Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Overview of NASA Earth Observing Systems Terra and Aqua Moderate Resolution Imaging Spectroradiometer Instrument Calibration Algorithms and On-Orbit Performance

Since launch, the Terra and Aqua moderate resolution imaging spectroradiometer (MODIS) instruments have successfully operated on-orbit for more than 9 and 6.5 years, respectively. Iv1ODIS, a key instrument for the NASA's Earth Observing System (EOS) missions, was designed to make continuous observations for studies of Earth's land, ocean, and atmospheric properties and to extend existing data records from heritage earth-observing sensors. In addition to frequent global coverage, MODIS observations are made in 36 spectral bands, covering both solar reflective and thermal emissive spectral regions. Nearly 40 data products are routinely generated from MODIS' observations and publicly distributed for a broad range of applications. Both instruments have produced an unprecedented amount of data in support of the science community. As a general reference for understanding sensor operation and calibration, and thus science data quality, we ;provide an overview of the MODIS instruments and their pre-launch calibration and characterization, and describe their on-orbit calibration algorithms and performance. On-orbit results from both Terra and Aqua MODIS radiometric, spectral, and "spatial calibration are discussed. Currently, both instruments, including their on-board calibration devices, are healthy and are expected to continue operation for several }rears to come.

Xiong, Xiaoxiong↗

Uncertainty Analysis of Instrument Calibration and Application

Experimental aerodynamic researchers require estimated precision and bias uncertainties of measured physical quantities, typically at 95 percent confidence levels. Uncertainties of final computed aerodynamic parameters are obtained by propagation of individual measurement uncertainties through the defining functional expressions. In this paper, rigorous mathematical techniques are extended to determine precision and bias uncertainties of any instrument-sensor system. Through this analysis, instrument uncertainties determined through calibration are now expressed as functions of the corresponding measurement for linear and nonlinear univariate and multivariate processes. Treatment of correlated measurement precision error is developed. During laboratory calibration, calibration standard uncertainties are assumed to be an order of magnitude less than those of the instrument being calibrated. Often calibration standards do not satisfy this assumption. This paper applies rigorous statistical methods for inclusion of calibration standard uncertainty and covariance due to the order of their application. The effects of mathematical modeling error on calibration bias uncertainty are quantified. The effects of experimental design on uncertainty are analyzed. The importance of replication is emphasized, techniques for estimation of both bias and precision uncertainties using replication are developed. Statistical tests for stationarity of calibration parameters over time are obtained.

Tripp, John S.↗

Prelaunch Instrument Calibration in the Real World: The GOES Example

The pre-launch ground infrared calibration of the Geostationary Operational Environmental Satellite (GOES) N-Q Imager and Sounder is presented. Ground calibration provides information necessary to the accurate on-orbit calibration of these radiometers. Infrared channels are calibrated in a thermal vacuum environment, under minimum and maximum mission operation temperatures, using a variable-temperature warm target to simulate the Earth scene and a cold target to simulate the space scene. Brightness temperatures derived from observation of the instrument internal calibration target, used for on-orbit calibration, are compared to brightness temperatures of the external calibration target as a check of relative accuracy using these two sources. Changes to the GOES N-Q specification from GOES I-M are highlighted, as well as results of noise, relative calibration accuracy, and spectral response performance to date. For completeness, results of spatial and pointing performance will be presented. Enhancements to test methodology and data processing techniques are highlighted throughout.

Murphy-Morris, J.↗

Multipurpose Spectroradiometer for Satellite Instrument Calibration and Zenith Sky Remote Sensing Measurements

In the early 1990s a series of surface-based direct sun and zenith sky measurements of total column ozone were made with SBUV/2 flight models and the SSBUV Space Shuttle instrument in Boulder, Colorado which were compared with NOAA Dobson Instrument direct sun observations and TOMS instrument overpass observations of column ozone. These early measurements led to the investigation of the accuracy of derived total column ozone amounts and aerosol optical depths from zenith sky observations. Following the development and availability of radiometrically stable IAD narrow band interference filter and nitrided silicon photodiodes a simple compact multifilter spectroradiometer was developed which can be used as a calibration transfer standard spectroradiometer (CTSS) or as a surface based instrument remote sensing instruments for measurements of total column ozone and aerosol optical depths. The total column ozone derived from zenith sky observations agrees with Dobson direct sun AD double wavelength pair measurements and with TOMS overpass ozone amounts within uncertainties of about 1%. When used as a calibration transfer standard spectroradiometer the multifilter spectroradiometer appears to be capable of establishing instrument radiometric calibration uncertainties of the order of 1% or less relative to national standards laboratory radiometric standards.

