Search NASA⌕ Search

SEARCH · Search NASA

Results for “image velocimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Blood flow imaging by optimal matching of computational fluid dynamics to 4D-flow data

Three-dimensional, time-resolved blood flow measurement (4D-flow) is a powerful research and clinical tool, but improved resolution and scan times are needed. Therefore, this study aims to (1) present a postprocessing framework for optimization-driven simulation-based flow imaging, called 4D-flow High-resolution Imaging with a priori Knowledge Incorporating the Navier-Stokes equations and the discontinuous Galerkin method (4D-flow HIKING), (2) investigate the framework in synthetic tests, (3) perform phantom validation using laser particle imaging velocimetry, and (4) demonstrate the use of the framework in vivo. An optimizing computational fluid dynamics solver including adjoint-based optimization was developed to fit computational fluid dynamics solutions to 4D-flow data. Synthetic tests were performed in 2D, and phantom validation was performed with pulsatile flow. Reference velocity data were acquired using particle imaging velocimetry, and 4D-flow data were acquired at 1.5 T. In vivo testing was performed on intracranial arteries in a healthy volunteer at 7 T, with 2D flow as the reference. Results Synthetic tests showed low error (0.4%-0.7%). Phantom validation showed improved agreement with laser particle imaging velocimetry compared with input 4D-flow in the horizontal (mean -0.05 vs -1.11 cm/s, P < .001; SD 1.86 vs 4.26 cm/s, P < .001) and vertical directions (mean 0.05 vs -0.04 cm/s, P = .29; SD 1.36 vs 3.95 cm/s, P < .001). In vivo data show a reduction in flow rate error from 14% to 3.5%. Phantom and in vivo results from 4D-flow HIKING show promise for future applications with higher resolution, shorter scan times, and accurate quantification of physiological parameters.

4D-flow MRI↗

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Scale-Dependent Bedform Migration and Deformation in the Physical and Spectral Domains

Multi-scale bathymetries observed in laboratory channels and natural rivers have posed several challenges to the description of bedform geometry and kinematics. To better quantify scale-dependent migration velocity, high resolution spatio-temporal bed evolution data are analyzed using three independent methods: (i) a bedform tracking method that identifies individual bedforms in longitudinal bed elevation profiles, (ii) a cross-correlation based, image matching technique in consecutive bathymetry scans similar to Particle Image Velocimetry, and (iii) two-dimensional frequency-wavenumber spectra marking a dispersion relation between bedform period and length, allowing estimation of Fourier-based, scale-dependent migration velocities. The comparative studies show that the spectral and bedform tracking methods present small differences in the migration velocity of medium-large bedforms. However, significant deviations occur in the small bedforms, mostly due to bedform sheltering or amplified exposure to the flow, which also contribute to their enhanced scale-dependent deformation. The analysis also shows that some form of scale separation is needed to extract the large and slowly migrating bedforms as they are masked by secondary features when several bedform orders coexist. Bathymetric Image Velocimetry reasonably estimates the averaged migration velocity and exhibits potential to study relations between spanwise bed surface velocity and local bedform kinematics.

58 GEOSCIENCES↗

Pseudo-viscous modeling of transport in dense granular flows for thermal energy storage applications

Dense, granular flows were examined to effectively capture and model bulk viscous properties in thin packed beds. A modified Couette cell with particle image velocimetry was used to experimentally determine pseudo-viscosity properties of four particulate media with varying morphologies: (1) iron oxide-coated SiO 2 particles, (2) CARBOBEAD CP30-60 particles, (3) CARBOBEAD CP40-100 particles, and (4) Al 2 O 3 beads. The pseudo-viscosity functions were fitted using a power law to correlate the measured shear stress as a function of measured shear rate. The pseudo-viscous functions were used as inputs to computation fluid dynamics models for a single-phase viscous fluid to predict granular flow profiles. Steady-state free surface velocity profiles at angular velocities <7 rad/s predicted by the model were in good agreement with the experimental particle image velocimetry measurements, resulting in Pearson correlation coefficients of 0.97 for iron-oxide coated SiO 2 particles and 0.95 for CP30-60 particles. As a result, this alternative approach to measuring pseudo-viscous properties under shearing and modeling bulk transport behavior of granular flow using computation fluid dynamics model offered significant reduction in computational load compared to discrete element methods.

