms undergo a large electric field. The agreement remains very good when increasing the temperature by 15 °C. We demonstrated that the amplification of the dark current generated for the typical electric fields encountered in the CMOS image sensors, which depends on the nature of the metal contaminant, may become very large at high electric field. The electron and hole emissions and the resulting enhancement factor are described as a function of the trap characteristics, electric field, and temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning using host/guest energy histograms to predict adsorption in metal–organic frameworks: Application to short alkanes and Xe/Kr mixtures

A machine learning (ML) methodology that uses a histogram of interaction energies has been applied to predict gas adsorption in metal–organic frameworks (MOFs) using results from atomistic grand canonical Monte Carlo (GCMC) simulations as training and test data. In this work, the method is first extended to binary mixtures of spherical species, in particular, Xe and Kr. In addition, it is shown that single-component adsorption of ethane and propane can be predicted in good agreement with GCMC simulation using a histogram of the adsorption energies felt by a methyl probe in conjunction with the random forest ML method. Here, the results for propane can be improved by including a small number of MOF textural properties as descriptors. We also discuss the most significant features, which provides physical insight into the most beneficial adsorption energy sites for a given application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-288: Dose Volume Population Histogram (DVPH): A New Method to Evaluate Intensity Modulated Proton Therapy Plans With Geometrical Uncertainties

Purpose: In Proton therapy, especially intensity modulated proton therapy(IMPT), the dose distribution shape is very sensitive to errors due to sharp dose gradients at the Bragg peaks. The concept of the conventional margin is based on the assumption that dose distribution is shifted rather than deformed due to geometrical uncertainties. The goal of this study is to access the validity of the margin concept as well as propose a new approach using Dose Volume Population Histogram (DVPH) in evaluating IMPT plans. Methods: For a prostate case, an intensity modulated proton therapy is optimized based on the conventional PTV based objective function. The plan is evaluated based on the PTV DVH and CTV DVPH (dose volume population histogram) which explicitly taking into account geometric uncertainties. The DVPH is calculated based on 2197 dose distributions at different CTV possible positions for both random and systematic errors. The DVPH with a 90% confidence level is used for the comparison. Results: The minimum dose of the CTV DVPH with a 90% confidence level is only about 18% of the prescribed dose, while the minimum dose of the PTV is 95%. For bladder DVHs, the D50 and D35 is 26% and 30%, compared to 65% and 70% of the prescribed dose from the bladder DVPH with 90% confidence level. Conclusion: The results showed that the PTV concept for ensuring the prescribed dose actually delivered to the CTV is invalid in proton therapy. The good PTV DVH might Result in an underdose to the target and should not be used for IMPT optimization. For OARs, the conventional evaluation approach underestimates dose volume end points. The new concept DVPH has been proved to provide a more accurate DVH evaluation in proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-430: Feasibility Study On Using Overlap Volume Histogram to Predict the Dose Difference by Respiratory Motion

Purpose: The dose difference between three-dimensional dose (3D dose) and 4D dose which considers motion due to respiratory can be varied according to geometrical relationship between planning target volume (PTV) and organ at risk (OAR). The purpose of the study is to investigate the dose difference between 3D and 4D dose using overlap volume histogram (OVH) which is an indicator that quantify geometrical relationship between a PTV and an OAR. Methods: Five liver cancer patients who previously treated stereotactic body radiotherapy (SBRT) were investigated. Four-dimensional computed tomography (4DCT) images were acquired for all patients. ITV-based treatment planning was performed. 3D dose was calculated on the end-exhale phase image as a reference phase image. 4D dose accumulation was implemented from all phase images using dose warping technique used deformable image registration (DIR) algorithm (Horn and Schunck optical flow) in DIRART. In this study OVH was used to quantify geometrical relationship between a PTV and an OAR. OVH between a PTV and a selected OAR was generated for each patient case and compared for all cases. The dose difference between 3D and 4D dose for normal organ was calculated and compared for all cases according to OVH. Results: The 3D and 4D dose difference for OAR was analyzed using dose-volume histogram (DVH). On the basis of a specific point which corresponds to 10% of OAR volume overlapped with expanded PTV, mean dose difference was 34.56% in minimum OVH distance case and 13.36% in maximum OVH distance case. As the OVH distance increased, mean dose difference between 4D and 3D dose was decreased. Conclusion: The tendency of dose difference variation was verified according to OVH. OVH is seems to be indicator that has a potential to predict the dose difference between 4D and 3D dose. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

