Search NASA⌕ Search

SEARCH · Search NASA

Results for “hole insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Novel, Miniature Multi-Hole Probes and High-Accuracy Calibration Algorithms for their use in Compressible Flowfields

Two new calibration algorithms were developed for the calibration of non-nulling multi-hole probes in compressible, subsonic flowfields. The reduction algorithms are robust and able to reduce data from any multi-hole probe inserted into any subsonic flowfield to generate very accurate predictions of the velocity vector, flow direction, total pressure and static pressure. One of the algorithms PROBENET is based on the theory of neural networks, while the other is of a more conventional nature (polynomial approximation technique) and introduces a novel idea of local least-squares fits. Both algorithms have been developed to complete, user-friendly software packages. New technology was developed for the fabrication of miniature multi-hole probes, with probe tip diameters all the way down to 0.035". Several miniature 5- and 7-hole probes, with different probe tip geometries (hemispherical, conical, faceted) and different overall shapes (straight, cobra, elbow probes) were fabricated, calibrated and tested. Emphasis was placed on the development of four stainless-steel conical 7-hole probes, 1/16" in diameter calibrated at NASA Langley for the entire subsonic regime. The developed calibration algorithms were extensively tested with these probes demonstrating excellent prediction capabilities. The probes were used in the "trap wing" wind tunnel tests in the 14'x22' wind tunnel at NASA Langley, providing valuable information on the flowfield over the wing. This report is organized in the following fashion. It consists of a "Technical Achievements" section that summarizes the major achievements, followed by an assembly of journal articles that were produced from this project and ends with two manuals for the two probe calibration algorithms developed.

Rediniotis, Othon K.↗

Insertion of an organic interlayer for hole current enhancement in inverted organic light emitting devices

We report the enhancement of hole current density in the hole transport part of an inverted top-emission organic light emitted diode by applying an organic insertion layer of 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile (HAT-CN). Poor hole transporting performance of Al/4,4{sup '}-bis(N-phenyl-1-naphthylamino)biphenyl (NPB)/indium tin oxide is greatly improved by the HAT-CN insertion between Al and NPB layer. The highest occupied molecular orbital level onset of the NPB bends toward Fermi level at the HAT-CN/NPB interface. This extra charge generation layer made of pure organic molecules substantially enhances hole injection from Al anode as revealed by the results of ultraviolet photoelectron spectroscopy and J-V measurement data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sci—Fri PM: Dosimetry — 03: Delta4 diode absolute dose response for large and small target volume IMRT QA

The goal of this project was to quantify the over-response/under-response of the Delta4 diodes for Helical Tomotherapy plans on extreme target volume sizes. A custom Delta4 phantom quarter with a hole to insert an ionisation chamber (IC) close to the center of the phantom have been used to acquire simultaneous IC and diodes absolute dose measurements. Eight plans for different target volumes were created from 20cm to 1cm diameter. Diodes dose measurements in the target were compared with IC measurement, to quantify absolute dose accuracy. IC measurements show a good agreement with planned dose (±2%). Diode measurements demonstrate a good agreement with IC for regular target size of 5 and 10cm (0 to 1%). For larger targets, an over-response is observed for FW 25mm and 10mm (2 to 3%). for small target of 1cm diameter, a major under-response is observed for FW 25mm and 10mm (−8 and −36%). The over-response could to be due to the extra amount of scattered radiation and the opposite for under-response. Although this scatter hypothesis still has to be proven, early testing demonstrates an over-response of 40%/20% of the central diodes compare to IC when an open helical rotational beam is delivered 75mm/25mm away from the center of the phantom. These results are in agreement with the real patient Delta4 DQA results at our center.

60 APPLIED LIFE SCIENCES↗

Evaluation of the Dissolution Behavior of L-Bundle End Caps and HFIR Fuel Carriers

The H-Canyon facility is currently using the 6.1D dissolver for the dissolution of Material Test Reactor (MTR) fuel and the 6.4D dissolver for the dissolution of High Flux Isotope Reactor (HFIR) fuel using mercury-catalyzed HNO₃ dissolution flowsheets. The processing strategy for both dissolvers involves the dissolution of multiple charges of fuel per batch. After the designated heating cycle, the dissolvers are opened, and the charging wells are probed to determine if the MTR or HFIR fuel has dissolved. If undissolved fuel fragments are beyond a certain height, the dissolver must be closed and heated for an additional amount of time to dissolve the remaining material. In recent MTR fuel dissolutions, “high probes” (i.e., excessive undissolved material) were frequently observed, which resulted in extended dissolution times. The suspected cause of the high probes was the incomplete dissolution of the L-Bundle End Cap, rather than the fuel or fuel bundles. The End Cap is hypothesized to be binding in the insert well and not dropping into the acid as the L-Bundle and fuel dissolve. Once the End Cap is dislodged by the probe and drops into the acid, the dissolution rate of the End Cap appears to be significantly reduced compared to the dissolution rate of the fuel and other parts of the L-Bundle. A similar issue has also been observed with the lifting bail on the HFIR fuel carriers. During HFIR fuel dissolutions, the lifting bail on the outer carrier has resulted in high probes due to incomplete dissolution. In one case, a partially dissolved bail was caught in one of the insert well holes which prevented the probe from going to the bottom of the well.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FEP plug protects H2 masers