14 SOLAR ENERGY↗

High throughput automated characterization of enamel microstructure using synchrotron tomography and optical flow imaging

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Further, enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing.

36 MATERIALS SCIENCE↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

One-shot omnidirectional pressure integration through matrix inversion

In this work, we present a method to perform 2D and 3D omnidirectional pressure integration from velocity measurements with a single-iteration matrix inversion approach. This work builds upon our previous work, where the rotating parallel ray approach was extended to the limit of infinite rays by taking continuous projection integrals of the ray paths and recasting the problem as an iterative matrix inversion problem. This iterative matrix equation is now 'fast-forwarded' to the 'infinity' iteration, leading to a different matrix equation that can be solved in a single step, thereby presenting the same computational complexity as the Poisson equation. We observe computational speedups of ~10 6 when compared to brute-force omnidirectional integration methods, enabling the treatment of grids of ~10 9 points and potentially even larger in a desktop setup at the time of publication. Further examination of the boundary conditions of our one-shot method shows that omnidirectional pressure integration implements a boundary condition where the boundary points are treated as interior points to the extent that information is available. Finally, we show how the method can be extended from the regular grids typical of particle image velocimetry to the unstructured meshes characteristic of particle tracking velocimetry data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a coupled experimental–computational approach for engineering optimization of spout-fluidized bed particle coating systems

The design of spout-fluidized bed (SFB) coating systems for nuclear particle fuels typically relies on trial-and-error processes, comprising iterative and time-consuming coating deposition experiments and post-deposition characterization. At an engineering scale, this approach to guided SFB system design is inefficient, highlighting the need for streamlined experimental methodologies which can correlate fluidization conditions to downstream coating outcomes. In this study, we combine time-resolved particle image velocimetry (PIV) with CFD–DEM simulations to benchmark hydrodynamic behavior in a 3D spout-fluidized bed. By exploiting easily accessible optical measurements of particle motion at the bed wall and within the spouting region, we obtain quantitative velocity fields that can be directly compared with model predictions of the occluded bed region, without resorting to complex imaging and characterization techniques such as X-ray or magnetic resonance tomography. Experimental benchmarking reveals strong agreement between CFD–DEM and PIV in the spout and annulus regions, while discrepancies near the wall highlight areas for future model development. Here, the proposed integrated experimental–numerical framework will enable a direct connection between measured variables and numerically predicted fluidization performance of dense, surrogate nuclear particle fuel feedstock such that experimental SFB component design can be rapidly evaluated, informing design decisions for nozzle geometry and operating conditions. Future work will extend this framework by correlating quantified fluidization metrics across nozzle geometries and operating conditions with the resulting coating morphology, microstructure, and uniformity. Establishing these correlations will enable predictive links between hydrodynamic performance and coating quality, providing a rational, scalable basis for optimizing SFB design prior to coating deposition.

CFD/DEM↗

Dam-Break Flow Measurements of Liquid–Granular Mixtures in a Channelized Reservoir

Dam-break flows of granular materials exhibit a complex non-Newtonian rheology, which is strongly influenced by various factors, such as the characteristics of the granular material, the degree of initial compaction, and saturation level of the granular matrix. Specially adapted nonintrusive techniques are required to investigate these flows in the laboratory. This paper investigated the nonintrusive technique of image analysis. The methodologies used in the measurement of bulk flow parameters, such as flow depth, front velocity, and flow rate, and the extraction of detailed flow characteristics such as velocity profiles, were discussed in the context of a series of granular dam-break flow experiments. These experiments were performed under three types of initial conditions: dry, saturated (water filling the pore space), and submerged (a layer of saturated granular material submerged under water) using four types of granular materials—PET pellets, crushed walnut shells, urea, and sand—with grain sizes ranging from 200 μm to 2.9 mm. High-speed cameras were used to capture the evolution and local properties of the flow, such as velocity fields using particle image velocimetry (PIV). Bulk properties of the flow were obtained by tracking the surface profile of the granular matrix and the water table. The extracted profiles were used to measure the evolution of the volume of the granular matrix and the fluid phase separately upstream and downstream of the gate, which allowed measuring the dilatancy (increase in pore space). The study showed that the image analysis techniques are versatile and can be adapted to measure different flow parameters in a variety of granular flows to better understand and analyze their complex behavior. Finally, the advantages and drawbacks of each image analysis technique were discussed and best-practice recommendations were provided.

