Search NASA⌕ Search

SEARCH · Search NASA

Results for “impedence analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Robust Interpretation of Electrochemical Impedance Spectra Using Numerical Complex Analysis

Electrochemical Impedance Spectroscopy (EIS) is a noninvasive technique widely used for understanding charge transfer and charge transport processes in electrochemical systems and devices. Standard approaches for the interpretation of EIS data involve starting with a hypothetical circuit model for the physical processes in the device based on experience/intuition and then fitting the EIS data to this circuit model. This work explores a mathematical approach for extracting key characteristic features from EIS data by relying on fundamental principles of complex analysis. These characteristic features can suggest the presence of inductors and constant phase elements (nonideal capacitors) from impedance data and enable us to answer questions about the identifiability and nonuniqueness of equivalent circuit models. In certain scenarios such as models with only resistors and capacitors, we are able to enumerate all possible families of circuit models. Finally, we apply the mathematical framework presented here to real-world electrochemical systems and highlight results using impedance measurements from a lithium-ion battery coin cell.

charge transfer↗

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

Effect of H + Exchange and Surface Impurities on Bulk and Interfacial Electrochemistry of Garnet Solid Electrolytes

Contact loss and current constriction pose significant challenges at the Li metal interface of solid-state batteries. For garnet-structured Li 7 La 3 Zr 2 O 12 (LLZO), these effects are amplified by Li + /H + exchange and surface contamination reactions, which lead to conductivity losses and poor Li wetting. In this study, we utilize a variety of surface treatment processes across 37 cells to selectively induce proton exchange and contamination reactions in LLZO. The resulting bulk and surface chemistry is systematically characterized and correlated to changes in electrochemical properties. Additionally, we combine impedance analysis and finite element method modeling to deconvolute sources of impedance contributions at the Li metal interface. Specifically, we show that constriction impedance at the Li metal interface arises not solely from voids, but also from ionically-resistive surface contaminants. Further, these findings emphasize the connection between ionic conductivity and constriction, demonstrating that micron-scale ionically-resistive components increase constriction even with identical contact geometries. Finally, we leverage our comprehensive dataset to highlight unstable overpotential growth as a failure mechanism, additionally showing that the phase of a cell’s impedance is a sensitive indicator for the onset of interfacial instability. Overall, this study clarifies the impacts of proton exchange and surface contamination on electrochemical properties at the Li|solid electrolyte interface and elucidates insights that are generalizable to other solid-state battery systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulmonary-impedance power spectral analysis: A facile means of detecting radiation-induced gastrointestinal distress and performance decrement in man

Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.

Rick, R. C.↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

Development and Validation of an Interactive Liner Design and Impedance Modeling Tool

The Interactive Liner Impedance Analysis and Design (ILIAD) tool is a LabVIEW-based software package used to design the composite surface impedance of a series of small-diameter quarter-wavelength resonators incorporating variable depth and sharp bends. Such structures are useful for packaging broadband acoustic liners into constrained spaces for turbofan engine noise control applications. ILIAD s graphical user interface allows the acoustic channel geometry to be drawn in the liner volume while the surface impedance and absorption coefficient calculations are updated in real-time. A one-dimensional transmission line model serves as the basis for the impedance calculation and can be applied to many liner configurations. Experimentally, tonal and broadband acoustic data were acquired in the NASA Langley Normal Incidence Tube over the frequency range of 500 to 3000 Hz at 120 and 140 dB SPL. Normalized impedance spectra were measured using the Two-Microphone Method for the various combinations of channel configurations. Comparisons between the computed and measured impedances show excellent agreement for broadband liners comprised of multiple, variable-depth channels. The software can be used to design arrays of resonators that can be packaged into complex geometries heretofore unsuitable for effective acoustic treatment.

Howerton, Brian M.↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Easy, Scalable Subsetting of GEDI Point Clouds

The GEDI Subsetter, a Python tool developed for NASA’s Multi-mission Algorithm and Analysis Platform (MAAP), optimizes the accessibility and visualization of GEDI point clouds by enabling users to efficiently subset data in a convenient, scalable manner. Complex science data often requires users to learn new software skills and handle many large files. Handling and cleaning large data sets is tedious and error-prone. These challenges significantly impede analysis. One of the goals of NASA's MAAP is to provide a platform that lowers the barrier to conducting research and analysis at scale. When a group of MAAP users wanted to conduct above-ground biomass estimation using GEDI data, we found that their existing workflow for leveraging GEDI data suffered from the barriers mentioned above. Furthermore, their workflow did not scale easily beyond a small number of granules. We found that existing tools related to GEDI data retrieval and subsetting were too limiting, so the GEDI Subsetter was written to support MAAP users’ needs. Being able to run many subsetting jobs simultaneously in the MAAP, and parallelizing the code itself, has led to significant speed improvements in obtaining relevant data, reducing subsetting time from hours to minutes. MAAP users can now more quickly and easily obtain only the data relevant to their research, by choosing which GEDI collection they want to work with (L1A, L2A, L2B, or L4A), and how they want to subset it, by specifying an area of interest, a temporal range, and relevant attributes. This has significantly reduced the feedback loop for users, allowing them to much more quickly subset GEDI data and begin their analysis. Although the GEDI Subsetter originally targeted users of the MAAP, it is generalized such that it can also be used outside of the MAAP and includes a command-line interface for convenience. Furthermore, with minor modifications, it should be possible to use it with non-GEDI data as the general pattern should be applicable to other sparse/track-based sensors.

