Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigations into the Ternary NaF-KF-UF4 Salt System – Phase A

A knowledge gap exists in the data and understanding of fresh fuel salt and irradiated multicomponent fuel salt systems thermophysical properties. Quantifying these properties is necessary for the design and construction of test reactors, as well as the licensing of future commercial molten-salt reactors. To facilitate thermal property determination on a proposed fuel salt composition for Seaborg Technologies, several samples containing depleted uranium tetrafluoride (UF4), sodium fluoride (NaF), and potassium fluoride (KF) were blended, and a melt temperature analysis was performed. From the melting temperature analysis, it was determined that sample Seaborg-7, a ternary salt composition of 26.4UF4-24.7KF-48.9NaF (mol%), was very near a ternary eutectic point. Therefore, thermal properties such as melting temperature, salt stability, density, heat capacity, thermal diffusivity, and viscosity were experimentally determined on the Seaborg-7 salt. These measurements document the baseline properties of fresh fuel salt as a function of temperature, where future experiments on irradiated fuel salt will provide a holistic perspective on the change of thermophysical properties during reactor operations. Several precision instruments were used to collect property data, and instrument calibrations and data collection were performed and documented in a standardized and reproducible manner with meticulous detail. This process ensured that the measurement procedures and resulting data can readily be duplicated elsewhere. The Seaborg-7 salt was shown to be stable at temperatures up to 900°C, as no mass change was observed upon repeated heating and cooling. The peak melting temperature was determined to be 547°C (557°C endset). The enthalpy of fusion (??H?_fus^o) was determined to be 167.5 ± 2.7 J/g while the enthalpy of crystallization (??H?_c^o) was determined to be -147.8 ± 13.3 J/g. In addition to the eutectic melting peak, upon heating, several pre eutectic peaks were observed, occurring at 470°C (onset) and 499°C (peak). Specific heat capacity measurements showed a slightly increasing trend with respect to temperature in the solid phase, while the liquid-specific heat capacity showed a somewhat flat trend with an average value of 106.1 ± 1.24 J/mol·K between 600 to 800°C. Three independent trials using the Seaborg-7 salt determined the density to be ?(T) = 4.908 – 0.000363·T(°C), validated between 32 to 200°C, and ?(T) = 4.808 – 0.00113·T(°C), validated between ~575 to 850°C. Thermal diffusivity was determined for the liquid state and is represented by the linear equation y = 0.1581 + 0.000207·T(°C) between 550 to 850°C. The viscosity was determined from 600 to 800°C and is represented by the exponential fit equation, ? (mPa·s) = 736.58e^(-0.006·T(°C)). This report documents the conclusion of fuel salt thermophysical property measurements for the Seaborg SPP, Phase A project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Position-Dependent Neutron Time-of-Flight Deviation at VULCAN Diffractometer

In neutron diffraction, it is critical to precisely measure the lattice spacing, as it is an indicator of a material’s physical characteristics, such as lattice strain, thermal expansion, and phase structures. In time-of-flight (TOF) measurements, the lattice spacing is determined by the recorded TOF from a well-calibrated instrument. However, changes in neutron time-of-flight are sensitive to many factors, such as the alignment of instrument optics, temperature, sample positions, sample dimensions, internal strains, and chemical or physical heterogeneities at the grain level. At VULCAN (SNS, ORNL), which is a high-flux engineering neutron diffractometer, we used a 1-mm-diameter diamond powder sample to scan for changes in TOF by measuring d-spacing values at different sample positions under several configurations. The 2D map of the TOF deviation or d-spacing deviation, in terms of lattice shift/lattice strain, is reported. The change in TOF is dependent on the scanned location in the beam as well as on detector locations. The results are informative for experimental planning, data interpretation, and future instrument design.

