Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen storage systems,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Integrated Hydrogen Energy Storage System (IHESS) for Power Generation (Final Report)

GTI Energy partnered with Praxair Inc., a subsidiary of Linde PLC (Praxair), the Center for Electromechanics at the University of Texas at Austin (CEM), Entergy Corporation (Entergy), Quanta Services (Quanta) and Mitsubishi Heavy Industries (MHI) to perform a feasibility study that determines the economic and technical feasibility of low-carbon hydrogen energy storage integrated with a site-specific fossil fuel asset to decarbonize electricity production using the Integrated Hydrogen Energy Storage System (IHESS). The proposed IHESS concept is novel, as it sought to leverage the existing natural gas infrastructure, hydrogen production and pipelines, existing underground hydrogen storage system and power plants in the Gulf Coast region to reduce carbon emissions and generate lowcarbon electricity. This study has shown that IHESS has a promising commercial outlook as the concept leverages existing natural gas infrastructure assets and hydrogen production and storage that are unique to the Texas gulf coast region. A key hurdle with hydrogen supply and transportation has been capital investment. By storing hydrogen in underground storage and delivering it as a fuel source during peak demand using the existing infrastructure minimizes the capital investment. Regional petrochemical producers who are actively seeking opportunities to reduce costs and lower emissions should find the IHESS concept very appealing.

03 NATURAL GAS↗

Design tool for estimating metal hydride storage system characteristics for light-duty hydrogen fuel cell vehicles

The U.S. Department of Energy (DOE) has developed the Framework model to simulate fuel cell-based light-duty vehicle operation for various hydrogen storage systems. This transient model simulates the performance of the storage system, fuel cell, and vehicle for comparison to DOE's Technical Targets using four drive cycles. Metal hydride hydrogen storage models have been developed for the Framework model. Despite the utility of this model, it requires that material researchers input system design specifications that cannot be easily estimated. To confront this challenge, a design tool has been developed that allows researchers to directly enter physical and thermodynamic metal hydride properties into a simple sizing module that then estimates the systems parameters required to run the storage system model. This design tool can also be used as a standalone MS Excel model to estimate the storage system mass and volume outside of Framework and compare it to the DOE Technical Targets. This model will be explained and exercised with existing hydrogen storage materials.

33 ADVANCED PROPULSION SYSTEMS↗

Electrolyte Assisted Hydrogen Storage Reactions (Final Technical Report)

The goal of this project is to address critical deficiencies of hydrogen storage systems design based on hydride materials, as originally identified by the DOE Hydrogen Storage Engineering Center of Excellence (HSECoE). Baseline hydrogen storage technology presently relies on compressed gas operating at ~700 bar pressure, which imposes huge demands on fuel delivery, fuel storage and system cost. For onboard storage applications, Type IV composite overwrapped pressure vessels and associated balance-of-plant components are necessary to ensure safe and effective fuel delivery. However, such compressed gas technology falls well-short of volumetric targets even at 700 bar, given the density of gaseous molecular hydrogen is only 40 g·H2/l at ambient temperatures. One alternative is to utilize hydride materials which accommodate hydrogen in atomic form. Certain hydrides can attain volumetric densities that exceed the density of liquid H2 (71 g·H2/l) while also offering advantageous thermodynamic properties. However, such material systems presently rely on solid-state diffusion for hydrogen release, which has a very high activation barrier for atom mobility and, thus, requires impractically-high temperatures for operation. The initial focus of our research effort is to employ and demonstrate an electrolyte system to mediate the diffusion of species at lower temperatures relevant to transportation applications, with the goal of establishing the critical factors necessary to obviate the need for high-temperature release of hydrogen. A parallel goal of this exploratory effort is to determine the effectiveness of modest electrochemical potentials in overcoming any endothermic requirements for hydrogen release in a similar electrolyte-promoted scenario.

08 HYDROGEN↗

Porous materials for hydrogen storage

Hydrogen is a clean energy carrier and a promising candidate to realize carbon-neutral systems for a sustainable future because the combustion of hydrogen produces only water. The large-scale implementation of hydrogen, particularly in zero-emission hydrogen-powered fuel-cell automobiles, requires efficient hydrogen storage systems; however, the current on-board hydrogen storage technologies mainly rely on costly and potentially unsafe high-pressure compression strategies that reach pressures of up to 700 bar. Recently, solid-state porous materials, such as metal-organic frameworks, have emerged as sorbents that can conceivably store comparable amounts of hydrogen in a safer and more efficient manner relative to the current high-pressure storage technologies. Here this review summarizes the current progress on the development of state-of-the-art porous materials and their composites for hydrogen storage. We hope this work will inspire efforts toward creating next-generation hydrogen storage materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of High Capacity Energy Storage Materials

