Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydraulic turbines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Grid and Wind Transient Ride Through Assessment of Type-5 Synchronous Wind Turbine

The integration of the inverter-based renewable energy resources is increasing and replacing conventional synchronous generators in the evolving bulk power system (BPS), impacting the system inertia along the way. Also, the limited over-current capability of power electronic converters continues to deteriorate the grid strength of the evolving power systems. Type-5 wind turbines have the potential to mitigate these problems because this configuration interfaces with the grid through a synchronous generator; hence, its operation and consequent grid impacts might mimic the conventional synchronous generator. The drivetrain of this type of turbines, however, is different from the more common Type-3 and Type-4 turbines. A hydraulic torque converter and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine drivetrain, to isolate the wind speed variations at the wind turbine rotor from the grid connected generator side. This supports the synchronous operation of the generator. However, high fidelity models of Type-5 wind turbine drivetrain including these core components are not openly and widely available for grid integration and transient stability studies. Moreover, Type-5 turbines are not commonly deployed and hence its power generation and frequency stability characteristics are not widely publicized. This hinders appropriate assessment of Type-5 wind power plant's contribution to bulk grid resilience. This work provides transient stability assessment of a standalone Type-5 wind turbine. Normal operation and grid transient studies are performed to see the step load change and wind speed disturbance impacts on the Type-5 drivetrain and generation dispatch. Preliminary results show that Type-5 wind turbines can support load changes of between 0.6 p.u to 1.15 p.u. Beyond this point, the synchronization of the generator starts to deviate from its set point.

17 - WIND ENERGY↗

Reinforcement Learning Control for Enhancing Marine Hydrokinetic Turbine Energy Generation

This paper proposes a reinforcement learning-based method to maximize power generation for a direct-drive marine hydrokinetic turbine. A high levelized cost of energy (LCOE) is preventative in the widespread adoption of many marine energy conversion technologies. A straightforward way to reduce LCOE is to increase conversion efficiency and ensure maximum energy generation. The proposed method utilizes a damping control methodology, varying applied generator torque via a linear relationship between the applied damping coefficient and rotor speed. A state-action-reward-state-action (SARSA) algorithm has been used to learn the optimal control action for a given flow velocity. The proposed SARSA methodology uses Gaussian radial basis functions to create a three-dimensional surface to estimate the relationship between damping coefficient, incoming flow velocity, and coefficient of power (C p ). Here, the SARSA algorithm was compared against a baseline optimal tip speed ratio controller over a year-long flow velocity case profile while considering the effects of biofouling on the turbine system, where the proposed RL method generated 0.92% more energy than the baseline.

Damp↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

Quantifying Risk in an Uncertain Future: The Evolution of Resource Adequacy

As our power grids transition toward a decarbonized energy mix, ensuring reliability and provision of grid services remains paramount. The power system has always been heavily influenced by the weather - extreme temperatures determine the timing of peak demand, winter cold snaps can limit natural gas supply, gas turbine reliability and output are affected by ambient conditions, and hydro output varies seasonally and annually. However, as the grid increasingly relies on variable renewable energy (VRE), like wind and solar, the attention to reliability and weather conditions is increasingly important. The implications of changing reliability are large. The Electric Reliability Council of Texas (ERCOT) rolling blackouts from earlier this year impacted millions of people across the state and could be seen from space (Figure 1).

hydraulic turbines↗

Advanced Performance Hydraulic Wind Energy

The Jet Propulsion Laboratory, California Institute of Technology, has developed a novel advanced hydraulic wind energy design, which has up to 23% performance improvement over conventional wind turbine and conventional hydraulic wind energy systems with 5 m/sec winds. It also has significant cost advantages with levelized costs equal to coal (after carbon tax rebate). The design is equally applicable to tidal energy systems and has passed preliminary laboratory proof-of-performance tests, as funded by the Department of Energy.

tides↗

Update on Model Specification Development of Ternary Pumped Storage Technologies [Slides]

T-PSH is an innovative structure of C-PSH that features two turbines, one for pumping and one for generation, replacing the single turbine in C-PSH. These turbines are housed in separate chambers, with an additional set of penstocks connecting the pump turbine to the hydraulic system. This structure enables T-PSH to operate in an HSC mode, allowing for simultaneous pumping and generation, which provides greater operational flexibility compared to C-PSH. To model T-PSH's HSC mode, a user defined turbine and governor system model is required, including the shared penstock model and additional pump turbine model. This specification will focus on the details of the user-defined turbine and governor model, which leverages the HYGOV model.

