Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging inverse problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Generalized Uncertainty Quantification for Linear Inverse Problems in X-ray Imaging

In industrial and engineering applications, X-ray radiography has attained wide use as a data collection protocol for the assessment of material properties in cases where direct observation is not possible. The direct measurement of nuclear materials, particularly when they are under explosive or implosive loading, is not feasible, and radiography can serve as a useful tool for obtaining indirect measurements. In such experiments, high energy X-rays are pulsed through a scene containing material of interest, and a detector records a radiograph by measuring the radiation that is not attenuated in the scene. One approach to the analysis of these radiographs is to model the imaging system as an operator that acts upon the object being imaged to produce a radiograph. In this model, the goal is to solve an inverse problem to reconstruct the values of interest in the object, which are typically material properties such as density or areal density. The primary objective in this work is to provide quantitative solutions with uncertainty estimates for three separate applications in X-ray radiography: deconvolution, Abel inversion, and radiation spot shape reconstruction. For each problem, we introduce a new hierarchical Bayesian model for determining a posterior distribution on the unknowns and develop efficient Markov chain Monte Carlo (MCMC) methods for sampling from the posterior. A Poisson likelihood, based on a noise model for photon counts at the detector, is combined with a prior tailored to each application: an edge-localizing prior for deconvolution; a smoothing prior with non-negativity constraints for spot reconstruction; and a full covariance sampling prior based on a Wishart hyperprior for Abel inversion. After developing our methods in a general setting, we demonstrate each model on both synthetically generated datasets, including those from a well known radiation transport code, and real high energy radiographs taken at two U. S. Department of Energy laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Random Walks With Tweedie: A Unified View of Score-Based Diffusion Models [In the Spotlight]

We present a concise derivation for several influential score-based diffusion models that relies on only a few textbook results. Diffusion models have recently emerged as powerful tools for generating realistic, synthetic signals—particularly natural images—and often play a role in state-of-the-art algorithms for inverse problems in image processing. While these algorithms are often surprisingly simple, the theory behind them is not, and multiple complex theoretical justifications exist in the literature. Here, in this study, we provide a simple and largely self-contained theoretical justification for score-based diffusion models that is targeted towards the signal processing community. This approach leads to generic algorithmic templates for training and generating samples with diffusion models. We show that several influential diffusion models correspond to particular choices within these templates and demonstrate that alternative, more straightforward algorithmic choices can provide comparable results. This approach has the added benefit of enabling conditional sampling without any likelihood approximation.

97 MATHEMATICS AND COMPUTING↗

MimicGAN: Robust Projection onto Image Manifolds with Corruption Mimicking

In the past few years, Generative Adversarial Networks (GANs) have dramatically advanced our ability to represent and parameterize high-dimensional, non-linear image manifolds. As a result, they have been widely adopted across a variety of applications, ranging from challenging inverse problems like image completion, to problems such as anomaly detection and adversarial defense. A recurring theme in many of these applications is the notion of projecting an image observation onto the manifold that is inferred by the generator. In this context, Projected Gradient Descent (PGD) has been the most popular approach, which essentially optimizes for a latent vector that minimizes the discrepancy between a generated image and the given observation. However, PGD is a brittle optimization technique that fails to identify the right projection (or latent vector) when the observation is corrupted, or perturbed even by a small amount. Such corruptions are common in the real world, for example images in the wild come with unknown crops, rotations, missing pixels, or other kinds of non-linear distributional shifts which break current encoding methods, rendering downstream applications unusable. To address this, we propose corruption mimicking—a new robust projection technique, that utilizes a surrogate network to approximate the unknown corruption directly at test time, without the need for additional supervision or data augmentation. The proposed method is significantly more robust than PGD and other competing methods under a wide variety of corruptions, thereby enabling a more effective use of GANs in real-world applications. Finally, more importantly, we show that our approach produces state-of-the-art performance in several GAN-based applications—anomaly detection, domain adaptation, and adversarial defense, that benefit from an accurate projection.

97 MATHEMATICS AND COMPUTING↗

Imaging in Diagnostic Nuclear Medicine

Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are modern methods for visualization in diagnostic nuclear medicine. SPECT is known as a workhorse in cardiology, and PET is the gold standard in oncology. The development of nuclear medicine is provided by cooperation of physicists, mathematicians, biologists, medical doctors, and radio-chemists. In spite of extensive clinical applications, several problems may lead to false diagnoses. In particular, the correction of attenuation of gamma radiation in human organs must be taken into account. For interpretation and evaluation of such an effect on the clinical results, we perform physico-mathematical simulation of the SPECT diagnostics in cardiology in the absence and presence of the correction of attenuation. A brief review of the state-of-the art is presented. The simulation employs the first Russian anthropomorphic mathematical phantom that describes the distribution of radio-pharmacological agent ({sup 99m }Tc-methoxyisobutylisonitrile) in chest organs of a typical male patient. A model for calculation of raw images is developed with allowance for attenuation of radiation in biological tissues and the effect of collimator and detector. The results of the proposed models and calculated images are compared with clinical images obtained at the Meshalkin Institute of Circulation Pathology (Novosibirsk) and Myasnikov Institute of Clinical Cardiology (Moscow). Statistical algorithms are developed for the solution of the inverse problem of image reconstruction based on the entropy principle. The clinical and physico-mathematical approaches are compared in the evaluation of the effect of correction on the quality of reconstructed images of the left ventricle of myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗

