Search NASA⌕ Search

SEARCH · Search NASA

Results for “in-situ spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Assumptions about the presence of natural glasses on Mars

Natural glasses occur not only on Earth but also in lunar rocks and in some meteorites. On geological grounds, natural glasses could be expected on the surface of Mars and their presence would have important implications for the weathering and alteration of the near-surface layer. Ultramafic and mafic magmatism rich in iron and some volatiles appears to have been important on Mars as has been impact cratering, volcanism, and possibly hydrothermal alteration. Available data indicate that we can presume the past or present existence of volcanic basaltic glasses, impact glasses formed by thermal fusion of meteorite-impact targets, and diaplectic (mainly maskelynite) glasses. Conditions appear unsuitable for the formation of tektites on the Martian surface, and the production of measurable amounts of fulgurite or combustion glass seems improbable. Prospects for the remote and in-situ identification of Martian glasses and their subsequent weathering products are discussed and include orbital reflectance and thermal emission spectroscopic measurements and Mossbauer spectroscopy from a surface lander.

Bouska, Vladimir↗

Evidence for Microfossils in Ancient Rocks and Meteorites

The McKay et all. detection of chemical biomarkers and possible microfossils in an ancient meteorite from Mars (ALH84001) stimulated research in several areas of importance to the newly emerging field of Astrobiology. Their report resulted in a search for additional evidence of microfossils in ancient terrestrial rocks and meteorites. These studies of ancient rocks and meteorites were conducted independently (and later collaboratively) in the United States and Russia using the SEM, Environmental Scanning Electron Microscope (ESEM), and Field Emission Scanning Electron Microscope (FESEM). We have encountered in-situ in freshly broken carbonaceous chondrites a large number of complex microstructures that appear to be lithified microbial forms. The meteoritic microstructures have characteristics similar to the lithified remains of filamentous cyanobacteria and bacterial microfossils we have found in ancient phosphorites, ancient graphites and oil shales. Energy Dispersive Spectroscopy (EDS) and Link microprobe analysis shows the possible microfossils have a distribution of chemical elements characteristic of the meteorite rock matrix, although many exhibit a superimposed carbon enhancement. We have concluded that the mineralized bodies encountered embedded in the rock matrix of freshly fractured meteoritic surfaces can not be dismissed as recent surface contaminants. Many of the forms found in-situ in the Murchison, Efremovka, and Orgueil carbonaceous meteorites are strikingly similar to microfossils of coccoid bacteria, cyanobacteria and fungi such as we have found in the Cambrian phosphorites of Khubsugul, Mongolia and high carbon Phanerozoic and Precambrian rocks of the Siberian and Russian Platforms.

Hoover, Richard B.↗

Meteorites, Microfossils and Exobiology

The discovery of evidence for biogenic activity and possible microfossils in a Martian meteorite may have initiated a paradigm shift regarding the existence of extraterrestrial microbial life. Terrestrial extremophiles that live in deep granite and hydrothermal vents and nanofossils in volcanic tuffs have altered the premise that microbial life and microfossils are inconsistent with volcanic activity and igneous rocks. Evidence for biogenic activity and microfossils in meteorites can no longer be dismissed solely because the meteoritic rock matrix is not sedimentary. Meteorite impact-ejection and comets provide mechanisms for planetary cross-contamination of biogenic chemicals, microfossils, and living microorganisms. Hence, previously dismissed evidence for complex indigenous biochemicals and possible microfossils in carbonaceous chondrites must be re-examined. Many similar, unidentifiable, biological-like microstructures have been found in different carbonaceous chondrites and the prevailing terrestrial contaminant model is considered suspect. This paper reports the discovery of microfossils indigenous to the Murchison meteorite. These forms were found in-situ in freshly broken, interior surfaces of the meteorite. Environmental Scanning Electron Microscope (ESEM) and optical microscopy images indicate that a population of different biological-like forms are represented. Energy Dispersive Spectroscopy reveals these forms have high carbon content overlaying an elemental distribution similar to the matrix. Efforts at identification with terrestrial microfossils and microorganisms were negative. Some forms strongly resemble bodies previously isolated in the Orgueil meteorite and considered microfossils by prior researchers. The Murchison forms are interpreted to represent an indigenous population of the preserved and altered carbonized remains (microfossils) of microorganisms that lived in the parent body of this meteorite at diverse times during the past 4.5 billion years (Gy).