Hydrogen fuel cells have the potential to offer energy and power density advantages over lithium ion batteries in automotive and portable power applications when paired with an appropriate hydrogen storage system. Development of the ideal hydrogen storage material has been immensely sought after but plagued by limitations present in each type of material. These limitations typically include nonidealistic operational temperatures, low capacities, excessive costs, lack of reversibility, or evolution of impurities which irreversibly damage fuel cell performance. Many complex metal hydrides possess suitable hydrogen capacities but unfortunately suffer from impurity release. In order to address this problem, our team has explored in-situ catalyst doping of alkali metal amides to demonstrate methodologies to reduce ammonia release. The incorporation of iridium metal in lithium amide significantly reduces the ammonia release and decomposes the ammonia to provide additional hydrogen. Furthermore, we demonstrate, for the first time, high resistance of low temperature fuel cells to ammonia in comparison with typical proton exchange membrane fuel cells. The utilization of these two approaches in tandem provides a novel pathway for the development and implementation of high capacity energy storage materials for fuel cell applications.

25 ENERGY STORAGE↗

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems may become more widely deployed throughout the country, and so it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity of the facility, and the company that owns the facility. The two main ways bad actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when companies conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks associated with a generic hydrogen storage system by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by the principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m 2 /g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature and high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, constructed from readily available commercial materials, and lends itself to a range of pressure applications. The project team designed and manufactured the CFC, integrating it into a set of temperature-controlled flow loops. The CFC test setup was validated against existing data from previous NASA work. Tests used bottled hydrogen gas for test validation. A cryogenic fluid, nitrogen, flowed through a metered control system. Hydrogen temperature, pressure, and flow rates, as well as the temperature control targets, provided all necessary control targets. The team analyzed the recorded data and updated the Technology Maturation Plan based on the results of the test, making recommendations for a follow-up test, scale-up, and maturation pathway. For the engineering development and maturation of CFC hydrogen storage technology, a Techno-Economic Assessment (TEA) and Commercialization Plan for the integration of this technology with various power generation assets were produced. A companion analytical model was developed, experimentally validated, compared against performance metric, and used to tune the model and scale up the technology.

08 HYDROGEN↗

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems are becoming more widely deployed throughout the country, and as their presence continues to grow, it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity, and to the company that owns the facility. The two main mechanisms malicious actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when facility managers conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks applicable to a wide variety of hydrogen storage systems by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

Development of an Advanced Hydrogen Energy Storage System using Aerogel in a Cryogenic Flux Capacitor (CFC)

The Cryogenic Flux Capacitor (CFC) is a cold, dense fluid storage core with integrated design features that afford the designer flexibility and provide new possibilities for the storage and discharge of energy. The stored energy, in this case, is represented by hydrogen physically bonded within the nanoscale pores within the aerogel composite blanket material, and the process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows for storage densities close to, or in some cases exceeding, that of normal boiling point liquids. Its performance easily exceeds what can be achieved via ambient temperature, high-pressure gas storage for an equivalent volume. CFC storage is predicted to be easily scalable, is constructed from readily available commercial materials, lends itself to a range of pressure applications, and is geometry insensitive. They can also be used in modular designs, affording even more flexibility for potential deployment. In addition to the aerogel adsorbent within the blanket material, a CFC includes thermally-conductive membrane layered with the aerogel, which acts as a large-area, quick-response thermal management system. The system conducts heat throughout the volume to discharge the unit quickly. This same thermal management system can also be connected to a refrigeration system, or cold fluid such as liquid nitrogen (LN2), to facilitate the charging up of the CFC. The charging and discharging can be performed as fast or as slow as desired by controlling the cooling or heating supplied to the CFC.

08 HYDROGEN↗

Design and requirements of a hydrogen component reliability database (HyCReD)

Hydrogen technologies are expected to play a key role in the decarbonization of several sectors including energy storage and transportation. Rigorous investigation and quantification of the risk and reliability issues associated with hydrogen technologies will be critical to ensuring both their wider adoption and safe, economical operations. Quantitative risk assessment (QRA) is an important tool that has been used to enable the safe deployment of many engineering systems, including hydrogen fueling stations and hydrogen storage systems. However, QRA studies require reliability data which is currently lacking for expanding applications of hydrogen systems. Here, to address this gap, we present a new structure for a hydrogen component reliability database (HyCReD) that can be used to generate reliability data to be used in QRA, reliability, safety studies, maintenance planning, and more. Building on our previous work examining four major hydrogen safety data collection tools (West et al., 2022) [1], our approach in this work was to consult scientific literature on reliability data collection as well as a number of existing reliability engineering databases in the oil & gas, chemical processing, and nuclear power plant sectors. The evaluation of these databases led to identifying best practices to be implemented in a data collection framework for a hydrogen component reliability database. Based on these best practices, a set of 24 requirements for the proposed database are presented, covering its characteristics and the types of data to be collected. We define the structure of the HyCReD database and 25 data elements to be collected, spanning system description, failure, shutdown, or near-miss events, and maintenance events. The data elements are then defined according to international standards used in the safety and reliability practice and potential choice lists are provided for each field. Since this database is being piloted for hydrogen fueling stations, a generic station component hierarchy developed by West (2021) [2] is used to standardize system data. Finally, we demonstrate populating the database with information extracted from five narrative reports on hydrogen fueling station incidents.

