Search NASA⌕ Search

SEARCH · Search NASA

Results for “impact analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Life-Cycle Assessment Integration into Scalable Open-Source Numerical Models (LiAISON) for Prospective Impact Analysis of Novel Technologies

Decarbonizing the industrial sector is a significant challenge in achieving a net-zero greenhouse gas (GHG) emissions economy by 2050 and the Paris Agreement, i.e., a global climate change mitigation target of achieving a maximum average temperature change potential of 1.5 Degrees Celsius or less by 2100 with respect to pre-industrial levels. In the United States (US), the industrial sector accounts for 23% of total GHG emissions and is home to a number of hard-to-electrify activities. The chemicals subsector has the single largest subsector emissions profile after direct emissions from fossil fuel combustion and leakage from fossil fuel distribution systems. Within the chemicals subsector, many processes depend on hydrogen or ammonia precursors. Decarbonizing these two commodities would contribute significantly to decarbonizing the industrial sector as hydrogen could also be used for low carbon steel production (e.g., hydrogen-based direct reduction of iron) and other industrial applications. Emerging technologies require the application of prospective life cycle assessment (LCA), which can account for technology (foreground) scaling and process improvements via learning-by-doing, among others. In many cases, the future system context (background) in which the technologies are assumed to operate in is equally relevant. Background scenarios generated by integrated assessment models (IAM) can coherently incorporate potential future dynamics of the energy-climate-human-land system. Further, IAM scenarios are harmonized across socioeconomic and climate change mitigation pathways, which facilitates the comparability of prospective LCAs using different IAMs. We introduce an open source prospective LCA framework, the Life-cycle Assessment Integration into Scalable Open-source Numerical models (LiAISON), to analyze the non-linear relationships between technology foreground and the future energy system background across a series of midpoint and resource use metrics. The integration of LCA and IAM data is achieved using prospective environmental Impact assessment (PREMISE). We showcase it by assessing two Power-to-Hydrogen (PtH2) processes, namely Solid Oxide Electrolysis (SOE) and Polymer Electrolyte Membrane Electrolysis (PEME). We compare the technologies to a baseline of hydrogen production via natural gas-based Steam Methane Reforming (SMR) in a US context of multiple energy system and climate change mitigation futures. Besides providing an analysis that specifies the LCA results ranges with temporal and geospatial explicitness across the two technologies, metrics, and impact assessment methods, this research also aims to establish a base framework that can be expanded to use other IAM generated scenarios and US open-source life cycle inventory (LCI) databases. We find that the temporal environmental performance of either technology or their difference to SMR is directly influenced by the underlying background dynamics. Additionally we compare our results by linking two other prospective models with LiAISON - GCAM (Global Change Assessment Model) and ReEDS (Regional Energy Deployment System) to analyze the effect of changing background scenarios using varying predictions in life cycle analysis.

decarbonizing↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock: Preprint

20% of the U.S. commercial building sector's energy usage is from on-site combustion of fossil fuels for heating. Decarbonization will require electrification of these systems to meet climate goals, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for decarbonization solutions. However, there is limited understanding of the impact on emissions that considers regional electricity generation methods, as well as the impact of other heat pump intricacies such as the effects of temperature on capacity/efficiency, defrost operation, realistic sizing methodologies, and supplementary heating. This study explores the effects of transitioning all conventional RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock, DOE's calibrated model of the U.S. commercial building stock developed by NREL. Results show 9% and 17% reductions in stock aggregate energy consumption and GHG emissions, respectively. Furthermore, average heat pump operational details are presented by state. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building electrification↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Distributed Photovoltaic Economic Impact Analysis in Indonesia

Like other countries in the region, the Government of Indonesia aims to increase its use renewable energy in the near term from various technologies, including grid-connected distributed photovoltaics (DPV). While little DPV has been installed to date, the policy landscape has been shifting over the past few years with recent pronouncements from the state-run utility Perusahaan Listrik Negara (PLN) and the Ministry of Energy and Mines (MEMR) that have begun to provide a more supportive policy framework for the deployment of DPV. Nonetheless, many questions remain as to how DPV impacts customers, the utility, and the economy as a whole. This report presents a holistic view of DPV economic impacts in the Java-Bali region of Indonesia by assessing customer economic impacts, utility revenue impacts, and jobs and economic development impacts.

