Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fully Integrated Ultra-thin Intraoperative Micro-imager for Cancer Detection Using Upconverting Nanoparticles

Abstract Purpose Intraoperative detection and removal of microscopic residual disease (MRD) remain critical to the outcome of cancer surgeries. Today’s minimally invasive surgical procedures require miniaturization and surgical integration of highly sensitive imagers to seamlessly integrate into the modern clinical workflow. However, current intraoperative imagers remain cumbersome and still heavily dependent on large lenses and rigid filters, precluding further miniaturization and integration into surgical tools. Procedures We have successfully engineered a chip-scale intraoperative micro-imager array—without optical filters or lenses—integrated with lanthanide-based alloyed upconverting nanoparticles (aUCNPs) to achieve tissue imaging using a single micro-chip. This imaging platform is able to leverage the unique optical properties of aUCNPs (long luminescent lifetime, high-efficiency upconversion, no photobleaching) by utilizing a time-resolved imaging method to acquire images using a 36-by-80-pixel, 2.3 mm $$\times$$ × 4.8 mm silicon-based electronic imager micro-chip, that is, less than 100-µm thin. Each pixel incorporates a novel architecture enabling automated background measurement and cancellation. We have validated the performance, spatial resolution, and the background cancellation scheme of the imaging platform, using resolution test targets and mouse prostate tumor sample intratumorally injected with aUCNPs. To demonstrate the ability to image MRD, or tumor margins, we evaluated the imaging platform in visualizing a single-cell thin section of the injected prostate tumor sample. Results Tested on USAF resolution targets, the imager is able to achieve a resolution of 71 µm. We have also demonstrated successful background cancellation, achieving a signal-to-background ratio of 8 when performing ex vivo imaging on aUCNP-injected prostate tumor sample, improved from originally 0.4. The performance of the imaging platform on single-cell layer sections was also evaluated and the sensor achieved a signal-to-background ratio of 4.3 in resolving cell clusters with sizes as low as 200 cells. Conclusion The imaging system proposed here is a scalable chip-scale ultra-thin alternative for bulky conventional intraoperative imagers. Its novel pixel architecture and background correction scheme enable visualization of microscopic-scale residual disease while remaining completely free of lenses and filters, achieving an ultra-miniaturized form factor—critical for intraoperative settings.

59 BASIC BIOLOGICAL SCIENCES↗

Tunable coherent light filter for optical sensing and imaging

Systems and methods are provided for filtering coherent infrared light from a thermal background for protection of infrared (IR) imaging arrays and detection systems. A Michelson interferometer is used for coherent light filtering. In an implementation, a system includes a fixed mirror, a beam splitter, and a moving mirror which can be controlled translationally, as well as tip/tilt. The Michelson interferometer may be used as an imaging system. For imaging applications, a system may comprise a tunable array of micro-electromechanical systems (MEMS) mirrors. A mid-wave IR interferometer with electronic feedback and MEMS mirror array is provided.

Wasserman, David↗

Meta-optics-based systems and methods for ocular applications

Meta-lens based ocular imaging, near-eye display, and eye-tracking systems are described. The systems can include a single focusing optic and an integrated circuit that provides illumination light and includes an imaging array. The focusing optic includes meta-atoms formed on a substrate. The systems may have no moving parts and achieve imaging or image-projection fields-of-view approaching or exceeding 180 degrees. Because of their low part count, the systems can be robust and have a very small form factor.

Hu, Juejun↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

The Illumination of Thunderclouds by Lightning: 4. Volumetric Thunderstorm Imagery

