Search NASA⌕ Search

SEARCH · Search NASA

Results for “hybrid architectures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The BREKTRIA 500 – A Breakthrough in Technology and Power Density for an Advanced 500kW Utility-Scale String Inverter (Final Technical Report)

The primary goal of this development project, planned to be 36 months in duration, was to create a 500kW utility-scale string inverter, demonstrating an advanced hybrid architecture that would achieve unprecedented high power density, and bring the inverter to the stage of production readiness. Specific key objectives for the 500kW utility-scale string inverter were: Create a 500kW 3-phase 600Vac inverter that was similar in overall size to the existing 250kW string inverters in the market, thereby demonstrating dramatically increased power density; Achieve a cost of goods, including all manufacturing-related costs and overheads, at or below 2.5¢/Wac ($12,500); Demonstrate full-power operation at a 45-50C ambient temperature with no power de-rating; Accommodate a PV array DC input of up to 1MWdc, aka a DC/AC Ratio of 2.0; Demonstrate peak efficiency greater than 99% at any operating dc voltage, and a CEC weighted average efficiency greater than or equal to 98.5%. The motivation for this project was to leapfrog the competition by creating the world’s most powerful string inverter, utilizing an innovative topology and achieving a step change increase in power density. Achieving the goals of the project would have enabled Yaskawa Solectria Solar to demonstrate its technology leadership, manufacture the utility-scale string inverter in the company’s facilities in Illinois, and bring to the market a highly-differentiated and compelling product to help the company grow its share in the large and growing utility market segment. During the course of this project, BREK Electronics’ hybrid architecture inverter was taken from an early-stage 125kW prototype, to a more mature and successfully demonstrated power stage at twice the power. Two 250kW power stages were planned to build the 500kW inverter. Significant progress was made in the inverter controls, achieving a clean AC sinewave and closed-loop operation into the grid, and improved efficiency by control of the high-speed switching. Further, the updated 250kW power stage was on track to achieve full power operation at an ambient temperature of 50C. At the time of the project’s closure in September 2022, global semiconductor supply remained limited, with shortages creating dramatic swings in both availability and price. Given this situation, our ability to predict cost-of-goods two years out with any accuracy or confidence was limited. As a result, the probability of attaining the target cost of 2.5¢/Wac for the 500kW inverter remained uncertain at the closure of the project. This project successfully demonstrated the potential for the advanced hybrid architecture inverter that emerged from a decade of university research on Si IGBTs and SiC mosfets, leading to this unique inverter topology. The team has taken the first steps toward an evolutionary advancement in inverter technology that remains to be fully realized.

14 SOLAR ENERGY↗

Electric and Hydraulic Propel Torque Modulation for a Compact Track Loader With the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) has previously been proposed for off-highway vehicles to reap the efficiency and controllability benefits of electrification without needing very large electric motors. This is achieved with the use of a set of selectable common pressure rails to transmit the majority of power and small electric motors to modulate that power. Previous work has shown significant energy savings for the work circuits of a variety of machines. In this paper, the energy saving potential of HHEA for the propel circuit of a compact track loader is studied. The ports of the track hydraulic motors are selectably connected to the common pressure rails, and instead of using the electric assist motors to buck/boost pressure, as in HHEA for linear actuators, small electric assist motors are used to add/subtract torque directly. The interplay between the torque limits of the electric motors and the ability of the hydraulic motor to vary displacements is studied, along with the effect these factors have on energy saving potential. It is found that the ability to vary the displacement of the hydraulic motor allows for: more efficient electric motor operating conditions, reduced electric torque requirement, and reduced pressure rail switching events. All three of these advantages can be achieved at once using variable displacements; but trade-offs exist between these advantages (i.e. improved efficiency can be achieved at the expense of a larger electric torque requirement). Overall, the HHEA can reduce energy consumption by ∼ 36% compared to the stock machine, depending on the hydraulic motor’s ability to vary displacements, and assuming the electric motor torque is limited to 20% of that required in a direct electrification scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery-ultracapacitor hybrid energy storage system architecture for mild-hybrid power systems

A mild-hybrid energy storage system architecture is provided, comprising: a battery; an ultracapacitor connected in parallel with the battery; a passive battery pre-charge circuit connected between a terminal of the battery and a DC bus; a battery main contactor connected in parallel with the battery pre-charge circuit between the terminal of the battery and the DC bus; a passive ultracapacitor pre-charge circuit connected between a terminal of the ultracapacitor and the DC bus; an ultracapacitor main contactor connected in parallel with the ultracapacitor pre-charge circuit between the terminal of the ultracapacitor and the DC bus; and a control module configured to independently control operation of the battery pre-charge circuit, the battery main contactor, the ultracapacitor pre-charge circuit and the ultracapacitor main contactor.

