Inexpensive Pressure-Relief Valve
Simple device vents excess low-pressure gas. Inexpensive pressure relief valve built from polyvinylchloride pipe. Valve suitable for low pressure-- 25 to 50 cm of mercury-- and flow rates up to 14 m3/min.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Simple device vents excess low-pressure gas. Inexpensive pressure relief valve built from polyvinylchloride pipe. Valve suitable for low pressure-- 25 to 50 cm of mercury-- and flow rates up to 14 m3/min.
Increasing performance of CPUs and memories will be squandered if not matched by a similar performance increase in I/O. While the capacity of Single Large Expensive Disks (SLED) has grown rapidly, the performance improvement of SLED has been modest. Redundant Arrays of Inexpensive Disks (RAID), based on the magnetic disk technology developed for personal computers, offers an attractive alternative to SLED, promising improvements of an order of magnitude in performance, reliability, power consumption, and scalability. This paper introduces five levels of RAIDs, giving their relative cost/performance, and compares RAID to an IBM 3380 and a Fujitsu Super Eagle.
Pyranometer generates output potential of about 300 mV in maximum sunlight. Designed to monitor insolation at accuracy within 5 percent of accuracy of instruments ordinarily used for this purpose. Suitable for use in school laboratories and perhaps in commercial facilities where expense of more precise instrument not justified. Slightly more complex pyranometer intended primarily for use in agricultural setting described in "Inexpensive Meter For Total Solar Radiation" (NPO-16741).
Direct observation of solid-liquid interface is important for the directional solidification to determine the desired interface shape by controlling the growth parameters. To grow good quality single crystals of novel organic nonlinear optical materials, a simple inexpensive Bridgman-Stockbarger (BS) crystal growth system has been designed and fabricated. Two immiscible liquids have been utilized to create two zones for this crystal growth system. Bulk single crystals of benzil derivative and n-salicylidene-aniline have been successfully grown in this system. The optimum lowering rate has been found to be 0.1 mm/h for the flat interface. Results on the crystal growth and other parameters of the grown crystals are presented.
The availability of an inexpensive chilled mirror dewpoint sensor has made improved atmospheric relative humidity measurements accessible. Comparisons between the chilled mirror sensor and routine radiosonde sensors have provided new information on the limitation and reliability of the routine measurements. The chilled mirror has observed detailed moisture profiles at cirrus cloud levels when cirrus was not visible, a feature that routine sensors fail to observe. Comparison measurements between the chilled mirror, the carbon resistive (hygristor) and, the capacitive sensors will be discussed. Measurements from three locations (Wallops Island; Andros Island, Bahamas; and Camborne, UK) will be highlighted. It is conceivable that the chilled mirror sensor, when its capability is fully understood, may be sufficiently reliable to serve as a reference.
An inexpensive method was developed for coating the interior of silica ampoules with hexagonal boron nitride. An aqueous solution of boric acid was used to coat the ampoule prior to drying in a vacuum at 200 C. This coating was converted to transparent boron nitride by heating in ammonia at 1000 C. Coated ampoules were used to achieve detached solidification of indium antimonide on earth.