Optical instruments such as the Geostationary Lightning Mapper (GLM) detect lightning based on transient changes in cloud illumination. The horizontal location of lightning is determined from the coordinates of the pixels on the imaging array illuminated during the flash. However, the vertical position of the lightning pulses (approximated by GLM “groups”) below the cloud top cannot be routinely measured from a single space-based instrument. In our prior work, we have developed a machine learning algorithm that can infer optical source altitude for a given pulse based on how the optical energy is distributed across the group footprint and the local Advanced Baseline Imager Cloud-Top Height (CTH). In this fourth part of our thundercloud illumination study, we leverage these source altitudes to generate volumetric GLM imagery of a Colombia thunderstorm. We find that 3D versions of the current GLM meteorological imagery products (that describe thunderstorm kinematics) and thundercloud imagery products (that depict how the flashes appear from space) provide additional insights into lightning activity in the thunderstorm that are lost in the vertical integration used to generate the current 2D GLM gridded products. This new volumetric imaging capability provides a more comprehensive picture of where lightning occurs in the storm, how its physical characteristics vary across three-dimensional space, and how its optical emissions interact with surrounding the cloud medium.

54 ENVIRONMENTAL SCIENCES↗

Design of the high-yield time-gated x-ray hot-spot imager for OMEGA

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester’s OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium–tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick–Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 10 14 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 μm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal–oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. As a result, the technical design space for the instrument will be discussed and the conceptual design will be presented.

47 OTHER INSTRUMENTATION↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Retina-inspired narrowband perovskite sensor array for panchromatic imaging

The retina is the essential part of the human visual system that receives light, converts it to neural signal, and transmits to brain for visual recognition. The red, green, and blue (R/G/B) cone retina cells are natural narrowband photodetectors (PDs) sensitive to R/G/B lights. Connecting with these cone cells, a multilayer neuro-network in the retina provides neuromorphic preprocessing before transmitting to brain. Inspired by this sophistication, we develop the narrowband (NB) imaging sensor combining R/G/B perovskite NB sensor array (mimicking the R/G/B photoreceptors) with a neuromorphic algorithm (mimicking the intermediate neural network) for high-fidelity panchromatic imaging. Compared to commercial sensors, we use perovskite “intrinsic” NB PD to exempt the complex optical filter array. In addition, we use an asymmetric device configuration to collect photocurrent without external bias, enabling a power-free photodetection feature. These results display a promising design for efficient and intelligent panchromatic imaging.

42 ENGINEERING↗

Geranium Photodiodes for Hard Xray Detection

This report summarizes the investigations engaged at UC Davis under subcontract B632083, as related to the LLNL-LDRD Project “High-Speed X-Ray Imager Arrays.” The first section entails work done within the Electrical and Computer Engineering (ECE) Department. The purpose of the work done so far is to understand photodiode design and which parameters are conducive to the design goals, which are: I: Maximize the detector quantum efficiency. The device must have a quantum efficiency of roughly 5% at 80 keV. II: Minimize temporal response. Collection time is limited to 1ns. All charge must be collected in that time. III: Minimize dark current. In this document, various photodiode parameters and designs are explored, and their impact on these goals are tabulated. In addition to these, various instruments that have been constructed for either testing these parameters or helping teammates with their experiments. The second section entails work done with the Materials Science Engineering (MSE) Department. In accordance with the proposed development of the germanium ROIC backside imagers, a critical step in the micromachining of these devices was the removal of the substrate on which the PIN junctions were epitaxially grown. A common technique for the micromachining of silicon wafers is the use of chemical etching alongside an “etch-stop” layer. In this technique, a chemical etchant will remove material until it reaches the etch-stop layer, at which the etch rate will drop significantly. This high selectivity (ratio of etch rates) allows any unevenness in the initial etching to be effectively smoothed away in the event that part of the wafer surface reaches the etch-stop layer sooner than another. An initial literature review found a paper by Divan et al. in which the authors used ion implantation to dope germanium wafers and achieve selectivity on the order of 100, sufficient for a reliable etch-stop.