Lifetime of hydrogen-maser bulb is increased by replacing beam stop plate with thick fluorinated ethylene-propylene (FEP) plug inserted in hole opposite beam entrance stem of bulb.

Deluca, J. J.↗

An oven for many thermocouple reference junctions

Compact, lightweight oven designed with geometric and heating symmetry holds many junctions at stable temperature. Oven has cylindrical wall with all points equidistant from heating coil. Thermocouple junctions are inserted in holes bored radially in wall. Sensor controls power supplied to heating coil, maintaining cylinder wall and junctions at constant temperature.

Leblanc, L. P.↗

Noncontact Measurement Of Critical Current In Superconductor

Critical current measured indirectly via flux-compression technique. Magnetic flux compressed into gap between superconductive hollow cylinder and superconductive rod when rod inserted in hole in cylinder. Hall-effect probe measures flux density before and after compression. Method does not involve any electrical contact with superconductor. Therefore, does not cause resistive heating and consequent premature loss of superconductivity.

Israelsson, Ulf E.↗

Magnetically Operated Holding Plate And Ball-Lock Pin

Magnetically operated holding plate and ball-locking-pin mechanism part of object attached to, or detached from second object. Mechanism includes tubular housing inserted in hole in second object. Plunger moves inside tube forcing balls to protrude from sides. Balls prevent tube from sliding out of second object. Simpler, less expensive than motorized latches; suitable for robotics applications.

Monford, Leo G., Jr.↗

Quick-Connect, Slow-Disconnect Bolt

Proposed bolt functions similarly to device described in article "Quick-Connect, Slow-Disconnect Nut" (MFS-28833). Bolt installed in standard threaded hole simply by pushing it into hole. Once inserted, bolt withdrawn only by turning it in conventional way.

Weddendorf, Bruce↗

Improved Quick-Release Pin Mechanism

An improved quick-release pin mechanism supplants a prior such mechanism in which the pin bears a shear load to hold two objects together. The prior mechanism, of a ball-locking design, can fail when vibrations cause balls to fall out. The load-bearing pin is an outer tube with a handle at one end (hereafter denoted the near end). Within the outer tube is a spring-loaded inner tube that includes a handle at its near end and a pivoting tab at its far end. The pin is inserted through holes in the objects to be retained and the inner tube is pushed against an offset pivot inside the outer tube to make the tab rotate outward so that it protrudes past the outer diameter of the outer tube, and the spring load maintains this configuration so that the pin cannot be withdrawn through the holes. Pushing the handles together against the spring load moves the locking tab out far enough that the tab becomes free to rotate inward. Then releasing the inner-tube handle causes the tab to be pulled into a resting position inside the outer tube. The pin can then be pulled out through the holes.

Wright, Jay M.↗

Enhancing VHTR Passive Safety and Economy with Thermal Radiation Based Direct Reactor Auxiliary Cooling System

One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The decay heat first is transferred to the core barrel by conduction and radiation, and then to the reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface area). When the relative decay heat removal capability decreases, the peak fuel temperature increases, even close to the design limit. Annular core designs with inner graphite reflector can mitigate this effect; therefore can further increase the reactor power. Another way to increase the reactor power is to increase power density. However, the reactor power is also limited by the decay heat removal capability. Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environment side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions between the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very effective in removing decay heat. By removing the limit on the decay heat removal capability due to the limited available surface area as in a RVACS, the reactor power and power density can be significantly increased, without losing the passive heat removal feature. This paper will introduce the concept of using DRACS to enhance VHTR passive safety and economics. Three design options will be discussed, depending on the cooling pipe locations. Analysis results from a lumped volume based model and CFD simulations will be presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing VHTR passive safety and economy with thermal radiation based direct reactor auxiliary cooling system

One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The RVACS can be characterized as a surface-based decay heat removal system. It is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to the core volume) and decay heat removal capability (proportional to the vessel surface area). Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environmental side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps or annular regions formed between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions among the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very effective in removing decay heat. By removing the limit on the decay heat removal capability due to the limited available surface area as in a RVACS, the reactor power density and therefore the reactor power can be significantly increased, without losing the passive heat removal feature. This paper introduces the concept of using DRACS to enhance VHTR passive safety and economics. Three design options with different cooling pipe locations are discussed. Analysis results from a lumped volume based model and CFD simulations are presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spark Igniters Fit In Correct Locations Only

Pins create interference if incorrect assembly is attempted. When two different types of spark igniters must be used on same engine simple expedient ensures that each igniter is inserted in correct hole. Damage to engine and consequent failure are thereby avoided. Pins in base of spark igniter allow part to be inserted in any type hole.