Flux Histograms for 2017 Analysis

Flux for 2017 Analysis histograms for FHC and RHC:- The fluxes are integrated over the fiducial volume limited by -176 < X <177, -172 < Y < 179 and 25 < Z < 1150 cm. The fluxes are PPFX corrected, and both, the hadron production and focusing systematics are included (see docs 23441 and 17608 for more details).- These fluxes have been made with the official FHC (RHC) ND MC CAFAna files using the function DeriveFlux from CAFAna/XSec/Flux.*.- The root files have two types of histograms: flux_N and fractional_uncertainty_N, where N is the neutrino type. The entries are normalized by 10^6 POT, m2 and the bin width.- The text files contain tables of the flux normalized by 10^6 POT and m2.- The fractional uncertainties are made by the hadron production and beam focusing uncertainties added in quadrature. This corresponds to the sigma fraction respect to the central value and it meant to be used to make an uncertainty band (the covariance matrix is not included yet).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Figure of Merit for Feynman Histograms

Typically a FOM that takes into account the differences between each bin of the histograms, as compared to the magnitude of the combination of the corresponding uncertainties, is used. Because the uncertainties corresponding to the larger multiplet bins are inherently larger than those of the smaller multiplet bins, this type of FOM puts more weight on differences between smaller multiplet bins. New proposed FOM also takes into account sensitivity of leakage multiplication (which is most sensitive to higher multiplet bins) to each bin in the histogram.

97 MATHEMATICS AND COMPUTING↗

NMF-Based Anomaly Detection in CMS 2D Tracking Occupancy Histograms

The CMS experiment relies on Data Quality Monitoring (DQM) to ensure that recorded collision data are suitable for physics analysis. During LHC Run 3, each run contains many lumisections and tracking monitoring elements, making offline inspection challenging, especially for localized detector effects that may appear only for short periods of time. This poster presents an unsupervised machine-learning approach to identify anomalous lumisections in CMS tracking occupancy histograms using Non-Negative Matrix Factorization (NMF). The workflow uses offline CMS DQMIO tracking histograms retrieved with the CMS DIALS API and organized as two-dimensional occupancy maps for each lumisection. After selecting stable lumisections, the occupancy maps are normalized and arranged into a non-negative data matrix. The NMF model learns a compact set of basis patterns describing normal tracking occupancy. Each lumisection is then reconstructed from these learned components, and the reconstruction error is used as an anomaly score. Large residuals indicate occupancy patterns that deviate from normal detector behavior and are flagged for further inspection. This NMF-based approach provides a fast and interpretable way to flag lumisections whose tracking occupancy patterns differ from normal detector behavior. Preliminary studies show sensitivity to known tracking anomalies, and ongoing work is focused on validating the method across additional Run 3 Pixel and Strip detector issues.

Rodríguez Ramos, Iliomar [Puerto Rico U., Mayaguez↗

Spline smoothing of histograms by linear programming

An algorithm for an approximating function to the frequency distribution is obtained from a sample of size n. To obtain the approximating function a histogram is made from the data. Next, Euclidean space approximations to the graph of the histogram using central B-splines as basis elements are obtained by linear programming. The approximating function has area one and is nonnegative.

Bennett, J. O.↗

Multispectral histogram normalization contrast enhancement

A multispectral histogram normalization or decorrelation enhancement which achieves effective color composites by removing interband correlation is described. The enhancement procedure employs either linear or nonlinear transformations to equalize principal component variances. An additional rotation to any set of orthogonal coordinates is thus possible, while full histogram utilization is maintained by avoiding the reintroduction of correlation. For the three-dimensional case, the enhancement procedure may be implemented with a lookup table. An application of the enhancement to Landsat multispectral scanning imagery is presented.

Soha, J. M.↗

Time-cumulated visible and infrared histograms used as descriptor of cloud cover

To study the statistical behavior of clouds for different climate regimes, the spatial and temporal stability of VIS-IR bidimensional histograms is tested. Also, the effect of data sampling and averaging on the histogram shapes is considered; in particular the sampling strategy used by the International Satellite Cloud Climatology Project is tested.