Heath, Donald F.↗

Specifying and calibrating instrumentations for wideband electronic power measurements

The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.

Lesco, D. J.↗

Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration

The most accurate astronomical data is available from space-based observations that are not impeded by the Earth's atmosphere. Such measurements may require spectral samples taken as long as decades apart, with the 1 cm/s velocity precision integrated over a broad wavelength range. This raises the requirements specifically for instruments used in astrophysics research missions -- their stringent wavelength resolution and accuracy must be maintained over years and possibly decades. Therefore, a stable and broadband optical calibration technique compatible with spaceflights becomes essential. The space-based spectroscopic instruments need to be calibrated in situ, which puts forth specific requirements to the calibration sources, mainly concerned with their mass, power consumption, and reliability. A high-precision, high-resolution reference wavelength comb source for astronomical and astrophysics spectroscopic observations has been developed that is deployable in space. The optical comb will be used for wavelength calibrations of spectrographs and will enable Doppler measurements to better than 10 cm/s precision, one hundred times better than the current state-of-the- art.

Strekalov, Dmitry V.↗

The Harvard experiment on OSO-6 - Instrumentation, calibration, operation, and description of observations.

The Harvard experiment carried by OSO-6 was an extreme-ultraviolet (EUV) spectrometer-spectroheliometer with a wavelength range of 285 to 1385 A, a spatial and spectral bandwidth of 35 x 35(arc sec) squared and 3 A, respectively. The instrument acquired data that have been deposited with the National Space Science Data Center and World Data Center A at the Goddard Space Flight Center in Greenbelt, Maryland, and are now available in their entirety to the scientific community. Aspects of the experiment that are relevant to potential users of the data are described - namely, instrument configuration and parameters, laboratory and inflight calibrations, as well as operational capabilities and procedures. The observations obtained are reported, and the nature, number, and dates of observation, where relevant, are listed.

Huber, M. C. E.↗

Instrument calibrates low gas-rate flowmeters

Electronically measuring the transit time of a soap bubble carried by the gas stream between two fixed points in a burette calibrates flowmeters used for measuring low gas-flow rates.

Copeland, A. C.↗

Report on the Workshop on Intercomparison of Solar UV Irradiance Measurements and Related Instrument Calibration

The knowledge of the absolute value of the solar ultraviolet irradiance did not improve very much during the rising phase of the solar cycle 21. The variations associated with the solar rotation period were observed by means of three satellites, namely, the Atmospheric Explorer E (AE-E), Nimbus 7 and the Solar Mesospheric Explorer (SME). Long-term variations related to the solar activity cycle are not well known. Values were deduced during the solar cycle 21 from the AE-E satellite and the rocket program performed by the Laboratory for Atmospheric and Space Physics leading to variations of about a factor of 2 around 150 nm but definitely less than 20 percent beyond 175 nm. Such low level of variation is still masked by the current uncertainties and reproducibility of the observations performed since 1976. The uncertainties of recent observations are reported with their discrepancies. The gaps between the current accuracy goals and the achievements are still very important. The challenge for the next three years is to improve both the accuracy and the precision of future observations at the level of the available irradiance standards and to measure quantitatively long-term variations of the order of a few percent. The main causes of these gaps are identified.

Simon, P. C.↗

TSF Instrumentation Calibration Plan

This document describes the process by which the Thermo-Physics Facilities Branch, Code TSF, implements APR 8730.1, "Metrology/Calibration" and defines the responsibilities and requirements for periodic calibration of IM&TE used in branch facilities for data product and safety-critical measurements.

Scott Eddlemon↗