Los Alamos National Laboratory designed a compact laser-induced fluorescence imaging camera with Raman spectrometer to identify organic molecules and biosignatures in environments such as Martian caves, icy-moons, and asteroid surfaces. OrganiCam is the primary instrument on the Laser-Induced Fluorescence Exploration of Caves for Organics and Volatiles using an Elevated Platform (LIFE COVE) NASA mission concept. OrganiCam could also determine if instruments being sent into space for NASA are sterile and analyze samples returned to Earth. OrganiCam’s robust design for extreme environments, portability, simple operation, and low power requirement build on LANL’s 50+ years designing robotic instruments for space applications.
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.
Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.
This dataset contains Leaf Area Index (LAI) measurements made as part of the Colorado Headwaters Ecological Spectroscopy Study (CHESS) during June and July of 2025. Data were collected in the Upper Gunnison Basin, Colorado, across three study domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). Field observations of LAI were collected within 72 hours of airborne data collection by the National Ecological Observatory Network’s Aerial Observation Platform (NEON AOP). The NEON AOP collected waveform LiDAR (Light Detection and Ranging) and imaging spectrometer data in 426 spectral bands from the visible to shortwave infrared. LAI measurements were collected using the LICOR LAI-2200C Plant Canopy Analyzer following protocols outlined in the instrument manual (LI-COR 2019). Sampling targeted four distinct vegetation types: meadows, shrubs, trees, and aspen forest understory. We have archived data separately by site type because different field methods were used for each. At meadow sites, measurements were made at the four corners of 1m x 1m plots, with the instrument moving inward toward the center of the plot. At shrub sites, we measured the canopies of individual shrubs. At tree sites, we made measurements within a 10m x 10m subplot centered around a focal tree, with 30 observations taken on a regular grid. At aspen understory sites, we measured overstory trees following the tree protocol and understory herbaceous vegetation following the meadow protocol. All measurements included above-canopy (A) and below-canopy (B) readings, with specific protocols for scattering correction measurements in direct-sun conditions. Data were processed using the R package `rlai` (Worsham 2025). This package includes functions to calculate LAI, gap fraction, apparent clumping factor (Ω), scattering correction, and other canopy metrics. Package contents: Full file descriptions appear in ‘flmd.csv’. Files named according to the convention ‘lai_*_summary_data_cleaned.csv’ contain summary values of LAI, apparent clumping factor (Ωapp), and scattering correction factors for each site. These are the analysis-ready products that most data users will work with. Files named ‘lai_*_metadata_cleaned.csv’ contain additional site-level observations made during field collection. We have also archived intermediate and supplementary data for users who wish to check our processing approach or apply alternative methods. ‘raw_lai_2200C.zip’ contains the raw files as read from the LI-COR instrument, with no processing applied, in TXT format. The zip archive contains subdirectories by site type, which are further subdivided by sampling area. Filenames correspond to the sampling site number. ‘intermediate_results.zip’ contains detailed output from the processing routines, in JSON format. The zip archive contains subdirectories by site type; filenames correspond to the sampling site number. ‘scattering_correction_logs.zip’ contains logfiles from the implementation of Kobayashi et al.'s (2013) scattering correction algorithm. The logfiles report values of several parameters at each iteration of the algorithm, as the model converges toward a stable solution. They are intended for users who want to verify scattering correction performance. The zip archive contains subdirectories by site type; filenames correspond to the sampling site number. ‘spot_checks.csv’ reports LAI and other values for a small number of files processed with LI-COR FV2200 software (LI-COR 2013) using the same control parameters as in our R-based approach. Additional metadata are provided in a data dictionary describing column names and definitions (dd.csv), and in a file-level metadata file (flmd.csv). All zip files can be expanded with common archive utilities. TXT, CSV, and JSON files can be ingested into R or Python computing environments or read in common text editor utilities. Geospatial information: Geospatial data for mapping measurement site locations are in the files CHESS_polygons_lai_UTM.geojson, CHESS_polygons_shrub_UTM.geojson, and CHESS_polygons_meadow_UTM.geojson in the companion geospatial package for the 2025 CHESS campaign, ‘CHESS 2025: Location data for field observations and sampling’ (Henderson et al., 2026). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. * Todorov and Worsham are co–first authors.
Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.
A coded aperture is used to demonstrate emission spectroscopy from multiple one-dimensional measurement locations simultaneously with a single camera. The coded aperture mask has several columns of periodic apertures, each with a unique spatial frequency. Light transmitted through all mask columns is detected through an imaging spectrometer. Dispersed light from the various mask columns overlaps on the spectrometer camera but is separated using Fourier-domain filtering using the known spatial frequencies of the mask. As the coded aperture is placed at an image plane, each Fourier-filtered spectrogram comes from a unique one-dimensional measurement location. This technique represents a significant increase in the amount of spatially and spectrally resolved emission data available using a single emission spectrometer and camera at the expense of some spatial resolution due to the Fourier filtering. This instrument is particularly useful for studying transient, non-repeating events. Megahertz-rate emission spectroscopy from five one-dimensional measurement locations is demonstrated with explosive fireballs using a single camera. Optical design parameters and instrument performance characteristics are discussed.
