Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen isotope separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

28 records · Page 2

The elemental and isotopic abundances of H, C, N, O in comets

The elemental abundances of light elements in comets is discussed by considering gas and dust separately. It is noted that the icy conglomerate model of the nucleus (Whipple, 1957) has been confirmed, and that the dust-to-gas mass ratio has been estimated within a factor of two for two recent comets. It is found that the total amount of oxygen available is also nominally in solar abundance; this implies that the oxygen of the solar nebula has probably been quantitatively bound in compounds that have been completely condensed and accreted in cometary nuclei. In addition, the amount of hydrogen is clearly depleted by a factor of 2,000, suggesting that the only hydrogen present is that linked in molecular compounds of H, C, N and O.

Delsemme, A. H.↗

Nuclear composition of solar cosmic rays

Experimental observations of the elemental and isotopic composition of solar flare particles are discussed. Sources and characteristics of particle-emitting solar flare events are reviewed, and techniques for separating particle species are briefly described. Data are presented for the elemental composition of the solar atmosphere, and the possibility of determining the solar helium abundance from solar cosmic-ray observations is explored. The main experimental determinations of heavy element abundances at energies greater and less than 10 MeV/nucleon are summarized, and techniques for measuring the ionic charge composition of solar cosmic rays are outlined. Models explaining heavy element enhancements are described along with processes leading to gamma-ray emission during solar flare events. Observations of the rare isotopes of hydrogen and helium during solar flare events are noted, and a lower atmospheric limit is derived for nuclear reactions leading to positron decay. The possibility of investigating low-energy solar cosmic rays by measuring the relative abundances of different elements is evaluated.

Hovestadt, D.↗

Sulfur and Hydrogen Isotope Anomalies in Organic Compounds from the Murchison Meteorite

Isotopic measurements have been made on organic sulfur and phosphorus compounds recently discovered in the Murchison meteorite. Carbon, hydrogen and sulfur measurements were performed on individual members of the organic sulfur compounds, alkyl sulfonates; and carbon and hydrogen measurements were made on bulk alkyl phosphonates. Cooper and Chang reported the first carbon isotopic measurements of Murchison organic sulfonates, providing insight into the potential synthetic mechanisms of these and, possibly, other organic species. Hydrogen isotopic measurements of the sulforiates now reveal deuterium excesses ranging from +660 to +2730 %. The deuterium enrichments indicate formation of the hydrocarbon portion of these compounds in a low temperature astrophysical environment consistent with that of dense molecular clouds. Measurements of the sulfur isotopes provide further constraints on the origin and mechanism of formation of these organic molecules. Recently, there has been growing documentation of sulfur isotopic anomalies in meteoritic material. Thiemens and Jackson have shown that some bulk ureilites possess excess S-33 and Thiemens et al. have reported excess S-33 in an oldhamite separate from the Norton County meteorite. Rees and Thode reported a large S-33 excess in an Allende acid residue, however, attempts to verify this measurements have been unsuccessful, possibly due to the heterogeneous nature of the carrier phase. With the recognition that sulfur isotopes may reflect chemistry in the protosolar nebula or the precursor molecular cloud, identification of potential carriers is of considerable interest. In the present study, the stable isotopes of sulfur were measured in methane sulfonic acid extracted from the Murchison meteorite. The isotopic composition was found to be: (delta)S-33 = 2.48 %, (delta)S-34 = 2.49 % and (delta)S-36 = 6.76 %. Based upon analysis of more than 60 meteoritic and numerous terrestrial samples, the mass fractionation lines are defined by Delta-33 = (delta)S-33 -0.50(delta)S-34 and Delta-36 = (delta)s-36 - 1.97 (delta)S-34. From these relationships Delta-33 = 1.24 % and Delta-36 = 0.89 % are observed. These anomalies, particularly the Delta-33, lie well outside the range of analytical uncertainty. They are the largest observed in any meteoritic component and the first found in an organosulfur compound. As discussed by Thiemens and Jackson, due to it's position on the periodic chart, sulfur undergoes chemically induced mass independent isotopic fractionations as does oxygen. Experiments by Mauersberger et. al. show that in such processes, the magnitude of fractionation for the different isotopically substituted species varies with mass and angular momentum; thus, anomalies are expected for both S-33 and S-36, but not necessarily of the same magnitude. Laboratory experiments have also confirmed that chemically produced, mass independent fractionations are mediated by molecular symmetry factors. A chemical source of fractionation requires that the sulfur isotopic anomaly was established in the gas phase, probably in reactions involving symmetric CS2. The discovery of an anomalous sulfur isotopic composition in a specific molecule containing excess deuterium is an important advance in the understanding of the cosmochemistry of sulfur. This evidence suggests that methanesulfonic acid was synthesized by interstellar processes. Further measurements and details of possible synthesis and fractionation mechanisms will be presented.