Hoover, Richard B.↗

The Nimbus 4 infrared spectroscopy experiment. 2: Comparison of observed and theoretical radiance from 425-1450 cm(minus 1)

The Nimbus 4 infrared interferometer spectrometer (IRIS) measured the thermal emission of the earth's atmosphere and surface from 400-1600/cm with an apodized spectral resolution of 2.8/cm. A comparison of theoretical radiances, computed from in-situ measurements and using a direct integration slant path atmospheric transmittance model, with the observed IRIS radiances has been made to verify the radiometeric and spectral performance of the instrument and to assess the accuracy of the atmospheric transmittances. The radiance comparison has indicated a relatively constant difference of less than 5% in the water vapor continuum in the 425-550/cm and 750-1200/cm atmospheric window regions while in the 667/cm CO2 band the difference was 5-10%. The absolute accuracy was found to be approximately 5-10% for each of the parameters; measured radiances, in-situ measurements, and the atmospheric transmittances, thus it is not possible to uniquely specify the degree of error arising from each parameter in the total resultant difference.

Kunde, V. G.↗

In-Situ Cure Monitoring of the Immidization Reaction of PMR-15

Glass fiber reinforced polymer composites are becoming widely used in industry. With this increase in production, an in-situ method of quality control for the curing of the polymer is desirable. This would allow for the production of high-quality parts having more uniform properties.' Recently, in-situ fiber optic monitoring of polymer curing has primarily focused on epoxy resins and has been performed by Raman or fluorescence methods. In addition, some infrared (IR) investigations have been performed using transmission or ATR cells. An alternate IR approach involves using optical fibers as a sensor by utilizing evanescent wave spectroscopy.

Cossins, Sheryl↗

An x ray photoelectron spectroscopy study of Au(x)In(y) alloys

Four gold-indium alloys were studied by x ray photoelectron spectroscopy. The binding energies and intensity ratios of the Au 4f7/2 and In 3d5/2 core levels were determined for the bulk alloy compositions of Au(10 percent In), Au3In, AuIn, and AuIn2. These values were determined for the native oxides on the materials, for the surfaces prepared by ion bombardment to remove the oxide and for surfaces scraped in-situ with a ceramic tool to expose the bulk composition. These results furnish calibration values that allow determination of the composition of thin films of this alloy system. In addition the binding energies add to the data base for understanding the effect of alloying on core level binding energies. As an illustration, these results are used to determine the composition of a series of alloy films formed by incongruent evaporation of an alloy charge.

Jayne, Douglas T.↗

Characterization of In-Situ BN Interface Formed by Nitridation of Nextel 312

Treatment of Nextel (TM) 312 in a reactive environment has been used as a low cost approach to the formation of BN on the fiber surface. Although the BN enriched surface region is extremely thin (less than 40 run), it is effective in providing debonding and composite behavior. Variation in mechanical behavior of Nextel (TM) 312/BN/Blackglas (TM) composites has been noted among panels fabricated with AF-10 cloth treated in different nitridation runs, Understanding this variation became the rationale for undertaking a detailed characterization of the nitrided fiber using field emission scanning electron microscopy, low voltage energy dispersive x-ray and Auger electron spectroscopy. Chemical composition and surface morphology are discussed in relation to observed mechanical behavior of NeXtel (TM) 312/Blackglas (TM) composites tested in bending.