16 TIDAL AND WAVE POWER↗

Hydropower Biological Evaluation Toolset (HBET) Version 3.0: User Guide

The Hydropower Biological Evaluation Tools (HBET) software package, developed by Pacific Northwest National Laboratory (PNNL), is designed to assemble, organize, and process data collected by Sensor Fish and live fish. HBET enable users to characterize the hydraulic conditions of hydropower structures and estimate fish injury and mortality rates from various stressors. Future updates of the software may support other technologies, such as bead tracking in physical models and computational fluid dynamics. The HBET program can be customized to analyze different hydraulic applications, including turbines, spillways, weirs, pumped storage, and other user-defined functions, and therefore, help researchers, turbine designers, hydropower operators, and regulators better evaluate hydropower structures regarding their environmental sustainability and cost-effectiveness. Added content to the user guide about the new feature for predicting absolute injury rates.

13 HYDRO ENERGY↗

Hydropower Energy Storage Capacity (HESC) Dataset

The Hydropower Energy Storage Capacity (HESC) Dataset catalogs characteristics that are relevant to evaluating reservoir storage and estimates of energy storage capacity based on varying levels of detail. Hydropower dams and reservoirs were included based on information from the National Inventory of Dams (NID; USACE, 2021) and Global Reservoir and Dam (GRanD v1.3) and Existing Hydropower Assets datasets. These data provide a foundation for understanding available resources at existing hydropower facilities and their potential to provide storage of energy and more flexible generation. Estimates of energy storage capacity include: • Level 1 – nominal energy storage capacity based on maximum storage capacities and hydraulic head • Level 2 – nominal energy storage capacity based on historical models or observations of reservoir volume and hydraulic head. These estimates are provided based on capacity from the entire historical period as well as monthly values. • Level 3 – modeled energy generation based on volume-elevation relationships, historical storage, observed/modeled inflows, and hydraulic capacity of turbines and calculated both as overall and on a monthly basis. • Level 4 – modeled energy generation incorporating information from Level 3 and operational constraints. For facilities where installed capacity is known, there are also estimates for discharge duration (the length of time when a facility could provide generation at a given capacity).

13 HYDRO ENERGY↗

The Solid Rocket Booster Auxiliary Power Unit: Meeting the Challenge

The thrust vector control systems of the solid rocket boosters are turbine-powered, electrically controlled hydraulic systems which function through hydraulic actuators to gimbal the nozzles of the solid rocket boosters and provide vehicle steering for the Space Shuttle. Turbine power for the thrust vector control systems is provided through hydrazine fueled auxiliary power units which drive the hydraulic pumps. The solid rocket booster auxiliary power unit resulted from trade studies which indicated significant advantages would result if an existing engine could be found to meet the program goal of 20 missions reusability and adapted to meet the seawater environments associated with ocean landings. During its maturation, the auxiliary power unit underwent many design iterations and provided its flight worthiness through full qualification programs both as a component and as part of the thrust vector control system. More significant, the auxiliary power unit has successfully completed six Shuttle missions.

