Search NASA⌕ Search

SEARCH · Search NASA

Results for “histograms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Novel Method for the Evaluation of Uncertainty in Dose-Volume Histogram Computation

Purpose: Dose-volume histograms (DVHs) are a useful tool in state-of-the-art radiotherapy treatment planning, and it is essential to recognize their limitations. Even after a specific dose-calculation model is optimized, dose distributions computed by using treatment-planning systems are affected by several sources of uncertainty, such as algorithm limitations, measurement uncertainty in the data used to model the beam, and residual differences between measured and computed dose. This report presents a novel method to take them into account. Methods and Materials: To take into account the effect of associated uncertainties, a probabilistic approach using a new kind of histogram, a dose-expected volume histogram, is introduced. The expected value of the volume in the region of interest receiving an absorbed dose equal to or greater than a certain value is found by using the probability distribution of the dose at each point. A rectangular probability distribution is assumed for this point dose, and a formulation that accounts for uncertainties associated with point dose is presented for practical computations. Results: This method is applied to a set of DVHs for different regions of interest, including 6 brain patients, 8 lung patients, 8 pelvis patients, and 6 prostate patients planned for intensity-modulated radiation therapy. Conclusions: Results show a greater effect on planning target volume coverage than in organs at risk. In cases of steep DVH gradients, such as planning target volumes, this new method shows the largest differences with the corresponding DVH; thus, the effect of the uncertainty is larger.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-204-03: In-Vivo Range Verification and Tissue Response to Proton Radiotherapy Using Prompt Gamma Volume Histograms

Purpose: To study if prompt gamma (PG) volume histograms created from PG images acquired during treatment delivery can be used to identify changes to beam range and tissue composition in response to proton radiotherapy. Methods: Monte Carlo simulations of a single field from a single treatment fraction (100 cGy) for prostate cancer were performed for the cases of: 1) an ideal patient setup, 1) a setup shift in the superior direction and 2) a reduction in oxygen concentration in the tumor. For each case, the 3 -Dimsional dose delivery and elemental PG emission in the patient for the treatment fraction were recorded and imported into a commercial treatment planning system. Changes in the dose volume histograms (DVH), as well as the PG volume histograms (PG-VH) for the PG emission from oxygen and for the total PG emission (from all elements) were analyzed. Results: For the 1 cm superior shift, the prostate DVH and total PG-VH both shifted toward lower doses with the shape of the curves remaining nearly unchanged, resulting in the DVH V95 dropping from 100 cGy to 90 cGy. For the total PG-VH, the V95 fell from 50 to 38. For the reduced oxygen case, both the DVH and PG-VH had a much different shape than for the ideal case, with a significant downward slope in the curves as a function of dose. Conclusions: The shift in the prostate PG-VH for a superior shift in the patient setup correlated well with the DVH indicating it is possible to detect setup errors by analyzing the PG-VH from prompt gamma images obtained during daily proton treatment delivery. Additionally, it may be possible to detect changes in the elemental concentrations of irradiated tissues by analyzing the shape of the PG-VH.

60 APPLIED LIFE SCIENCES↗

SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images

Purpose: To investigate whether pre-treatment images can be used in predicting microsphere distribution in tumors. When intra-arterial radioembolization using Y90 microspheres was performed, the microspheres were often delivered non-uniformly within the tumor, which could lead to an inefficient therapy. Therefore, it is important to estimate the distribution of microspheres. Methods: Early arterial phase CT and FDG PET images were acquired for patients with primary liver cancer prior to radioembolization (RE) using Y90 microspheres. Tumor volume was delineated on CT images and fused with FDG PET images. From each voxel (3.9×3.9×3.3 mm3) in the tumor, the Hounsfield unit (HU) from the CT and SUV values from the FDG PET were harvested. We binned both HU and SUV into 11 bins and then calculated a normalized joint-histogram in an 11×11 array.Patients also underwent a post-treatment Y90 PET imaging. Radiation dose for the tumor was estimated using convolution of the Y90 distribution with a dose-point kernel. We also calculated a fraction of the tumor volume that received a radiation dose great than 100Gy. Results: Averaged over 40 patients, 55% of tumor volume received a dose greater than 100Gy (range : 1.1 – 100%). The width of the joint histogram was narrower for patients with a high dose. For patients with a low dose, the width was wider and a larger fraction of tumor volume had low HU. Conclusion: We have shown the pattern of joint histogram of the HU and SUV depends on delivered dose. The patterns can predict the efficacy of uniform intra-arterial delivery of Y90 microspheres.

