Search NASA⌕ Search

SEARCH · Search NASA

Results for “inductive inserts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detection of air-gap eccentricity and broken-rotor bar conditions in a squirrel-cage induction motor using the radial flux sensor

A new method for detecting eccentricity and broken rotor bar conditions in a squirrel-cage induction motor is proposed. Air-gap flux variation analysis is done using search coils, which are inserted at stator slots. Using this method, the leakage flux in radial direction can be directly detected. Using finite element method, the air-gap flux variation is accurately modeled and analyzed. From the results of the simulation, a motor under normal condition shows maximum magnetic flux density of 1.3 T. On the other hand, the eccentric air-gap condition displays about 1.1 T at 60 deg. and 1.6 T at 240 deg. A difference of flux density is 0.5 T in the abnormal condition, whereas no difference is detected in the normal motor. In the broken rotor bar conditions, the flux densities at 65 deg. and 155 deg. are about 0.4 T and 0.8 T, respectively. These simulation results are coincided with those of experiment. Consequently, the measurement of the magnetic flux at air gap is one of effective ways to discriminate the faulted conditions of the eccentricity and broken rotor bars.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of Roller Sliding in Wind Turbine Gearbox High-Speed-Shaft Bearings

In a collaborative project, Flender Corporation, SKF, and the National Renewable Energy Laboratory (NREL) have instrumented a commercial drivetrain, installed it in a wind turbine at the National Wind Technology Center, and operated the turbine for more than a year. The gearbox was specifically instrumented to measure high-speed bearing loads, sliding, and the lubricant environment. Commercial SKF black-oxide coated cylindrical-roller bearings were modified by magnetizing one roller and inserting a metal pin in the cage next to it to measure roller and cage speed, respectively, with an inductive coil and a proximity switch. In this report, these measurements are used to validate two different modeling approaches for bearing sliding - one analytical dynamic model and one multibody model. Once validated, these models can be used to evaluate the roller slip losses or cumulative frictional energy that are considered potential driving factors for wind turbine gearbox high-speed-shaft and high intermediate speed shaft bearing failures by white etching cracks.

17 WIND ENERGY↗

Tests on the extracted current density of negative hydrogen ions from a single element of the matrix source

Concepts for the extraction of volume-produced negative hydrogen ions from a rf matrix source (a matrix of small-radius discharges with a planar-coil inductive driving) are presented and discussed based on experimental results for the current densities of the extracted ions and the co-extracted electrons. The experiment has been carried out in a single discharge of the source: a rf discharge with a radius of 2.25 cm inductively driven by a 3.5-turn planar coil. The length of the discharge tube, the area of the reference electrode inserted in the discharge volume, the discharge modes, the magnetic filter and its position along the discharge length, the position of the permanent magnets for the separation of the co-extracted electrons from the extracted ions in the extraction device and the bias applied to its first electrode are considered as factors influencing the extracted currents of negative ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a novel keratinocyte-based reporter cell line to screen skin sensitizers in vitro

In vitro tests are needed to replace animal tests to screen for the skin sensitization potential of chemicals. Skin sensitizers are electrophilic molecules and the Nrf2-electrophile-sensing pathway comprising the repressor protein Keap1, the transcription factor Nrf2 and the antioxidant response element (ARE) is emerging as a toxicity pathway induced by skin sensitizers. Previously, we screened a large set of chemicals in the reporter cell line AREc32, which contains an eight-fold repeat of the rat GSTA2 ARE-sequence upstream of a luciferase reporter gene in the human breast cancer cell line MCF7. This approach was now further developed to bring it closer to the conditions in the human skin and to propose a fully standardized assay. To this end, a luciferase reporter gene under control of a single copy of the ARE-element of the human AKR1C2 gene was stably inserted into HaCaT keratinocytes. A standard operating procedure was developed whereby chemicals are routinely tested at 12 concentrations in triplicate for significant induction of gene activity. We report results from this novel assay on (i) a list of reference chemicals published by ECVAM, (ii) the ICCVAM list of chemicals for validation of alternative endpoints in the LLNA and (iii) on a more general list of 67 chemicals derived from the ICCVAM database. For comparison, peptide reactivity data are presented for the same chemicals. The results indicate a good predictive value of this approach for hazard identification. Its technical simplicity, the high-throughput format and the good predictivity may make this assay a candidate for rapid validation to meet the tight deadline to replace animal tests for skin sensitization by 2013 set by the European authorities.