42 ENGINEERING↗

Wide Dust Gaps in Protoplanetary Disks Induced by Eccentric Planets: A Mass-eccentricity Degeneracy

The tidal perturbation of embedded protoplanets on their natal disks has been widely attributed to be the cause of gap-ring structures in submillimeter images of protoplanetary disks around T Tauri stars. Numerical simulations of this process have been used to propose scaling of characteristic dust-gap width/gap-ring distance with respect to planet mass. Applying such scaling to analyze observed gap samples yields a continuous mass distribution for a rich population of hypothetical planets in the range of several Earth to Jupiter masses. In contrast, the conventional core-accretion scenario of planet formation predicts a bimodal mass function due to (1) the onset of runaway gas accretion above ~20 Earth masses and (2) suppression of accretion induced by gap opening. Here, we examine the dust disk response to the tidal perturbation of eccentric planets as a possible resolution of this paradox. Based on simulated gas and dust distributions, we show the gap-ring separation of Neptune-mass planets with small eccentricities might become comparable to that induced by Saturn-mass planets on circular orbits. Furthermore, this degeneracy may obliterate the discrepancy between the theoretical bimodal mass distribution and the observed continuous gap width distribution. Despite damping due to planet–disk interaction, modest eccentricity may be sustained either in the outer regions of relatively thick disks or through resonant excitation among multiple super Earths. Moreover, the ring-like dust distribution induced by planets with small eccentricities is axisymmetric even in low viscosity environments, consistent with the paucity of vortices in Atacama Large Millimeter/submillimeter Array images.

79 ASTRONOMY AND ASTROPHYSICS↗

Holes in Optical Lightning Flashes: Identifying Poorly Transmissive Clouds in Lightning Imager Data

Space-based optical lightning sensors including the lightning imaging sensor (LIS) and geostationary lightning mapper (GLM) are pixelated imagers that detect lightning as transient increases in cloud top illumination. Detection requires optical emissions to escape the cloud top to space with sufficient energy to trigger a pixel on the imaging array. Through scattering and absorption, certain clouds are able to block most light from reaching the instrument, causing a reduction in detection efficiency (DE) and possibly location accuracy (LA). Radiant lightning emissions that illuminate large cloud top areas are used to examine scenarios where clouds block light from reaching orbit. In some cases, these anomalies in the spatial radiance distribution from the lightning pulse lead to “holes” in the optical lightning flash where certain pixels fail to trigger. Such holes are identified algorithmically in the Tropical Rainfall Measuring Mission satellite LIS record and the microphysical properties of the coincident storm region are queried. We find that holes primarily occur in tall (IR T b < 235 K) convection (87%) and overhanging anvil clouds (10%). The remaining 3% of holes occur in moderate-to-weak convection or in clear air breaks between stormclouds. We further demonstrate how an algorithm that assesses the spatial radiance patterns from energetic lightning pulses might be used to construct an optical transmission gridded stoplight product for GLM that could help operators identify clouds with a potentially reduced DE and LA.

54 ENVIRONMENTAL SCIENCES↗

The Illumination of Thunderclouds by Lightning: 2. The Effect of GLM Instrument Threshold on Detection and Clustering

Abstract Lightning is measured from space using optical instruments that detect transient changes in the illumination of the cloud top. How much of the flash (if any) is recorded by the instrument depends on the instrument detection threshold. NOAA's Geostationary Lightning Mapper (GLM) employs a dynamic threshold that varies across the imaging array and changes over time. This causes flashes in certain regions and at night to be recorded in greater detail than other flashes, and threshold inconsistencies will impose biases on all levels of GLM data products. In this study, we quantify the impact of the varying GLM threshold on event/group/flash detection, flash clustering, and gridded product generation by imposing artificial thresholds on the event data taken from a thunderstorm with a low instrument threshold (∼0.7 fJ). We find that even modest increases in threshold severely impact event (60% loss by 2 fJ, 90% loss by 10 fJ) and group (25% loss by 2 fJ, 81% loss by 10 fJ) detection by suppressing faint illumination of the cloud top from weak sources and scattering. Flash detection is impacted less by threshold increases (4% loss by 2 fJ), but reductions are still significant at higher thresholds (35% loss by 10 fJ, or 44% if single‐group flashes are removed). Undetected pulses cause individual flashes to be split and severely impact the construction of gridded products. All of these factors complicate the interpretation of GLM data, particularly when trended over time under a changing threshold.