36 MATERIALS SCIENCE↗

DrEVL Radiometer Calibration

This report details the calibration procedures that were used for the spectral and radiometric part of the DrEVL radiometers. Our goal was to develop a highly repeatable and low cost spectral radiometer that could be deployed at numerous sites to collect a catalog of lightning data. Maximizing the re-usability of that data requires a well-calibrated instrument.

47 OTHER INSTRUMENTATION↗

A NICER View of the Massive Pulsar PSR J0740+6620 Informed by Radio Timing and XMM-Newton Spectroscopy

We report on Bayesian estimation of the radius, mass, and hot surface regions of the massive millisecond pulsar PSR J0740+6620, conditional on pulse-profile modeling of Neutron Star Interior Composition Explorer X-ray Timing Instrument event data. We condition on informative pulsar mass, distance, and orbital inclination priors derived from the joint North American Nanohertz Observatory for Gravitational Waves and Canadian Hydrogen Intensity Mapping Experiment/Pulsar wideband radio timing measurements of Fonseca et al. We use XMM-Newton European Photon Imaging Camera spectroscopic event data to inform our X-ray likelihood function. The prior support of the pulsar radius is truncated at 16 km to ensure coverage of current dense matter models. We assume conservative priors on instrument calibration uncertainty. We constrain the equatorial radius and mass of PSR J0740+6620 to be ${12.39}_{-0.98}^{+1.30}$ km and ${2.072}_{-0.066}^{+0.067}$ M ⊙ respectively, each reported as the posterior credible interval bounded by the 16% and 84% quantiles, conditional on surface hot regions that are non-overlapping spherical caps of fully ionized hydrogen atmosphere with uniform effective temperature; a posteriori, the temperature is ${\mathrm{log}}_{10}(T\,[{\rm{K}}])={5.99}_{-0.06}^{+0.05}$ for each hot region. All software for the X-ray modeling framework is open-source and all data, model, and sample information is publicly available, including analysis notebooks and model modules in the Python language. Furthermore, our marginal likelihood function of mass and equatorial radius is proportional to the marginal joint posterior density of those parameters (within the prior support) and can thus be computed from the posterior samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Trace gases at TRACER ANC site

Speciated volatile organic compounds (VOCs) were measured using an Ionicon PTR-TOF 8000 from 20 June to 3 July 2022 at the TRACER ancillary (TRACER ANC) site in Guy, TX. The dataset is reported at 1-min time resolution. Mixing ratios (ppb) are provided for acetone, methanol, acetaldehyde, dimethyl sulfide (DMS), furan, isoprene, methyl vinyl ketone plus methyl ethyl ketone (MVK + MEK), terpenes, xylene, and trimethylbenzene. Instrument calibrations for these species were performed weekly using a certified gas standard.

acetaldehyde↗

NGEE Arctic CO2, CH4 and Energy Eddy-Covariance (EC) Flux Tower Auxiliary Measurements, Utqiagvik (Barrow), Alaska, 2012 - 2019

Measurements began in September 2012 and are generally made throughout the snow-free growing season starting from April (pre-thawing) until November (freeze-up) when the instrumentation is taken down for maintenance and instrument calibration. CO2, CH4 and energy fluxes using the Eddy Covariance (EC) technique (Baldocchi 2003) and meteorological measurements are reported as 30-minute averages. The tower site is registered with AmeriFlux as US-NGB. See http://ameriflux.lbl.gov/sites/siteinfo/US-NGB for more information. Reported data include: (1) additional/extra meteorological and eddy covariance CO2, CH4 and energy flux data, (2) binned spectra for the three wind components, the sonic temperature and gas densities together with the binned cospectra for covariances of w (vertical wind component) and gas densities, (3) binned ogives (cumulative (co)spectra) for the three wind components, the sonic temperature and gas densities, and (4) tower site footprint matrices. Meteorological and eddy covariance CO2, CH4 and energy flux data (AmeriFlux BASE data product) are available from AmeriFlux https://doi.org/10.17190/AMF/1436326. The tower site is adjacent to the NGEE Arctic Tram system with several complementary time-series measurements https://doi.org/10.5440/1558782.This dataset supersedes the previously released dataset "Eddy-Covariance and auxiliary measurements, NGEE-Barrow, 2012-2013" DOI:10.5440/1124200 as this new product includes data for the longer time period processed using consistent methods for the entire record. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) near Utqiagvik (Barrow), Alaska and 2) multiple areas in the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Production of Xenon-135 from isotopically enriched Xenon-134 and Xenon-136 Targets