Hurwitz, Fances I.↗

Evidence of Microfossils in Carbonaceous Chondrites

Investigations have been carried out on freshly broken, internal surfaces of the Murchison, Efremovka and Orgueil carbonaceous chondrites using Scanning Electron Microscopes (SEM) in Russia and the Environmental Scanning Electron Microscope (ESEM) in the United States. These independent studies on different samples of the meteorites have resulted in the detection of numerous spherical and ellipsoidal bodies (some with spikes) similar to the forms of uncertain biogenicity that were designated "organized elements" by prior researchers. We have also encountered numerous complex biomorphic microstructures in these carbonaceous chondrites. Many of these complex bodies exhibit diverse characteristics reminiscent of microfossils of cyanobacteria such as we have investigated in ancient phosphorites and high carbon rocks (e.g. oil shales). Energy Dispersive Spectroscopy (EDS) analysis and 2D elemental maps shows enhanced carbon content in the bodies superimposed upon the elemental distributions characteristic of the chondritic matrix. The size, distribution, composition, and indications of cell walls, reproductive and life cycle developmental stages of these bodies are strongly suggestive of biology' These bodies appear to be mineralized and embedded within the meteorite matrix, and can not be attributed to recent surface contamination effects. Consequently, we have interpreted these in-situ microstructures to represent the lithified remains of prokaryotes and filamentous cyanobacteria. We also detected in Orgueil microstructures morphologically similar to fibrous kerite crystals. We present images of many biomorphic microstructures and possible microfossils found in the Murchison, Efremovka, and Orgueil chondrites and compare these forms with known microfossils from the Cambrian phosphate-rich rocks (phosphorites) of Khubsugul, Northern Mongolia.

Hoover, Richard B.↗

Solar system exploration from the Moon: Synoptic and comparative study of bodies in our Planetary system

An observational approach to Planetary Sciences and exploration from Earth applies to a quite limited number of targets, but most of these are spatially complex, and exhibit variability and evolution on a number of temporal scales which lie within the scope of possible observations. Advancing our understanding of the underlying physics requires the study of interactions between the various elements of such systems, and also requires study of the comparative response of both a given object to various conditions and of comparable objects to similar conditions. These studies are best conducted in 'campaigns', i.e. comprehensive programs combining simultaneous coherent observations of every interacting piece of the puzzle. The requirements include both imaging and spectroscopy over a wide spectral range, from UV to IR. While temporal simultaneity of operation in various modes is a key feature, these observations are also conducted over extended periods of time. The moon is a prime site offering long unbroken observation times and high positional stability, observations at small angular separation from the sun, comparative studies of planet Earth, and valuable technical advantages. A lunar observatory should become a central piece of any coherent set of planetary missions, supplying in-situ explorations with the synoptic and comparative data necessary for proper advance planning, correlative observations during the active exploratory phase, and follow-up studies of the target body or of related objects.

Bruston, P.↗

Measuring the Chemical Potential of the Martian Regolith to Generate and Sustain Life

