Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

T staging esophageal tumors with x rays

With histopathology results typically taking several days, the ability to stage tumors during interventions could provide a step change in various cancer interventions. X-ray technology has advanced significantly in recent years with the introduction of phase-based imaging methods. These have been adapted for use in standard labs rather than specialized facilities such as synchrotrons, and approaches that enable fast 3D scans with conventional x-ray sources have been developed. This opens the possibility to produce 3D images with enhanced soft tissue contrast at a level of detail comparable to histopathology, in times sufficiently short to be compatible with use during surgical interventions. In this paper we discuss the application of one such approach to human esophagi obtained from esophagectomy interventions. We demonstrate that the image quality is sufficiently high to enable tumor T staging based on the x-ray datasets alone. Alongside detection of involved margins with potentially life-saving implications, staging tumors intra-operatively has the potential to change patient pathways, facilitating optimization of therapeutic interventions during the procedure itself. Besides a prospective intra-operative use, the availability of high-quality 3D images of entire esophageal tumors can support histopathological characterization, from enabling “right slice first time” approaches to understanding the histopathology in the full 3D context of the surrounding tumor environment.

Optics↗

A Vertical Deburring Algorithm for Muon Tomography

Los Alamos researchers have developed a technology that improves the quality of images generated by muon tomography techniques,where naturally existing cosmic radiation is used as an energy source for identifying very dense materials. When using muon tomography,blurring can occur on the vertical aspect of images, making it more difficult to interpret data. This vertical de-blurring technology will correct these abnormalities and improve image quality for better evaluation of containers that may have dense matter such as special nuclear materials. This technology has been demonstrated in the laboratory and was evaluated in the field for efficacy.

47 OTHER INSTRUMENTATION↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

Surrogate Distributed Radiological Sources—Part III: Quantitative Distributed Source Reconstructions

In this third part of a multi-paper series, we present quantitative image reconstruction results from aerial measurements of eight different surrogate distributed gamma-ray sources on flat terrain. Here, we show that our quantitative imaging methods can accurately reconstruct the expected shapes, and, after appropriate calibration, the absolute activity of the distributed sources. We conduct several studies of imaging performance versus various measurement and reconstruction parameters, including detector altitude and raster pass spacing, data and modeling fidelity, and regularization type and strength. The imaging quality performance is quantified using various quantitative image quality metrics. Our results confirm the utility of point source arrays as surrogates for truly distributed radiological sources, and advance the quantitative capabilities of Scene Data Fusion gamma-ray imaging methods.

Airborne survey↗

Fabrication of a Point-Like Transmission Target for Reducing Computed Tomography Imaging Artifacts

In this study, we address the challenge of enhancing image quality and spatial resolution in computed tomography (CT) imaging by introducing simulation and fabrication of high aspect ratio, point-like transmission targets. Utilizing advanced electroplating techniques, traditionally employed in the fabrication of Through Substrate Via (TSV) interconnects for CMOS circuitry, we successfully embed copper targets within silicon substrates. This method allows us to create high-aspect-ratio features specifically designed for X-ray transmission targets, resulting in micro targets that exhibit a volume increase compared to conventional evaporated surface targets. Furthermore, we present simulation results of the X-ray spectrum generated by these targets, demonstrating their potential to significantly improve both image quality and spatial resolution in CT applications. Our findings suggest that leveraging advanced fabrication techniques can open new avenues for the development of enhanced imaging technologies in medical diagnostics and beyond.

47 OTHER INSTRUMENTATION↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stable parallel training of Wasserstein conditional generative adversarial neural networks

In this work, we propose a stable, parallel approach to train Wasserstein conditional generative adversarial neural networks (W-CGANs) under the constraint of a fixed computational budget. Differently from previous distributed GANs training techniques, our approach avoids inter-process communications, reduces the risk of mode collapse and enhances scalability by using multiple generators, each one of them concurrently trained on a single data label. The use of the Wasserstein metric also reduces the risk of cycling by stabilizing the training of each generator. We illustrate the approach on the CIFAR10, CIFAR100, and ImageNet1k datasets, three standard benchmark image datasets, maintaining the original resolution of the images for each dataset. Performance is assessed in terms of scalability and final accuracy within a limited fixed computational time and computational resources. To measure accuracy, we use the inception score, the Fréchet inception distance, and image quality. An improvement in inception score and Fréchet inception distance is shown in comparison to previous results obtained by performing the parallel approach on deep convolutional conditional generative adversarial neural networks as well as an improvement of image quality of the new images created by the GANs approach. Weak scaling is attained on both datasets using up to 2000 NVIDIA V100 GPUs on the OLCF supercomputer Summit.

