Search NASA⌕ Search

SEARCH · Search NASA

Results for “incident visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Clinical Outcomes and Late Endocrine, Neurocognitive, and Visual Profiles of Proton Radiation for Pediatric Low-Grade Gliomas

Purpose/Objective(s): Primary low-grade gliomas are common brain tumors of childhood, many of which require radiation therapy (RT) as definitive treatment. Increased conformality of RT could decrease the incidence and severity of late effects. We report our experience with 32 pediatric patients treated with proton RT. Methods and Materials: Thirty-two pediatric patients with low-grade gliomas of the brain or spinal cord were treated with proton RT from 1995 to 2007. Sixteen patients received at least 1 regimen of chemotherapy before definitive RT. The median radiation dose was 52.2 Gy{sub RBE} (48.6-54 Gy{sub RBE}). Results: The median age at treatment was 11.0 years (range, 2.7-21.5 years), with a median follow-up time of 7.6 years (range, 3.2-18.2 years). The 6-year and 8-year rates of progression-free survival were 89.7% and 82.8%, respectively, with an 8-year overall survival of 100%. For the subset of patients who received serial neurocognitive testing, there were no significant declines in Full-Scale Intelligence Quotient (P=.80), with a median neurocognitive testing interval of 4.5 years (range, 1.2-8.1 years) from baseline to follow-up, but subgroup analysis indicated some significant decline in neurocognitive outcomes for young children (<7 years) and those with significant dose to the left temporal lobe/hippocampus. The incidence of endocrinopathy correlated with a mean dose of ≥40 Gy{sub RBE} to the hypothalamus, pituitary, or optic chiasm. Stabilization or improvement of visual acuity was achieved in 83.3% of patients at risk for radiation-induced injury to the optic pathways. Conclusions: This report of late effects in children with low-grade gliomas after proton RT is encouraging. Proton RT appears to be associated with good clinical outcome, especially when the tumor location allows for increased sparing of the left temporal lobe, hippocampus, and hypothalamic-pituitary axis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Broken symmetries associated with a Kagome chiral charge order

Chirality, or handedness, is ubiquitous in science, from cell biology to physics, and in condensed matter can underlie exotic phases such as chiral charge density waves and chiral superconductivity. However, detecting subtle broken symmetries that define such states is challenging, leading to debate and controversy. Here, using second-order optical response, we reveal the broken symmetries of a chiral charge density wave in the Kagome lattice KV 3 Sb 5 . Polarization-dependent mid-infrared photocurrent microscopy uncovers a longitudinal, helicity-dependent photocurrent associated with the charge order, indicating broken inversion and mirror symmetries. These findings, supported by theoretical analysis, directly establish the intrinsic chiral nature of the ordered state. Moreover, the absence of a circular photogalvanic effect perpendicular to the incident light imposes stringent constraints on the point-group symmetries. Our study not only visualizes the chiral nature of the Kagome charge order, but also highlights the nonlinear photogalvanic effect as a sensitive probe for detecting subtle symmetry breakings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct observation of a resolvable spin separation in the spin Hall effect of light at an air-glass interface

We theoretically and experimentally demonstrate that it is possible to directly observe the resolvable spin separation in the spin Hall effect of light at an air-glass interface by choosing optimal parameters. When a P-polarized light with a beam waist of 10 μm is incident around Brewster's angle, the two spin components of the reflected beam can be completely separated by eliminating the influence of the in-plane wavevector spread. This not only obviously reveals the strong impacts of the polarization state, the incident angle, the beam waist, and the in-plane wavevector spread, but also intuitively visualizes the observation of the spin Hall effect of light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retinal Embolization During Carotid Angioplasty and Stenting: Periprocedural Data and Follow-Up