A critical component for identifying chemical biosignatures is the ability to assess in-situ the potential of an aqueous geochemical environment to generate and sustain life. On Mars or other solar bodies, in-situ chemical characterization could provide evidence as to whether the chemical composition of the regolith or evaporites in suspected ancient water bodies have been biologically influenced or possess the chemical parameters within which life may have existed, or may still exist. A variety of analytical techniques have been proposed for use in detecting and identify signatures of past or present life. These techniques fall into two groups; visual observation with instruments such as cameras or optical/atomic-force microscopes; or elemental chemical analysis with such instruments as X-ray fluorescence (XRF) and diffraction (XRD), a-proton backscatter (APX), y-ray, Mossbauer, Raman, IR, UV/VIS spectroscopies, gas chromatography (GC), or mass spectrometry (MS). Direct observation of an identifiable lifeform by the first set of instruments in a single sample is highly unlikely, especially for extinct organisms or on the surface. The later instruments can provide vital data as to the elemental mineralogy and geological history of the planet, but are highly inadequate for understanding the chemistry of the planet in terms of indigenous life or interactions with human explorers. Techniques such as XRD, XRF, and APX, provide elemental composition at high limits of detection. Some of this data can be extrapolated or interpolated to provide chemical parameters such as oxidation state or composition. Gas chromatography (GC) without standards and non-specific detectors, has little chance of identifying a mixture of unknown components. Combined with GC or by itself, mass spectrometry (MS) can provide identification of compounds, but in both cases the sample must be appropriately prepared for accurate and reliable analysis. Life as we know it, and probably identify it as such, requires an aqueous environment. Deciphering die chemical speciation of this aqueous environment is the key to recognizing therein the biosignatures of any extinct or present life forms. Identifying the soluble (ionic and nonionic) components by reacting a currently dormant environment can provide a "picture" of the thermodynamics and chemical components of a possibly bioactive environment. The only devices which can provide such information are electrochemical sensors based on the potentiometric ion selective electrodes (ISEs) and on dynamic techniques such as cyclic voltammetry (CV) and stripping voltammetry (SV). Such an array of devices can provide not only the chemical composition of a water-soluble Martian soil sample, but also several other vital chemical parameters such as pH, conductivity, redox potential, and dissolved gases. To address these issues we have been investigating the possible use of an electrochemically-based ion sensor array as a new integrated approach to quantitative analytical and chemometric electrochemical measurements. The sensor array will consist of specific and semispecific ion selective and amperometric transducers, which can simultaneously and continuously identify and semiquantitatively determine over 50 organic and inorganic analytes in water-based environments. Several individual sensors, based on the same principle, have been flight-tested and have been installed as part of the MECA instrumentation on the Mars 2001 Lander for in-situ analyses. However, the microfabrication, integration and multiplexing of such a large number of these sensors on a single substrate have not been previously attempted.

Kounaves, S. P.↗

Raman Spectroscopy for Instantaneous Multipoint, Multispecies Gas Concentration and Temperature Measurements in Rocket Engine Propellant Injector Flows

Propellent injector development at MSFC includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will bum methane and liquid oxygen produced in-situ on Mars to reduce the propellent mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.

Wehrmeyer, Joseph A.↗

Raman Spectroscopy for Instantaneous Multipoint, Multispecies Gas Concentration and Temperature Measurements in Rocket Engine Propellant Injector Flows

Propellant injector development at MSFC includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellant mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.

Wehrmeyer, Joseph A.↗

Acousto-Optic Imaging Spectrometers for Mars Surface Science

NASA's long term plan for Mars sample collection and return requires a highly streamlined approach for spectrally characterizing a landing site, documenting the mineralogical make-up of the site and guiding the collections of samples which represent the diversity of the site. Ideally, image data should be acquired at hundreds of VIS and IR wavelengths, in order to separately distinguish numerous anticipated species, using principal component analysis and linear unmixing. Cameras with bore-sighted point spectrometers can acquire spectra of isolated scene elements, but it requires 10(exp 2) to 10(exp 2) successive motions and precise relative pointing knowledge in order to create a single data cube which qualifies as a spectral map. These and other competing science objectives have to be accomplished within very short lander/rover operational lifetime (a few sols). True, 2-D imaging spectroscopy greatly speeds up the data acquisition process, since the spectra of all pixels in the scene are collected at once. This task can be accomplished with cameras that use electronically tunable acousto-optic tunable filters (AOTFs) as the optical tuning element. AOTFs made from TeO2 are now a mature technology, and operate at wavelengths from near-UV to about 5 microns. Because of incremental improvements in the last few years, present generation devices are rugged, radiation-hard and operate at temperatures down to at least 150K so they can be safely integrated into the ambient temperature optics of in-situ instruments such as planetary or small-body landers. They have been used for ground-based astronomy, and were also baselined for the ST-4 Champollion IR comet lander experiment (CIRCLE), prior to cancellation of the ST-4 mission last year. AIMS (for Acousto-optic Imaging spectrometer), is a prototype lander instrument which is being built at GSFC with support by the NASA OSS Advanced Technologies and Mission Studies, Mars Instrument Definition and Development Program (MIDP). AIMS is capable of tunable spectroscopic imaging of surface mineralogy, ices and dust between 0.5 and 2.4 microns, at a resolving power (lambda/delta lambda) which is typically several hundred. The design spatial resolution, similar to IMP and SSI, will allow mapping at scales down to about 1 cm.