Atmospheric radioxenon analyses conducted under the Comprehensive Test Ban Treaty Organization (CTBTO) necessitates the collection and analysis of air samples to quantify 135Xe, an indicator for nuclear explosions and reactor operations. Analytical instrument calibration for these analyses requires high quality, monoisotopic reference standards that are typically short lived, and therefore must be produced and shipped promptly to monitoring stations worldwide. This work describes the preparation of 135Xe by neutron capture (n, ?) on monoisotopic 134Xe, neutron irradiation (n,2n) on monoisotopic 136Xe, and high energy photon irradiation (?, n) on monoisotopic 136Xe. The targets are prepared by electromagnetic isotope separation of natural xenon. Results from each process are compared for 135Xe yield and purity.

07 ISOTOPE AND RADIATION SOURCES↗

Photonuclear Production of Radioxenon for Air Samples

Radioxenon plays an important role in ensuring compliance with the Comprehensive Nuclear-Test-Ban Treaty due to its ability to be transported through the atmosphere, as well as the fact that the half-lives of its isotopes provide a window long enough to be detected but not long enough that it could become background radiation. This allows it to be correlated with specific events that indicate the testing of nuclear weapons. Idaho National Laboratory supports this mission by providing spiked air samples for monitoring stations to enable instrument calibration and ensure measurement accuracy. We tested a photonuclear method of producing one of the main isotopes of radioxenon, Xe-135. We also tested the separation of Xe-135 from the parent isotope Xe-136 using the method of kinematic recoil. Aluminum coils were placed in quartz ampoules filled with enriched Xe-136 and were irradiated by a bremsstrahlung beam with an endpoint energy of 21 MeV. The results showed that we were not only successful in producing Xe-135 but also that the Xe-135 was deposited into the coil allowing it to be removed from the Xe-136 gas. The coil and the Xe-135 can then be chemically separated. At the time of counting the coil, it was calculated that there was about 18 Bq of activity from Xe-135 remaining in the coil. Future work includes determining the optimal material and geometry of the catcher to maximize the amount of Xe-135 captured.

07 ISOTOPE AND RADIATION SOURCES↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Experimental methods for laboratory measurements of helium spectral line broadening in white dwarf photospheres

White Dwarf (WD) stars are the most common stellar remnant in the universe. WDs usually have a hydrogen or helium atmosphere, and helium WD (called DB) spectra can be used to solve outstanding problems in stellar and galactic evolution. DB origins, which are still a mystery, must be known to solve these problems. DB masses are crucial for discriminating between different proposed DB evolutionary hypotheses. Current DB mass determination methods deliver conflicting results. The spectroscopic mass determination method relies on line broadening models that have not been validated at DB atmosphere conditions. We performed helium benchmark experiments using the White Dwarf Photosphere Experiment (WDPE) platform at Sandia National Laboratories' Z-machine that aims to study He line broadening at DB conditions. Using hydrogen/helium mixture plasmas allows investigating the importance of He Stark and van der Waals broadening simultaneously. Accurate experimental data reduction methods are essential to test these line-broadening theories. In this paper, we present data calibration methods for these benchmark He line shape experiments. We give a detailed account of data processing, spectral power calibrations, and instrument broadening measurements. Uncertainties for each data calibration step are also derived. We demonstrate that our experiments meet all benchmark experiment accuracy requirements: WDPE wavelength uncertainties are <1 Å, spectral powers can be determined to within 15%, densities are accurate at the 20% level, and instrumental broadening can be measured with 20% accuracy. Fulfilling these stringent requirements enables WDPE experimental data to provide physically meaningful conclusions about line broadening at DB conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a hybrid neural network and transfer learning model for optimized ICP-MS/MS operation

