Search NASA⌕ Search

SEARCH · Search NASA

Results for “information loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Springboard Engineering's Smart Grid Controller for Non-Smart Household Electricity-Consuming Appliances (Final Technical Report)

The Smart Grid opens the door to the development of many companion technologies which will in turn enable the development of a variety of devices for household electricity-consuming appliances that can communicate with it; especially, many major appliance manufacturers (such as Whirlpool and General Electric) have made public commitments to design their appliances to be Smart Grid-compatible over the next several years. Yet during that same time period, customers will purchase many millions of long-lasting appliances which are not compatible with the Smart Grid. This research project's purpose is to bring significant Smart Grid compatibility to previously-installed appliances that were not specifically designed for any Smart Grid communications, in a way that is both economical and attractive for users who want to share in the energy cost savings and reduction of peak power demand opportunities provided by the evolving Smart Grid infrastructure. The focus of this effort is to identify and research smart control solutions which take advantage of the effective strategies of demand-response (DR) communications from utilities [including time-of-day (TOD) and peak-demand pricing options] and function apart from any need for operational changes to be designed into the non-smart appliances. Our Phase I concepts promote technological advancements for enabling devices that shift the available-use time of millions of different appliances which otherwise have no Smart Grid capability. We researched low-cost microcontroller-based ways of creating devices with the ability to: (1) maintain an accurate time and day (with no need for battery backup throughout a power outage); (2) perform two-way wired and wireless communications directly with the utility company's demand management signals, to identify both low-cost time periods as well as critical-reduction periods when the cost of energy use would otherwise be much higher; (3) measure the power usage of the connected non-smart appliance; and (4) remove power for a period of time from the appliance (such as a dehumidifier, portable heater, or pool pump) in response to both time-pricing schedule and critical peak-load information from the utility, or inform the user of a batch-type appliance (such as a clothes dryer or dishwasher) regarding the current cost associated with using the appliance. The new products that could be developed as a result of this research into new consumer-centric features and characteristics includes smart wall outlets, smart outlet power-monitoring adapters, smart load switches and smart remote electric rate indicators associated with the non-smart appliances. Our Phase I goal of determining the feasibility of the above technologies was successful. The objectives were also met of developing concepts for a family of microprocessor-based control/indicator devices that can provide the above capabilities while connected in series between an appliance and its electrical power source and/or while indicating cost-of-use status to the appliance user.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational and Experimental Mechanistic Insights into the Ethanol-to-Butanol Upgrading Reaction over MgO

The mechanism of ethanol upgrading to higher products is still under debate, especially regarding intermediate species and hydrogenation and dehydrogenation steps. In this work, we conducted a combined theoretical and experimental approach to contribute to this discussion. For such, detailed electronic structure density functional theory calculations (aiming at probing density of states, infrared spectra, geometric parameters, charge densities, and reaction energetics) and diffuse reflectance infrared Fourier transform spectroscopy experiments were carried out revealing the relevance of an appropriate combination of reactive surface sites to support the formation of several intermediates that are formed in the C-C coupling over MgO. The roles of Mg and O sites were also studied under an electronic perspective and different geometrical arrangements. We found that a kink configuration was the most adequate for ethanol to 1-butanol upgrading. Our calculations also gave us arguments to propose distinct reaction routes, whose mutual predominance would depend upon reaction temperature. At temperatures up to 573 K, the so-called β-route, which goes through scission of a Cβ-H bond and formation of an oxametallacycle-like intermediate, would dominate the coupling, whereas at higher temperatures, up to 673 K, a more usual Guerbet mechanism, via an aldol coupling step and then consecutive hydrogenations, would be expected. Here, the theoretical conclusions were followed by a careful experimental strategy using sequential experimental planning techniques in order to estimate accurate parameters with the lowest possible experimental load. Information from these different sources were coupled to develop a mathematical model for the rate of the ethanol upgrading reaction, using a Langmuir-Hinshelwood-Hougen-Watson approach. The developed and statistically validated model adequately described the experimental data at 673 K and 1.1 bar total pressure for ethanol partial pressures in the range from 0 to 20 kPa.