60 APPLIED LIFE SCIENCES↗

TH-CD-209-03: Feasibility of CBCT-Based Proton Dose Calculation Using a Histogram-Matching Algorithm in Proton Beam Therapy

Purpose: The aim of this study was to confirm On-Board Imager cone-beam computed tomography (CBCT) using a histogram-matching algorithm as a useful method for proton dose calculation in head and neck radiotherapy. Methods: We studied one head and neck phantom and ten patients with head and neck cancer treated using intensity-modulated radiation therapy (IMRT) and proton beam therapy. We modified Hounsfield unit (HU) values of CBCT (mCBCT) using a histogram-matching algorithm. In order to evaluate the accuracy of the proton dose calculation, we compared dose differences in dosimetric parameters (Dmean) for clinical target volume (CTV), planning target volume (PTV) and left parotid and proton ranges (PR) between the planning CT (reference) and CBCT or mCBCT, and gamma passing rates of CBCT and mCBCT. To minimize the effect of organ deformation, we also performed image registration. Results: For patients, the average differences in Dmean for CTV, PTV, and left parotid between planning CT and CBCT were 1.63 ± 2.34%, 3.30 ± 1.02%, and 5.42 ± 3.06%, respectively. Similarly, the average differences between planning CT and mCBCT were 0.20 ± 0.19%, 0.58 ±0.43%, and 3.53 ±2.40%, respectively. The average differences in PR between planning CT and CBCT or mCBCT of a 50° beam for ten patients were 2.1 ± 2.1 mm and 0.3 ± 0.5 mm, respectively. Similarly, the average differences in PR of a 120° beam were 2.9 ± 2.6 mm and 1.1 ± 0.9 mm, respectively. The average dose and PR differences of mCBCT were smaller than those of CBCT. Additionally, the average gamma passing rates of mCBCT were larger than those of CBCT. Conclusion: We evaluated the accuracy of the proton dose calculation in CBCT and mCBCT with the image registration for ten patients. Our results showed that HU modification using a histogram-matching algorithm could improve the accuracy of the proton dose calculation.

60 APPLIED LIFE SCIENCES↗

Open Radiation Monitoring: Histogram Builder Module Design

The Open Radiation Monitoring Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. A modular architecture can be used to reduce more complex systems to a series of single purpose building blocks, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report details the first revision of a prototype circuit that will convert analog pulses directly into a histogrammed data set for further processing. The circuit was designed with both spectroscopy and multiplicity analysis in mind but can, in principle, be used to reduce any raw data stream into a histogram. The number of output channels is limited, and the histogram bin ranges are user configurable to allow for non-uniform and discontinuous bins, which makes it possible to restrict the information being passed down stream if desired. Pulse processing relies entirely on analog circuitry and non- programmable logic, which enables operation without the need for a central processor or other programmable control unit. The circuit remains untested under the Open Radiation Monitoring project due to the closure of the sponsoring program. However, further development and testing is scheduled to take place in support of a purpose-built trusted verification system development effort known as COGNIZANT, which demonstrates the potential benefit of developing a suite of modular trusted system components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Histogram deconvolution - An aid to automated classifiers

It is shown that N-dimensional histograms are convolved by the addition of noise in the picture domain. Three methods are described which provide the ability to deconvolve such noise-affected histograms. The purpose of the deconvolution is to provide automated classifiers with a higher quality N-dimensional histogram from which to obtain classification statistics.

Lorre, J. J.↗

Uncertainties in the Standard Moments, the Derivation of the Y1 to Y8 parameters, and the Derivation of w 1 to w 8 for Feynman Histograms

Momentum is a neutron multiplicity analysis software package that calculates a variety of parameters associated with Feynman histograms. While most of these parameters are documented in Cifarelli and Smith-Nelson, there are some parameters which are not. Most prominent of these are the uncertainties in the standard moments, and this paper will explicitly document these parameters. This paper will also document the higher-order Y n parameters and their associated ω n functions because they may be useful for future applications. The generation of what is referred to as Feynman histograms is not explained here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rectal Dose-Volume Histogram Parameters Are Associated With Long-Term Patient-Reported Gastrointestinal Quality of Life After Conventional and High-Dose Radiation for Prostate Cancer: A Subgroup Analysis of a Randomized Trial