Multigrid Optimization for Large-Scale Ptychographic Phase Retrieval

Ptychography is a popular imaging technique that combines diffractive imaging with scanning microscopy. The technique consists of a coherent beam that is scanned across an object in a series of overlapping positions, leading to reliable and improved reconstructions. Ptychographic microscopes allow for large fields to be imaged at high resolution at the cost of additional computational expense. Herein, we propose a multigrid-based optimization framework to reduce the computational burdens of large-scale ptychographic phase retrieval. Our proposed method exploits the inherent hierarchical structures in ptychography through tailored restriction and prolongation operators for the object and data domains. Our numerical results show that our proposed scheme accelerates the convergence of its underlying solver and outperforms the ptychographical iterative engine, a workhorse in the optics community.

97 MATHEMATICS AND COMPUTING↗

Uncertainty quantification for inverse problems with application to ptychographic reconstruction

Inverse problems in imaging are commonly solved by optimization or learned surrogates that return a single reconstruction, while uncertainty information is often unavailable. In many experimental settings, however, uncertainty is required to assess reliability, guide downstream analysis, and prioritize additional measurements. In this note, we present a compact uncertainty-quantification framework based on local objective curvature, and then specialize it to ptychographic reconstruction. We further show how repeated reconstructions can be aggregated in a statistically principled way, including a practical implementation path for PtychoNN.

97 MATHEMATICS AND COMPUTING↗

Hyperspectral image reconstruction for x-ray fluorescence tomography

A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

Fluorescence microscopy↗

Scientific Computational Imaging Code (SCICO)

Scientific Computational Imaging Code (SCICO) is a Python package for solving the inverse problems that arise in scientific imaging applications. Its primary focus is providing methods for solving ill-posed inverse problems by using an appropriate prior model of the reconstruction space. SCICO includes a growing suite of operators, cost functionals, regularizers, and optimization routines that may be combined to solve a wide range of problems, and is designed so that it is easy to add new building blocks. SCICO is built on top of JAX rather than NumPy, enabling GPU/TPU acceleration, just-in-time compilation, and automatic gradient functionality, which is used to automatically compute the adjoints of linear operators. An example of how to solve a multi-channel tomography problem with SCICO is shown in Figure 1. The SCICO source code is available from GitHub, and pre-built packages are available from PyPI. It has extensive online documentation, including API documentation and usage examples, which can be run online at Google Colab and binder.

97 MATHEMATICS AND COMPUTING↗

Integrated Biophysical Modeling and Image Analysis: Application to Neuro-Oncology

Central nervous system (CNS) tumors come with vastly heterogeneous histologic, molecular, and radiographic landscapes, rendering their precise characterization challenging. The rapidly growing fields of biophysical modeling and radiomics have shown promise in better characterizing the molecular, spatial, and temporal heterogeneity of tumors. Integrative analysis of CNS tumors, including clinically acquired multi-parametric magnetic resonance imaging (mpMRI) and the inverse problem of calibrating biophysical models to mpMRI data, assists in identifying macroscopic quantifiable tumor patterns of invasion and proliferation, potentially leading to improved (a) detection/segmentation of tumor subregions and (b) computer-aided diagnostic/prognostic/predictive modeling. This article presents a summary of (a) biophysical growth modeling and simulation,(b) inverse problems for model calibration, (c) these models' integration with imaging workflows, and (d) their application to clinically relevant studies. We anticipate that such quantitative integrative analysis may even be beneficial in a future revision of the World Health Organization (WHO) classification for CNS tumors, ultimately improving patient survival prospects.