09 BIOMASS FUELS↗

Metaproteomics reveals enzymatic strategies deployed by anaerobic microbiomes to maintain lignocellulose deconstruction at high solids

Economically viable production of cellulosic biofuels requires operation at high solids loadings—on the order of 15 wt%. To this end we characterize Nature’s ability to deconstruct and utilize mid-season switchgrass at increasing solid loadings using an anaerobic methanogenic microbiome. This community exhibits undiminished fractional carbohydrate solubilization at loadings ranging from 30 g/L to 150 g/L. Metaproteomic interrogation reveals marked increases in the abundance of specific carbohydrate-active enzyme classes. Significant enrichment of auxiliary activity family 6 enzymes at higher solids suggests a role for Fenton chemistry. Stress-response proteins accompanying these reactions are similarly upregulated at higher solids, as are β-glucosidases, xylosidases, carbohydrate-debranching, and pectin-acting enzymes—all of which indicate that removal of deconstruction inhibitors is important for observed undiminished solubilization. Our work provides insights into the mechanisms by which natural microbiomes effectively deconstruct and utilize lignocellulose at high solids loadings, informing the future development of defined cultures for efficient bioconversion.

09 BIOMASS FUELS↗

A Distributed Energy Management Approach for Residential Demand Response

The implementation of large-scale optimization and control of residential appliances to support demand response (DR) programs comes with the challenges of coordinated communication, privacy, and consideration of customer preferences. Solving this complexity is best suited through a distributed optimization and control approach at the residential level by leveraging the availability and intelligence of a home energy management systems (HEMS). In this paper, a hierarchical control scheme to coordinate large-scale residential demand response through coordination of HEMs is proposed. This scheme is based on the exchange of a reward price and aggregated load information between utility system and HEMS. Numerical results on a one hundred-house model demonstrate the computational efficiency of the proposed approach.

Kou, Xiao↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dead-End Filtration and Crystalline Silicotitanate Cesium Ion Exchange with Hanford Tank Waste AW-102

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) directly from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW facility for immobilization. Prior to the transfer of feed to the WTP LAW facility, tank supernatant waste will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137Cs/mole of Na). This pretreatment facility will filter the waste to remove suspended solids and remove cesium from the waste stream through ion exchange. Bench-scale filtration testing of 7.4 liters of diluted of AW-102 supernate was conducted using dead-end filtration in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. A Mott 70-mm disc filter (media grade 5) was used to capture solids. The filter area was adjusted to 2.2 in2 to match the planned TSCR supernate process volume to surface area ratio. There was no indication of filter fouling and no recoverable solids were observed on the filter. Ion exchange testing with the filtered, diluted AW-102 supernatant was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Lot number 8056202-999). The column testing operations were prototypic to the intended Low-Activity Waste Pretreatment System operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~1.8 bed volumes per hour (BV/h). After 88.6 BVs of feed processing, the volume in the feed bottle dropped below the inlet tube and the lead column fluid headspace was displaced with air. Feed processing was suspended while a new column was prepared and installed into the lead position. A total of 450 BVs of diluted AW-102 feed were processed through the new lead column; only 4.3% Cs breakthrough was achieved. This volume of feed was insufficient to generate useful Cs loading information without extrapolation. A straight-line extrapolation was used to determine the 50% breakthrough of the lead column and contract limit breakthrough from the lag. The values were found to be 1200 BVs and 930 BVs, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation of Remaining Useful Lifetime Transformer Models in the Fleet-Wide Prognostic and Health Management Suite

Research and development efforts are required to address aging and reliability concerns of the existing fleet of nuclear power plants. As most plants continue to operate beyond the license life (i.e., towards 60 or 80 years), plant components are more likely to incur age-related degradation mechanisms. To assess and manage the health of aging plant assets across the nuclear industry, the Electric Power Research Institute has developed a web-based Fleet-Wide Prognostic and Health Management (FW-PHM) Suite for diagnosis and prognosis. FW-PHM is a set of web-based diagnostic and prognostic tools and databases, comprised of the Diagnostic Advisor, the Asset Fault Signature Database, the Remaining Useful Life Advisor, and the Remaining Useful Life Database, that serves as an integrated health monitoring architecture. The main focus of this paper is the implementation of prognostic models for generator step-up transformers in the FW-PHM Suite. One prognostic model discussed is based on the functional relationship between degree of polymerization, (the most commonly used metrics to assess the health of the winding insulation in a transformer) and furfural concentration in the insulating oil. The other model is based on thermal-induced degradation of the transformer insulation. By utilizing transformer loading information, established thermal models are used to estimate the hot spot temperature inside the transformer winding. Both models are implemented in the Remaining Useful Life Database of the FW-PHM Suite. The Remaining Useful Life Advisor utilizes the implemented prognostic models to estimate the remaining useful life of the paper winding insulation in the transformer based on actual oil testing and operational data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Online Model-Free Chance-Constrained Distribution System Voltage Control Using DERs: Preprint