Wendland, Fred J.↗

Repairing Voids and Delaminations in Composite Materials

Proposed tool forces adhesive into cracks. After inlet and outlet holes have been drilled to proper depth, alinement pin is inserted in inlet hole. Adhesive fills void or is forced into delamination, expanding delamination slightly to ensure full penetration. Potential applications in repair of fiber-reinforced components, boats, storage tanks, and some automobile bodies.

Ott, D. D.↗

Cutting holes in fabric-faced panels

Tool has 2 carbide inserts that bore clean holes through fibrous material with knifelike slicing action. Cutting edge of insert is curved, with plane inner surface at 30 degree angle to tool axis. Drill press or hand-held drill can be used to hold cutting tool.

Peterson, S. A.↗

Screw-Thread Inserts As Temporary Flow Restrictors

Coil-spring screw-thread inserts found useful as temporary flow restrictors. Inserts placed in holes through which flow restricted, effectively reducing cross sections available for flow. Friction alone holds inserts against moderate upstream pressures. Use of coil-spring thread inserts as flow restrictors conceived as inexpensive solution to problem of adjusting flow of oxygen through orifices in faceplate into hydrogen/oxygen combustion chamber. Installation and removal of threaded inserts gentle enough not to deform orifice tubes.

Trimarchi, Paul↗

3D Printed Materials Characterization for Rapid Prototyping and Plant Growth

Space Biology experimentation but their effects during plant growth and sanitation have not been documented. With further testing we can determine how certain 3D printed materials affect our plants. The way we tested germination included laying two pieces of germination paper down with the printed petri dish insert of the various material and 14 seeds of Outrageous lettuce to fit in the holes of the insert. We kept an even moisture in all parts by wrapping the petri dishes in two layers of parafilm tape. This project tests over 15 different materials to document performance during plant growth scenarios. This research will not only help space biology but also citizens who use these materials to understand the potential of leaching and ill effects. 3D printing is a recent generally accessed technology with new materials coming out every day. It is important to understand how materials could impact the way the plants grow, and the safety of the food grown. As we continue testing these materials, we will also test engineering properties like tension and elasticity. We have a microbiology team working on this project as well to test biofilm formation. From the germination tests we have completed we have seen little impact on germination rate of these seeds. However, some parts absorb moisture. An ideal material is one that doesn’t leach chemicals or microplastics, can withstand high tension and compression, and doesn’t promote microbial growth. This work is funded by NASA. M. Gandhi was funded by MAIANSE.

Mily Gandhi↗

Space Suit Portable Life Support System Fastener and Insert Summary, Issues, and Testing Results

Fasteners are included in every assembly on the Exploration External Mobility Unity Portable Life Support System (xEMU PLSS). However, fasteners and inserts have been the cause of many issues seen on the PLSS during development; furthermore, inserts with thermoplastics are not very well understood. The materials used in the PLSS are sometimes softer and lighter weight metals or thermoplastics which require the installation of inserts to improve the interface strength. In addition, space flight requirements call out the need for an additional running/locking torque, so they do not detach in case of failure of the final torque. The xEMU PLSS has experienced various issues with fasteners and inserts, from the bolt binding in an insert or the running torque failing prematurely. A study has been completed to address the running torque life problem. This study compares the insert and locking feature combinations to determine the combination which maximizes life. The study found that using a locking patch with an insert fails after the first installation. Therefore, it is no longer recommended to use a locking patch fastener with an insert for future installments. For the bolt binding issue, inserts have been installed too deep and have caused the bolt to bind near the final threads of the inserts where the hole is not tapped deep enough. Thermoplastics, on the other end, can either use standard helical inserts or heat set inserts. Another study was performed using tangless inserts and heat inserts installed in thermoplastics to quantify the expected pull-out strength for various insert installation parameters (insert type, temperature, and pressure). This paper will review the issues and lessons learned with fasteners on the xEMU PLSS, provide results of a locking feature study, and provide results and recommended installation settings from a heat insert study.

Ryan Ogilvie↗