Search NASA⌕ Search

SEARCH · Search NASA

Results for “home heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Watt Count System

The Watt Count System combines aerospace and computer technology, an engineering systems design approach and the environmental control expertise of a group of engineers who worked on Apollo. First step of the system is a computerized energy consumption analysis based on plans for a new home. Company calculates heating and cooling loads and customizes the most energy efficient system for the particular structure analyzed. A quality control engineer assures that insulation and ducting are installed to specifications. Analysis and design techniques are so accurate that company is able to give homeowner a two-year guarantee that the home's energy consumption will not exceed the kilowatt hour level determined by the computer in step one. In an annual energy performance comparison, a Watt Count home used 45 percent less energy than a conventionally equipped home.

Source record↗

Solar technology in the Federal Republic of Germany

A series of papers dealing with the status of solar research and development in the Federal Republic of Germany are presented at a conference in Greece with the object of promoting international cooperation in solar energy utilization. The reports focus on solar collector designs, solar systems, heat pumps, solar homes, solar cooling and refrigeration, desalination and electric power generation. Numerous examples of systems produced by German manufacturers are illustrated and described, and performance data are presented.

Source record↗

Concentrations and Origins of Atmospheric Lead and Other Trace Species at a Rural Site in Northern China

In this study we analyze the ambient levels of lead and other trace species in the bulk aerosol samples from a rural site approx.70 km ESE of Beijing in spring 2005. Lead (0.28+/-0.24 micro-g/cu m, average +/- standard deviation), along with several pollution \related trace elements, was enriched by over 100 fold relative to the Earth's crust. The ambient lead levels showing large synoptic variations were well-correlated with other anthropogenic pollutants (e.g., CO and SO2). The Unmix receptor model resolved four factors in the aerosol composition data: a biomass burning source, an industrial and coal combustion source, a secondary aerosol source, and a dust source. The first three sources were strongest in weak southerly winds ahead of cold fronts, while the dust source peaked in strong northerly winds behind cold fronts. The second source, primarily representing emissions from industrial processes and relatively small \scale coal burning such as in home and institutional heating, was identified as the main source of ambient lead in this study. Mobile sources might also contribute to this factor, but there was no distinct evidence of emissions due to combustion of leaded gasoline, despite a correlation between lead and CO. Potential source contribution function, calculated from backward trajectories and aerosol composition, further reveals that lead observed in this study was predominantly from the populated and industrialized areas to the south and SW of Xianghe, rather than Beijing to the west. Our results and several recent studies show that the lead levels in suburban areas near big cities in China, although generally lower than those in industrial districts and urban areas, are substantial (near or above 0.15 micro-g/cu m). More extensive studies on airborne lead and its emission sources in China are called for.

Li, Can↗

Application of solar energy; Proceedings of the First Southeastern Conference, Huntsville, Ala., March 24-26, 1975

Topics related to architectural and institutional considerations are discussed along with studies of components and subsystems. Subjects in the area of system design and analysis are also explored. Residential and commercial applications are considered, taking into account hot-water usage in a typical single-family residence, solar heating and cooling of mobile homes, aspects of design and performance in the case of a solar heating system using a reflective pyramid optical condenser, solar heating in a Boston school, a performance analysis of solar service hot water systems, comparative performance analyses of three solar heated and cooled buildings, and the use of solar energy in a soybeam processing operation. Applications related to power generation are also examined, giving attention to solar thermal electric power systems and photovoltaic research. Individual items are announced in this issue.

Wu, S. T.↗

An analytical investigation of the performance of solar collectors as nighttime heat radiators in airconditioning cycles

It was found that if the upper and lower ends of a collector were opened, large free convention currents may be set up between the collector surface and the cover glass(es) which can result in appreciable heat rejection. If the collector is so designed that both plates surfaces are exposed to convection currents when the upper and lower ends of the collector enclosure are opened, the heat rejection rate is 300 watts sq m when the plate is 13 C above ambient. This is sufficient to permit a collector array designed to provide 100 percent of the heating needs of a home to reject the accumulated daily air conditioning load during the course of a summer night. This also permits the overall energy requirements for cooling to be reduced by at least 15 percent and shift the load on the utility entirely to the nighttime hours.

Jones, C. B.↗

Improved Regenerative Sorbent-Compressor Refrigerator

Conceptual regenerative sorbent-compressor refrigerator attains regeneration efficiency and, therefore, overall power efficiency and performance greater than conventional refrigerators. Includes two fluid loops. In one, CH2FCF3 (R134a) ciculates by physical adsorption and desorption in four activated-charcoal sorption compressors. In other, liquid or gas coolant circulated by pump. Wave of regenerative heating and cooling propagates cyclically like peristatic wave among sorption compressors and associated heat exchangers. Powered by electricity, oil, gas, solar heat, or waste heat. Used as air conditioners, refrigerators, and heat pumps in industrial, home, and automotive applications.