Correct function and calibration of instrumentation is a crucial assumption for any scientific experiment. One such instrument, tandem inductively coupled plasma mass spectrometer (ICP-MS/MS), has in-depth calibration settings that range across 30+ different parameters, making it difficult to determine optimal conditions without expertise and some degree of trial and error. Often, these settings are hand-tuned, a time-intensive process prone to local maxima and human error. While some automation is available, the automation also may favor local optimizations over a global optimum. In addition to these difficulties, day to day instrument variability can further complicate the calibration process. We propose a solution to this problem as a machine learning (ML) algorithm that learns how each parameter helps determine the calibration sensitivity across several elements, and re-weights parameters over time as instrument variability changes (e.g., a global neural network (NN) with a time-dependent transfer learning (TL) component). This model would be able to generate a surface of predicted calibration sensitivities and their respective parameters, and a simple multivariate algorithm would be able to pull out the optimum results with the settings associated with them. Here-in, we describe our initial findings in working towards this goal, including data extraction from historical files, exploratory data analysis, and some initial model building to better describe the data and the feasibility of our goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

drtsans

drtsans is highly modular, allowing users to customize collected data as well as test hypothetical or simulated neutron events data. Instrument scientists can use the advance features of drtsans to calibrate their instruments and reduced large quantities of datasets in a streamlined mode. Users can correct the collected data with dark current subtraction and normalization by neutron flux, detector sensitivity, solid angle subtended by the detectors, and scaling to absolute units. Conversion from time-of-flight and/or wavelength to 1D or 2D momentum transfer renders the final scattering quantities amenable to analysis.

Bilheux, JeanC↗

NREL Pyrheliometer Comparisons: September 23 - September 28, 2023 (NPC-2023)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, for improving our understanding of Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ACR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an quinquennial International Pyrheliometer Comparison (IPC) event for transferring the WRR to participating radiometers by invitation. The National Renewable Energy Laboratory (NREL) has represented the U.S. Department of Energy (DOE) in each IPC since 1980. And NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and it uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025-accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR.

14 SOLAR ENERGY↗

Characterization of the pressure coefficient of manganin and temperature evolution of pressure in piston-cylinder cells

Here, we report measurements of the temperature- and pressure-dependent resistance, R ( T , p ), of a manganin manometer in a 4 He-gas pressure setup from room temperature down to the solidification temperature of 4 He ( T solid ~ 50 K at 0.8 GPa) for pressures, p , between 0 GPa and ~0.8 GPa. The same manganin wire manometer was also measured in a piston-cylinder cell (PCC) from 300 K down to 1.8 K and for pressures between 0 GPa and ~2 GPa. From these data, we infer the temperature and pressure dependence of the pressure coefficient of manganin, α ( T , p ), defined by the equation R p = (1 + αp ) R 0 , where R 0 and R p are the resistances of manganin at ambient pressure and finite pressure, respectively. Our results indicate that upon cooling, α first decreases, then goes through a broad minimum at ~120 K, and increases again toward lower temperatures. In addition, we find that α is almost pressure-independent at T ≳ 60 K up to p ~ 2 GPa, but shows a pronounced p dependence at T ≲ 60 K. Using this manganin manometer, we demonstrate that p overall decreases with decreasing temperature in the PCC for the full pressure range and that the size of the pressure difference between room temperature and low temperatures ( T = 1.8 K), Δ p , decreases with increasing pressure. We also compare the pressure values inferred from the manganin manometer with the low-temperature pressure, determined from the superconducting transition temperature of elemental lead (Pb). As a result of these data and analysis, we propose a practical algorithm to infer the evolution of pressure with temperature in a PCC.

47 OTHER INSTRUMENTATION↗