Varigonda, Subbarao↗

Human-in-the-Loop Motion Control of a Two-DOF Hydraulic Backhoe Powered by the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic-Electric Architecture (HHEA) combines the respective power density and control advantages of hydraulic and electric actuation to save energy for off-road vehicles. It uses a set of selectable common pressure rails to transmit the majority of power and electric actuation to modulate that power. As it is critical that off-road vehicles can perform tasks dexterously and exactly as commanded by the operator, the switchings between discrete pressure rails pose a potential challenge for smooth and precise motion. A control strategy consisting of a backstepping nominal control and least norm transition control has previously been developed to address this issue. It has been tested on 1 degree of freedom (DOF) testbeds where known trajectories were able to be tracked precisely. This paper presents the implementation of the HHEA motion control strategy on a 2-DOF backhoe operated by a human operator via a 2-DOF joystick. Unlike previous studies, the duty cycle is unknown beforehand and the decision to change pressure rails is taken in real-time. The efficacy of the motion control strategy has been validated experimentally. Several strategies to improve the user interface: control in workspace coordinates, pressure feedback, and velocity field-based task specification, have also been implemented and demonstrated to make operating the multiple DOF, HHEA actuated machine more intuitive to novice operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Real-Time Pressure Rail Selection Algorithms for the Hybrid Hydraulic Electric Architecture: Case Study on a Track Loader

Abstract The hybrid hydraulic electric architecture (HHEA) seeks to combine the high power/torque/force density of hydraulics with the efficiency of electric machines. A set of common pressure rails is used to provide a majority of the power and this power is modulated by small electric machines to provide precise control for the operator. The HHEA has been studied in previous work using off-line dynamic programming optimization to determine energy efficient pressure rail selections, but this approach requires drive cycle information apriori. A Lagrange multiplier method has also been investigated where a set of gains (Lagrange multipliers) are optimized off-line with the idea the these gains, once determined, could be used for real-time operation. In this work, three new real-time pressure rail selection algorithms that do not require future drive cycle information are investigated; greedy, torque minimizing, and thresholding. The greedy control is found to only use 1% more energy than the globally optimal dynamic programming solution; but a model of energy loss is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interpretable Models for Workflow Differentiation in High-Performance Scientific Networks

Scientific workflows in high-performance networks spawn hundreds of interdependent flows that must be managed collectively—yet existing network classifiers treat each flow in isolation, leading to fragmented QoS decisions and missed interflow patterns. We present a novel traffic classification solution that operates at the workflow level, distinguishing entire filetransfer operations from streaming analytics by capturing how concurrent flows interact and burst together. We introduce a workflow identification window (WIW) that ingests raw packet headers from parallel flows into unified tensors, preserving the spatial-temporal patterns that differentiate scientific workflows. This approach achieves 98.7% accuracy using CNN, LSTM, and hybrid architectures, while maintaining 84% accuracy on production traffic collected a week later—demonstrating robustness to temporal drift. By integrating SHAP and GradCAM explainability, we reveal that early-packet timing patterns and cross-flow correlations drive classification decisions, providing operators with interpretable insights. Our system enables coherent workflow-level QoS enforcement and dynamic bandwidth allocation in scientific networks, eliminating manual per-flow configuration while maintaining classification latency at millisecond level.

Giannakou, Anna [LBL, Berkeley]↗

Optimizing the fuel efficiency of an opposed piston engine for electric power generation

This paper investigates the optimal crankshaft motion for an opposed piston (OP) engine in a novel hybrid architecture to maximize fuel efficiency. The OP engine was selected for this work due to its inherent thermodynamic benefits and the balanced nature of the engine which can achieve downsizing through reducing the number of cylinders rather than the individual cylinder volume. The typical geartrain required on an OP engine was exchanged for two electric motors, reducing friction loss and decoupling the crankshafts. Using the motors to control the crankshaft motion profiles, this architecture introduces capabilities to dynamically vary compression ratio, combustion volume, and scavenging dynamics. To leverage these opportunities, an optimization scheme was developed utilizing nonlinear optimization of a 0-D model to compute the crankshaft motion profile that maximizes the work generated by the system. This optimization was then iteratively coupled with a high fidelity model which supplies the cylinder flow boundary conditions. This iterative approach reduces the model complexity used in the optimal control problem (OCP) while capturing the gas exchange dynamics critical to the 2-stroke cycle of the OP engine. By using the rate of change of motor torque as the input to the OCP, the torque fluctuation in a single cycle can be limited to ensure tracking feasibility. The results show crankshaft velocity slows during the compression stroke and conversely accelerates during the expansion stroke, reducing the peak motor torque required for control and thus reducing the motor losses. The extended residence time at top dead center, however, leads to an increase in heat transfer, illustrating the trade-off between the work extraction efficiency and the indicated engine efficiency.

