Search NASA⌕ Search

SEARCH · Search NASA

Results for “in-situ atomic force microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

26 records · Page 2

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

A multi-technique approach to understanding delithiation damage in LiCoO2 thin films

Abstract We report on the delithiation of LiCoO 2 thin films using oxalic acid (C 2 H 2 O 4 ) with the goal of understanding the structural degradation of an insertion oxide associated with Li chemical extraction. Using a multi-technique approach that includes synchrotron radiation X-ray diffraction, scanning electron microscopy, micro Raman spectroscopy, photoelectron spectroscopy and conductive atomic force microscopy we reveal the balance between selective Li extraction and structural damage. We identify three different delithiation regimes, related to surface processes, bulk delithiation and damage generation. We find that only a fraction of the grains is affected by the delithiation process, which may create local inhomogeneities. However, the bulk delithiation regime is effective to delithiate the LCO film. All experimental evidence collected indicates that the delithiation process in this regime mimics the behavior of LCO upon electrochemical delithiation. We discard the formation of Co oxalate during the chemical extraction process. In conclusion, the chemical route to Li extraction provides additional opportunities to investigate delithiation while avoiding the complications associated with electrolyte breakdown and simplifying in-situ measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superior photodynamic effect of single-walled carbon nanotubes in aprotic media: a kinetic study

It has been confirmed that single-walled carbon nanotubes (SWCNTs) could generate reactive oxygen species in aprotic media by utilizing photon energy. However, the impact of photon irradiation on SWCNTs and the kinetics of the generation process in aprotic media are still unclear, which significantly limits the yield performance. In this work, the kinetics for photodynamic effects has been investigated by performing characterizations on ultraviolet-treated SWCNTs using Raman spectroscopy, conductive atomic force microscope (in-situ), kelvin probe force microscope, and X-ray photoelectron spectroscopy. It is found that ultraviolet-treated SWCNTs are observed to have more defects, lower conductivity, and less surface charge after energy conversion. Starting from the fundamental intrinsic properties of SWCNTs, the kinetics and formation of these changes are thoroughly discussed. It turns out that the dispersion, chirality, and structural integrity of SWCNTs are important for achieving high-performance photodynamic effects, which are validated using several different SWCNTs as well as other carbon nanomaterials. A type of (6,5) s-SWCNTs exhibited the highest energy efficiency among a variety of other carbon nanomaterials. The yield rate is 2.15 mM/h, and the energy consumption is determined to be 2.79 W∙h/mM. This work is expected to help dramatically boost the energy efficiency of the photodynamic effect in aprotic media and pave the way for designing high-performance carbon nanomaterial-based photoinduced devices.

36 MATERIALS SCIENCE↗

Defect annihilation in heavy ion irradiated polycrystalline gold

In this study, we explore the interaction of electron wind force (EWF) with defects originating from ion irradiation in-situ inside a transmission electron microscope. Nanocrystalline gold specimens were self-ion irradiated to a dose of 5 × 10 15 ions/cm 2 (45 displacement per atom) to generate a high density of displacement damage. We also developed a molecular dynamics simulation model to understand the associated atomic scale mechanisms. Both experiments and simulations show that the EWF can impart significant defect mobility even at low temperatures, resulting in the migration and elimination of defects in a few minutes. Overall, we propose that the EWF interacts with defects to create highly glissile Shockley partial dislocations, which makes the fast and low temperature defect annihilation possible.