Cooper, G. W.↗

Carbon Isotope Characterization of Organic Intermediaries in Hydrothermal Hydrocarbon Synthesis by Pyrolysis-GC-MS-C-IRMS

We report results of experiments designed to characterize the carbon isotope composition of intermediate organic compounds produced as a result of mineral surface catalyzed reactions. The impetus for this work stems from recently reported detection of methane in the Martian atmosphere coupled with evidence showing extensive water-rock interaction during Martian history. Abiotic formation by Fischer-Tropsch-type (FTT) synthesis during serpentinization reactions may be one possible process responsible for methane generation on Mars, and measurement of carbon and hydrogen isotopes of intermediary organic compounds can help constrain the origin of this methane. Of particular interest within the context of this work is the isotopic composition of organic intermediaries produced on the surfaces of mineral catalysts (i.e. magnetite) during hydrothermal experiments, and the ability to make meaningful and reproducible isotope measurements. Our isotope measurements utilize a unique analytical technique combining Pyrolysis-Gas Chromatograph-Mass Spectrometry-Combustion-Isotope Ratio Mass Specrometry (Py-GC-MS-C-IRMS). Others have conducted similar pyrolysis-IRMS experiments on low molecular weight organic acids (Dias, et al, Organic Geochemistry, 33 [2002]). Our technique differs in that it carries a split of the pyrolyzed GC-separated product to a Thermo DSQ-II quadrupole mass spectrometer as a means of making qualitative and semi-quantitative compositional measurements of the organic compounds. A sample of carboxylic acid (mixture of C1 through C6) was pyrolyzed at 100 XC and passed through the GC-MS-C-IRMS (combusted at 940 XC). In order to test the reliability of our technique we compared the _13C composition of different molecular weight organic acids (from C1 through C6) extracted individually by the traditional sealed-tube cupric oxide combustion (940 XC) method with the _13C produced by our pyrolysis technique. Our data indicate that an average 4.3. +/-0.5. (V-PDB) apparent isotopic fractionation accompanies the pyrolysis extractions. We postulate that this isotope offset could be the result of incomplete thermal desorption during pyrolysis. We are continuing to investigate the reliability of this pyrolysis technique for correcting carbon isotope measurements of mineral surface catalyzed organic compounds.

Socki, Richard A.↗

Relic interstellar grains in Murchison meteorite

It is shown that, in the Murchison meteorite, the D/H ratios of hydrogen are unusually high in several separates and in one case up to 30 times the cosmic value of 2 x 10 to the -5th. Many phases show high C-13/C-12 ratios, up to 2.5 times the terrestrial value of 0.011. These C-13-rich and D-rich components of the two chemical elements are not correlated. They are heterogeneously distributed, suggesting that different components in the meteorite originated from different astrophysical sites and at different times. The D-rich hydrogen in the meteorite is probably due to molecules formed by ion-molecule reactions in interstellar clouds while the tiny amount of C-13-rich carbon is probably due to nucleosynthesis in red giant stars as suggested by Swart et al. (1983). Both of these heavy-isotope enriched components survived homogenization in the accumulation and subsequent history of the meteorites.

Yang, J.↗

Carbon and Hydrogen Isotope Measurements of Alcohols and Organic Acids by Online Pyroprobe-GC-IRMS

The detection of methane in the atmosphere of Mars, combined with evidence showing widespread water-rock interaction during martian history, suggests that the production of methane on Mars may be the result of mineral surface-catalyzed CO2 and or CO reduction during Fisher-Tropsch Type (FTT) reactions. A better understanding of these reaction pathways and corresponding C and H isotope fractionations is critical to deciphering the synthesis of organic compounds produced under abiotic hydrothermal conditions. Described here is a technique for the extraction and analysis of both C and H isotopes from alcohols (C1-C4) and organic acids (C1-C6). This work is meant to provide a "proof of concept" for making meaningful isotope measurements on complex mixtures of solid-phase hydrocarbons and other intermediary products produced during high-temperature and high-pressure synthesis on mineral-catalyzed surfaces. These analyses are conducted entirely "on-line" utilizing a CDS model 5000 Pyroprobe connected to a Thermo Trace GC Ultra that is interfaced with a Thermo MAT 253 isotope ratio mass spectrometer operating in continuous flow mode. Also, this technique is designed to carry a split of the GC-separated product to a DSQ II quadrupole mass spectrometer as a means of making semi-quantitative compositional measurements. Therefore, both chemical and isotopic measurements can be carried out on the same sample.

