Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrumentation for neutron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

TORONE: Total Characterisation by Remote Observation of Nuclear Environments - 20591

This paper describes the autonomous robotic systems developed in the TORONE project (Total Characterisation by Remote Observation of Nuclear Environments) for combined characterisation by remote techniques in nuclear environments. There are four main components to the system. Firstly, robot operation which uses a Robot Operating System (ROS) allowing ease of communication between hardware and software alongside robot vision systems such as Lidar and/or photogrammetry. Secondly, radiation detection instrumentation for gamma and neutron sources which is also collimated for spatial resolution. Thirdly, photonic characterisation instrumentation for remote material identification by means of Raman spectroscopy and Laser induced breakdown spectroscopy (LIBS). Finally, a data management system is described which contains the TORONE characterisation data with the ability to overlay material characterisation information onto 3D maps of the nuclear environment. Preliminary results are described alongside discussion of some of the synergies of the combined approach. There are many applications of such an autonomous system in nuclear decommissioning, waste management and asset management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enabling Autonomous Electron Microscopy for Networked Computation and Steering

Advanced electron microscopy workflows require an ecosystem of microscope instruments and computing systems possibly located at different sites to conduct remotely steered and automated experiments. Current workflow executions involve manual operations for steering and measurement tasks, which are typically performed from control workstations co-located with microscopes; consequently, their operational tempo and effectiveness are limited. We propose an approach based on separate data and control channels for such an ecosystem of Scanning Transmission Electron Microscopes (STEM) and computing systems, for which no general solutions presently exist, unlike the neutron and light source instruments. We demonstrate automated measurement transfers and remote steering of Nion STEM physical instruments over site networks. We propose a Virtual Infrastructure Twin (VIT) of this ecosystem, which is used to develop and test our steering software modules without requiring access to the physical instrument infrastructure. Additionally, we develop a VIT for a multiple laboratory scenario, which illustrates the applicability of this approach to ecosystems connected over wide-area networks, for the development and testing of software modules and their later field deployment.

Al Najjar, Anees↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Building Neutron Scattering Infrastructure in Louisiana for Advanced Materials (Final Report)

The main objective of the Louisiana Consortium for Neutron Scattering (LaCNS) is to build a major neutron scattering infrastructure capable of treating both soft and hard materials. The goal is to create a sustainable effort having the quality, breadth, and depth necessary to produce competitive proposals including collaborative and center type proposals. Our scientific aim is to understand the role of coupling in emergent complex materials and its impact on the structure/property relationship and to explore how to tune the key couplings to guide the design of materials with the desired properties. This naturally includes building a base of users of the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) in Louisiana; to train highly talented graduate and post-doctoral students in synthesis, neutron scattering, and simulation and modeling techniques, thereby helping to produce the next generation of scientist who use neutron scattering techniques as a crucial part of their research. The goal of our hard matter program is to understand the interplay between spin, charge, orbital, and lattice degrees of freedom in carefully selected complex materials. We have made considerable progress on number of complex systems including the oxide Sr3(Ru1-xMnx)2O7 where short-range magnetic ordering with anisotropic spin texture is initiated at the metal-insulator transition that clearly indicates a strong spin-charge coupling. Another critical area is in quantum materials. For example, in the topological semimetal BaMnSb2, we found a 3D canted antiferromagnetic Weyl semimetal with a 2D electronic structure and a nontrivial Berry phase. In addition, in the hexagonal chiral Mn1/3NbS2 system, we found soliton/soliton and soliton/antisoliton domain walls where the application of small fields or small currents can be used to control nanoscopic magnetic domains where the control of domain walls is crucially important for information storage. In addition, chemical transformation investigations were performed on the VISION instrument at Spallation Neutron Source (SNS). The soft matter effort was focused on understanding the role of non-covalent interactions on the structure and dynamics of fluid-based soft matter. One key focus was on sequence-defined (SD) amphiphilic peptoid polymers that allow encoding of molecular interactions and thereby systematic investigations of how charge directs the solution self-assembly of amphiphilic polymers in water. Another important area was on the dynamics of lipids self-assembled into membranes for exploring the permeability and mechanical using both neutron spin echo (NSE) spectroscopy and quasielastic neutron scattering (QENS) to distinguished between viscoelasticity and permeability at the molecular scale. Overall, the LaCNS project was quite successful, generating 145 publications and 245 presentations. Our graduate and post-doctoral students were well trained resulting in positions in national laboratories (Oak Ridge National Laboratory (ORNL), Argonne National Laboratory and Los Alamos National Laboratory), major research universities, and industry. We also developed a uniaxial pressure cell along with ORNL for SNS. A critical goal of this project was to establish a foundation for competing nationally in federally funded research programs. To this end, we were quite successful in generating over twenty-two federally and non-federally funded grants including awards from NSF, DOE, and DOD, and two early career awards. Equally important, we were able to secure a key major piece of instrumentation via a large ARO grant for a state-of-the-art electron microscope.

36 MATERIALS SCIENCE↗

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

The HIBEAM instrument at the European spallation source

The European spallation source (ESS) will be the world’s brightest neutron source and will open a new intensity frontier in particle physics. The HIBEAM collaboration aims to exploit the unique potential of the ESS with a dedicated ESS instrument for particle physics which offers world-leading capability in a number of areas. The HIBEAM program includes the first search in thirty years for free neutrons converting to antineutrons and searches for sterile neutrons, ultralight axion dark matter and nonzero neutron electric charge. This paper outlines the capabilities, design, infrastructure, and scientific potential of the HIBEAM program, including its dedicated beamline, neutron optical system, magnetic shielding and control, and detectors for neutrons and antineutrons. Additionally, we discuss the long-term scientific exploitation of HIBEAM, which may include measurements of the neutron electric dipole moment and precision studies of neutron decays.