The purpose of this study was to prospectively evaluate the incidence of retinal emboli during carotid angioplasty and stenting (CAS) and to correlate emboli with clinical findings and transcranial Doppler (TCD)-detected cerebral embolic load. Between 2001 and 2005, 33 CAS procedures in 32 patients (23 [72%] male, 19 [58%] symptomatic, mean age 72.5 years [range 54.6 to 83.9]) scheduled for CAS were included in this study. Bilateral fundoscopy with retinal photography was performed by an experienced ophthalmologist immediately before, immediately after (fundoscopy only), and 1 day after the procedure and again at long-term follow-up (mean 37 months). Visual field testing was performed before CAS and again at long-term follow-up. TCD-detected cerebral emboli were stratified to five procedural phases: wiring, predilatation, stent placement, postdilatation, and cerebral protection device (CPD) use (if applicable). To establish correlation between TCD data and retinal embolization, Mann-Whitney test was used, and P < 0.05 was considered statistically significant. All procedures were performed successfully. In five of 33 procedures (15%), new retinal emboli were found. Two of the procedures with emboli had small retinal infarcts. Three of five were performed using CPDs versus seven of 28 that had no retinal emboli (P = not significant). Two of four patients (50%) with previous radiation therapy to the neck had new retinal emboli versus three of 29 patients (10%) who had no previous radiation therapy (P = 0.038). None of the other patient characteristics was associated with retinal embolization. In 30 (91%) of patients with an adequate acoustic temporal window for TCD monitoring, there was no statistically significant correlation between TCD data and the incidence of retinal emboli. No visual field defects were found. On long-term follow-up, all retinal emboli and retinal infarcts had resolved. Retinal embolization during CAS is not uncommon, and it occurs in both protected and unprotected procedures. Most retinal emboli are clinically silent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Chemical Incident Response Plan (ECIRP). Appendix F, remediation analysis with Decision Support Tools (DSTs) for wide-area chemical hazards.

The Defense Threat Reduction Agency (DTRA) commissioned an assessment of the Consequence Management (CM) plans in place on military bases for response to a chemical attack. The effectiveness of the CM plans for recovering from chemical incidents was modeled using a multiple Decision Support Tools (DSTs). First, a scenario was developed based on an aerial dispersion of a chemical agent over a wide-area of land. The extent of contamination was modeled with the Hazard Prediction and Assessment Capability (HPAC) tool. Subsequently, the Analyzer for Wide Area Restoration Effectiveness (AWARE) tool was used to estimate the cost and time demands for remediation based on input of contamination maps, sampling and decontamination resources, strategies, rates and costs. The sampling strategies incorporated in the calculation were designed using the Visual Sample Plan (VSP) tool. Based on a gaps assessment and the DST remediation analysis, an Enhanced Chemical Incident Response Plan (ECIRP) was developed.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Transient bow shock around a cylinder in a supersonic dusty plasma

Visual observations of the formation of a bow shock in the transient supersonic flow of a dusty plasma incident on a biased cylinder are presented. The bow shock formed when the advancing front of a streaming dust cloud was reflected by the obstacle. After its formation, the density jump of the bow shock increased as it moved upstream of the obstacle. A physical picture for the formation of the electrohydrodynamic bow shock is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE DARK MOLECULAR GAS

The mass of molecular gas in an interstellar cloud is often measured using line emission from low rotational levels of CO, which are sensitive to the CO mass, and then scaling to the assumed molecular hydrogen H{sub 2} mass. However, a significant H{sub 2} mass may lie outside the CO region, in the outer regions of the molecular cloud where the gas-phase carbon resides in C or C{sup +}. Here, H{sub 2} self-shields or is shielded by dust from UV photodissociation, whereas CO is photodissociated. This H{sub 2} gas is 'dark' in molecular transitions because of the absence of CO and other trace molecules, and because H{sub 2} emits so weakly at temperatures 10 K <T < 100 K typical of this molecular component. This component has been indirectly observed through other tracers of mass such as gamma rays produced in cosmic-ray collisions with the gas and far-infrared/submillimeter wavelength dust continuum radiation. In this paper, we theoretically model this dark mass and find that the fraction of the molecular mass in this dark component is remarkably constant ({approx}0.3 for average visual extinction through the cloud A-bar{sub V{approx_equal}}8) and insensitive to the incident ultraviolet radiation field strength, the internal density distribution, and the mass of the molecular cloud as long as A-bar{sub V}, or equivalently, the product of the average hydrogen nucleus column and the metallicity through the cloud, is constant. We also find that the dark mass fraction increases with decreasing A-bar{sub V}, since relatively more molecular H{sub 2} material lies outside the CO region in this case.