Hughes, R. W.↗

Causal Factors and Adverse Events of Aviation Accidents and Incidents Related to Integrated Vehicle Health Management

Causal factors in aviation accidents and incidents related to system/component failure/malfunction (SCFM) were examined for Federal Aviation Regulation Parts 121 and 135 operations to establish future requirements for the NASA Aviation Safety Program s Integrated Vehicle Health Management (IVHM) Project. Data analyzed includes National Transportation Safety Board (NSTB) accident data (1988 to 2003), Federal Aviation Administration (FAA) incident data (1988 to 2003), and Aviation Safety Reporting System (ASRS) incident data (1993 to 2008). Failure modes and effects analyses were examined to identify possible modes of SCFM. A table of potential adverse conditions was developed to help evaluate IVHM research technologies. Tables present details of specific SCFM for the incidents and accidents. Of the 370 NTSB accidents affected by SCFM, 48 percent involved the engine or fuel system, and 31 percent involved landing gear or hydraulic failure and malfunctions. A total of 35 percent of all SCFM accidents were caused by improper maintenance. Of the 7732 FAA database incidents affected by SCFM, 33 percent involved landing gear or hydraulics, and 33 percent involved the engine and fuel system. The most frequent SCFM found in ASRS were turbine engine, pressurization system, hydraulic main system, flight management system/flight management computer, and engine. Because the IVHM Project does not address maintenance issues, and landing gear and hydraulic systems accidents are usually not fatal, the focus of research should be those SCFMs that occur in the engine/fuel and flight control/structures systems as well as power systems.

Reveley, Mary S.↗

Fish scale-loss caused by simulated hydraulic shear stress

Riverine fishes found within streams impacted by hydropower also often pass through hydropower turbines during annual downstream migrations. During turbine passage events, fish may experience a suite of stressors including rapid pressure changes, impacts from turbine blades, and exposure to hydraulic shear. Scale-loss is often observed in fish collected below dams and hydraulic shear is the most likely cause of this trauma. While exposure to shear may cause other injuries, scale-loss appears to be the most common non-lethal injury observed to date. We sought to quantify how hydraulic shear may cause scale-loss in rainbow trout, gizzard shad, and hybrid striped bass by precisely controlling the exposure level (velocity) and duration (seconds) of a water jet. We targeted the same area for all three species found between the operculum and dorsal fin on the left, lateral surface. Exposure velocities ranged from 0 (controls) to 11.0 meters/second but fish were only exposed to the water jet for 1.5 seconds. A 0.2 milligram/milliliter solution of fluorescein was used to stain the areas of scale-loss by submerging each fish in this solution for at least 6 minutes. Fluorescein was used because it interacts with epithelial tissue that has been damaged and it fluoresces under ultraviolet lighting. Fish were photographed under short- and longwave ultraviolet lighting in a dark chamber to capture fluorescence. Fish photographs were analyzed using ImageJ and the proportion of descaled area was estimated for each fish within a 35 by 35-millimeter square. In general, these data highlight how exposure to hydraulic shear may lead to significant levels of descaling in riverine fishes.

13 HYDRO ENERGY↗

Space Shuttle Orbiter auxiliary power unit status

An overview of the United States Space Shuttle Orbiter APU, which provides power to the Orbiter vehicle hydraulic system, is presented. Three complete APU systems, each with its own separate fuel system, supply power to three dedicated hydraulic systems. These in turn provide power to all Orbiter vehicle critical flight functions including launch, orbit, reentry, and landing. The basic APU logic diagram is presented. The APU includes a hydrazine-powered turbine that drives a hydraulic pump and various accessories through a high-speed gearbox. The APU also features a sophisticated thermal management system designed to ensure safe and reliable operation in the various launch, orbit, reentry, and landing environments.

Reck, M.↗

Safe passage of American Eels through a novel hydropower turbine

Abstract Objective Study the effects of downstream passage through a novel turbine designed for fish safety, the Restoration Hydro Turbine (RHT), on American Eels Anguilla rostrata in a recirculating turbine test facility. Methods A 55‐cm‐diameter RHT was operated under 10 m of hydraulic head and 667 revolutions/min. In total, 131 eels were passed through the turbine and 43 eels were used as experimental controls (length = 33.9–65.5 cm). High‐speed video of passage through the runner region was captured for 89% of turbine‐passed eels, and injury and behavioral effects were recorded immediately before and after passage, as well as after a 48‐h holding period. A subset of 37 eels was additionally examined with X‐ray imaging for internal injuries. Result The 48‐h survival rate for both treatment and control groups was 100%, with no major internal or external injuries present after the holding period. Conclusion This is a substantial improvement over eel survival rates through conventional Kaplan and Francis turbines, which may range from 40% to 95%, and suggests that hydropower turbines designed for safe downstream fish passage could be implemented without major impacts to eels.