Jones, Jack A.↗

Solar Hot Water Heater

The solar panels pictured below, mounted on a Moscow, Idaho home, are part of a domestic hot water heating system capable of providing up to 100 percent of home or small business hot water needs. Produced by Lennox Industries Inc., Marshalltown, Iowa, the panels are commercial versions of a collector co-developed by NASA. In an effort to conserve energy, NASA has installed solar collectors at a number of its own facilities and is conducting research to develop the most efficient systems. Lewis Research Center teamed with Honeywell Inc., Minneapolis, Minnesota to develop the flat plate collector shown. Key to the collector's efficiency is black chrome coating on the plate developed for use on spacecraft solar cells, the coating prevents sun heat from "reradiating," or escaping outward. The design proved the most effective heat absorber among 23 different types of collectors evaluated in a Lewis test program. The Lennox solar domestic hot water heating system has three main components: the array of collectors, a "solar module" (blue unit pictured) and a conventional water heater. A fluid-ethylene glycol and water-is circulated through the collectors to absorb solar heat. The fluid is then piped to a double-walled jacket around a water tank within the solar module.

Source record↗

Wind power systems for individual applications

A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.

Clews, H. M.↗

Aerial thermal scanner data for monitoring rooftop temperatures

Four Nebraska communities and one South Dakota community were surveyed. Thermal scanner data were converted to a film format and the resultant imagery was successfully employed to monitor rooftop temperatures. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorkland, J.↗

A report on the use of thermal scanner data in an operational program for monitoring apparent rooftop temperatures

CENGAS, a division of Central Telephone and Utilities Corporation in cooperation with the Remote Sensing Institute, South Dakota State University, is using airborne thermal scanner data to monitor relative rooftop temperatures. Four Nebraska communities and one South Dakota community were surveyed by the Remote Sensing Institute for CENGAS. Thermal scanner data were converted to a film format and the resultant imagery has been successfully employed by CENGAS. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorklund, J.↗

Aging Will Amplify the Heat-Related Mortality Risk Under a Changing Climate: Projection for the Elderly in Beijing, China

An aging population could substantially enhance the burden of heat-related health risks in a warming climate because of their higher susceptibility to extreme heat health effects. Here, we project heatrelated mortality for adults 65 years and older in Beijing China across 31 downscaled climate models and 2 representative concentration pathways (RCPs) in the 2020s, 2050s, and 2080s. Under a scenario of medium population and RCP8.5, by the 2080s, Beijing is projected to experience 14,401 heat-related deaths per year for elderly individuals, which is a 264.9% increase compared with the 1980s. These impacts could be moderated through adaptation. In the 2080s, even with the 30% and 50% adaptation rate assumed in our study, the increase in heat-related death is approximately 7.4 times and 1.3 times larger than in the 1980s respectively under a scenario of high population and RCP8.5. These findings could assist countries in establishing public health intervention policies for the dual problems of climate change and aging population. Examples could include ensuring facilities with large elderly populations are protected from extreme heat (for example through back-up power supplies and/or passive cooling) and using databases and community networks to ensure the home-bound elderly are safe during extreme heat events.

age factor↗

Home Insulation

Under the Guaranteed Watt Savers (GWS) system, plans for a new home are computer analyzed for anticipated heat loss and gain. Specifications are specifically designed for each structure and a Smart- House Radiant Barrier is installed. Designed to reflect away 95% of the Sun's radiant energy, the radiant barrier is an adaptation of an aluminum shield used on Apollo spacecraft. On completion of a home, technicians using a machine, check for air tightness, by creating a vacuum in the house and computer calculations that measure the amount of air exchanged. A guarantee that only the specified number kilowatt hours will be used is then provided.

Source record↗

Installation package - home solar heater

Installation of commerical solar-heating system at two story, three bedroom house in New Hampshire is described in 65 page report. System collectors are integrated part of building replacing conventional roofing or siding. Report also includes general description of system, its operation and guidelines, orientation and references.

Source record↗

Foam For Filtering

Like nature's honeycomb, foam is a structure of many-sided cells, apparently solid but actually only three percent material and 97 percent air. Foam is made by a heat-producing chemical reaction which expands a plastic material in a manner somewhat akin to the heat-induced rising of a loaf of bread. The resulting structure of interconnected cells is flexible yet strong and extremely versatile in applicati6n. Foam can, for example, be a sound absorber in one form, while in another it allows sound to pass through it. It can be a very soft powder puff material and at the same time a highly abrasive scrubber. A sampling of foam uses includes stereo speaker grilles, applying postage meter ink, filtering lawnmower carburetor air; deadening noise in trucks and tractors, applying cosmetics, releasing fabric softener and antistatic agents in home clothes dryers, painting, filtering factory heating and ventilating systems, shining shoes, polishing cars, sponge-mopping floors, acting as pre-operative surgical scrubbers-the list is virtually limitless. The process by which foam is made produces "windows," thin plastic membranes connecting the cell walls. Windowed foam is used in many applications but for certain others-filtering, for example-it is desirable to have a completely open network. Scott Paper Company's Foam Division, Chester, Pennsylvania, improved a patented method of "removing the windows," to create an open structure that affords special utility in filtering applications. NASA technology contributed to Scott's improvement.