08 HYDROGEN↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100 Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

Borrego Springs↗

Hydrogen Energy Storage System at Borrego Springs Towards an H2 Enabled 100% Renewable Microgrid

San Diego Gas & Electric's Borrego Springs Microgrid is one of the largest microgrids in the USA, serving 2500 residential customers, 300 commercial and industrial customers, and has a peak demand of approximately 14 MW. This microgrid is located at the end of a long transmission line, and is subjected to extreme weather events like storms, wildfires, and flooding, which frequently cause grid outages. The microgrid currently relies on 3.65 MW of diesel-powered generators to provide grid-forming services during these outages, which results in greenhouse gas and criteria pollutant emissions. However, the microgrid has access to approximately 37 MW of installed solar generation and struggles with overgeneration and curtailment. 1.5 MW/4.5 MWh of grid-scale batteries have been installed to capture some the overgeneration and provide resiliency, but a longer-duration low-greenhouse gas emission energy storage solution is needed. In our project, the team will evaluate in the lab and demonstrate in the field a grid-forming fuel cell inverter that can provide grid-forming services while utilizing hydrogen's energy storage scalability. We will first utilize NREL's Renewable Energy Integration and Optimization (REopt) platform to perform analyses on future microgrid scenarios that use hydrogen assets to reduce or eliminate the need for diesel backup generators. We will then evaluate the grid-forming inverter through power hardware-in-the-loop and controller hardware-in-the-loop experiments at ARIES, and de-risk the field deployment and operation of hydrogen assets in the microgrid setting. Finally, this project will demonstrate the operation of the fuel cell inverter and updated microgrid controller by operating in grid-forming mode in the Borrego Springs microgrid.

blackstart with fuel cells↗

Structure of a seeded palladium nanoparticle and its dynamics during the hydride phase transformation

Palladium absorbs large volumetric quantities of hydrogen at room temperature and ambient pressure, making the palladium hydride system a promising candidate for hydrogen storage. Here, we use Bragg coherent diffraction imaging to map the strain associated with defects in three dimensions before and during the hydride phase transformation of an individual octahedral palladium nanoparticle, synthesized using a seed-mediated approach. The displacement distribution imaging unveils the location of the seed nanoparticle in the final nanocrystal. By comparing our experimental results with a finite-element model, we verify that the seed nanoparticle causes a characteristic displacement distribution of the larger nanocrystal. During the hydrogen exposure, the hydride phase is predominantly formed on one tip of the octahedra, where there is a high number of lower coordinated Pd atoms. Our experimental and theoretical results provide an unambiguous method for future structure optimization of seed-mediated nanoparticle growth and in the design of palladium-based hydrogen storage systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precursor Processing Development for Low Cost, High Strength Carbon Fiber for Composite Overwrapped Pressure Vessel Applications

Carbon fiber (CF) is central to produce lightweight, high pressure, composite overwrapped pressure vessels (COPVs), which are used for on-board storage of hydrogen for fuel cell vehicles. In 2015, carbon fiber cost accounted for 62% of the cost of a hydrogen storage system, as COPVs were manufactured with T700S CF at $\$ $29.40/kg CF. The high cost of hydrogen storage, largely attributed to the carbon fiber cost, limits the application of fuel cells in vehicles. Therefore, our team endeavored to develop fiber processing to demonstrate carbon fiber tensile properties similar to T700S with a production cost potential of $\$ $12.60/kg or less. Here, the overarching goal of the project was the development of low cost, high strength carbon fiber for composite overwrapped pressure vessels. Within the project, our team investigated a new low-cost, high-volume, high quality polyacrylonitrile (PAN)-based precursor terpolymer for the production of carbon fiber precursors, methods for increasing water and energy use efficiency in wash-water/solvent separation, and ultimately developed a multifilament spinning and conversion process for the production of hollow carbon fibers from a segmented arc spinneret utilizing a solution spinning method.

08 HYDROGEN↗

Foam-insulated cryo-compressed hydrogen storage vessels for buses

Here, large reductions (40 % vs. compressed gaseous hydrogen vessels and 17 % vs. vacuum insulated cryo-compressed vessels) in hydrogen storage system cost are possible by operating buses with foam-insulated cryo-compressed hydrogen (CcH 2 ) vessels. Detailed thermodynamic analysis reveals that large size and rapid H 2 consumption in buses compensate for the poor performance of foam insulation (∼100 times more conductive than vacuum multilayer insulation), resulting in compact and inexpensive H 2 storage systems with sufficient H 2 capacity for the longest routes (500 km) while maintaining previously identified advantages of CcH 2 systems: increased autonomy, rapid high density refueling, and improved safety, while simultaneously avoiding vacuum insulation stability problems resulting from composite resin outgassing.

Cryo-compressed↗