Search NASA⌕ Search

SEARCH · Search NASA

Results for “insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

XTIP – the world's first beamline dedicated to the synchrotron X-ray scanning tunneling microscopy technique

In recent years, there have been numerous efforts worldwide to develop the synchrotron X-ray scanning tunneling microscopy (SX-STM) technique. Here, the inauguration of XTIP, the world's first beamline fully dedicated to SX-STM, is reported. The XTIP beamline is located at Sector 4 of the Advanced Photon Source at Argonne National Laboratory. It features an insertion device that can provide left- or right-circular as well as horizontal- and vertical-linear polarization. XTIP delivers monochromatic soft X-rays of between 400 and 1900 eV focused into an environmental enclosure that houses the endstation instrument. This article discusses the beamline system design and its performance.

47 OTHER INSTRUMENTATION↗

A cantilevered liquid-nitrogen-cooled silicon mirror for the Advanced Light Source Upgrade

This paper presents a novel cantilevered liquid-nitrogen-cooled silicon mirror design for the first optic in a new soft X-ray beamline that is being developed as part of the Advanced Light Source Upgrade (ALS-U) (Lawrence Berkeley National Laboratory, USA). The beamline is optimized for photon energies between 400 and 1400 eV with full polarization control. Calculations indicate that, without correction, this design will achieve a Strehl ratio greater than 0.85 for the entire energy and polarization ranges of the beamline. With a correction achieved by moving the focus 7.5 mm upstream, the minimum Strehl ratio is 0.99. This design is currently the baseline plan for all new ALS-U insertion device beamlines.

47 OTHER INSTRUMENTATION↗

Compensation of heat load deformations using adaptive optics for the ALS upgrade: a wave optics study

In this paper, a realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Harmonic suppression gratings for soft X-ray monochromators

We describe an approach to harmonic suppression in soft X-ray monochromators by engineering the reflection grating’s diffraction pattern to approximate a sinusoidal amplitude. At synchrotron and free-electron laser sources, X-ray beamlines powered by insertion devices produce a spectrum containing harmonic photon energies that can couple unwanted light into experiments. Beamlines in the soft X-ray energy range (100 eV to 2 keV) commonly employ energy-filtering elements to suppress these harmonics. Available approaches tend to be inefficient, significantly reducing the transmitted power. We show that with pseudo-grayscale binary halftone patterns, gratings can approximate a sinusoidal amplitude and suppress higher diffraction orders. Prototype demonstrations of lithographically fabricated gratings were conducted on a soft X-ray beamline with photon energies of 110 eV and 330 eV. Relative to a square-wave amplitude grating, the third-harmonic intensity was reduced by a factor of 9.0 with a first-order efficiency reduction of 38%.

Goldberg, Kenneth A. [Lawrence Berkeley National L↗

HEX 2-piece ID Absorber: Steady and Transient Thermal FEA

Radiation fans from Insertion Devices and Bending Magnets are “trimmed” by various water-cooled absorbers located strategically downstream of those sources. Mostly, the absorber surfaces onto which power is deposited are constructed from Glidcop Al-15 (rarely OFHC copper). On the basis of Tech Note 327 a re-design for improved thermal performance has evolved to a two-piece ID Absorber configuration; one between dipole chamber and quadrupole, another after the sextupole, each with reduced incident angle. The ring’s Active Interlock (AI) system protects against overheating by disabling mis-steered beam within an allotted time. SRP (Synchrotron Radiation Protection) protocol has a limiting maximum allowable temperature of 100*C at any point when subject to mis-steered beam for a fixed period before AI activation. After 0.2 msec, radiation exceeding +/- 0.5mm offset and +/- 0.25 mrad angular error from the HEX SCW will trip in fault. AI specification allows 1.0 msec to fully dump the electron beam.