Socki, Richard A.↗

JPL-TMF multiwavelength aerosol lidar

The JPL-TMF Lidar Facility began operation in 1985 with the completion of a XeCl excimer based stratospheric ozone DIAL system. As an adjunct to this system a Nd:YAG based tropospheric ozone and aerosol system was assembled. The tropospheric ozone system was designed to utilize the fourth harmonic (266 nm) of the Nd:YAG to produce 289 nm, 294 nm or 299 nm by SRS in the isotopic hydrogen gases. The aerosol lidar was developed using the fundamental (1064 nm) and second harmonic of the Nd:YAG (532 nm). Following the eruption of Mount Pinatubo most of the effort was put into obtaining data on the layer structure of the volcanic aerosol as a function of altitude and time on a regular basis. During this period the tropospheric ozone DIAL was not employed on a regular schedule. The stratospheric measurements were of primary interest; however with the volcanic aerosol concentrated at the 16 - 26 km altitude the ozone concentration profile was perturbed. The aerosol interference in the ozone measurements caused the lidar community to seek techniques of measurement of the aerosol which could be used in making realistic corrections to the ozone measurements. It is generally accepted that a reasonable technique of measurement would include at least one channel of Raman scattering from a blue wavelength and a minimum of three other supporting wavelengths. With the primary transmitters available at TMF, a four wavelength system was considered for configuration. The four wavelength aerosol lidar is based on the Nd:YAG fundamental, the second and third harmonics of the transmitter. The receiver will separate these three wavelengths as well as the Raman scattering from atmospheric nitrogen of the third harmonic.

Haner, David A.↗

Hydrogen Isotope Measurements of Organic Acids and Alcohols by Pyrolysis-GC-MS-TC-IRMS: Application to Analysis of Experimentally Derived Hydrothermal Mineral-Catalyzed Organic Products

We report results of experiments to measure the H isotope composition of organic acids and alcohols. These experiments make use of a pyroprobe interfaced with a GC and high temperature extraction furnace to make quantitative H isotope measurements. This work compliments our previous work that focused on the extraction and analysis of C isotopes from the same compounds [1]. Together with our carbon isotope analyses our experiments serve as a "proof of concept" for making C and H isotope measurements on more complex mixtures of organic compounds on mineral surfaces in abiotic hydrocarbon formation processes at elevated temperatures and pressures. Our motivation for undertaking this work stems from observations of methane detected within the Martian atmosphere [2-5], coupled with evidence showing extensive water-rock interaction during Mars history [6-8]. Methane production on Mars could be the result of synthesis by mineral surface-catalyzed reduction of CO2 and/or CO by Fischer-Tropsch Type (FTT) reactions during serpentization [9,10]. Others have conducted experimental studies to show that FTT reactions are plausible mechanisms for low-molecular weight hydrocarbon formation in hydrothermal systems at mid-ocean ridges [11-13]. Our H isotope measurements utilize an analytical technique combining Pyrolysis-Gas Chromatograph-Mass Spectrometry-High Temperature Conversion-Isotope Ratio Mass Spectrometry (Py-GC-MS-TC-IRMS). This technique is designed to carry a split of the pyrolyzed GC-separated product to a Thermo DSQII quadrupole mass spectrometer as a means of making qualitative and semi-quantitative compositional measurements of separated organic compounds, therefore both chemical and isotopic measurements can be carried out simultaneously on the same sample.