Purpose: We examined whether rectal dose-volume histogram (DVH) parameters were associated with long-term patient-reported gastrointestinal (GI) quality of life (QOL) after conventional (70.2 GyE) or high-dose (79.2 GyE) radiation for prostate cancer. Methods and Materials: Of 64 men with localized prostate cancer alive with a minimum 7-year follow-up after treatment as part of a randomized trial with either 70.2 GyE or 79.2 GyE of external beam radiation at Massachusetts General Hospital, 56 men (88%) returned a QOL questionnaire, and 50 of those men had DVH information. The DVH parameters of the anterior rectal wall were correlated with patient-reported long-term GI QOL using Pearson correlation and t tests. Results: There was a trend toward an association between increased long-term GI dysfunction and higher V60 (p = 0.07), V65 (p = 0.06), V70 (p = 0.09), and V75 (p = 0.09). When dichotomized by their medians, a V60 > 54% (p = 0.04), V70 > 44% (p = 0.06), and V75 > 39% (p = 0.06) were associated with increased long-term GI dysfunction. There was no difference in long-term GI dysfunction between men on the conventional vs. high-dose arms (p = 0.49). Conclusions: Dose-volume histogram parameters of the anterior rectal wall were associated with long-term patient-reported GI QOL after prostate radiation, whereas the dose prescribed to the prostate was not, suggesting that DVH constraints, rather than total prescribed dose, may have the greatest impact on long-term bowel dysfunction, and therefore that continued dose escalation may be feasible if appropriate dose-volume constraints are met.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temporal Evolution and Dose-Volume Histogram Predictors of Visual Acuity After Proton Beam Radiation Therapy of Uveal Melanoma

Purpose: To perform an in-depth temporal analysis of visual acuity (VA) outcomes after proton beam radiation therapy (PBRT) in a large, uniformly treated cohort of uveal melanoma (UM) patients, to determine trends in VA evolution depending on pretreatment and temporally defined posttreatment VA measurements; and to investigate the relevance of specific patient, tumor and dose-volume parameters to posttreatment vision loss. Methods and Materials: Uveal melanoma patients receiving PBRT were identified from a prospectively maintained database. Included patients (n=645) received 56 GyE in 4 fractions, had pretreatment best corrected VA (BCVA) in the affected eye of count fingers (CF) or better, with posttreatment VA assessment at specified post-PBRT time point(s). Patients were grouped according to the pretreatment BCVA into favorable (≥20/40) or unfavorable (20/50-20/400) and poor (CF) strata. Temporal analysis of BCVA changes was described, and univariate and forward stepwise multivariate logistic regression analyses were performed to identify predictors for VA loss. Results: Median VA follow-up was 53 months (range, 3-213 months). At 60-month follow up, among evaluable treated eyes with favorable pretreatment BCVA, 45% retained BCVA ≥20/40, whereas among evaluable treated eyes with initially unfavorable/poor BCVA, 21% had vision ≥20/100. Among those with a favorable initial BCVA, attaining BCVA of ≥20/40 at any posttreatment time point was associated with subsequent maintenance of excellent BCVA. Multivariate analysis identified volume of the macula receiving 28GyE (P<.0001) and optic nerve (P=.0004) as independent dose-volume histogram predictors of 48-month post-PBRT vision loss among initially favorable treated eyes. Conclusions: Approximately half of PBRT-treated UM eyes with excellent pretreatment BCVA assessed at 5 years after treatment will retain excellent long-term vision. 28GyE macula and optic nerve dose-volume histogram parameters allow for rational treatment planning optimization that may lead to improved visual outcomes. The detailed temporal analysis with intermediate as well as long-term functional prognosis, and the relationship of outcomes with clinical and treatment planning parameters, is critical for informed care of UM patients before and after PBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast analysis of molecular dynamics trajectories with graphics processing units-Radial distribution function histogramming

The calculation of radial distribution functions (RDFs) from molecular dynamics trajectory data is a common and computationally expensive analysis task. The rate limiting step in the calculation of the RDF is building a histogram of the distance between atom pairs in each trajectory frame. Here we present an implementation of this histogramming scheme for multiple graphics processing units (GPUs). The algorithm features a tiling scheme to maximize the reuse of data at the fastest levels of the GPU's memory hierarchy and dynamic load balancing to allow high performance on heterogeneous configurations of GPUs. Several versions of the RDF algorithm are presented, utilizing the specific hardware features found on different generations of GPUs. We take advantage of larger shared memory and atomic memory operations available on state-of-the-art GPUs to accelerate the code significantly. The use of atomic memory operations allows the fast, limited-capacity on-chip memory to be used much more efficiently, resulting in a fivefold increase in performance compared to the version of the algorithm without atomic operations. The ultimate version of the algorithm running in parallel on four NVIDIA GeForce GTX 480 (Fermi) GPUs was found to be 92 times faster than a multithreaded implementation running on an Intel Xeon 5550 CPU. On this multi-GPU hardware, the RDF between two selections of 1,000,000 atoms each can be calculated in 26.9 s per frame. The multi-GPU RDF algorithms described here are implemented in VMD, a widely used and freely available software package for molecular dynamics visualization and analysis.