36 MATERIALS SCIENCE↗

FOFB-compatible AC Local Bump as a Potential New Operations Mode for NSLS-II

AC local bumps of the beam orbit developed at NSLS-II are successfully used for accelerator physics studies. Recently, AC bumps localized at light-generating insertion devices (ID) are considered by NSLS-II beamline scientists as a possible user operation mode. The AC perturbation of the X-ray beam in a controllable way will provide a possibility to investigate the effects of the source size and temporal evolution on the coherence of the photon beam. It also can be used to average out the spatial non-uniformity of the beam intensity caused by the beamline optics. Before the implementation of the AC orbit bumps into user operations, we must investigate if the electron beam perturbation affects the other beamlines. A proof-of-principle experiment was carried out: an AC bump was created and well localized in the CSX and/or FXI beamline. Transparency of this AC bump to other beamlines has been studied, the results are discussed.

36 MATERIALS SCIENCE↗

Reducing beta functions in the NSLS-II long straight section for NEXT-III beamlines

The NSLS-II Experimental Tools III (NEXT-III) Project with the goal of building 8-12 new beamlines is ongoing. We were requested to explore the possibility of modifying the long straight section in Cell 26 to accommodate two new undulators for Advanced Nanoscale Imaging (ANI) Beamline and Tender X-ray Nanoprobe (TXN) Beamline. The scope of work includes: linear lattice matching; confirmation of the minimum ID gaps consistent with beam stay-clear limitations; calculation of the X-ray brightness; optimization of the dynamic aperture and momentum acceptance; multi-particle tracking to confirm the injection efficiency does not deteriorate significantly. The beam simulations have to be done using the most recent NSLS-II lattice model with all present insertion devices and realistic magnet errors, misalignments, and apertures. Originally two lattice options were considered for the assessment:1) with single -minimum beta functions and 2) NSLS-II with double-minimum beta functions. However, since the beamlines are not interested in the reduction of the horizontal beta function, just the vertical one, we decided to stop considering the single-minimum option because the current vertical beta is already low (3.3m) and further reducing it at the straight section center can increase it too much at the edge of a long ID, and limit the beam stay-clear. So, this report is focused on the double mini-beta scheme only.

43 PARTICLE ACCELERATORS↗

Bus repeater and bit injector for MIL-STD-1553/1760 communications bus

A fault insertion device (FID) comprises a transceiver and an FPGA. The transceiver receives signals from a MIL-STD-1553/1760 communications bus. The FPGA evaluates the signals received from the communications bus against a set of rules stored by the FPGA. Based upon the set of rules, the FPGA can selectively modify messages received from the communications bus prior to transmission to a remote terminal or a bus controller that is configured to communicate on the communications bus.

Krein, Jason P.↗

Electrochemical ion insertion from the atomic to the device scale

Electrochemical ion insertion involves coupled ion–electron transfer reactions, transport of guest species and redox of the host. The hosts are typically anisotropic solids with 2D conduction planes but can also be materials with 1D or isotropic transport pathways. These insertion compounds have traditionally been studied in the context of energy storage but also find extensive applications in electrocatalysis, optoelectronics and computing. Recent developments in operando, ultrafast and high-resolution characterization methods, as well as accurate theoretical simulation methods, have led to a renaissance in the understanding of ion-insertion compounds. In this Review, we present a unified framework for understanding insertion compounds across timescales and length scales ranging from atomic to device levels. Using graphite, transition metal dichalcogenides, layered oxides, oxyhydroxides and olivines as examples, we explore commonalities in these materials in terms of point defects, interfacial reactions and phase transformations. We illustrate similarities in the operating principles of various ion-insertion devices, ranging from batteries and electrocatalysts to electrochromics and thermal transistors, with the goal of unifying research across disciplinary boundaries.

36 MATERIALS SCIENCE↗

Perspectives on the generation of electron beams from plasma-based accelerators and their near and long term applications

This article first gives the authors' perspectives on how the field of plasma-based acceleration (PBA) developed and how the current experiments, theory, and simulations are motivated by long term applications of PBA to a future linear collider and an x-ray free electron laser. Here, we then focus on some early applications that will likely emerge from PBA research such as electron beam radiotherapy, directional but incoherent x-ray beams for science and technology, near single cycle continuously tunable infrared pulses for spectroscopy, and non-perturbative quantum electrodynamics enabled by PBA electron beams. In our opinion, these near term applications could be developed within the next decade with a concerted effort by the community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Principles and applications of x-ray light sources driven by laser wakefield acceleration