Socki, Richard A.↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Soluble Organic Matter (SOM) analysis of the Hayabusa2 samples: The first results

The Hayabusa2 spacecraft successfully collected the surface and possible sub-surface materials of the asteroid 162173 Ryugu. Ryugu is a C-type asteroid characterized by a low-albedo surface probably consisting of hydrous minerals and carbonaceous materials. [1] The direct optical and spectral analysis of the returned samples indicates that Ryugu material is dominated by hydrous carbonaceous chondrite-like matter (similar to CI chondrites) [2]. Since carbonaceous chondrites have generally yielded various types of organic matter, the collected Ryugu grains are expected to contain diverse types of organic compounds including bio-related molecules. The occurrence of organic compounds in the Ryugu surface will provide clues to the evolution of prebiotic molecules and their preservations associated with aqueous alteration of the primitive asteroid. The initial analysis of soluble organic matter (SOM) of the Hayabusa2-returned samples has been performed by an international team consisting of 32 members. Because the sample amount available for comprehensive SOM analyses is limited, and because the SOM is expected to be present as a complex mixture of various types of organic compounds with very small concentrations of each compound, high-sensitivity and high-resolution analytical techniques have been developed using carbonaceous meteorites [e.g. 3]. Two aggregate samples of the Ryugu grains (A106 and C107) were allocated for the solvent extractions and bulk carbon (C), hydrogen (H), nitrogen (N), sulfur (S) and oxygen (O) measurements. The A106 sample was collected during the 1st sampling in February 2019 and the C107 sample was collected during the 2nd sampling in July 2019 after the Small Carry Impactor (SCI) operation. They consist mainly of particles smaller than 1 mm in diameter, and each sample mass was 38-39 mg. They were firstly investigated spectroscopically in the near infrared wavelength range by the Stone Team prior to the solvent extractions. Other small grains (A0080 and C0057) were also allocated for this study to investigate the spatial distribution of organic compounds on the sample surface. The extraction and analytical measurements implemented by the SOM Team are summarized in Figure 1. Each powder sample was extracted sequentially with non-polar to polar solvents, i.e., hexane, dichloromethane (DCM), methanol (MeOH) and H2O, for non-targeted analysis to reveal the compound composition. Each solvent extract was analyzed by solution state nuclear magnetic resonance (NMR) spectroscopy [4], Fourier transform- ion cyclotron resonance/mass spectrometry (FT-ICR/MS) with ESI and APPI ionization [5] and by high-resolution mass spectroscopy using Orbitrap MS coupled with nano-liquid chromatography (nanoLC/Orbitrap MS) [6], and using two dimensional gas chromatography/mass spectrometry (GC×GC/MS). The extracted residues were passed to the Chemistry Team for further inorganic element analysis. The other powder sample was subjected to the hot water extraction for amino acid analyses including chiral isomer separation, which was performed by three-dimensional (3D) high-performance liquid chromatography (HPLC) with high-sensitivity fluorescence detection (FD) [7] and by HPLC/FD coupled with quadrupole-time of flight/mass spectrometry (QToF/MS) [8]. After the hot water extraction, the residue was split into two halves. One half was further extracted with hydrochloric acid (HCl) to analyze for amino acids in bound-form. The other half was sequentially extracted with DCM/MeOH (1/1) to analyze semi-polar compounds such as polycyclic aromatic hydrocarbons (PAHs) by GC/MS, followed by further extraction with formic acid to analyze polar heterocyclic compounds, and subsequent extraction with HCl to detect bound-form polar compounds. The extracted residues were passed to the IOM Team for the analysis of insoluble organic matter (IOM). Compound-specific stable isotope analyses will be performed using GC/combustion/isotope ratio mass spectrometry (GC/C/IRMS) if the compound concentration is high enough to enable such an isotopic measurement. All extraction procedures were performed on an ISO 6 (Class 100) clean bench inside an ISO 5 (Class 1000) clean room. Baked serpentine powder was also analyzed as a procedural blank. In situ organic compound analysis with the molecular imaging was performed using desorption electrospray ionization (DESI) equipped with Orbitrap MS [9, 10], followed by spatial imaging of organic compounds using ToF/secondary ion mass spectrometry (ToF/SIMS) [11]. The bulk chemical and isotopic compositions of CNS and HO were determined using nano-elemental analysis/isotope ratio mass spectrometry (nanoEA/IRMS) [12] and EA/pyrolysis/IRMS, respectively. We have identified a variety of indigenous organic compounds in the extracts of both A106 and C107 samples. The Ryugu grains host organic molecules under the high-vacuum and cosmic-ray irradiation environment of the asteroid surface. The analysis of extracted molecules is in progress, and the first results will be presented at the symposium.

Hiroshi Naraoka↗