42 ENGINEERING↗

Vortex rings drive entrainment and cooling in flow induced by a spark discharge

Spark plasma discharges induce vortex rings and a hot gas kernel. We develop a model to describe the late stage of the spark-induced flow and the role of the vortex rings in the entrainment of cold ambient gas and the cooling of the hot gas kernel. The model is tested in a plasma-induced flow using density and velocity measurements obtained from simultaneous stereoscopic particle image velocimetry and background oriented schlieren. We show that the spatial distribution of the hot kernel follows the motion of the vortex rings, whose radial expansion increases with the electrical energy deposited during the spark discharge. Here, the vortex ring cooling model establishes that entrainment in the convective cooling regime is induced by the vortex rings and governs the cooling of the hot gas kernel, and the rate of cooling increases with the electrical energy deposited during the spark discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aluminum-doped calcium manganite particles for solar thermochemical energy storage: Reactor design, particle characterization, and heat and mass transfer modeling

A two-step cycle is discussed for solar thermochemical energy storage based on particulate aluminum-doped calcium manganite reduction/oxidation reactions for direct integration into Air Brayton cycles. The two steps encompass 1) the storage of concentrated solar irradiation within endothermic reduction of aluminum-doped calcium manganite and 2) the delivery of heat to an Air-Brayton cycle via exothermic re-oxidation of oxygen-deficient aluminum-doped calcium magnanite. A 5 kW th scale solar thermochemical reactor operating under vacuum was designed, modeled, and optimized to thermally reduce a continuous, gravity-driven flow of aluminum-doped calcium manganite particles. The granular flows were characterized in a tilt-flow rig, and particle image velocimetry was used to determine flow properties via frictional and velocity scaling relationships. Flow properties were integrated into a detailed heat and mass transfer model of the solar thermochemical reactor. A reactor design with 31° inclination angle, 230 g/min of particles, and 5.2 kW th radiative input from the high-flux solar simulator was discovered to produce an outlet flow temperature of 1158 K, with stoichiometric deviations of 0.076 and a storage efficiency of 0.628 while avoiding particle overheating and promoting longer particle residence times.

14 SOLAR ENERGY↗

High-Fidelity Velocity and Concentration Measurements of Turbulent Buoyant Jets

Accurate models of turbulent buoyant flows are essential for the design of the cooling circuit of nuclear reactors and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We analyze experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous particle image velocimetry and laser-induced fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The refractive index matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy-driven flows (e.g. natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in a uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as a basis for the development of a new model that captures turbulent mixing.

laser induced fluorescence↗

Experimental measurements of fluid flow in an 84-pin hexagonal rod bundle with spacer grid for a gas-cooled fast modular reactor

A 50 MW e helium-cooled fast modular reactor (FMR) is under development, and as part of the Department of Energy Integrated Research Project (IRP), Texas A&M University is conducting the thermal-hydraulic characterization of its baseline core configuration. Here, we experimentally investigated the axial and cross flow fields characteristics in the hexagonal fuel rod bundle composed of 84 rods, a central rod, and spacer grids at a Reynolds number of 12,000. A fully transparent experimental facility resembling of one unit of the fuel assembly was constructed. Time-resolved particle image velocimetry (TR-PIV) measurements were performed to characterize hydraulic behavior downstream the spacer grid. Velocity measurements were conducted in the axial and radial direction of the rod bundle. From the PIV velocity vector fields, the full-field flow statistics were computed for the mean velocity, vorticity, and Reynolds stresses. An analysis of the energy decay downstream of the spacer grid was conducted with calculations of secondary-flow intensities, turbulent kinetic energy, power spectrum, and spatial-temporal velocity cross correlations. The vorticity field was obtained and pairs of counter-rotating vortexes were identified using a 3D reconstruction of several measurement planes. The data from this experimental campaign will be used to validate numerical models based on Computational Fluid Dynamics and other codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of Calibrated k–ε Model Parameters for Jet-in-Crossflow