One of the most prominent applications of modern particle accelerators is the generation of radiation. In a synchrotron or an x-ray free electron laser (XFEL), high energy electrons oscillating in periodic magnetic structures emit bright x rays. In spite of their scientific appeal that will remain evident for many decades, one limitation of synchrotrons and XFELs is their typical mile-long size and their cost, which often limits access to the broader scientific community. Here, this tutorial reviews the principles and prospects of using plasmas produced by intense lasers as particle accelerators and x-ray light sources, as well as some of the applications they enable. A plasma is an ionized medium that can sustain electrical fields many orders of magnitude higher than that in conventional radio frequency accelerator structures and can be used to accelerate electrons. When short, intense laser pulses are focused into a gas, it produces electron plasma waves in which electrons can be trapped and accelerated to GeV energies. This process, laser-wakefield acceleration (LWFA), is analogous to a surfer being propelled by an ocean wave. Many radiation sources, from THz to gamma-rays, can be produced by these relativistic electrons. This tutorial reviews several LWFA-driven sources in the keV-MeV photon energy range: betatron radiation, inverse Compton scattering, bremsstrahlung radiation, and undulator/XFEL radiation. X rays from laser plasma accelerators have many emerging applications. They can be used in innovative and flexible x-ray imaging and x-ray absorption spectroscopy configurations, for use in biology, industry, and high-energy density science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Overlap junctions for superconducting quantum electronics and amplifiers

Due to their unique properties as lossless, nonlinear circuit elements, Josephson junctions lie at the heart of superconducting quantum information processing. Previously, we demonstrated a two-layer, submicrometer-scale overlap junction fabrication process suitable for qubits with long coherence times. Here, we extend the overlap junction fabrication process to micrometer-scale junctions. This allows us to fabricate other superconducting quantum devices. For example, we demonstrate an overlap junction-based Josephson parametric amplifier that uses only two layers. This efficient fabrication process yields frequency-tunable devices with negligible insertion loss, a gain of ∼30 dB, and quantum limited noise performance. Compared to other processes, the overlap junction allows for fabrication with minimal infrastructure, high yield, and state-of-the-art device performance.

Bal, Mustafa (ORCID:0000000307516774)↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local control robotic surgical devices and related methods

The various robotic medical devices include robotic devices that are disposed within a body cavity and positioned using a support component disposed through an orifice or opening in the body cavity. Additional embodiments relate to devices having arms coupled to a device body wherein the device has a minimal profile such that the device can be easily inserted through smaller incisions in comparison to other devices without such a small profile. Further embodiments relate to methods of operating the above devices.

Markvicka, Eric↗

Probing local electrochemistry via mechanical cyclic voltammetry curves

Understanding the mechanical response of an electrode during electrochemical cycling and its correlation to the device electrochemical performance is crucial to improving the performance of insertion-type energy storage devices, electrochemical actuators, water purification, ion separation and neuromorphic computing applications. Here, we visualized the electro-chemo-mechanical coupling behaviors during charge storage of anhydrous and hydrated WO 3 electrodes via in situ atomic force microscopy (AFM) and developed the concept of mechanical cyclic voltammetry (mCV) curves. The relationship between electrochemical current and strain was investigated with simplified models and the results revealed that the proton insertion/deinsertion process could be described through potential-dependent electro-chemo-mechanical coupling coefficients which might indicate changes in insertion processes during electrode cycling. The mCV mapping results highlight the local heterogeneity and show that the charging processes varied across the electrode. These local variations could be further correlated to local morphology, crystal orientations or chemical compositions with proper electrode designs.

36 MATERIALS SCIENCE↗

SYSM-562: DIM Fiber Connection Improvement Analysis

The National Ignition Facility is equipped with a wide suite of diagnostics including optical, x-ray, and neutron diagnostics to analyze experiments and look for areas of improvements. NIF diagnostics are either deployed to a fixed location on the target chamber or on a Diagnostic Instrument Manipulator (DIM). DIMs are two-stage telescoping devices used to insert, retract, position, and align a diagnostic instrument in the target chamber. Additionally, DIMs provide a standard set of cables to support operation of all DIM-based diagnostic instruments.

42 ENGINEERING↗