Glenar, D. A.↗

Backscatter Mossbauer Spectrometer (BaMS) for extraterrestrial applications

Mossbauer spectroscopy is a nuclear gamma resonance technique particularly well suited to the study of materials that contain iron (Fe-57). It can provide information on the oxidation state of iron as well as the type and proportion of iron-containing mineral species in a sample of interest. Iron Mossbauer spectroscopy (FeMS) has been applied to samples believed to have come from Mars (SNC meteorites) and has been helpful in refining the choice among putative Martian surface materials by suggesting a likely nanophase component of the Martian regolity. FeMS spectrum of a Martial analogue material (Hawaiian palagonite) is shown; it is dominated by ferric-bearing phases and shows evidence of a nanophase component. FeMS has also been applied to lunar materials. It can be used to measure the maturity of lunar surface material and has been proposed as a prospector for lunar ilmenite, an oxygen resource mineral. Several years ago we suggested a backscatter Mossbauer spectrometer (BaMS) for a Mars rover mission. Backscatter design was selected as most appropriate for in-situ application because no sample preparation is required. Since that time, we have continued to develop the BaMS instrument in anticipation that it would eventually find a home on a NASA planetary mission. Gooding proposed BaMS as a geochemistry instrument on MESUR. More recently, an LPI workshop has recommended that BaMS be included in a three-instrument payload on the next (1996?) lunar lander.

Agresti, D. G.↗

Mechanisms of ilmenite reduction and their impact on the design of effective reactor systems

One of the first activities at a lunar base could be oxygen recovery from ilmenite (FeTiO3). Oxygen produced from lunar soils could be used to fuel transportation vehicles operating in near-earth space. The first step in developing a suitable reactor system for lunar operation is to determine the mechanisms and rates of oxygen removal from ilmenite. In-situ gravimetric measurements and microscopic examinations were used to determine the hydrogen reduction mechanisms of synthetic ilmenite discs between 823 to 1353 K. A shrinking core reaction model, modified to account for the growth of an iron film on the surface of discs, was capable of predicting experimentally observed conversion-time relationships. The observed reduction mechanism, kinetic rates, and associated activation energy established a base line from which comparisons could be made to improve oxygen yield and removal rates. One proposed technique to improve the rate and extent of oxygen removal was to preoxidize ilmenite. Preoxidation is commonly used during the reduction of ilmenite ores in the iron industry and has been employed for many years to lower operating temperatures and increase reduction rates. This technology could prove beneficial for oxygen production facilities on the Moon as less massive reactor vessels and/or less energy could be associated with a process including preoxidation. X ray diffraction and energy dispersive spectroscopy were utilized to follow the progression of ilmenite oxidation at 1123 and 1140 K and the reduction of pseudobrookite (Fe2TiO5) at 873 and 973 K. Structures formed during the progress of oxidation were related to the system's phase diagrams. Results indicated that after initially producing ilmenite-hematite solutions and rutile (TiO2), pseudobrookite was the end product of oxidation at all temperatures examined (1049 to 1273 K). Initial results from the reduction of pseudobrookite indicate a series of phases are produced including ferropseudobrookite (FeTi2O5), ulvospinel (Fe2TiO4), and ilmenite. Rates of pseudobrookite reduction were typically 50 to 200 times that of ilmenite.