This paper proposes an online data-driven distributed energy resource management system (DERMS) optimization method using chance-constrained formulation to address distribution system voltage regulation. This is achieved via the local sensitivity factor (LSF)-enabled reformulation of the DER control into a linear programming (LP) problem, which is easy and computationally efficient to solve. The LSF is estimated using online measurements and does not need the assumption of node load information. The latter is usually required for existing optimization-based methods but is difficult to obtain in practice. To mitigate measurement uncertainties, a scenario-based chance-constrained formulation is constructed. Compared with other control methods, the results carried out in a realistic distribution system show that the proposed method can effectively eliminate voltage violation issues.

chance-constrained optimization↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Vehicle Lateral Offset Estimation Using Infrastructure Information for Reduced Compute Load

Accurate perception of the driving environment and a highly accurate position of the vehicle are paramount to safe Autonomous Vehicle (AV) operation. AVs gather data about the environment using various sensors. For a robust perception and localization system, incoming data from multiple sensors is usually fused together using advanced computational algorithms, which historically requires a high-compute load. To reduce AV compute load and its negative effects on vehicle energy efficiency, we propose a new infrastructure information source (IIS) to provide environmental data to the AV. The new energy–efficient IIS, chip–enabled raised pavement markers are mounted along road lane lines and are able to communicate a unique identifier and their global navigation satellite system position to the AV. This new IIS is incorporated into an energy efficient sensor fusion strategy that combines its information with that from traditional sensor. IIS reduce the need for camera imaging, image processing, and LIDAR use and point cloud processing. We show that IIS, when combined with traditional sensors, results in more accurate perception and localization outcomes and a reduced AV compute load.

Sharma, Sachin↗

Short-Term Load Forecasting Considering EV Charging Loads with Prediction Interval Evaluation

Short-term load forecasting plays a critical role in power system planning and operation. Along with the electrification of various loads, electricity demands are becoming increasingly hard to predict. Notably, the recent rise in electric vehicles (EVs) has further contributed to this unpredictability. To address this issue, this paper proposes a probabilistic load forecasting strategy utilizing Gaussian process regression, structured in a day-ahead manner. While many works focus on deterministic prediction, probabilistic forecasting offers additional insights into variability and uncertainty, enabling more flexible and reliable operation for power systems. To enhance the accuracy of the load forecasting model, the inputs include features related to EV charging habits as well as commonly used weather information. The load forecasting results are evaluated using various metrics, including conventional ones that assess the accuracy of point forecasts, as well as additional metrics that test the reliability of prediction intervals. The proposed load forecasting method is finally tested on real residential power consumption data and EV charging data sampled from real-world sources. The results prove that the new features can greatly improve the performance of the load forecasting method.

electrical vehicle↗

Short-Term Load Forecasting Based Automatic Distribution Network Reconfiguration

In a traditional dynamic network reconfiguration study, the optimal topology is determined at every scheduled time point by using the real load data measured at that time. The development of the load forecasting technique can provide an accurate prediction of the load power that will happen in a future time and provide more information about load changes. With the inclusion of load forecasting, the optimal topology can be determined based on the predicted load conditions during a longer time period instead of using a snapshot of the load at the time when the reconfiguration happens; thus, the distribution system operator can use this information to better operate the system reconfiguration and achieve optimal solutions. This paper proposes a short-term load forecasting approach to automatically reconfigure distribution systems in a dynamic and pre-event manner. Specifically, a short-term and high-resolution distribution system load forecasting approach is proposed with a forecaster based on support vector regression and parallel parameters optimization. The network reconfiguration problem is solved by using the forecasted load continuously to determine the optimal network topology with the minimum amount of loss at the future time. The simulation results validate and evaluate the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Clustering of Rate-Oriented Load Metrics for Customer Price-Plan Analysis: Preprint

One of the few methods electric utilities can use to motivate and change customer energy consumption is through their retail rate structures. Utilities are increasingly moving towards more dynamic rate-plans to achieve the objectives of motivating energy conservation, increasing self-consumption from onsite renewable generation, reducing peak demand and to flattening the demand profiles. This paper presents a set of rate-oriented customer load metrics that are the determinants of customers bill under four unique rate-plans. These metrics are not only indicative of which rate structure a customer should choose based on their load profiles, but also convey useful information about load consumption behavior. With these metrics, the utility can analyze their customers and identify customer classes that are rewarded under each rate-plan. This can help inform utilities whether the customer profiles being rewarded under each rate-plans are meeting their original objectives. To develop these customer classes, we calculate these rate-oriented load metrics for each customer and perform k-means clustering. The analysis is conducted on from a set of 300 customer profiles, examining the impact of four different rate-plans, different numbers of clusters and looking at customer bills and cluster load profile characteristics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Clustering of Rate-Oriented Load Metrics for Customer Price-Plan Analysis