97 MATHEMATICS AND COMPUTING↗

Blinding scheme for the scale-dependence bias signature of local primordial non-Gaussianity for DESI 2024

The next generation of spectroscopic surveys is expected to achieve an unprecedented level of accuracy in the measurement of cosmological parameters. To avoid confirmation bias and thereby improve the reliability of these results, blinding procedures become a standard practice in the cosmological analyses of such surveys. Blinding is especially crucial when the impact of observational systematics is important relative to the cosmological signal, and a detection of that signal would have significant implications. This is the case for local primordial non-gaussianity, as probed by the scale-dependent bias of the galaxy power spectrum at large scales that are heavily sensitive to the dependence of the target selection on the imaging quality, known as imaging systematics. We propose a blinding method for the scale-dependent bias signature of local primordial non-gaussianity at the density field level which consists in generating a set of weights for the data that replicate the scale-dependent bias. The applied blinding is predictable, and can be straightforwardly combined with other catalog-level blinding procedures that have been designed for the baryon acoustic oscillation and redshift space distortion signals. The procedure is validated through simulations that replicate data from the first year of observation of the Dark Energy Spectroscopic Instrument, but may find applications to other upcoming spectroscopic surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Visualization Quality Assessment

Understanding how inaccuracies in visualizations affect users’ perception and understanding of scientific data is hard. Inaccuracies in visualizations are quite common and could arise from a range of sources such as errors in the original dataset arising from compression artifacts, errors in the capturing device, noise during transmission of the data, effects due to the algorithm being used to convert data to visualization images, images generated from neural networks, and sources we have yet to discover. Many image quality assessment metrics have been developed to quantify image errors. However, these are usually focused on “natural images” rather than visualizations of scientific data. Common image quality assessment metrics (IQAs) include MSE, PSNR, perceptual metrics such SSIM, FSIM as well as perceptual metrics using deep learning approaches. However, a critical part of understanding how errors are perceived by humans, and subsequently developing more accurate quality assessment metrics, is through user evaluation studies. The goal of this software is to develop a visualization quality assessment (VQA) process that will enable the generation of VQAs that can be used to quantify errors in scientific data visualizations. The VQA development process will include software to support user evaluation experimental design, analysis of visualization differences against standard quality metrics, and the ability to develop additional VQA metrics specific to scientific visualization images.

Grosset, Andre↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Fluorescence strobo-stereoscopy for specular reflection-suppressed full field of view imaging

This report introduces fluorescence strobo-stereoscopy (FSS) to suppress strong specular reflection and enable the full field of view (FFOV) 3D surface imaging while the part is rotating. Specular reflection off the target surface significantly degrades the image quality and becomes critical for highly reflective surface measurements. In FSS, the fluorescent dye-doped fluid applied on the machined surface is excited upon incident ultra-violet light and becomes a new light source by Stokes' Law. Thus, specular reflection off of smooth surface can be suppressed by separating the fluorescent light from the excitation light. The developed FSS comprises a pair of imaging cameras, spatial filters, and an excitation light source. As a result, FSS effectively rejected the specular reflection and improved the FFOV 3D surface image quality of the machined part by enhancing contrast in the rotating target surface. Such enhancements in 3D imaging allowed to identify manufacturing tolerance of the part and to detect the surface features. The axial and lateral accuracy errors of FSS were 2.3% and 1.4% with the target size of 4.07 mm and 0.215 mm, respectively. A whole view reconstruction of the cylindrical target sample was performed, and the corresponding cylindricity and diameter deviation were assessed. The fluid media effect and the target surface quality effect were discussed.

3D surface imaging↗

Radiation image reconstruction and uncertainty quantification using a Gaussian process prior

We propose a complete framework for Bayesian image reconstruction and uncertainty quantification based on a Gaussian process prior (GPP) to overcome limitations of maximum likelihood expectation maximization (ML-EM) image reconstruction algorithm. The prior distribution is constructed with a zero-mean Gaussian process (GP) with a choice of a covariance function, and a link function is used to map the Gaussian process to an image. Unlike many other maximum a posteriori approaches, our method offers highly interpretable hyperparamters that are selected automatically with the empirical Bayes method. Furthermore, the GP covariance function can be modified to incorporate a priori structural priors, enabling multi-modality imaging or contextual data fusion. Lastly, we illustrate that our approach lends itself to Bayesian uncertainty quantification techniques, such as the preconditioned Crank–Nicolson method and the Laplace approximation. The proposed framework is general and can be employed in most radiation image reconstruction problems, and we demonstrate it with simulated free-moving single detector radiation source imaging scenarios. We compare the reconstruction results from GPP and ML-EM, and show that the proposed method can significantly improve the image quality over ML-EM, all the while providing greater understanding of the source distribution via the uncertainty quantification capability. Furthermore, significant improvement of the image quality by incorporating a structural prior is illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Optimizing transmit field inhomogeneity of parallel RF transmit design in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B+1) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B+1 field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient’s presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B+1 fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B+1 fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method’s advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Lu, Zhengyi [Vanderbilt University]↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