60 APPLIED LIFE SCIENCES↗

Isolation of a novel protein phosphatase2C in rice and its response to gibberellin

Highlights: • OsPP2C34 is highly inducible by gibberellin (GA) and expressed in various tissues. • OsPP2C34 is localized to the cytosol and involved in α-amylase genes inducible by GA. • OsPP2C34 has dephosphorylation activity at its serine/threonine residues. • OsPP2C34 is a positive regulator of the GA-dependent signaling transduction pathway. Protein phosphatase 2Cs (PP2Cs) have been referred to act as negative modulators of the protein kinase pathways involved in different environmental stress responses and developmental processes. In Arabidopsis, PP2Cs have been extensively studied and some are known to negatively regulate abscisic acid signaling. In rice, PP2Cs are scarcely characterized functionally. Here, we identified a novel PP2C from rice (OsPP2C34), which is highly inducible by gibberellin (GA) and expressed in various tissues. Subcellular localization analysis in maize protoplasts using a green fluorescence protein fusion vector localized OsPP2C34 to the cytosol. Genetic analysis of T-DNA insertional mutants revealed that plant height and internode length were significantly shorter in mutants than in corresponding wild types under GA treatment. The induction of the GA-inducibleα-amylase genes RAmy3E and OsAmy was delayed in mutant plants. The substrate of OsPP2C34 was identified by immunoblotting using anti serine/threonine antibodies. A 65 kDa protein was phosphorylated in Ospp2c34-1 but dephosphorylated in the wild type during early germination stage. Overall, the present results indicated that OsPP2C34 is involved inα-amylase expression of GA signal transduction pathway.

60 APPLIED LIFE SCIENCES↗

Simulated Impact of Shortened Strings in Commercial and Utility-Scale Photovoltaic Arrays

The deliberate removal of photovoltaic modules from a string can occur for various reasons encompassing maintenance, measurements, theft, or failure, reducing that string length relative to others when replacement modules are not available and there are not any viable alternative makes and models that could be inserted. This phenomenon, delineated in our prior experimentally validated research, manifests two significant effects: (1) a shift in the ideal maximum power point and (2) the induction of potentially substantial reverse currents in the shortened strings at open-circuit voltage, VOC. However, the scalability and asymptotic limits of these observed behaviors concerning array size remained undetermined. In this study, we elucidate the operational dynamics of such arrays by manipulating two mismatch-contributing variables in simulated arrays of up to 900 strings: the number of removed modules per string (indicative of the level of mismatch, ranging up to 5) and the quantity of shortened strings (1 to 60). Simulation outcomes underscore that mismatch severity impacts array operation more than the proportion of shortened strings. This research delves into the practical ramifications of operating with shortened strings, including implications for low-irradiance operation and the manifestation of deleterious reverse currents (>35 A in specific cases), emphasizing the need for careful array configuration for optimal performance and safety in these implementations.

Energy & Fuels↗

Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniaturized Multi-Band Antenna via Element Collocation

The resonant frequency of a microstrip patch antenna may be reduced through the addition of slots in the radiating element. Expanding upon this concept in favor of a significant reduction in the tuned width of the radiator, nearly 60% of the antenna metallization is removed, as seen in the top view of the antenna’s radiating element (shown in red, below, left). To facilitate an increase in the gain of the antenna, the radiator is suspended over the ground plane (green) by an air substrate at a height of 0.250" while being mechanically supported by 0.030" thick Rogers RO4003 laminate in the same profile as the element. Although the entire surface of the antenna (red) provides 2.45 GHz operation with insignificant negative effects on performance after material removal, the smaller square microstrip in the middle must be isolated from the additional aperture in order to afford higher frequency operation. A low insertion loss path centered at 2.45 GHz may simultaneously provide considerable attenuation at additional frequencies through the implementation of a series-parallel, resonant reactive path. However, an inductive reactance alone will not permit lower frequency energy to propagate across the intended discontinuity. To mitigate this, a capacitance is introduced in series with the inductor, generating a resonance at 2.45 GHz with minimum forward transmission loss. Four of these reactive pairs are placed between the coplanar elements as shown. Therefore, the aperture of the lower-frequency outer segment includes the smaller radiator while the higher frequency section is isolated from the additional material. In order to avoid cross-polarization losses due to the orientation of a transmitter or receiver in reference to the antenna, circular polarization is realized by a quadrature coupler for each collocated antenna as seen in the bottom view of the antenna (right). To generate electromagnetic radiation concentrically rotating about the direction of propagation, ideally one-half of the power must be delivered to the output of each branch with a phase shift of 90 degrees and identical amplitude. Due to this, each arm of the coupler is spaced λ/4 wavelength apart.