It has been proposed to develop arrays of strain gauges as arrays of ordinary metal film resistors and associated electronic readout circuitry on printed circuit boards or other suitable substrates. This proposal is a by-product of a development of instrumentation utilizing metal film resistors on printed-circuit boards to measure temperatures at multiple locations. In the course of that development, it was observed that in addition to being sensitive to temperature, the metal film resistors were also sensitive to strains in the printed-circuit boards to which they were attached. Because of the low cost of ordinary metal film resistors (typically <$0.01 apiece at 2007 prices), the proposal could enable inexpensive implementation of arrays of many (e.g., 100 or more) strain gauges, possibly concentrated in small areas. For example, such an array could be designed for use as a computer keyboard with no moving parts, as a device for sensing the shape of an object resting on a surface, or as a device for measuring strains at many points on a mirror, a fuel tank, an airplane wing, or other large object. Ordinarily, the effect of strain on resistance would be regarded as a nuisance in a temperature-measuring application, and the effect of temperature on resistance would be regarded as a nuisance in a strain-measuring application. The strain-induced changes in resistance of the metal film resistors in question are less than those of films in traditional strain gauges. The main novel aspect of present proposal lies in the use of circuitry affording sufficient sensitivity to measure strain plus means for compensating for the effect of temperature. For an array of metal film resistors used as proposed, the readout circuits would include a high-accuracy analog-to-digital converter fed by a low noise current source, amplifier chain, and an analog multiplexer chain. Corrections would be provided by use of high-accuracy calibration resistors and a temperature sensor. By use of such readout circuitry, it would be possible to read the resistances of as many as 100 fixed resistors in a time interval of 1 second at a resolution much greater than 16 bits. The readout data would be processed, along with temperature calibration data, to deduce the strain on the printed-circuit board or other substrate in the areas around the resistors. It should also be possible to also deduce the temperature from the readings.
An inexpensive wall clock has been devised for displaying solar time or sidereal time as it would be perceived on a planet other than the Earth, or for displaying sidereal time on the Earth. The concept of a wall clock synchronized to a period other than the terrestrial mean solar day is not new in itself. What is new here is that the clock is realized through a relatively simple electronic modification of a common battery-powered, quartz-crystal-oscillator-driven wall clock. The essence of the modification is to shut off the internal oscillator of the clock and replace the internal-oscillator output signal with a signal of the required frequency generated by an external oscillator. The unmodified clock electronic circuitry includes a quartz crystal connected to an integrated circuit (IC) that includes, among other parts, a buffer amplifier that conditions the oscillator output. The modification is effected by removing the quartz crystal and connecting the output terminal of the external oscillator, via a capacitor, to the input terminal of the buffer amplifier
An inexpensive lightweight ozone lidar telescope was designed, constructed and operated during an ozone lidar field campaign. This report summarizes the design parameters and performance of the plastic Fresnel lens telescope and shows the ozone lidar performance compared to Zemax calculations.
A comprehensive framework was explored and validated for rapid deployment and testing of custom flight control logic using the Inexpensive Multirotor Platform for Advanced Controls Testing (IMPACT). This vehicle facilitated the efficient validation and refinement of a custom flight control algorithm, which was designed using Simulink and deployed onto a Pixhawk flight computer running PX4 firmware through the utilization of the MathWorks UAV Toolbox. The robust and cost-effective design of IMPACT provides the groundwork for future flight testing of flight controls and model development research for electric vertical takeoff and landing (eVTOL) aircraft.
A wedge-shaped shock mount uses rubber for energy absorption, and the frictional characteristics of ordinary brake material for damping.
Check valve with a cylindrical flanged tube body is used in standard AN fittings. The valve also has an easily removable spring-loaded piston.
Matting cover thermally insulates cryogenic-liquid transfer pipelines. The matting consists of layers of commercially available fiber glass tape in which the fibers are randomly oriented in parallel planes.
Pressure sensor monitors small gas leaks in piping and pressure vessels. A combination of a paper ribbon and adhesive plastic tape is used to cover the area to be monitored and the pressure sensor is placed over a hole in the tape and paper.
Rocket smoke-trail wind measurement technique
Consumption multichannel pulse height analyzer performs balloon and rocket investigations of solar neutrons with energies greater than 10 MeV. The lightweight unit can operate in a temperature range of minus 30 degrees to plus 70 degrees C and withstand storage temperatures from minus 50 degrees to plus 90 degrees C.
Commercially available aluminized Mylar, cork and fiber glass form a multilayered sealed system and provide rugged and economical field installed insulation for cryogenic /liquid nitrogen or oxygen/ pipe lines in an exposed environment.
Low-cost metal tube reducer accepts tubing up to 1 inch outer diameter and can reduce this diameter to less than 1/2 inch with controlled wall thickness. This device can reduce all of the tube without waste. It produces extremely good surface finishes.