The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.
Characterization of the thermal gradients within supersonic and hypersonic flows is essential for understanding transition, turbulence, and aerodynamic heating. Developments in novel, impactful non-intrusive techniques are key for enabling flow characterizations of sufficient detail that provide experimental validation datasets for computational simulations. In this work, Resonantly Ionized Photoemission Thermometry (RIPT) signals are directly imaged using an ICCD camera to realize the techniques 1D measurement capability for the first time. The direct imaging scheme presented for oxygen-based RIPT (O 2 RIPT) uses the previously established calibration data to direct excite various resonant rotational peaks within the S-branch of the C 3 Π, ( v = 2) ← X 3 Σ( v ′ = 0) absorption band of O 2 . The efficient ionization of O 2 liberates electrons that induce electron avalanche ionization of local N 2 molecules generating N 2 + , which primarily deexcites via photoemissions of the first negative band of N 2 + ( B 2 Σ <#comment/> u + − <#comment/> X 2 Σ <#comment/> g + ) . When sufficient lasing energy is used, the ionization region and subsequent photoemission signal is achieved along a 1D line thus, if directly imaged can allow for gas temperature assignments along said line; demonstrated here of up to five centimeters in length. The temperature gradients present within the ensuing shock train of a supersonic under expanded free jet serves as a basis of characterization for this new RIPT imaging scheme. The O 2 RIPT results are extensively compared and validated against well-known and established techniques (i.e., CARS and CFD). The direct imaging capability fully realizes the technique’s fundamental potential and is expected to be the standard of implementation going forward. The direct imaging capability can play instrumental roles in future scientific studies that rely upon acute characterization of thermal gradients within a medium that cannot be easily resolved by a point. Furthermore, the removal of the spectrometer greatly reduces the cost, complexity, and optical alignment associated with prior RIPT measurements.
The Laser-Based X-ray Radiographic Imaging team at Los Alamos National Lab is looking for a monoenergetic MeV X-ray source to both verify our Monte Carlo N-particle simulations of detector performance and calibrate the instruments for future measurements. Funded by the Laboratory Directed Research and Development (LDRD) program, our overall goal is to improve the radiographic quality and reliability of laser-based X-ray sources for deployment at both dynamic and static radiography facilities. Laser-based X-ray sources have demonstrated smaller spot sizes to current electron accelerator based sources. The smaller laser spot size leads to significantly improved resolution.
The UV photochemistry of organic molecules is a fundamental process that governs reactions in the atmosphere, synthetic chemistry, processing of organic aerosols, and biological damage in living tissues. In many organic molecules, the ensuing evolution involves pathways that are in competition, giving rise to different products, isomerization, coupling to other electronic states, and secondary reactive collisions. Because photodissociation is usually fast (picoseconds to microseconds), these processes are far from equilibrium and are controlled by kinetic competition and dynamical forces. The work accomplished was focused primarily on the photochemistry of alpha-keto carboxylic acids, a group of acids produced from natural sources, which are implicated in aerosol formation and biological processes. In the atmosphere, they are destroyed mainly by solar radiation. Studying their photochemistry has been surprisingly difficult because of the complexity of their excited electronic states, and the effect of collisions and secondary reactions. The second project investigated the lifetime of excited electronic states of pyrazine and picoline and had both experimental and theoretical aspects. The work focused on a model molecule, pyruvic acid (PA), because it was hypothesized that it should be a good source of the unstable carbene, methylhydroxycarbene (MHC). PA has an internal hydrogen bond that controls the evolution of its decomposition. The decomposition was studied following excitation to two of its lowest excited states reached by laser irradiation at 351 and 193 nm. The photodissociation dynamics in the absence and presence of collisions was monitored and compared. Understanding the UV photochemistry requires the use of complementary experimental approaches. Two methods were enlisted, which together generated a comprehensive and detailed set of results: (i) The time-sliced velocity map imaging (SVMI) instrument at USC was exploited to determine kinetic energy release of fragments, fast dissociation timescales, and internal state distributions of fragments for which Resonance Enhanced Multiphoton Ionization (REMPI) schemes exist; and (ii) The multiplexed photoionization mass spectrometer (MPIMS) setup developed at the Sandia Combustion Research Facility was used for product discovery, achieved by exploiting tunable narrowband VUV radiation at the Advanced Light Source (ALS), and to follow in real time their subsequent unimolecular and bimolecular reactions. The experimental conditions ranged from collisionless molecular beams to study nascent products to flow reactors of variable pressures to study subsequent bimolecular reactions of the products. The goals stated above were successfully accomplished. By exciting PA to its lowest excited state, MHC was identified as the only primary product and its isomerization to vinylalcohol and acetaldehyde was directly observed in real time. Moreover, we reported the first bimolecular reaction of MHC, which was with acetaldehyde, and identified its reaction product. This paves the way for the study of other reactions of this important carbene intermediate. When excitation was carried out at 193 nm, which imparted much higher energy to PA, many more products were directly observed in real time, some deriving from three-body dissociation. Quantitative branching ratios and secondary reactions of radical products were also determined and analyzed. The studies of pyrazine and picoline focused on the second excited state of these molecules and showed (via ionization studies) that their excited states were very short lived (<100 fs) because of efficient couplings to lower electronic states via vibronic coupling. Theoretical work on modeling the absorption spectrum and decay mechanisms of the excited states are in progress in collaboration with theoreticians.