42 ENGINEERING↗

Low-Oxygen Induction of Normally Cryptic psbA Genes in Cyanobacteria

Microarray analysis indicated low-O₂ conditions resulted in upregulation of psbA1, the normally low-abundance transcript that encodes the D1' protein of photosystem II in Synechocystis sp. PCC 6803. Using a ΔpsbA2:ΔpsbA3 strain, we show the psbA1 transcript is translated and the resultant D1' is inserted into functional PSII complexes. Two other cyanobacterial strains have psbA genes that were induced by low oxygen. In two of the three strains examined, psbA was part of an upregulated gene cluster including an alternative Rieske iron-sulfur protein. We conclude this cluster may represent an important adaptation to changing O₂ levels that cyanobacteria experience.

59 BASIC BIOLOGICAL SCIENCES↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Miniaturized Multi-Band Antenna via Element Collocation

Although much research has been performed on a driven element parasitically loaded by another element shorted to ground for dual frequency operation, the novel concept of two or more coplanar-driven elements in close proximity designed for multiple frequency operation has not been represented in the literature. Since each higher frequency antenna is built into the lower frequency elements, the largest element controls the structure’s total size. Furthermore, by using the self-resonant frequency inherent in reactive elements due to device packaging, the aperture of each antenna, due to a low insertion loss path at the frequency of the larger element, will include that of all smaller radiators. This configuration provides a large standing wave ratio at the shorter wavelengths via several series capacitive-inductive connections. Therefore, each antenna element provides the required surface area for the frequency of operation while being isolated from the larger radiators. For this study, a dual 2.45/5.8 GHz microstrip patch encompasses a small surface area of 9 square inches and provides circularly polarized electromagnetic radiation in excess of 6 dBi. This concept can be extrapolated to include additional radiators or may be scaled to other frequencies of interest.

42 ENGINEERING↗

Novel 6xHis tagged foot-and-mouth disease virus vaccine bound to nanolipoprotein adjuvant via metal ions provides antigenic distinction and effective protective immunity

Here, we engineered two FMD viruses with histidine residues inserted into or fused to the FMDV capsid. Both 6xHis viruses exhibited growth kinetics, plaque morphologies and antigenic characteristics similar to wild-type virus. The 6xHis tag allowed one-step purification of the mutant virions by Co{sup 2+} affinity columns. Electron microscopy and biochemical assays showed that the 6xHis FMDVs readily assembled into antigen: adjuvant complexes in solution, by conjugating with Ni{sup 2+}-chelated nanolipoprotein and monophosphoryl lipid A adjuvant (MPLA:NiNLP). Animals Immunized with the inactivated 6xHis-FMDV:MPLA:NiNLP vaccine acquired enhanced protective immunity against FMDV challenge compared to virions alone. Induction of anti-6xHis and anti-FMDV neutralizing antibodies in the immunized animals could be exploited in the differentiation of vaccinated from infected animals needed for the improvement of FMD control measures. The novel marker vaccine/nanolipid technology described here has broad applications for the development of distinctive and effective immune responses to other pathogens of importance. - Highlights: • 6xHis-tags in A{sub 24} FMDV enable purification and biding to adjuvants via metal ions. • 6xHis A{sub 24} FMDV:MPLA:NiNLP vaccine enhanced protective immunity against FMDV. • Surface exposed capsid tags allow distinction of infected from vaccinated animals.

60 APPLIED LIFE SCIENCES↗

Final report on the Magnetized Target Fusion Collaboration

Nuclear fusion has the potential to satisfy the prodigious power that the world will demand in the future, but it has yet to be harnessed as a practical energy source. The entry of fusion as a viable, competitive source of power has been stymied by the challenge of finding an economical way to provide for the confinement and heating of the plasma fuel. It is the contention here that a simpler path to fusion can be achieved by creating fusion conditions in a different regime at small scale (~ a few cm). One such program now under study, referred to as Magnetized Target Fusion (MTF), is directed at obtaining fusion in this high energy density regime by rapidly compressing a compact toroidal plasmoid commonly referred to as a Field Reversed Configuration (FRC). To make fusion practical at this smaller scale, an efficient method for compressing the FRC to fusion gain conditions is required. In one variant of MTF a conducting metal shell is imploded electrically. This radially compresses and heats the FRC plasmoid to fusion conditions. The closed magnetic field in the target plasmoid suppresses the thermal transport to the confining shell, thus lowering the imploding power needed to compress the target. The undertaking to be described in this proposal is to provide a suitable target FRC, as well as a simple and robust method for inserting and stopping the FRC within the imploding liner. The timescale for testing and development can be rapidly accelerated by taking advantage of a new facility funded by the Department of Energy. At this facility, two inductive plasma accelerators (IPA) were constructed and tested. Recent experiments with these IPAs have demonstrated the ability to rapidly form, accelerate and merge two hypervelocity FRCs into a compression chamber. The resultant FRC that was formed was hot (T&ion ~ 400 eV), stationary, and stable with a configuration lifetime several times that necessary for the MTF liner experiments. The accelerator length was less than 1 meter, and the time from the initiation of formation to the establishment of the final equilibrium was less than 10 microseconds. With some modification, each accelerator was made capable of producing FRCs suitable for the production of the target plasma for the MTF liner experiment. Based on the initial FRC merging/compression results, the design and methodology for an experimental realization of the target plasma for the MTF liner experiment can now be defined. A high density FRC plasmoid is to be formed and accelerated out of each IPA into a merging/compression chamber similar to the imploding liner at AFRL. The properties of the resultant FRC plasma (size, temperature, density, flux, lifetime) are obtained in the reevant regime of interest. The process still needs to be optimized, and a final design for implementation at AFRL must now be carried out. When implemented at AFRL it is anticipated that the colliding/merging FRCs will then be compressed by the liner. In this manner it is hoped that ultimately a plasma with ion temperatures reaching the 10 keV range and fusion gain near unity can be obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Power measurements and coupler optimization in inductive discharges