One of the few methods electric utilities can use to motivate and change customer energy consumption is through retail rate structures. Utilities are increasingly moving toward more dynamic rate plans to encourage energy conservation, utilization of onsite renewable generation, peak demand reduction and flattening of demand profiles. This paper creates a set of rate-oriented load metrics that are the determinants of customers' bills under four unique rate plans. These metrics are not only indicative of which rate structure can provide customer bill reductions based on their load profile characteristics, but also convey useful information about load consumption behavior. With these metrics, utilities can analyze their customers and identify classes that are rewarded under each rate plan. This can help inform utilities whether the customers rewarded under each rate plans are meeting their original objectives. To develop these customer classes, we calculate these rate-oriented load metrics for each customer and perform k-means clustering. The analysis is conducted on a set of 300 customer profiles, examining four different rate plans, different numbers of clusters, customer bills and cluster load profile characteristics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Smart Plug and Process Load Controls into Energy Management Information System Platforms: A Landscaping Study

Plug and process loads (PPLs) already represent a significant fraction of total energy use in commercial buildings and their contribution is expected to increase in the future. Although plug-in devices are typically not monitored or controlled, new wireless technologies are being developed that can provide these functions. These 'smart' outlets collect data from connected devices and transmit it to cloud services for energy measurement, tracking, and control purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cellulose–hemicellulose interactions at elevated temperatures increase cellulose recalcitrance to biological conversion

It has been previously shown that cellulose-lignin droplets’ strong interactions, resulting from lignin coalescence and redisposition on cellulose surface during thermochemical pretreatments, increase cellulose recalcitrance to biological conversion, especially at commercially viable low enzyme loadings. However, information on the impact of cellulose–hemicellulose interactions on cellulose recalcitrance following relevant pretreatment conditions are scarce. Here, to investigate the effects of plausible hemicellulose precipitation and re-association with cellulose on cellulose conversion, different pretreatments were applied to pure Avicel® PH101 cellulose alone and Avicel mixed with model hemicellulose compounds followed by enzymatic hydrolysis of resulting solids at both low and high enzyme loadings. Solids produced by pretreatment of Avicel mixed with hemicelluloses (AMH) were found to contain about 2 to 14.6% of exogenous, precipitated hemicelluloses and showed a remarkably much lower digestibility (up to 60%) than their respective controls. However, the exogenous hemicellulosic residues that associated with Avicel following high temperature pretreatments resulted in greater losses in cellulose conversion than those formed at low temperatures, suggesting that temperature plays a strong role in the strength of cellulose–hemicellulose association. Molecular dynamics simulations of hemicellulosic xylan and cellulose were found to further support this temperature effect as the xylan–cellulose interactions were found to substantially increase at elevated temperatures. Furthermore, exogenous, precipitated hemicelluloses in pretreated AMH solids resulted in a larger drop in cellulose conversion than the delignified lignocellulosic biomass containing comparably much higher natural hemicellulose amounts. In conclusion, increased cellulase loadings or supplementation of cellulase with xylanases enhanced cellulose conversion for most pretreated AMH solids; however, this approach was less effective for solids containing mannan polysaccharides, suggesting stronger association of cellulose with (hetero) mannans or lack of enzymes in the mixture required to hydrolyze such polysaccharides.

59 BASIC BIOLOGICAL SCIENCES↗

Pathways to IEC Standards for Heliostat Design Qualification and Site Acceptance in Central Receiver CSP Applications

This paper surveys the existing landscape of standards relevant to heliostats, identifies their gaps, and proposes a path forward to a comprehensive set of heliostat guidelines, technical specifications, and standards under the framework of International Electrotechnical Commission (IEC) TC 117. Gaps in existing guidelines and standards are surveyed using a three-tiered taxonomy: component-level, heliostat-level, and field-level. At each level, the gap analysis is followed by a proposal for a coordinated path forward on the development of standards. At the component level, advances in the understanding of wind loading should inform a technical specification for drives and structures. Reflectors require consolidation of measurement guidelines into existing standards documents. Communications & controls require technical standards to inform their selection and secure implementation. At the heliostat level, IEC 62817 (solar trackers) adequately characterizes drive systems, structures, and electronics, but requires adaptation to heliostats' use patterns, operating modes, and expected life cycles. IEC 62817 does not address heliostat beam quality and pointing accuracy, but the process for determining both is elaborated in the SolarPACES Guideline for Heliostat Performance Testing. This SolarPACES document requires two main modifications: adaptation to IEC language and inclusion of testing after heliostats which have undergone accelerated weathering and mechanical cycling (to understand performance degradation). At the field level, IEC 62862-4-2 addresses the function and control of heliostat fields but does not cover the statistically rigorous testing of heliostat groups, or field performance factors like security and soiling. The addition of documents under IEC-62862-4 is proposed to address this gap.

beam↗