At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to semiconductor-based energy-dispersive detectors, but with better collection efficiency than wavelength-dispersive instruments, will enable greatly improved X-ray emission and absorption spectroscopic measurements. Additionally, a prototype instrument with 24 microwave-frequency multiplexed pixels is now in testing at the Advanced Photon Source (APS) 1-BM beamline. Initial measurements show an energy resolution ten times better (150 eV compared to < 15 eV) than the silicon-drift detectors currently available to APS beamline users, and in particular demonstrate the ability to resolve closely-spaced emission lines in samples containing multiple transition metal elements, such as integrated circuits. Comparing fluorescence spectra of integrated circuits measured with our TESs at the beamline to those measured with silicon detectors, we find emission lines and elements largely hidden (e.g. Hf alongside Cu) from a semiconductor-based detector but well resolved by a TES. This directly shows the strengths of TES-based instruments in fluorescence mapping.
Savannah River National Laboratory, and the larger community, has limited chemical-specific imaging capabilities, which would be beneficial for remote detection of threat chemicals or use in inaccessible and harsh environments, as well as in-line process monitoring. The project objective is to develop a novel, rugged, highly sensitive spectrometer to support real-time, chemically specific imaging using hyperspectral Raman spectroscopy.
We present spectroscopic data of strong lenses and their source galaxies using the Keck Near-Infrared Echellette Spectrometer (NIRES) and the Dark Energy Spectroscopic Instrument (DESI), providing redshifts necessary for nearly all strong-lensing applications with these systems, especially the extraction of physical parameters from lensing modeling. These strong lenses were found in the DESI Legacy Imaging Surveys using residual neural networks and followed up by our Hubble Space Telescope program, with all systems displaying unambiguous lensed arcs. With NIRES, we target eight lensed sources at redshifts difficult to measure in the optical range and determine the source redshifts for six, between z s = 1.675 and 3.332. DESI observed one of the remaining source redshifts, as well as an additional source redshift within the six systems. The two systems with nondetections by NIRES were observed for a considerably shorter 600 s at high airmass. Combining NIRES infrared spectroscopy with optical spectroscopy from our DESI Strong Lensing Secondary Target Program, these results provide the complete lens and source redshifts for six systems, a resource for refining automated strong lens searches in future deep- and wide-field imaging surveys and addressing a range of questions in astrophysics and cosmology.
Robot Nose will use new fast data throughput methods and experience with laser microfocus to dramatically improve the speed and spatial resolution of an established instrument, making it a useful tool for imaging special nuclear materials (SNM). Mass spectrometry imaging instruments have traditionally been too slow and mass alone is generally an insufficient measurement for organic analyses. This situation was markedly improved by Ionwerks Inc., who pioneered the combination of ion mobility with mass spectrometry imaging. In 2D mobility-mass plots, clearly identifiable trend lines can be selected and reduced to 1D mass spectra without isobaric interferences. This is a major advantage over other imaging mass spectrometers that generally cannot distinguish isobars without custom-built lasers or high voltage accelerators. Special nuclear material (SNM) contains substantial fissile isotopes, particularly 233U, 235U, and 239Pu. A complete forensic analysis of SNM therefore requires quantitative isotopic measurement – often through some form of mass spectrometry. SNM contaminated with inclusions such as pollen grains can help identify its prior locations. The project team is presently working on an approach to allow rapid screening of 1-3 cm diameter thin samples of such material.
The high-volume precipitation spectrometer (HVPS) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring hydrometeors larger than 150 μm. It is an open-path instrument located on the outside of the aircraft, typically below the wing. A laser sheet throws a shadowgraph image of the hydrometeor (cloud droplets or ice crystals) in the sample volume on a photodiode array. As the hydrometeor moves through the sample volume, this optical array records the moving shape and a two-dimensional picture can be recorded. At an air speed of 100 m/s, the sample volume is 310 l/s. The recorded images can be analyzed for size distributions, number concentrations, and further cloud properties detailed below. Hydrometeors in the range of 0.3-19.2 mm can be fully recorded at a 150 μm resolution; larger particles can only be sized along the direction of flight.
In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.
Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.