The power absorbed by the plasma is one of the key parameters which defines processes in any plasma source. This power, however, can be very different from the power at the rf power source output or the coupler terminals, which has been used in many publications to characterize the plasma. This article describes how to find the power absorbed by the plasma and the power lost in the coupler and matcher network for inductively coupled plasmas. In addition, several practical coupler configurations to reduce the coupler coil loss and minimize the rf plasma potential are discussed. Here, we propose an effective and simple method to achieve that by the coupler coil splitting and insertion of the resonating capacitor in the middle of the coil. Our experimental data demonstrate this approach having superior coupler efficiency and substantially lower rf plasma potential.

47 OTHER INSTRUMENTATION↗

Multiple Analytical Approach to Isotopic Transport Analysis in Magnetic Fusion Devices

High-Z impurities released from plasma-material interactions have been shown to limit the performance of fusion plasmas, and understanding these impurity transport mechanisms throughout the plasma scrape-off layer is a major challenge. Presented herein is a study of tungsten (W) erosion and transport by uniquely measuring absolute quantities of isotopic W in order to determine the source of natural and enriched 182W isotopes that have traveled throughout the tokamak discharges on the DIII-D National Fusion Facility at General Atomics. Two primary analysis methods have been implemented to characterize this W on graphite collector probes that were inserted into DIII-D’s outboard midplane. Results from experiments using Rutherford backscattering spectrometry (RBS) have measured W particle areal densities down the centerline of the probes as high as 6E14 atoms/cm2 with a detection limit of 1E12 atoms/cm2. Laser ablation inductively coupled plasma mass spectrometry (LAMS) has confirmed the elemental trends found with RBS and has provided additional insight into collector probe surface profiles. Two-dimensional elemental and isotopic maps from LAMS are used to reveal new collector probe features and further refine the source of collected W. Variations in isotopic profiles and total W content are coupled to (a) the face of the probe being analyzed, (b) the dimensions of the probe, and (c) the plasma pulse parameters that were used during probe exposure. These results provide one-of-a-kind empirical evidence that is now being utilized for validation of tokamak impurity transport through theoretical models and in codes such as 3D-LIM and OEDGE.

Duran, Jonah↗

Wireless Frequency‐Multiplexed Acoustic Array‐Based Acoustofluidics

Abstract Acoustofluidics has shown great potential in enabling on‐chip technologies for driving liquid flows and manipulating particles and cells for engineering, chemical, and biomedical applications. To introduce on‐demand liquid sample processing and micro/nano‐object manipulation functions to wearable and embeddable electronics, wireless acoustofluidic chips are highly desired. This paper presents wireless acoustofluidic chips to generate acoustic waves carrying sufficient energy and achieve key acoustofluidic functions, including arranging particles and cells, generating fluid streaming, and enriching in‐droplet particles. To enable these functions, the wireless acoustofluidic chips leverage mechanisms, including inductive coupling‐based wireless power transfer (WPT), frequency multiplexing‐based control of multiple acoustic waves, and the resultant acoustic radiation and drag forces. For validation, the wirelessly generated acoustic waves are measured using laser vibrometry when different materials (e.g., bone, tissue, and hand) are inserted between the WPT transmitter and receiver. Moreover, the wireless acoustofluidic chips successfully arrange nanoparticles into different patterns, align cells into parallel pearl chains, generate streaming, and enrich in‐droplet microparticles. This research is anticipated to facilitate the development of embeddable wireless on‐chip flow generators, wearable sensors with liquid sample processing functions, and implantable devices with flow generation and acoustic stimulation abilities for engineering, veterinary, and biomedical applications.

Li, Jiali↗