79 ASTRONOMY AND ASTROPHYSICS↗

Angle-resolved pair photoemission theory for correlated electrons

Here in this paper we consider the possibility and conditions for pair photoemission whereby two incident photons emit pairs of electrons from a candidate material as a novel method to measure and visualize electronic correlations. As opposed to double photoemission - where a single photon precipitates the ejection of a pair electrons via a subsequent electron energy loss scattering process - we show that pair photoemission need not be limited to interference between initial photoelectrons and valence electrons, and moreover, can occur without the energy penalty of two work functions. This enables detection of pairs of electrons at high energy resolution that may be correlated in the same quantum many-body states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ILLICIT TRANSIT INTERDICTION GLOBAL ANALYSIS

This study aims to enhance the security of radioactive materials during transport by analyzing commonalities in cargo thefts conducted by non-state groups such as thieves and terrorists. This research focuses on identifying patterns and trends in the methods used to steal high-value cargo, with the goal of applying these insights to improve transport security of radioactive materials. Key questions addressed include the frequency of specific tools, techniques, and insider involvement in thefts, as well as the use of weapons, electronic jamming equipment, and specialized tools. Findings will inform security design improvements and industry practices to mitigate vulnerabilities. The study involves a comprehensive review of literature and case studies, utilizing data sources from 2018 to 2023. Articles will be selected based on their relevance to thefts of valuable cargo in transit, with a focus on incidents involving non-state actors. The methodology will include statistical and inferential analysis to identify trends, with results visualized through pie charts, frequency analyses, and terrain maps. The discussion will highlight the implications of findings and provide actionable recommendations for strengthening security measures. Limitations such as data availability and reporting inconsistencies will be acknowledged. Suggestions for future improvements will be constructed using existing case studies and expert feedback. The study’s outcomes aim to raise awareness within the industry, inform policy decisions, and enhance security protocols for radioactive material transport. Metrics for impact include the potential publication of findings, presentations at conferences to raise awareness, and the subsequent actions taken by stakeholders based on the research. By identifying trends and vulnerabilities and suggesting improvements, this research contributes to preventing the illicit use of nuclear and radiological materials.

Zineddin, Dr. Z. [ORNL] (ORCID:0009000848740725)↗

Image quality evaluation of breast tomosynthesis with synchrotron radiation

Purpose: This study investigates the image quality of tomosynthesis slices obtained from several acquisition sets with synchrotron radiation using a breast phantom incorporating details that mimic various breast lesions, in a heterogeneous background. Methods: A complex Breast phantom (MAMMAX) with a heterogeneous background and thickness that corresponds to 4.5 cm compressed breast with an average composition of 50% adipose and 50% glandular tissue was assembled using two commercial phantoms. Projection images using acquisition arcs of 24 Degree-Sign , 32 Degree-Sign , 40 Degree-Sign , 48 Degree-Sign , and 56 Degree-Sign at incident energy of 17 keV were obtained from the phantom with the synchrotron radiation for medical physics beamline at ELETTRA Synchrotron Light Laboratory. The total mean glandular dose was set equal to 2.5 mGy. Tomograms were reconstructed with simple multiple projection algorithm (MPA) and filtered MPA. In the latter case, a median filter, a sinc filter, and a combination of those two filters were applied on the experimental data prior to MPA reconstruction. Visual inspection, contrast to noise ratio, contrast, and artifact spread function were the figures of merit used in the evaluation of the visualisation and detection of low- and high-contrast breast features, as a function of the reconstruction algorithm and acquisition arc. To study the benefits of using monochromatic beams, single projection images at incident energies ranging from 14 to 27 keV were acquired with the same phantom and weighted to synthesize polychromatic images at a typical incident x-ray spectrum with W target. Results: Filters were optimised to reconstruct features with different attenuation characteristics and dimensions. In the case of 6 mm low-contrast details, improved visual appearance as well as higher contrast to noise ratio and contrast values were observed for the two filtered MPA algorithms that exploit the sinc filter. These features are better visualized at extended arc length, as the acquisition arc of 56 Degree-Sign with 15 projection images demonstrates the highest image reconstruction quality. For microcalcifications, filtered MPA implemented with a combination of median and sinc filters indicates better feature appearance due to efficient suppression of background tissue. The image quality of these features is less sensitive to the acquisition arc. Calcifications with size ranging from 170 to 500 {mu}m, like the ones presently studied, are well identified and visualized for all arcs used. The comparison of single projection images obtained under different beam conditions showed that the use of monochromatic beam can produce an image with higher contrast and contrast to noise ratio compared to an image corresponding to a polychromatic beam even when the latter is acquired with double incident exposure. Conclusions: Filter optimization in respect to the type of feature characteristics is important before the reconstruction. The MPA combined with median and sinc filters results in improved reconstruction of microcalcifications and low-contrast features. The latter are better visualized at extended arc length, while microcalcifications are less sensitive to this acquisition parameter. Use of monochromatic beams may result in tomographic images with higher contrast acquired at lower incident exposures.