Seze, G.↗

Frequency distribution histograms for the rapid analysis of data

The mean and standard error are good representations for the response of a population to an experimental parameter and are frequently used for this purpose. Frequency distribution histograms show, in addition, responses of individuals in the population. Both the statistics and a visual display of the distribution of the responses can be obtained easily using a microcomputer and available programs. The type of distribution shown by the histogram may suggest different mechanisms to be tested.

NASA Discipline Plant Biology↗

Method for determining a histogram of variable sample rate waveforms

A computer-implemented method comprises receiving a plurality of sampled data points, each data point including a y value and a t value; defining an array of bins, each bin identified by a unique number and including histogram data for a range of y values; for each consecutive pair of data points including a current data point and a next data point, determining a corresponding one of a plurality of linear equations, each linear equation defining a line between the current data point and the next data point; for each line, determining an amount of time that the y value of the line is within the range of values for each bin from the current data point to the next data point; and adding the time to the histogram data for each bin.

Tohlen, Michael Aaron↗

Understanding atom probe’s analytical performance for iron oxides using correlation histograms and ab initio calculations

Abstract Field evaporation from ionic or covalently bonded materials often leads to the emission of molecular ions. The metastability of these molecular ions, particularly under the influence of the intense electrostatic field (10 10 Vm −1 ), makes them prone to dissociation with or without an exchange of energy amongst them. These processes can affect the analytical performance of atom probe tomography (APT). For instance, neutral molecules formed through dissociation may not be detected at all or with a time of flight no longer related to their mass, causing their loss from the analysis. Here, we evaluated the changes in the measured composition of FeO, Fe 2 O 3 and Fe 3 O 4 across a wide range of analysis conditions. Possible dissociation reactions are predicted by density-functional theory calculations considering the spin states of the molecules. The energetically favoured reactions are traced on to the multi-hit ion correlation histograms, to confirm their existence within experiments, using an automated Python-based routine. The detected reactions are carefully analyzed to reflect upon the influence of these neutrals from dissociation reactions on the performance of APT for analysing iron oxides.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dose–volume histogram evaluation scheme for beam orientations in intensity-modulated radiation therapy

Beam orientations in intensity-modulated radiation therapy (IMRT) is an important, but difficult NP-hard optimization problem. A considerable part of this difficulty is due to the essential prerequisite of defining, appropriately, counter-intuitive criteria for a mathematical plan evaluation that coincides with the clinical judgment of the considered plan. Moreover, the quality of beam directions depends heavily on their intensities. Usually a stochastic selector is utilized for optimizing beam orientations, and the intensities are thus calculated many thousands of times, each time for a different selection of beam directions, resulting in excessive time complexity. Therefore, selecting an appropriate set of beam directions in IMRT is still a time-consuming manual trial-and-error search procedure that depends on intuition and empirical knowledge. To overcome these difficulties, this work utilizes the concept of dose–volume histogram (DVH), which is one of the main recognized quantitative measurement tools used for plan judgment, and presents a DVH evaluation scheme that parallelizes plan evaluation with clinical plan judgment. This scheme is then utilized to optimize the intensities of each individual beam, enabling it to be represented by its DVHs, produced for the different irradiated volumes. Finally, an evolutionary algorithm is employed to search for the best combination of those DVHs reflecting the clinical optimal. The presented methods have been applied to three real clinical examples. In comparison to the standard equally spaced beam plans, improvements were reported in all three cases. In comparison with the greedy algorithm, improvements were reported in those examples requiring more than five beam directions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histogram-free multicanonical Monte Carlo sampling to calculate the density of states

Here, we report a new multicanonical Monte Carlo algorithm to obtain the density of states for physical systems with continuous state variables in statistical mechanics. Our algorithm is able to obtain a closed-form expression for the density of states expressed in a chosen basis set, instead of a numerical array of finite resolution as in previous variants of this class of MC methods such as the multicanonical sampling and Wang–Landau sampling. This is enabled by storing the visited states directly and avoiding the explicit collection of a histogram. This practice also has the advantage of avoiding undesirable artificial errors caused by the discretization and binning of continuous state variables. Our results show that this scheme is capable of obtaining converged results with a much reduced number of Monte Carlo steps, leading to a significant speedup over existing algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