Briggs, R. A.↗

Integrating remote sensing techniques at Cuprite, Nevada: AVIRIS, Thematic Mapper, and field spectroscopy

The Cuprite mining district in southwestern Nevada has become a test site for remote sensing studies with numerous airborne scanners and ground sensor data sets collected over the past fifteen years. Structurally, the Cuprite region can be divided into two areas with slightly different alteration and mineralogy. These zones lie on either side of a postulated low-angle structural discontinuity that strikes nearly parallel to US Route 95. Hydrothermal alternation at Cuprite was classified into three major zones: silicified, opalized, and argillized. These alteration types form a bulls-eye pattern east of the highway and are more linear on the west side of the highway making a striking contrast from the air and the imagery. Cuprite is therefore an ideal location for remote sensing research as it exhibits easily identified hydrothermal zoning, is relatively devoid of vegetation, and contains a distinctive spectrally diagnostic mineral suite including the ammonium feldspar buddingtonite, several types of alunite, different jarosites, illite, kaolinite, smectite, dickite, and opal. This present study brings a new dimension to these previous remote sensing and ground data sets compiled for Cuprite. The development of a higher resolution field spectrometer now provides the capability to combine extensive in-situ mineralogical data with a new geologic field survey and detailed Airborne Visible/Infrared Imaging Spectrometers (AVIRIS) images. The various data collection methods and the refinement of the integrated techniques are discussed.

Hill, Bradley↗

Evaluating Crystallinity in Thermoplastic Composites for Aerospace Applications

Polymer matrix composites (PMCs) offer many benefits for the aerospace industry due to their potential for weight reduction when compared to metal or ceramic based materials. Most PMCs currently in flight use thermoset matrices, however, thermoplastic resins are being explored as alternatives due to their ability to be remelted, which is of particular interest due to the potential for in-situ repair and faster production. Most thermoplastic resins are semicrystalline polymers. The properties of semicrystalline thermoplastics are directly influenced by their crystallinity, which can vary due to many factors including thermal treatments, environmental conditions, and mechanical deformation. Within thermoplastic PMC parts, crystallinity gradients can arise due to variations in part geometry, across part thicknesses, and along bonded joints. Monitoring the crystallinity of thermoplastic composites is key to ensuring these materials meet the high demands required for aerospace. Several different analytical techniques exist that can be used to characterize the bulk crystallinity of thermoplastic materials. However, many existing methods lack the specificity required to identify the subtle variations in crystallinity that may play a significant role in the performance and durability of PMC parts. Because of this, a significant amount of work is still required to fully characterize and understand the crystallinity profiles of thermoplastic PMCs and the resulting impact to material properties. This talk discusses the use of multiple techniques such as Differential Scanning Calorimetry, Polarized Light Optical Microscopy, and Fourier-Transform Infrared Spectroscopy to characterize the crystallinity in carbon fiber/thermoplastic composites. Samples of different crystallinity profiles were manufactured using various cooling procedures. This work aims to provide the fundamental data necessary to understand the effects of crystallinity on thermoplastic PMCs, which is key to advancing their use in aerospace applications.

Thermoplastics↗

MEAD In-situ Sampling and Testing at Haughton Crater

The Mars Exploration through Analog-site Drilling (MEAD) project is designed to demonstrate the feasibility and scientific value of robotic drilling missions to Mars in the search for evidence of past or extant life. MEAD conducts high-fidelity field simulations integrating drilling, autonomous operations, and in-situ life-detection and mineralogical instruments. The project tests the Signs of Life Detector (SOLID), proposed for the 2019 Discovery Mars Icebreaker mission, and ARIA (Astronaut Raman Instrument for ISRU and Astrobiology), which provides mineral identification and detects trace organics and volatiles, including indicators of organic thermal maturity. Because current and planned Mars drilling missions operate largely “blind,” MEAD also evaluates the use of drill-induced vibrations recorded by deployed geophones to enable local subsurface mapping for improved targeting of drilling and sampling. In August 2025, MEAD completed its first-year field deployment to Haughton Crater in the Canadian High Arctic, an established Mars impact-crater terrestrial analog site, bringing a Honeybee Robotics TRIDENT drill with applied automation, alongside ARIA, SOLID, and FleetSpace geophones.

Haughton Crater↗