Engineering↗

Hybrid Network Architectures for the Next Generation NAS

To meet the needs of the 21st Century NAS, an integrated, network-centric infrastructure is essential that is characterized by secure, high bandwidth, digital communication systems that support precision navigation capable of reducing position errors for all aircraft to within a few meters. This system will also require precision surveillance systems capable of accurately locating all aircraft, and automatically detecting any deviations from an approved path within seconds and be able to deliver high resolution weather forecasts - critical to create 4- dimensional (space and time) profiles for up to 6 hours for all atmospheric conditions affecting aviation, including wake vortices. The 21st Century NAS will be characterized by highly accurate digital data bases depicting terrain, obstacle, and airport information no matter what visibility conditions exist. This research task will be to perform a high-level requirements analysis of the applications, information and services required by the next generation National Airspace System. The investigation and analysis is expected to lead to the development and design of several national network-centric communications architectures that would be capable of supporting the Next Generation NAS.

Madubata, Christian↗

Integrated Hybrid System Architecture for Risk Analysis

A conceptual design has been announced of an expert-system computer program, and the development of a prototype of the program, intended for use as a project-management tool. The program integrates schedule and risk data for the purpose of determining the schedule applications of safety risks and, somewhat conversely, the effects of changes in schedules on changes on safety. It is noted that the design has been delivered to a NASA client and that it is planned to disclose the design in a conference presentation.

Moynihan, Gary P.↗

Hybrid VLSI/QCA Architecture for Computing FFTs

A data-processor architecture that would incorporate elements of both conventional very-large-scale integrated (VLSI) circuitry and quantum-dot cellular automata (QCA) has been proposed to enable the highly parallel and systolic computation of fast Fourier transforms (FFTs). The proposed circuit would complement the QCA-based circuits described in several prior NASA Tech Briefs articles, namely Implementing Permutation Matrices by Use of Quantum Dots (NPO-20801), Vol. 25, No. 10 (October 2001), page 42; Compact Interconnection Networks Based on Quantum Dots (NPO-20855) Vol. 27, No. 1 (January 2003), page 32; and Bit-Serial Adder Based on Quantum Dots (NPO-20869), Vol. 27, No. 1 (January 2003), page 35. The cited prior articles described the limitations of very-large-scale integrated (VLSI) circuitry and the major potential advantage afforded by QCA. To recapitulate: In a VLSI circuit, signal paths that are required not to interact with each other must not cross in the same plane. In contrast, for reasons too complex to describe in the limited space available for this article, suitably designed and operated QCAbased signal paths that are required not to interact with each other can nevertheless be allowed to cross each other in the same plane without adverse effect. In principle, this characteristic could be exploited to design compact, coplanar, simple (relative to VLSI) QCA-based networks to implement complex, advanced interconnection schemes.

Fijany, Amir↗

Multidisciplinary Systems Analysis of a Six Passenger Quadrotor Urban Air Mobility Vehicle Powertrain

There is a high degree of research interest in the design space for electric vertical takeoff and landing (eVTOL) vehicles, because these vehicles are seen as key enablers for urban air mobility (UAM). This work further explores the eVTOL design space, by presenting analysis of a six-passenger eVTOL quadrotor powertrain, with integrated power, propulsion, and thermal management systems modeled using the Numerical Propulsion System Simulation (NPSS) and the NPSS Power System Library. Four architectures are modeled at the same design point and compared over a design mission. Results from an architecture comparison study show that a hybrid architecture performs best in terms of cruise range, however, the hybrid needs batteries with high specific energy and specific power in order to obtain a benefit vs turboelectric architectures. Sensitivity studies are conducted to show correlations between component parameters and system metrics. This data provides useful indicators for further technological improvement. Lastly, an initial TMS model is presented, and sensitivity studies on TMS design parameters are presented as well, to show high level TMS design trends.

evtol↗

Multidisciplinary Systems Analysis of a Six Passenger Quadrotor Urban Air Mobility Vehicle Powertrain