97 MATHEMATICS AND COMPUTING↗

Signatures of Cooperative Effects and Transport Mechanisms in Conductance Histograms

We present a computational investigation into the lineshapes of peaks in conductance histograms, finding that they possess high information content. In particular, the histogram peak associated with conduction through a single molecule elucidates the electron transport mechanism and is generally well-described by beta distributions. A statistical analysis of the peak corresponding to conduction through two molecules reveals the presence of cooperative effects between the molecules and also provides insight into the underlying conduction channels. This work provides tools for extracting additional interpretations from experimental statistical data, helping us better understand electron transport processes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Elucidating the effects of adsorbent flexibility on fluid adsorption using simple models and flat-histogram sampling methods

Using flat-histogram Monte Carlo methods, we investigate the adsorptive behavior of the square-well fluid in two simple slit-pore-like models intended to capture fundamental characteristics of flexible adsorbent materials. Both models require as input thermodynamic information about the flexible adsorbent material itself. An important component of this work involves formulating the flexible pore models in the appropriate thermodynamic (statistical mechanical) ensembles, namely, the osmotic ensemble and a variant of the grand-canonical ensemble. Two-dimensional probability distributions, which are calculated using flat-histogram methods, provide the information necessary to determine adsorption thermodynamics. For example, we are able to determine precisely adsorption isotherms, (equilibrium) phase transition conditions, limits of stability, and free energies for a number of different flexible adsorbent materials, distinguishable as different inputs into the models. While the models used in this work are relatively simple from a geometric perspective, they yield non-trivial adsorptive behavior, including adsorption-desorption hysteresis solely due to material flexibility and so-called “breathing” of the adsorbent. The observed effects can in turn be tied to the inherent properties of the bare adsorbent. Some of the effects are expected on physical grounds while others arise from a subtle balance of thermodynamic and mechanical driving forces. In addition, the computational strategy presented here can be easily applied to more complex models for flexible adsorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated weight histogram method for exploring free energy landscapes

Calculating free energies is an important and notoriously difficult task for molecular simulations. The rapid increase in computational power has made it possible to probe increasingly complex systems, yet extracting accurate free energies from these simulations remains a major challenge. Fully exploring the free energy landscape of, say, a biological macromolecule typically requires sampling large conformational changes and slow transitions. Often, the only feasible way to study such a system is to simulate it using an enhanced sampling method. The accelerated weight histogram (AWH) method is a new, efficient extended ensemble sampling technique which adaptively biases the simulation to promote exploration of the free energy landscape. The AWH method uses a probability weight histogram which allows for efficient free energy updates and results in an easy discretization procedure. A major advantage of the method is its general formulation, making it a powerful platform for developing further extensions and analyzing its relation to already existing methods. Here, we demonstrate its efficiency and general applicability by calculating the potential of mean force along a reaction coordinate for both a single dimension and multiple dimensions. We make use of a non-uniform, free energy dependent target distribution in reaction coordinate space so that computational efforts are not wasted on physically irrelevant regions. We present numerical results for molecular dynamics simulations of lithium acetate in solution and chignolin, a 10-residue long peptide that folds into a β-hairpin. We further present practical guidelines for setting up and running an AWH simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the dark current histogram induced by gold contamination in complementary-metal-oxide-semiconductor image sensors

We propose a model for dark current induced by metallic contamination in a CMOS image sensor. Based on Shockley-Read-Hall kinetics, the expression of dark current proposed accounts for the electric field enhanced emission factor due to the Poole-Frenkel barrier lowering and phonon-assisted tunneling mechanisms. To that aim, we considered the distribution of the electric field magnitude and metal atoms in the depth of the pixel. Poisson statistics were used to estimate the random distribution of metal atoms in each pixel for a given contamination dose. Then, we performed a Monte-Carlo-based simulation for each pixel to set the number of metal atoms the pixel contained and the enhancement factor each atom underwent, and obtained a histogram of the number of pixels versus dark current for the full sensor. Excellent agreement with the dark current histogram measured on an ion-implanted gold-contaminated imager has been achieved, in particular, for the description of the distribution tails due to the pixel regions in which the contaminant atoms undergo a large electric field. The agreement remains very good when increasing the temperature by 15 °C. We demonstrated that the amplification of the dark current generated for the typical electric fields encountered in the CMOS image sensors, which depends on the nature of the metal contaminant, may become very large at high electric field. The electron and hole emissions and the resulting enhancement factor are described as a function of the trap characteristics, electric field, and temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning using host/guest energy histograms to predict adsorption in metal–organic frameworks: Application to short alkanes and Xe/Kr mixtures

