Search NASA⌕ Search

SEARCH · Search NASA

Results for “image detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Real-time biomass feedstock particle quality detection using image analysis and machine vision

Abstract A common and costly challenge in the nascent biorefinery industry is the consistent handling and conveyance of biomass feedstock materials, which can vary widely in their chemical, physical, and mechanical properties. Solutions to cope with varying feedstock qualities will be required, including advanced process controls to adjust equipment and reject feedstocks that do not meet a quality standard. In this work, we present and evaluate methods to autonomously assess corn stover feedstock quality in real time and provide data to process controls with low-cost camera hardware. We explore the use of neural networks to classify feedstocks based on actual processing behavior and pixel matrix feature parameterization to further assess particle attributes that may explain the variable processing behavior. We used the pretrained ResNet neural network coupled with a gated recurrent unit (GRU) time-series classifier trained on our image data, resulting in binary classification of feedstock anomalies with favorable performance. The textural aspects of the image data were statistically analyzed to determine if the textural features were predictive of operational disruptions. The significant textural features were angular second moment, prominence, mean height of surface profile, mean resultant vector, shade, skewness, variation of the polar facet orientation, and direction of azimuthal facets. Expansion of these models is recommended across a wider variety of labeled feedstock images of different qualities and species to develop a more robust tool that may be deployed using low-cost cameras within biorefineries.

09 BIOMASS FUELS↗

An image classification deep-learning algorithm for shrapnel detection from ultrasound images

Ultrasound imaging is essential for non-invasively diagnosing injuries where advanced diagnostics may not be possible. However, image interpretation remains a challenge as proper expertise may not be available. In response, artificial intelligence algorithms are being investigated to automate image analysis and diagnosis. Here, we highlight an image classification convolutional neural network for detecting shrapnel in ultrasound images. As an initial application, different shrapnel types and sizes were embedded first in a tissue mimicking phantom and then in swine thigh tissue. The algorithm architecture was optimized stepwise by minimizing validation loss and maximizing F1 score. The final algorithm design trained on tissue phantom image sets had an F1 score of 0.95 and an area under the ROC curve of 0.95. It maintained higher than a 90% accuracy for each of 8 shrapnel types. When trained only on swine image sets, the optimized algorithm format had even higher metrics: F1 and area under the ROC curve of 0.99. Overall, the algorithm developed resulted in strong classification accuracy for both the tissue phantom and animal tissue. This framework can be applied to other trauma relevant imaging applications such as internal bleeding to further simplify trauma medicine when resources and image interpretation are scarce.

59 BASIC BIOLOGICAL SCIENCES↗

Change-point Detection and Image Segmentation for Time Series of Astrophysical Images

Many astrophysical phenomena are time-varying, in the sense that their intensity, energy spectrum, and/or the spatial distribution of the emission suddenly change. This paper develops a method for modeling a time series of images. Under the assumption that the arrival times of the photons follow a Poisson process, the data are binned into 4D grids of voxels (time, energy band, and x-y coordinates), and viewed as a time series of non-homogeneous Poisson images. The method assumes that at each time point, the corresponding multiband image stack is an unknown 3D piecewise constant function including Poisson noise. It also assumes that all image stacks between any two adjacent change points (in time domain) share the same unknown piecewise constant function. The proposed method is designed to estimate the number and the locations of all of the change points (in time domain), as well as all of the unknown piecewise constant functions between any pairs of the change points. The method applies the minimum description length principle to perform this task. A practical algorithm is also developed to solve the corresponding complicated optimization problem. Simulation experiments and applications to real data sets show that the proposed method enjoys very promising empirical properties. Applications to two real data sets, the XMM observation of a flaring star and an emerging solar coronal loop, illustrate the usage of the proposed method and the scientific insight gained from it.

79 ASTRONOMY AND ASTROPHYSICS↗

Legacy Survey of Space and Time Data Preview 1: dia_source dataset type

The Legacy Survey of Space and Time Data Preview 1 (DP1) is the first release of data from the NSF-DOE Vera C. Rubin Observatory. It consists of raw and calibrated single-epoch images, co-adds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of approximately 15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. This dataset is a subset of the full data release consisting of the dia_source dataset type. These are measurements for detected sources in difference images. This release contains 25 datasets of this type.

79 ASTRONOMY AND ASTROPHYSICS↗

Legacy Survey of Space and Time Data Preview 1: DiaSource searchable catalog

The Legacy Survey of Space and Time Data Preview 1 (DP1) is the first release of data from the NSF-DOE Vera C. Rubin Observatory. It consists of raw and calibrated single-epoch images, co-adds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of approximately 15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. This dataset is a subset of the full data release consisting of a searchable catalog named DiaSource. This catalog contains measurements for detected sources in difference images. This catalog contains 3,086,404 rows with 87 columns.

79 ASTRONOMY AND ASTROPHYSICS↗

Legacy Survey of Space and Time Data Preview 1: source dataset type

The Legacy Survey of Space and Time Data Preview 1 (DP1) is the first release of data from the NSF-DOE Vera C. Rubin Observatory. It consists of raw and calibrated single-epoch images, co-adds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of approximately 15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. This dataset is a subset of the full data release consisting of the source dataset type. These are measurements for detected sources in processed visit images. This release contains 1,786 datasets of this type.