60 APPLIED LIFE SCIENCES↗

A Novel Gradient Projection Approach for Fourier-Based Image Restoration

This work deals with the ill-posed inverse problem of reconstructing a two-dimensional image of an unknown object starting from sparse and nonuniform measurements of its Fourier Transform. In particular, if we consider a priori information about the target image (e.g., the nonnegativity of the pixels), this inverse problem can be reformulated as a constrained optimization problem, in which the stationary points of the objective function can be viewed as the solutions of a deconvolution problem with a suitable kernel. We propose a fast and effective gradient-projection iterative algorithm to provide regularized solutions of such a deconvolution problem by early stopping the iterations. Preliminary results on a real-world application in astronomy are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Memory-efficient nonsmooth dynamic optimization using adaptive randomized compression

Dynamic optimization problems arise in many applications including flow control, full waveform inversion, and medical imaging. These problems are plagued by significant computational challenges. One such challenge — and the focus of this work — is the memory limitation induced by the size of the underlying dynamical system. In particular, the entire dynamic trajectory is required for derivative computation and therefore must be stored or recomputed using, e.g., checkpointing. Although recent work demonstrated the use of adaptive randomized sketching to overcome the memory challenge, that work only applies to smooth unconstrained problems, prohibiting its use for nonsmooth regularized and constrained problems. The inclusion of nonsmooth regularizers and constraints is critical as they often arise in an attempt to preserve certain physical properties or to promote sparsity. To solve these problems, we introduce a trust-region algorithm for minimizing the sum of a smooth nonconvex function and a nonsmooth convex function that leverages randomized sketching to compress the dynamical system trajectories and adaptively adjust the sketch rank to satisfy a gradient inexactness condition. We prove convergence of this algorithm and demonstrate that it achieves substantial memory reduction on three discretized PDE-constrained optimization applications.

97 MATHEMATICS AND COMPUTING↗

Single-view phase retrieval of an extended sample by exploiting edge detection and sparsity

We propose a new approach to robustly retrieve the exit wave of an extended sample from its coherent diffraction pattern by exploiting sparsity of the sample's edges. This approach enables imaging of an extended sample with a single view, without ptychography. We introduce nonlinear optimization methods that promote sparsity, and we derive update rules to robustly recover the sample's exit wave. We test these methods on simulated samples by varying the sparsity of the edge-detected representation of the exit wave. Finally, our tests illustrate the strengths and limitations of the proposed method in imaging extended samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Iterative Nonlinear Tikhonov Algorithm with Constraints for Electromagnetic Tomography

Low frequency electromagnetic tomography such as the capacitance tomography (ECT) has been proposed for monitoring and mass-gauging of gas-liquid two-phase system under microgravity condition in NASA's future long-term space missions. Due to the ill-posed inverse problem of ECT, images reconstructed using conventional linear algorithms often suffer from limitations such as low resolution and blurred edges. Hence, new efficient high resolution nonlinear imaging algorithms are needed for accurate two-phase imaging. The proposed Iterative Nonlinear Tikhonov Regularized Algorithm with Constraints (INTAC) is based on an efficient finite element method (FEM) forward model of quasi-static electromagnetic problem. It iteratively minimizes the discrepancy between FEM simulated and actual measured capacitances by adjusting the reconstructed image using the Tikhonov regularized method. More importantly, it enforces the known permittivity of two phases to the unknown pixels which exceed the reasonable range of permittivity in each iteration. This strategy does not only stabilize the converging process, but also produces sharper images. Simulations show that resolution improvement of over 2 times can be achieved by INTAC with respect to conventional approaches. Strategies to further improve spatial imaging resolution are suggested, as well as techniques to accelerate nonlinear forward model and thus increase the temporal resolution.

Xu, Feng↗

SU-G-IeP4-03: Cone Beam X-Ray Luminescence Computed Tomography Based On Generalized Gaussian Markov Random Field

Purpose: Cone beam X-ray luminescence computed tomography (CB-XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. However, the inverse problem of CB-XLCT is seriously ill-conditioned, hindering us to achieve good image quality. In this work, a novel reconstruction method based on Bayesian theory is proposed to tackle this problem Methods: Bayesian theory provides a natural framework for utilizing various kinds of available prior information to improve the reconstruction image quality. A generalized Gaussian Markov random field (GGMRF) model is proposed here to construct the prior model of the Bayesian theory. The most important feature of GGMRF model is the adjustable shape parameter p, which can be continuously adjusted from 1 to 2. The reconstruction image tends to have more edge-preserving property when p is slide to 1, while having more noise tolerance property when p is slide to 2, just like the behavior of L1 and L2 regularization methods, respectively. The proposed method provides a flexible regularization framework to adapt to a wide range of applications. Results: Numerical simulations were implemented to test the performance of the proposed method. The Digimouse atlas were employed to construct a three-dimensional mouse model, and two small cylinders were placed inside to serve as the targets. Reconstruction results show that the proposed method tends to obtain better spatial resolution with a smaller shape parameter, while better signal-to-noise image with a larger shape parameter. Quantitative indexes, contrast-to-noise ratio (CNR) and full-width at half-maximum (FWHM), were used to assess the performance of the proposed method, and confirmed its effectiveness in CB-XLCT reconstruction. Conclusion: A novel reconstruction method for CB-XLCT is proposed based on GGMRF model, which enables an adjustable performance tradeoff between L1 and L2 regularization methods. Numerical simulations were conducted to demonstrate its performance.

60 APPLIED LIFE SCIENCES↗