Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedance-based modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Nodal Admittance Matrix Based Area Partition Method for Small-Signal Stability Analysis of Large-Scale Power Electronics Based Power Systems

In power electronics-based power systems (PEPSs), small-signal stability is an important factor for system design and operation, where the impedance-based approach is often used. However, unlike small-scale PEPSs with simple and straightforward impedance models, it would take much more efforts to derive the large-scale PEPSs impedance model, which is very complicated and sometimes may get wrong results due to the elimination of right-half plane (RHP) poles during the impedance aggregation process. To simplify the derivation procedure and analyze the small-signal stability of large-scale PEPSs, this paper proposes a nodal admittance matrix (NAM) based area partition method. In this method, the large-scale PEPS is divided into several sub-areas, and the stability is analyzed within the sub-area first, and then the interconnection stability among these sub-areas is analyzed. The proposed method is scalable and can help to locate the weakest areas/converters that may cause instability in the whole system. In this paper, the concept of the proposed method and its application to an example system are introduced. Experimental results are also given to validate the effectiveness of the proposed method.

Qiao, Liang↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Wideband Impedance Passivation of MMCs for Suppressing Harmonic Oscillations

Harmonic instability and associated oscillation events have become one of the main concerns in MMC-based HVdc systems. These oscillations can appear in the range from a few hundred hertz to several kilohertz, and the root cause is identified as delay-induced negative damping of MMC impedance appearing at the system resonance frequency. Here, this paper introduces a wideband impedance reshaping method through MMC control to eliminate such negative damping for both grid-following (GFL) and grid-forming (GFM) MMCs, which makes the MMC impedance completely passive from the second harmonic frequency upward, thus preventing all harmonic oscillations. First, simplified impedance models of MMCs are derived for the harmonic stability analysis and the impedance reshaping control design. Next, a passivity-based impedance reshaping method is presented, as well as practical considerations for its implementation. In addition, to maintain the MMC's disturbance ride-through capability, an adaptive activation scheme is developed, which enables the wideband impedance reshaping control only in the presence of harmonic oscillation events. The effectiveness of the proposed method is validated by frequency domain analysis and by electromagnetic transient (EMT) simulations of two typical MMC-based power systems.

17 WIND ENERGY↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Piezoelectric impedance-based high-accuracy damage identification using sparsity conscious multi-objective optimization inverse analysis

Two elements are essential in structural health monitoring utilizing dynamic responses: response measurement with high-frequency contents, i.e., small characteristic wavelengths, that can adequately reflect damage features, and effective inverse identification analysis that is however oftentimes under-determined. The advancement of smart structure integration has led to active interrogation through frequency-sweeping piezoelectric impedance measurement at high frequency range. In this research we develop a multi-objective optimization formulation for the identification of damage location and severity utilizing piezoelectric impedance. While one optimization objective is to match the response measurement with finite element model prediction in the damage parametric space, the other is the number of locations of damage, i.e., the sparsity of damage index as the solution vector, since damage usually occurs within a small number of locations. This multi-objective formulation fits well the under-determined nature of damage identification, as it naturally provides multiple solutions as basis for further elucidation. The challenge remaining is how to find a small solution set that can include the actual damage scenario. Here we develop a novel inverse identification framework utilizing the intelligent swarm optimizer which possesses flexibility for enhancement. We first embed a sparsity enforcement process into the population generation of the optimizer, which yields a solution repository intrinsically possessing sparsity. We then apply reinforcement learning so the agents can adaptively opt for local strategies with the aim of enriching the searching patterns to diversify the solutions. Through the incorporation of a Q-table, searching toward more promising directions will be rewarded. Our case analyses employing experimental data indicate that this sparsity-conscious multi-objective particle swarm optimization technique can lead to a small solution set which generally encompasses the true damage scenario. This effectively solves the structural damage identification problem with piezoelectric impedance measurement.

Yang Zhang↗

CGI for Impedance Characterization of Inverter-Coupled Generation

This presentation provides an overview of impedance characterization of inverter-coupled generation using the 7 MVA/13.2 kV grid simulator (controllable grid interface) at the National Wind Technology Center of NREL. The presentation shows how sequence impedance responses of multi-megawatt inverters and wind turbines are measured using the grid simulator. Applications of the measured impedance responses for the evaluation of dynamic interactions and high-fidelity model validation are demonstrated. The presentation also shows application of large-signal impedance theory for the prediction of harmonics generated by subsynchronous resonance (SSR) of DFIG-based Type-III wind turbines with series-compensated transmission lines. Finally, a new method for impedance-based characterization of power system frequency response is presented to enable real-time estimation of system inertia and primary frequency response (PFR), and to support control design for frequency support by inverter-coupled generation.

17 WIND ENERGY↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