54 ENVIRONMENTAL SCIENCES↗

The Illumination of Thunderclouds by Lightning: 3. Retrieving Optical Source Altitude

Abstract Optical space‐based lightning sensors such as the Geostationary Lightning Mapper (GLM) detect and geolocate lightning by recording rapid changes in cloud top illumination. While lightning locations can be determined to within a pixel on the GLM imaging array, these instruments are not individually able to natively report lightning altitude. It has previously been shown that thunderclouds are illuminated differently based on the altitude of the optical source. In this study, we examine how altitude information can be extracted from the spatial distributions of GLM energy recorded from each optical pulse. We match GLM “groups” with Lightning Mapping Array (LMA) source data that accurately report the 3‐D positions of coincident Radio‐Frequency (RF) emitters. We then use machine learning methods to predict the mean LMA source altitudes matched to GLM groups using metrics from the optical data that describe the amplitude, breadth, and texture of the group spatial energy distribution. The resulting model can predict the LMA mean source altitude from GLM group data with a median absolute error of <1.5 km, which is sufficient to determine the location of the charge layer where the optical energy originated. This model is able to capture changes to the source altitude distribution in response to convective processes in the thunderstorm, and the GLM predictions can reveal the vertical structure of individual flashes ‐ enabling 3‐D flash geolocation with GLM for the first time. Future work will account for differences in thunderstorm charge/precipitation structures and viewing angle across the GLM Field of View.

54 ENVIRONMENTAL SCIENCES↗

Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths

Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.

Sun, K. -X. (ORCID:0000000224659235)↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Astrometric gravitational-wave detection via stellar interferometry

Here, we evaluate the potential for gravitational-wave (GW) detection in the frequency band from 10 nHz to 1 μ Hz using extremely high-precision astrometry of a small number of stars. In particular, we argue that nonmagnetic, photometrically stable, hot white dwarfs (WD) located at ~kpc distances may be optimal targets for this approach. Previous studies of astrometric GW detection have focused on the potential for less precise surveys of large numbers of stars; our work provides an alternative optimization approach to this problem. Interesting GW sources in this band are expected at characteristic strains around h c ~10 -17 × (μHz/ $f$ GW ). The astrometric angular precision required to see these sources is Δθ~h c after integrating for a time T~1/$f$GW. We show that jitter in the photometric center of WD of this type due to starspots is bounded to be small enough to permit this high-precision, small-N approach. We discuss possible noise arising from stellar reflex motion induced by orbiting objects and show how it can be mitigated. The only plausible technology able to achieve the requisite astrometric precision is a space-based stellar interferometer. Such a future mission with few-meter-scale collecting dishes and baselines of $\mathscr{O}$(100 km ) is sufficient to achieve the target precision. This collector size is broadly in line with the collectors proposed for some formation-flown, space-based astrometer or optical synthetic-aperture imaging-array concepts proposed for other science reasons. The proposed baseline is however somewhat larger than the km-scale baselines discussed for those concepts, but we see no fundamental technical obstacle to utilizing such baselines. A mission of this type thus also holds the promise of being one of the few ways to access interesting GW sources in this band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Power, Radiation Resilient Synchronous Edge Processing for Remote Monitoring

Next-generation space remote sensing systems may be equipped with imaging arrays that sense data at a rate that outstrips the processing capability of any computing hardware that can operate within a satellite’s power budget. This project developed novel convolutional and recurrent neural networks to detect and estimate point-like events amid clutter, and investigated their efficient and accurate implementation on analog in-memory computing systems that are 10-1000× more energy-efficient than digital processors. This project leveraged two memory devices at different levels of technological maturity: a large-scale analog computing prototype using commercial SONOS charge-trap memory, and electrochemical memory (ECRAM) with intrinsic radiation hardness. We experimentally demonstrated end-to-end analog processing of our neural networks on SONOS and characterized the radiation response of both SONOS and ECRAM. We advanced the state-of-the-art in ECRAM precision and reliability, and developed co-design methods to enable accurate long-term operation of SONOS analog accelerators in space radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