There is a high degree of research interest in the design space for electric vertical takeoff and landing (eVTOL) vehicles, because these vehicles are seen as key enablers for urban air mobility (UAM). This work further explores the eVTOL design space, by presenting analysis of a six-passenger eVTOL quadrotor powertrain, with integrated power, propulsion, and thermal management systems modeled using the Numerical Propulsion System Simulation (NPSS) and the NPSS Power System Library. Four architectures are modeled at the same design point and compared over a design mission. Results from an architecture comparison study show that a hybrid architecture performs best in terms of cruise range, however, the hybrid needs batteries with high specific energy and specific power in order to obtain a benefit vs turboelectric architectures. Sensitivity studies are conducted to show correlations between component parameters and system metrics. This data provides useful indicators for further technological improvement. Lastly, an initial TMS model is presented, and sensitivity studies on TMS design parameters are presented as well, to show high level TMS design trends.

electrified propulsion↗

Incorporating Valve Switching Losses Into a Static Optimal Control Algorithm for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) has, in recent years, been proposed as an energy efficient alternative to conventional load-sensing architectures in mobile machines such as excavators and wheel-loaders. HHEA leverages the advantages of hydraulic power and electric power to eliminate throttling valves while also improving the energy and control performance of the system. The architecture utilizes a set of common pressure rails to provide a majority of power and and a small electric motor driven pump to modulate this power to meet the exact demand. Previous work has developed a computationally efficient Lagrange Multiplier approach for determining the optimal pressure rail selections that minimizes the energy losses in the system. The static model used considers only the energy use for each pressure rail selection but not the losses associated with the valves during the transition. This paper presents an approach to include the switching losses in the model and in the optimization procedure. To capture the switching losses, switching events between different rails and at various input and output flow rates were simulated with consideration of valve spool dynamics. A parameterized model that summarizes the losses is then obtained, allowing switching losses to be added to the previous energy analysis. The performance of the switching loss model was compared with reference data obtained from a high-fidelity simulation model. To incorporate the switching losses into optimal control algorithm, an efficient dynamic programming approach that prevents frequent switching is adopted in place of the Lagrange multiplier approach. The overall effect of switching losses on the energy consumption and optimal control decisions is presented. In general, switching losses contribute to about 9–10% of input energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HIL Testbed and Motion Control Strategy for the Hybrid Hydraulic-Electric Architecture (HHEA)

The Hybrid Hydraulic-Electric Architecture (HHEA) was proposed in recent years to increase system efficiency of high power mobile machines and to reap the benefits of electrification without the need for large electric machines. It uses a set of common pressure rails to provide the majority of power hydraulically and small electric motors to modulate that power for precise control. This paper presents the development of a Hardware-in-the-loop (HIL) test-bed for testing motion control strategies for the HHEA. Precise motion control is important for off-road vehicles whose utility requires the machine being dexterous and performing tasks exactly as commanded. Motion control for the HHEA is challenging due to its intrinsic use of discrete pressure rail switches to minimize system efficiency or to keep the system within the torque capabilities of the electric motor. The motion control strategy utilizes two different controllers: a nominal passivity based back-stepping controller used in between pressure rail switches and a transition controller used to handle the event of a pressure rail switch. In this paper, the performance of the nominal control under various nominal and rail switching scenarios is experimentally evaluated on the HIL testbed.

33 ADVANCED PROPULSION SYSTEMS↗

Accumulator Sizing for the Hybrid Hydraulic Electric Architecture (HHEA) Using Dynamic Programming

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) is an approach to electrifying and improving that does not require very large electric machines. The majority power is provided hydraulically via a set of common pressure rails while small electric machines are used to modulate that power to meet exact demand. Each common pressure rail has an accumulator, which keeps the pressure of each rail near constant as long as the volume in the accumulator does not change much. A main pump adds or removes fluid from each accumulator as needed to reduce volume changes in the accumulators. It is the operation of this main pump which is investigated here. In previous analysis it was assumed that the size of the accumulators was large enough to account for any difference in fluid volume without significantly changing the pressure. In this paper, the required accumulator sizes are studied using a dynamic programming approach. At each time step the inlet and outlet of the main pump could be connected to any of the common pressure rails. These decisions for the main pump were optimized to minimize the required accumulator size. Case studies are conducted using drive cycles from a 22-ton excavator, a 20-ton wheel loader and a 5-ton excavator. The machines could be operated with total accumulator sizes of less than 20, 10, and 5 liters respectively. Required accumulator size was found to vary with pump flow rate, the frequency at which the pump/motor was able to change operating conditions, the tolerance level of pressure deviation and the accumulator’s polytropic index.

24 POWER TRANSMISSION AND DISTRIBUTION↗