Charles Daniels↗

Transfer-matrices for series-type microwave antenna circuits

Transfer matrices are developed which permit analysis and computer evaluation of certain series type microwave antenna circuits associated with an L-Band microwave radiometer (LBMR) under investigation at Goddard Space Flight Center. This radiometer is one of several diverse instrument designs to be used for the determination of soil moisture, sea state, salinity, and temperature data. Four port matrix notation is used throughout for the evaluation of LBMR circuits with mismatched couplers and lossy transmission lines. Matrix parameters in examples are predicted on an impedance analysis and an assumption of an array aperture distribution. The notation presented is easily adapted to longer and more varied chains of matrices, and to matrices of larger dimension.

Schmidt, R. F.↗

Interfacial and Kinetic Origins of Voltage Loss in Neutral Zinc‐Air Batteries

Rechargeable zinc-air batteries are promising candidates for grid-scale energy storage; however, their practical deployment is limited by oxygen electrocatalysis inefficiencies and interfacial instabilities, particularly outside conventional alkaline electrolytes. Here, in this work, zinc-air batteries operating under neutral electrolyte conditions using ZnCl 2 soaked KC-PAA-PAM gel polymer electrolytes and electrochemically synthesized Ni/Fe layered double hydroxide electrocatalysts is investigated. Ni/Fe-LDH is intentionally employed as an OER-biased benchmark catalyst to diagnose electrolyte and interface driven limitations rather than as a bifunctional ORR/OER solution. Full cells exhibit highly stable cycling over hundreds of hours, yet operate at substantially suppressed charge and discharge voltages relative to the thermodynamic value. Electrochemical impedance analysis shows that ohmic losses contribute only minimally to this voltage suppression. Post-mortem X-ray photoelectron spectroscopy reveals metallic zinc accumulation on the air cathode and chloride-containing species on the anode, indicating parasitic interfacial processes. Synchrotron-based soft X-ray absorption spectroscopy confirms stable Ni 2+ and Fe 3+ oxidation states during cycling, consistent with OER-biased catalytic behavior, while neutral-electrolyte oxygen evolution measurements demonstrate strong electrolyte-induced suppression of oxygen kinetics. Together, these results show that electrolyte chemistry and cathode-side parasitic processes, rather than catalyst identity alone, dominate voltage losses in neutral zinc-air batteries, providing mechanistic insight into the fundamental challenges associated with neutral electrolyte operation.

Long duration energy storage↗

Dependence of Linker Length and Composition on Ionic Conductivity and Lithium Deposition in Single-Ion Conducting Network Polymers

In this report, single-ion conducting electrolytes stand as promising alternatives to state-of-the-Art electrolytes in lithium batteries, although a single-ion conducting material with high Li + conductivity, stability in contact with lithium, and suitable mechanical properties has been slow to emerge. Here, we describe the synthesis of a series of single-ion conducting network polymers from the reaction of tetrakis(4-(chloromethyl)-2,3,5,6-Tetrafluorophenyl)borate with oligoethylene glycoxide linkers Li 2 O[(CH 2 CH 2 )O] n (n = 1, 2, 3, 9, and 22). Polymers with the longest linkers (n = 9 and 22; ANP-9 and ANP-10, respectively) form materials with conductivities of ~ 10 -6 S cm -1 at 100 °C. With the addition of 65 wt % propylene carbonate (PC), all the network polymers in the series exhibit high conductivities at ambient temperatures, with the n = 1 material (ANP-6) achieving a bulk ionic conductivity of 2.5 x 10 -4 S cm -1 at 25 °C. More conductive single-ion conducting gels could be prepared by using the less coordinating pentanediol dilithium salt as a linker (ANP-11; σ = 3.5 x 10 -4 S cm -1 at 25 °C), although this material exhibited a surprisingly high interfacial resistance in contact with a lithium electrode. In contrast, the gel formed with ANP-6 is notably stable in contact with metallic lithium electrodes, displays a lithium-ion transference number of unity, and boasts a wide electrochemical stability window of greater than 4.5 V. Temperature-dependent ac impedance analysis reveals that the ionic conductivity of this material-and likely the other gels in the series-matches closely to a Vogel-Tamman-Fulcher temperature model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lanthanum Strontium Cobaltite-Alumina Fiber Composite Contact Material for Solid Oxide Fuel Cells

Short alumina fibers were added to LSCo contact material to enhance the contact strength and improve thermal cycle stability. Alumina fiber from 2.5 v% to 20 v% were mixed with LSCo and sintered at elevated temperatures. Sintering study showed retardation in densification of LSCo matrix with increasing alumina content. Sintered bulk strength exhibited similar behavior where strength greatly reduced at high alumina v%. Coefficient of thermal expansion showed consistent results with prediction from rule of mixture. Contact strength using anode supported YSZ bilayer coupons improved greatly with the presence of small amount (2.5-5 v%) alumina fibers and no substantial reduction after 10 deep thermal cycles. Candidate LSCo-Al2O3 contact materials was validated in a generic stack test fixture for 1000h at 800oC followed by 10 thermal cycles. Results of impedance analysis showed substantial improvement in thermal cycle stability as compared to LSCo parent materials.

SOFC cathode, strength, LSCo, alumina↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