A machine learning (ML) methodology that uses a histogram of interaction energies has been applied to predict gas adsorption in metal–organic frameworks (MOFs) using results from atomistic grand canonical Monte Carlo (GCMC) simulations as training and test data. In this work, the method is first extended to binary mixtures of spherical species, in particular, Xe and Kr. In addition, it is shown that single-component adsorption of ethane and propane can be predicted in good agreement with GCMC simulation using a histogram of the adsorption energies felt by a methyl probe in conjunction with the random forest ML method. Here, the results for propane can be improved by including a small number of MOF textural properties as descriptors. We also discuss the most significant features, which provides physical insight into the most beneficial adsorption energy sites for a given application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visibility Histograms and Visibility-Driven Transfer Functions

Direct volume rendering is an important tool for visualizing complex data sets. However, in the process of generating 2D images from 3D data, information is lost in the form of attenuation and occlusion. The lack of a feedback mechanism to quantify the loss of information in the rendering process makes the design of good transfer functions a difficult and time consuming task. In this paper, we present the general notion of visibility histograms, which are multidimensional graphical representations of the distribution of visibility in a volume-rendered image. In this paper, we explore the 1D and 2D transfer functions that result from intensity values and gradient magnitude. With the help of these histograms, users can manage a complex set of transfer function parameters that maximize the visibility of the intervals of interest and provide high quality images of volume data. We present a semiautomated method for generating transfer functions, which progressively explores the transfer function space toward the goal of maximizing visibility of important structures. Our methodology can be easily deployed in most visualization systems and can be used together with traditional 1D and 2D opacity transfer functions based on scalar values, as well as with other more sophisticated rendering algorithms.

42 ENGINEERING↗

BEDVH--A method for evaluating biologically effective dose volume histograms: Application to eye plaque brachytherapy implants

Purpose: A method is introduced to examine the influence of implant duration T, radionuclide, and radiobiological parameters on the biologically effective dose (BED) throughout the entire volume of regions of interest for episcleral brachytherapy using available radionuclides. This method is employed to evaluate a particular eye plaque brachytherapy implant in a radiobiological context. Methods: A reference eye geometry and 16 mm COMS eye plaque loaded with {sup 103}Pd, {sup 125}I, or {sup 131}Cs sources were examined with dose distributions accounting for plaque heterogeneities. For a standardized 7 day implant, doses to 90% of the tumor volume ( {sub TUMOR}D{sub 90}) and 10% of the organ at risk volumes ( {sub OAR}D{sub 10}) were calculated. The BED equation from Dale and Jones and published {alpha}/{beta} and {mu} parameters were incorporated with dose volume histograms (DVHs) for various T values such as T = 7 days (i.e., {sub TUMOR} {sup 7}BED{sub 10} and {sub OAR} {sup 7}BED{sub 10}). By calculating BED throughout the volumes, biologically effective dose volume histograms (BEDVHs) were developed for tumor and OARs. Influence of T, radionuclide choice, and radiobiological parameters on {sub TUMOR}BEDVH and {sub OAR}BEDVH were examined. The nominal dose was scaled for shorter implants to achieve biological equivalence. Results: {sub TUMOR}D{sub 90} values were 102, 112, and 110 Gy for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively. Corresponding {sub TUMOR} {sup 7}BED{sub 10} values were 124, 140, and 138 Gy, respectively. As T decreased from 7 to 0.01 days, the isobiologically effective prescription dose decreased by a factor of three. As expected, {sub TUMOR} {sup 7}BEDVH did not significantly change as a function of radionuclide half-life but varied by 10% due to radionuclide dose distribution. Variations in reported radiobiological parameters caused {sub TUMOR} {sup 7}BED{sub 10} to deviate by up to 46%. Over the range of {sub OAR}{alpha}/{beta} values, {sub OAR} {sup 7}BED{sub 10} varied by up to 41%, 3.1%, and 1.4% for the lens, optic nerve, and lacrimal gland, respectively. Conclusions: BEDVH permits evaluation of the relative biological effectiveness for brachytherapy implants. For eye plaques, {sub TUMOR}BEDVH and {sub OAR}BEDVH were sensitive to implant duration, which may be manipulated to affect outcomes.

61 RADIATION PROTECTION AND DOSIMETRY↗