79 ASTRONOMY AND ASTROPHYSICS↗

Legacy Survey of Space and Time Data Preview 1: Source searchable catalog

The Legacy Survey of Space and Time Data Preview 1 (DP1) is the first release of data from the NSF-DOE Vera C. Rubin Observatory. It consists of raw and calibrated single-epoch images, co-adds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of approximately 15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. This dataset is a subset of the full data release consisting of a searchable catalog named Source. This catalog contains measurements for detected sources in processed visit images. This catalog contains 45,565,632 rows with 156 columns.

79 ASTRONOMY AND ASTROPHYSICS↗

Image Processing Pipeline for Fluoroelastomer Crystallite Detection in Atomic Force Microscopy Images

Phase transformations in materials systems can be tracked using atomic force microscopy (AFM), enabling the examination of surface properties and macroscale morphologies. In situ measurements investigating phase transformations generate large datasets of time-lapse image sequences. The interpretation of the resulting image sequences, guided by domain-knowledge, requires manual image processing using handcrafted masks. Here this approach is time-consuming and restricts the number of images that can be processed. Her in this study, we developed an automated image processing pipeline which integrates image detection and segmentation methods. We examine five time-series AFM videos of various fluoroelastomer phase transformations. The number of image sequences per video ranges from a hundred to a thousand image sequences. The resulting image processing pipeline aims to automatically classify and analyze images to enable batch processing. Using this pipeline, the growth of each individual fluoroelastomer crystallite can be tracked through time. We incorporated statistical analysis into the pipeline to investigate trends in phase transformations between different fluoroelastomer batches. Understanding these phase transformations is crucial, as it can provide valuable insights into manufacturing processes, improve product quality, and possibly lead to the development of more advanced fluoroelastomer formulations.

36 MATERIALS SCIENCE↗

A Demonstration of Intelligent Container Surveillance Using Stationary and Mobile Camera Platforms

Surveillance of nuclear material storage containers is required to ensure that the container safety boundary is maintained during the service life of the container. As many of these container types are the first and only containment barrier to release protecting the worker, public, and environment, it is imperative to develop robust surveillance tools to characterize container degradation. Machine learning (ML) techniques have matured quickly in the past decade and are slowly becoming a routine application in data analysis. While more popular architectures have been developed with different applications in mind, these can be easily translated to container surveillance requirements. In this study, we developed a ML model based on the Detectron2 framework to identify slip lid containers and common exterior container defects, primarily dents. Commercial-off-the-shelf cameras are combined into a stationary camera array or are mounted to a robotic arm to provide more mobility for positioning needs. Results from the model evaluations on the images indicate that the stationary camera arrays outperform the accuracy of the mobile camera systems for both individual camera and composite image detections. Overall, however, the detection accuracies of the systems fell short of 50% and were less than satisfactory. Future efforts to improve the system involve focusing on a single camera deployable solution that combines a controllable light source that eliminates one of the biggest environmental factors that influence ML model detection performance. Additional training set collection is planned to build a more robust model that enables accurate detection from a wider range of imaging conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Applying Multimodal Mass Spectrometry to Image Tumors Undergoing Ferroptosis Following In Vivo Treatment with a Ferroptosis Inducer

Epithelial ovarian cancer (EOC) is the most common form of ovarian cancer. The poor prognosis generally associated with this disease has led to the search for improved therapies such as ferroptosis-inducing agents. Ferroptosis is a form of regulated cell death that is dependent on iron and is characterized by lipid peroxidation. Precise mapping of lipids and iron within tumors exposed to ferroptosis-inducing agents may provide insight into processes of ferroptosis in vivo and ultimately assist in the optimal deployment of ferroptosis inducers in cancer therapy. In this work, we present a method for combining matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) with secondary ion mass spectrometry (SIMS) to analyze changes in spatial lipidomics and metal composition, respectively, in ovarian tumors following exposure to a ferroptosis inducer. Tumors were obtained by injecting human ovarian cancer tumor-initiating cells into mice, followed by treatment with the ferroptosis inducer erastin. SIMS imaging detected iron accumulation in the tumor tissue, and sequential MALDI-MS imaging of the same tissue section displayed two chemically distinct regions of lipids. Additionally, one region was associated with the iron-rich area detected with SIMS, and the other region encompassed the remainder of the tissue section. Bulk lipidomics confirmed the lipid assignments putatively assigned from the MALDI-MS data. Overall, we demonstrate the ability of multimodal MSI to identify the spatial locations of iron and lipids in the same tissue section and associate these regions with clinical pathology.

60 APPLIED LIFE SCIENCES↗

Block segmentation in feature space for realtime object detection in high granularity images

Computer vision has applications in object detection, image recognition and classification, and object tracking. One of the challenges of computer vision is the presence of useful information at multiple distance scales. Filtering techniques may sacrifice details at small scales in order to prioritize the analysis of large-scale features of the image. We present a strategy for coarse-graining multidimensional data while maintaining fine-grained detail for subsequent analysis. The algorithm is based on fixed-size block segmentation in the feature space. We apply this strategy to solve the long-standing challenge of detecting particle trajectories at the Large Hadron Collider in real time.

Computer vision↗