Previous efforts determined a set of calibrated, optimal model parameter values for Reynolds-averaged Navier–Stokes (RANS) simulations of a compressible jet in crossflow (JIC) using a $k–ε$ turbulence model. These parameters were derived by comparing simulation results to particle image velocimetry (PIV) data of a complementary JIC experiment under a limited set of flow conditions. Here, a $k–ε$ model using both nominal and calibrated parameters is validated against PIV data acquired from a much wider variety of JIC cases, including a realistic flight vehicle. The results from the simulations using the calibrated model parameters showed considerable improvements over those using the nominal values, even for cases that were not used in the calibration procedure that defined the optimal parameters. This improvement is demonstrated using a number of quality metrics that test the spatial alignment of the jet core, the magnitudes of multiple flow variables, and the location and strengths of vortices in the counter-rotating vortex cores on the PIV planes. These results suggest that the calibrated parameters have applicability well outside the specific flow case used in defining them and that with the right model parameters, RANS solutions for the JIC can be improved significantly over those obtained from the nominal model.

42 ENGINEERING↗

Linking spout fluidization hydrodynamics to pyrolytic carbon deposition characteristics in a fluidized bed chemical vapor deposition reactor

Spout fluidized bed chemical vapor deposition (SFB-CVD) is the dominant method for producing pyrolytic carbon (PyC) coatings on tristructural-isotropic (TRISO) fuel particles, yet the relationship between gas injector design, fluidization hydrodynamics, and resulting coating quality remains poorly quantified. Here, in this work, three spout fluidized bed (SFB) nozzle geometries were designed and fabricated to empirically investigate how injector-driven changes in particle circulation influence PyC deposition. The geometries were first evaluated in a room temperature fluidization apparatus using time-resolved particle image velocimetry, which highlighted distinct differences in particle velocity fields, circulation pathways, and overall fluidization quality. Graphite versions of each injector geometry were subsequently implemented in a laboratory-scale SFB-CVD reactor to deposit PyC onto surrogate fuel kernels under similar conditions. Post-deposition characterization included particle morphology, coating thickness, porosity distribution, optical anisotropy, and microindentation mechanical testing. Overall, the results show clear differences in coating microstructure as a function of changing injector geometry, despite mechanical testing indicating comparable elastic modulus values across all coatings. This study provides one of the first fully experimental, quantitative mappings between SFB nozzle geometry, fluidization hydrodynamics, and resulting PyC coating structure. The framework established here supports rational injector design and offers a pathway toward improved coating control in future pilot- and production-scale TRISO fuel fabrication systems.

Coated particle fuel↗

Quantifying particle movement in a spout-fluidized bed with irregular feedstock morphology

Here, the spout-bed fluidization behavior of nonspherical, 140 μm SiC feedstock was quantified via particle image velocimetry for varying gas distributor geometries. A bench-scale, room-temperature fluidization setup was assembled to model a 50 mm fluidized bed chemical vapor deposition (FB-CVD) system, and fluidized bed motion was captured using a high-speed camera. Modular tips with varying inlet geometries were 3D printed and tested on the bench-scale rig using identical feedstock and gas flow rates in the range of 3.0–9.0 L/min. Fluidization behavior was quantified by extracting parameters of the bed velocity, frequency, dead time, and other measurements, which were ranked for each inlet geometry configuration tested. The results from this work demonstrate that changing the path of inlet gas flow can significantly change the hydrodynamics within a spout-fluidized bed under identical feedstock, loading, and flow rate conditions, potentially enabling experimental control of particle fluidization behavior for a given condition. Moreover, composite rankings of fluidization behavior for unique distributor geometries hold potential to guide the design of FB-CVD experiments for various engineering and scientific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