60 APPLIED LIFE SCIENCES↗

Multi-line FLEET by imaging periodic masks

A simple linear configuration for multi-line FLEET velocimetry is used for the first time to image an overexpanded unsteady supersonic jet. The FLEET lines are spaced 0.5-1.0 mm apart and up to six lines can simultaneously be used to visualize the flowfield. These lines are created using periodic masks, despite the mask blocking 25 — 30% of the 10 mJ incident beam. Maps of mean single-component velocity in the direction along the principal flow axis, and turbulence intensity in that same direction, are created using multi-line FLEET, and computed velocities agree well with that obtained from single-line (traditional) FLEET. Compared to traditional FLEET, multi-line FLEET offers increased simultaneous spatial coverage and the ability to produce spatial correlations in the streamwise direction. This FLEET permutation is especially well-suited for short-duration test facilities

42 ENGINEERING↗

Validation of the Mach Stem Triple Point

Among the more complex characteristics of an explosion’s shock front is the creation of the Mach stem and its triple point. The scientific footage of the US Atmospheric Nuclear Weapons Testing Program has a film that may show the locus of points formed by the triple point, allowing us to visually investigate the trajectory of these shockwaves. During a nuclear blast, once the X-ray diffusion process ends, an incident shockwave forms in all directions. When the incident shockwave contacts the ground, a reflected shockwave is created. The overall magnitude and impact of these two shockwaves are proportional to the increasing total pressure and temperature, allowing the disturbances to move faster than the local speed of sound.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development & Optimization of Materials and Processes for a Cost Effective Photoelectrochemical Hydrogen Production System. Final report

The overall project objective was to apply high throughput experimentation and combinatorial methods together with novel syntheses to discover and optimize efficient, practical, and economically sustainable materials for photoelectrochemical production of bulk hydrogen from water. Automated electrochemical synthesis and photoelectrochemical screening systems were designed and constructed and used to study a variety of new photoelectrocatalytic materials. We evaluated photocatalytic performance in the dark and under illumination with or without applied bias in a high-throughput manner and did detailed evaluation on many materials. Significant attention was given to -Fe2O3 based semiconductor materials and thin films with different dopants were synthesized by co-electrodeposition techniques. Approximately 30 dopants including Al, Zn, Cu, Ni, Co, Cr, Mo, Ti, Pt, etc. were investigated. Hematite thin films doped with Al, Ti, Pt, Cr, and Mo exhibited significant improvements in efficiency for photoelectrochemical water splitting compared with undoped hematite. In several cases we collaborated with theorists who used density functional theory to help explain performance trends and suggest new materials. The best materials were investigated in detail by X-ray diffraction (XRD), scanning electron microscopy (SEM), ultraviolet-visual spectroscopy (UV-Vis), X-ray photoelectron spectroscopy (XPS). The photoelectrocatalytic performance of the thin films was evaluated and their incident photon

08 HYDROGEN↗

Information Technology and Community Restoration Studies/Task 1: Information Technology