14 SOLAR ENERGY↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

Impact analysis of DERs on bulk power system stability through the parameterization of aggregated DER_a model for real feeders

With an ever increasing percentage of distributed energy resources (DERs) connected behind the meter in the distribution system, it is becoming increasingly important to equip transmission planners with the visibility of DER dynamic performance in distribution system. Not having visibility of the disconnection of DERs with the occurrence of transmission events, could result in an erroneous view of the stability of bulk power system. Here, in this paper, a parameterized aggregated model (DER_a) serves as a representation of the distribution-level dynamics of real residential feeders, which is used for analysis of bulk power system stability. The parameters are obtained by executing dynamic Monte Carlo simulations. Faults are then induced at the substation level causing the DERs to trip which subsequently enables the parameterization of the low and high voltage breakpoints (v l0 , v l1 , v h0 , and v h1 ) of the DER_a model’s partial voltage trip block. These parameters are then utilized to study the effectiveness of the DER_a model to represent the behavior of the aggregated DERs’ response and their impact on the bulk power system. The case study shows the ability of the positive-sequence DER_a model to provide an accurate estimation of DERs that are susceptible to trip due to 3-$\phi$ and 1-$\phi$ faults of transmission.

14 SOLAR ENERGY↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Comprehensive process and environmental impact analysis of integrated DBD plasma steam methane reforming

Utilization of electricity generated from renewable sources to obtain hydrogen, H 2 , is of critical importance to decrease the overall carbon footprint. Here in this work, integration of a dielectric discharge barrier (DBD) plasma reactor to convert low calorific value gas, such as landfill gas or coal mine gas into hydrogen, into the existing steam methane reforming (SMR) technology was evaluated using process design considerations. In particular, a DBD-enhanced catalytic SMR reactor was modeled to operate at near atmospheric pressure and 500 °C sequentially with the conventional reformer to obtain ~ 65 kmol/hr H2 for distributed production. This allowed decreasing the size of the conventional reformer albeit at the increased overall electricity consumption. Calculated process economics showed that only at an electricity cost of less than $0.004/kWh does the hybrid DBD plasma process derived H 2 price become competitive with that of the conventional SMR. A Life Cycle Assessment framework was used to compare environmental impacts from the conventional SMR, hybrid DBD SMR and hybrid DBD SMR utilizing only onshore wind-derived electricity. Larger environmental impacts in the plasma reformer were obtained due to the use of electricity for the plasma reforming operation, which was modeled as coming from the typical U.S. grid mix. Utilizing only 100% wind-derived electricity provided certain environmental benefits, except for the ecotoxicity impact where the wind power scenario modeled here only reduced ecotoxicity impacts associated with electricity by 30%.

08 HYDROGEN↗

Vibro-impact analysis and characterization of pipeline conveying fluids with multi-segmented motion-limiting constraints

Previous studies of the cantilevered pipeline conveying fluid system have included motion-limiting constraints in the form of trilinear springs. While this is desirable in experimental scenarios, it may not be representative of real-world applications. Therefore, here, this study focuses on multi-segmented motion-limiting constraints. As this type of motion-limiting constraint has not been investigated with a cantilevered pipeline system, a wide variety of outer and inner constraint stiffness and constraint gap sizes are investigated in this study to gain a comprehensive understanding of how the multi-segmented constraints affect the dynamics of the cantilevered pipeline. In this effort, bifurcation diagrams, phase portraits, Poincare maps, time histories, and power spectra are used to investigate the dynamics of the system, and the fluid flow speeds where dynamic characteristics are considered. In general, it is found that critical flow speeds like when the pipe sticks in the constraints are reduced as the constraint stiffnesses are increased. Additionally, the sticking flow speed occurred at lower flow speeds as the gap sizes of the inner and outer constraints decrease, and a larger constraint offset results in a smaller inner gap size leading to critical behaviors occurring at earlier flow speeds.

97 MATHEMATICS AND COMPUTING↗

Exploring thermal runaway propagation in Li-ion batteries through high-speed X-ray imaging and thermal analysis: Impact of cell chemistry and electrical connections

Battery safety design is important to consider from the individual Li-ion cell to the level of the macro-system. On the macro-level, failure in one single cell can lead to propagation of the thermal runaway and rapidly set a whole battery pack on fire. Factors that can impact the propagation outcome, such as cell model/chemistry and electrical connection are here investigated using a combination of measurements. Several abusive tests were conducted, combining two different cell models (Molicel P42A and LG M50, both 21700s) in series and parallel connections (16 tests per configuration). Overall, a propagation outcome of 56% was measured from the 32 conducted tests, a minimum temperature of 150 °C was required to initiate propagation, and the fastest propagation occurred in 123 s. Temperature measurements were higher in series connected cells, initiating the discussion of cell chemistry and internal resistance on this effect. The difference in current-flow during thermal runaway in series and parallel connections, and how this can affect the temperature evolution is further discussed. Spatio-temporal mapping of X-ray radiography allowed us to derive the speed of thermal runaway evolution inside the battery and has shown that series connected cells, in particular P42A, occur faster. It was further observed that deviant sidewall behaviors such as temperature-induced breaches and pressure-induced ruptures occurred in P42As only respective nail-penetrated cells only.

25 ENERGY STORAGE↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