59 BASIC BIOLOGICAL SCIENCES↗

A High-Fidelity Model of the Peach Bottom 2 Turbine-Trip Benchmark Using VERA

This work presents a high-fidelity simulation of the Peach Bottom turbine trip (PBTT) benchmark using the Virtual Environment for Reactor Applications (VERA), a multiphysics reactor modeling tool developed by the U.S. Department of Energy’s Consortium for Advanced Simulation of Light Water Reactors energy innovation hub. The PBTT benchmark, based on a 1977 transient event at the end of cycle 2 in a General Electric Type-4 boiling water reactor (BWR), is a critical test case for validating core physics models with thermal feedback during rapid reactivity events. VERA was employed to perform end-to-end, pin-resolved simulations from conditions at the beginning of cycle 1 through the turbine-trip transient, incorporating detailed neutron transport, fuel depletion, and subchannel thermal hydraulics. The simulation reproduced key benchmark observables with high accuracy: the peak power excursion occurred at 0.75 s, matching the scram time and closely aligning with the benchmark average of 0.742 s; the simulated maximum power spike was approximately 7600 MW, which is within 3% of the benchmark average of 7400 MW; and void-collapse dynamics were consistent with benchmark expectations. Reactivity predictions during cycles 1 and 2 remained within 1500 pcm and 400 pcm of criticality, respectively. These results confirm VERA’s ability to model complex coupled neutronic and thermal hydraulic behavior in a BWR turbine-trip transient, which will support its use in future studies of modeling dryout, fuel performance, and uncertainty quantification for transients of this type.

BWR↗

Computational studies of hydraulic stressors for biological performance assessment in a hydropower plant with Kaplan turbine

We report Hydropower is currently one of the preeminent sources of renewable energy in the United States and globally. Hydropower plants also have detrimental impacts on the environment and ecology, including direct impacts to anadromous fish populations. The computational fluid dynamics (CFD) – based Biological Performance Assessment (BioPA) toolset is used for biological evaluations of fish passage through hydropower plants. The hydraulic environment of a hydropower plant was evaluated using CFD coupled with discrete element method (DEM) simulations. The predicted flow field and particle collision rate were validated against the experimental data in a water flume that has an idealized hydroturbine distributor geometry. Flow simulations were conducted to evaluate the hydraulic stressors, such as nadir pressure, fluid shear, runner collision, in a physical scale in a hydropower plant with Kaplan turbine which are responsible for injury and mortality of fish in a downstream migration. The cumulative exposure probability for the nadir pressure and collision with turbine runner was found to decrease with increased discharge rate. The lowest discharge rate shows the higher value of cumulative shear exposure probability. The maximum value of collision velocity increases with increased discharge rate. We offer the conclusions that will help in understanding various hydraulic stressors for biological assessment for environmentally sustainable hydroturbine passage.

13 HYDRO ENERGY↗

Space shuttle orbiter auxiliary power unit development challenges

When the flying spacecraft was approved for development, a power unit for the hydraulic system had to be developed. Unlike other systems on the orbiter, there was no precedent in earlier spacecraft for a hydraulic system nor for the power unit to drive the hydraulic pumps. The only prototypes available were airplane auxiliary power units (APU), which were not required to operate in the severe environments of a spacecraft nor to have the longevity of an orbiter hydraulic power unit. The challenge was to build a hydraulic power unit which could operate in 0g or 3g, in a vacuum or at sea level pressure, and at -65 F or 225 F, which would be capable of restarting while hot, and which would be capable of sustaining the hydraulic loads for the life of the orbiter. The basic approach to providing hydraulic power for the orbiter was to use a small, high speed, monopropellant fueled turbine power unit to drive a conventional aircraft type hydraulic pump. The stringent requirements imposed on the orbiter APU quickly made this machine different from existing aircraft APUs.

Lance, R.↗