Executive Summary The Interagency Biological Restoration Demonstration—a program jointly funded by the Department of Defense's Defense Threat Reduction Agency and the Department of Homeland Security's (DHS's) Science and Technology Directorate—is developing policies, methods, plans, and applied technologies to restore large urban areas, critical infrastructures, and Department of Defense installations following the intentional release of a biological agent (anthrax) by terrorists. There is a perception that there should be a common system that can share information both vertically and horizontally amongst participating organizations as well as support analyses. A key question is: "How far away from this are we?" As part of this program, Pacific Northwest National Laboratory conducted research to identify the current information technology tools that would be used by organizations in the greater Seattle urban area in such a scenario, to define criteria for use in evaluating information technology tools, and to identify current gaps. Researchers interviewed 28 individuals representing 25 agencies in civilian and military organizations to identify the tools they currently use to capture data needed to support operations and decision making. The organizations can be grouped into five broad categories: defense (Department of Defense), environmental/ecological (Environmental Protection Agency/Ecology), public health and medical services, emergency management, and critical infrastructure. The types of information that would be communicated in a biological terrorism incident include critical infrastructure and resource status, safety and protection information, laboratory test results, and general emergency information. The most commonly used tools are WebEOC (web-enabled crisis information management systems with real-time information sharing), mass notification software, resource tracking software, and NW WARN (web-based information to protect critical infrastructure systems). It appears that the current information management tools are used primarily for information gathering and sharing—not decision making. Respondents identified the following criteria for a future software system. It is easy to learn, updates information in real time, works with all agencies, is secure, uses a visualization or geographic information system feature, enables varying permission levels, flows information from one stage to another, works with other databases, feeds decision support tools, is compliant with appropriate standards, and is reasonably priced. Current tools have security issues, lack visual/mapping functions and critical infrastructure status, and do not integrate with other tools. It is clear that there is a need for an integrated, common operating system. The system would need to be accessible by all the organizations that would have a role in managing an anthrax incident to enable regional decision making. The most useful tool would feature a GIS visualization that would allow for a common operating picture that is updated in real time. To capitalize on information gained from the interviews, the following activities are recommended: • Rate emergency management decision tools against the criteria specified by the interviewees. • Identify and analyze other current activities focused on information sharing in the greater Seattle urban area. • Identify and analyze information sharing systems/tools used in other regions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Dry Eye Syndrome After Proton Therapy of Ocular Melanomas

Purpose: To investigate whether proton therapy (PT) performs safely in superotemporal melanomas, in terms of risk of dry-eye syndrome (DES). Methods and Materials: Tumor location, DES grade, and dose to ocular structures were analyzed in patients undergoing PT (2005-2015) with 52 Gy (prescribed dose, not accounting for biologic effectiveness correction of 1.1). Prognostic factors of DES and severe DES (sDES, grades 2-3) were determined with Cox proportional hazard models. Visual acuity deterioration and enucleation rates were compared by sDES and tumor locations. Results: Median follow-up was 44 months (interquartile range, 18-60 months). Of 853 patients (mean age, 64 years), 30.5% had temporal and 11.4% superotemporal tumors. Five-year incidence of DES and sDES was 23.0% (95% confidence interval [CI] 19.0%-27.7%) and 10.9% (95% CI 8.2%-14.4%), respectively. Multivariable analysis showed a higher risk for sDES in superotemporal (hazard ratio [HR] 5.82, 95% CI 2.72-12.45) and temporal tumors (HR 2.63, 95% CI 1.28-5.42), age ≥70 years (HR 1.90, 95% CI 1.09-3.32), distance to optic disk ≥5 mm (HR 2.71, 95% CI 1.52-4.84), ≥35% of retina receiving 12 Gy (HR 2.98, 95% CI 1.54-5.77), and eyelid rim irradiation (HR 2.68, 95% CI 1.49-4.80). The same risk factors were found for DES. Visual acuity deteriorated more in patients with sDES (0.86 ± 1.10 vs 0.64 ± 0.98 logMAR, P=.034) but not between superotemporal/temporal and other locations (P=.890). Enucleation rates were independent of sDES (P=.707) and tumor locations (P=.729). Conclusions: Severe DES was more frequent in superotemporal/temporal melanomas. Incidence of vision deterioration and enucleation was no higher in patients with superotemporal melanoma than in patients with tumors in other locations. Tumor location should not contraindicate PT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MQXFA11 shipping incident report

The truck transporting the MQXFA11 magnet from LBNL to BNL was involved in an accident on 7/20/22. It was rear ended by another truck. The magnet arrived at FNAL on July 28th. Upon arrival a visual inspection was performed. Accelerometers were removed and shock data were analyzed. Electrical checkout and a metrology survey were carried out. Strain data were also collected from the fiber optics installed on two coils and compared with data obtained before shipment. This report presents a summary of results.

43 PARTICLE ACCELERATORS↗