36 MATERIALS SCIENCE↗

Nanoscale Measurements of Charge Transfer at Cocatalyst/Semiconductor Interfaces in BiVO 4 Particle Photocatalysts

Semiconductor photocatalyst particles convert solar energy to fuels like H 2 . The particles are often assumed to provide crystalline-facet-dependent electron-hole separation. A common strategy is to deposit HER electrocatalyst on electron-selective facets and OER electrocatalyst on hole-selective facets. A precise understanding of how charge-carrier-selective contacts emerges and how they rationally designed, however, is missing. Using a combination of ex-situ and in-situ conducting-AFM experiments and new ionomer/catalyst-semiconductor test structures, we show how heterogeneity in charge-carrier selectivity can be measured at the nanoscale. We discover that the presence of interface water/electrolyte is critical to induce hole selectivity between the CoO x water-oxidation catalyst and the BiVO 4 light absorber. pH-dependent measurements suggest that negative surface charge on the semiconductor is central to inducing hole selectivity. Furthermore, the work also demonstrates a new approach to control local pH and introduce water using thin-film ionomers compatible with conductive-AFM measurements.

14 SOLAR ENERGY↗

Structural Evolution and Stability of Rh/TiO 2 Catalysts under CO 2 Hydrogenation Conditions: Influence of the Initial Rh Structure

Characterizing catalyst stability by identifying the predominant mechanisms, timescales and driving forces of catalyst reconstruction under relevant reaction conditions is necessary for the design and commercialization of new catalysts. Here, in this paper, we study Rh/TiO 2 catalysts under CO 2 hydrogenation conditions (773 K, 75% H 2 , 25% CO 2 ) at high conversion and utilize reactivity studies along with ex-situ and in-situ spectroscopy and microscopy to characterize changes in catalyst activity and structure as a function of time on stream and the initial catalyst structure. This is a prototypical catalyst for CO 2 hydrogenation where Rh structure and Rh-TiO 2 interactions have been proposed to explain reactivity, selectivity (between CO and CH 4 formation) and catalyst stability. The influence of the initial Rh structure (varying from Rh single atoms to Rh nanoparticles), support stability, regeneration and pretreatment(s), and the chemical potential(s) of the reaction environment on reaction selectivity and catalyst stability were explored. The product selectivity between CO and CH 4 was determined to be dependent on the relative fraction of Rh single atoms and Rh nanoparticle-TiO 2 interfacial sites under reaction conditions, each exhibiting distinct stability under prolonged time on stream. Surprisingly, Rh single atoms exhibited stability for the duration of 90 h reactivity measurements, even at high Rh density (≥ 1.8 Rh atoms/nm 2 ) on the support, while Rh nanoparticles sintered under reaction conditions. As a result, all catalysts exhibited increasing selectivity to CO with increasing time on stream (> 10 h). We conclude the distribution of Rh structures evolved over time under reaction conditions through three distinct reconstruction mechanisms (Rh particle fragmentation, Ostwald ripening, and particle migration and coalescence) that occurred on varying timescales. Catalyst stability on the ~90 h time scale was ultimately controlled by the initial Rh structure.

25 ENERGY STORAGE↗

Pinhole-seeded lateral epitaxy and exfoliation of GaSb films on graphene-terminated surfaces

Abstract Remote epitaxy is a promising approach for synthesizing exfoliatable crystalline membranes and enabling epitaxy of materials with large lattice mismatch. However, the atomic scale mechanisms for remote epitaxy remain unclear. Here we experimentally demonstrate that GaSb films grow on graphene-terminated GaSb (001) via a seeded lateral epitaxy mechanism, in which pinhole defects in the graphene serve as selective nucleation sites, followed by lateral epitaxy and coalescence into a continuous film. Remote interactions are not necessary in order to explain the growth. Importantly, the small size of the pinholes permits exfoliation of continuous, free-standing GaSb membranes. Due to the chemical similarity between GaSb and other III-V materials, we anticipate this mechanism to apply more generally to other materials. By combining molecular beam epitaxy with in-situ electron diffraction and photoemission, plus ex-situ atomic force microscopy and Raman spectroscopy, we track the graphene defect generation and GaSb growth evolution a few monolayers at a time. Our results show that the controlled introduction of nanoscale openings in graphene provides an alternative route towards tuning the growth and properties of 3D epitaxial films and membranes on 2D material masks.

36 MATERIALS SCIENCE↗