Source record↗

Milwaukee Urban Development: Assessing Climate Vulnerability through the InVEST Model on Urban Cooling in Milwaukee Using NASA Earth Observations

Milwaukee’s neighborhoods experience increased social, health, and ecological stress from the Urban Heat Island (UHI) effect due to changing land cover and climate. Extreme urban heat disproportionately affects Black and Latine communities due to systematic disinvestment in infrastructure and lack of resources to cope with heat. Our partner, Groundwork Milwaukee, supports Environmental Justice organizing around urban heat in historically redlined neighborhoods. This study explores heat mitigation in Metcalfe Park, one such neighborhood that is a focus area for our partner, as well as across the city and county of Milwaukee. Our team utilized the Natural Capital Project’s Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) Model for urban cooling to model heat mitigation scenarios for Milwaukee in support of Groundwork’s climate resilience and heat mitigation work. The data inputs used in our analysis were Land Use Land Cover (LULC), evapotranspiration, and surface temperature derived from NASA Earth observations, as well as a biophysical table containing land cover class attributes. We developed a heat vulnerability index from American Community Survey datasets and satellite imagery to identify areas in most need of heat mitigation intervention. We found that central and northwest city areas, home to a majority of Milwaukee’s Black and Latine population, have low heat mitigation and high vulnerability to heat impacts compared to the rest of the county. We also found that tree canopy increases across scales are effective in promoting heat mitigation. Our results and end products will bolster the efforts of our partners to make decisions on heat mitigation strategies, build community resilience, and reverse legacies of environmental racism in the face of extreme heat and climate change.

urban heat island↗

Wichita Climate: Using Satellite Data to Identify Neighborhoods Vulnerable to Extreme Heat for Equitable Climate Mitigation and Planning

Wichita, Kansas is facing a host of climate threats, one being extreme heat that is manifested through the urban heat island (UHI) effect. The uneven distribution of heat risk in Wichita across socioeconomic status is an environmental justice issue. We worked with the City of Wichita to map heat exposure, tree canopy, and heat risk in order to support the City's climate resilience initiatives. To visualize heat exposure, we quantified and mapped average summer heat from 2013–2021 using Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) Land Surface Temperature (LST) and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) night-time LST. To understand tree canopy cover gaps, we created a tree canopy map using 2021 PlanetScope imagery, which identified 20% more trees than the US Geological Survey’s (USGS) National Land Cover Database (NLCD) tree canopy coverage estimates for Wichita. To characterize high risk areas, we used socioeconomic census data and existing social vulnerability indices, highlighting populations that were exposed and vulnerable to extreme heat. The spatial analyses demonstrated that heat exposure is concentrated in the city center and southwest Wichita, areas that are also low in tree canopy coverage. The three census block groups and 17 census tracts with the highest heat risk primarily circle the city center, in areas home to more socially vulnerable populations and near enough to the dense urban center to feel significant urban heat island effects.

Brooke Laird↗

Wichita Climate: Using Satellite Data to Identify Neighborhoods Vulnerable to Extreme Heat for Equitable Climate Mitigation and Planning

Wichita, Kansas is facing a host of climate threats, one being extreme heat that is manifested through the urban heat island (UHI) effect. The uneven distribution of heat risk in Wichita across socioeconomic status is an environmental justice issue. We worked with the City of Wichita to map heat exposure, tree canopy, and heat risk in order to support the City's climate resilience initiatives. To visualize heat exposure, we quantified and mapped average summer heat from 2013–2021 using Landsat 8 Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) Land Surface Temperature (LST) and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) night-time LST. To understand tree canopy cover gaps, we created a tree canopy map using 2021 PlanetScope imagery, which identified 20% more trees than the US Geological Survey’s (USGS) National Land Cover Database (NLCD) tree canopy coverage estimates for Wichita. To characterize high risk areas, we used socioeconomic census data and existing social vulnerability indices, highlighting populations that were exposed and vulnerable to extreme heat. The spatial analyses demonstrated that heat exposure is concentrated in the city center and southwest Wichita, areas that are also low in tree canopy coverage. The three census block groups and 17 census tracts with the highest heat risk primarily circle the city center, in areas home to more socially vulnerable populations and near enough to the dense urban center to feel significant urban heat island effects.

Brooke Laird↗

Residential solar-heating system

Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

Source record↗