47 OTHER INSTRUMENTATION↗

A science-driven approach to optimize the design for a biological small-angle neutron scattering instrument

Biological small-angle neutron scattering (SANS) instruments facilitate critical analysis of the structure and dynamics of complex biological systems. However, with the growth of experimental demands and the advances in optical systems design, a new neutron optical concept is necessary to overcome the limitations of current instruments. This work presents an approach to include experimental objectives ( i.e. the science to be supported by a specific neutron scattering instrument) in the optimization of the neutron optical concept. The approach for a proposed SANS instrument at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory, USA, is presented here. Further, the instrument is simulated with the McStas software package. The optimization process is driven by an evolutionary algorithm using McStas output data, which are processed to calculate an objective function designed to quantify the expected performance of the simulated neutron optical configuration for the intended purpose. Each McStas simulation covers the complete instrument, from source to detector, including realistic sample scattering functions. This approach effectively navigates a high-dimensional parameter space that is otherwise intractable; it allows the design of next-generation SANS instruments to address specific scientific cases and has the potential to increase instrument performance compared with traditional design approaches.

47 OTHER INSTRUMENTATION↗

ESAC (EQ-SANS Assisting Chatbot): Application of large language models and retrieval-augmented generation for enhanced user experience at EQ-SANS

Neutron scattering experiments have played vital roles in exploring materials properties in the past decades. While user interfaces have been improved over time, neutron scattering experiments still require specific knowledge or training by an expert due to the complexity of such advanced instrumentation and the limited number of experiments each person may perform each year. This paper introduces an innovative chatbot application that leverages Large Language Models(LLM) and Retrieval-Augmented Generation (RAG) technologies to significantly enhance the user experience at the EQ-SANS, a small-angle neutron scattering instrument at the Spallation Neutron Source of Oak Ridge National Laboratory. Through a user-centric design approach, the EQ-SANS Assisting Chatbot (ESAC) serves as an interactive reference for users, thereby facilitating the use of the instrument by visiting scientists. By bridging the gap between the users of EQ-SANS and the control systems required to perform their experiments, the ESAC sets a new standard for interactive learning and support for the scientific community using large-scale scientific facilities.

97 MATHEMATICS AND COMPUTING↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

Advanced Modeling and Simulation Methods for Evaluation of Thermal Neutron Scattering Materials

With the rise of interest in thermal neutron scattering data for advanced reactor, criticality safety, and shielding applications, new experimental data are required for evaluation of new materials or for re-evaluation (or validations) of previously evaluated materials. New experimental data are evaluated in a three-step process: (1) computing the phonon characteristics, (2) computing the dynamic structure factor (DSF) from the data, and (3) using the experimental setup to simulate the experimental data. All three steps have challenges, ranging from the need for a sufficiently general material simulation code—a processing code that can compute the corresponding DSF—to having a detailed layout of the instrument/beamline/facility where the data were measured. Whereas phonon characteristics of materials can be computed using various methods (molecular dynamics, density functional theory, etc.), a high-fidelity computation of the DSF and the simulation of the experiment based on the DSF is vital to the accuracy of the evaluation. The latter two steps can be achieved by using the two corresponding code systems developed by instrument scientists at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory: (1) OCLIMAX, a program that calculates the dynamic structure factor from DFT and MD simulation results, and (2) MCViNE, a Monte Carlo neutron ray-tracing program designed to simulate neutron scattering experiments. Recently, polyethylene and yttrium hydride were measured at the Wide Angular-Range Chopper (ARCS) and SEQUOIA instrument stations of the SNS. These experiments are simulated using the density functional theory code, the Cambridge Serial Total Energy Package (CASTEP), to compute its phonon characteristics (eigenvalues/vectors and PDOS), which is then processed using OCLIMAX to yield the DSF, and finally the data at each instrument station are simulated by the MCViNE for comparison to the measured data for evaluation. For comparison to conventional evaluation methods, the scattering data processed from OCLIMAX are compared against those processed from the LEAPR module of NJOY, and the results from MCViNE simulations are compared against previously used simplified beamline models implemented in the Monte Carlo N-Particle (MCNP) code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Optical Simulations for the VENUS Neutron Imaging Instrument

The VENUS Neutron Imaging instrument at the Spallation Neutron Source has gone through a multitude of optical design changes since its original conception. The goal of this report is to quantify the performance of the most recent optical design and provide insight into potential improvements to this design as needed to ensure optimal performance of the instrument. The results will come in the form of a refined and well developed simulation that provides as best a representation of the performance of the instrument as reasonably achievable. This simulation will be available in a repository alongside relevant simulation output needed to inform any future decisions on the design of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume 4: Detection Systems and Ultra-Cold Neutrons

As part of the Sustaining and Enhancing Nuclear Science (SENSe) initiative at Oak Ridge National Laboratory (ORNL), the prospect of adding new detection systems to support High Flux Isotope Reactor (HFIR) operations and to advance scientific research has prompted many ideas and discussions regarding potential features, configurations, locations, and applications. A working group of ORNL staff members was organized to further develop the concepts and recommending one or more configurations to best support future HFIR operations and scientific capacities and to provide order-of-magnitude cost estimates and timing. The areas of investigation included fast access detection systems, non-scattering beamline instruments, shielded detection instruments, and an ultracold neutron source. In each case, the focus was to develop world leading capabilities that would be unmatched by any other facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incident beam simulations for the CNCS instrument

This data set contains incident beam simulations for the 100 most frequently used configurations of the cold neutron chopper spectrometer (CNCS) instrument at the Spallation Neutron Source. A mcpl output was placed 0.2 m upstream of the sample position. Each file provides enough events to sufficiently sample the beam profile and intensity incident on the sample for that configuration. They can then be used for sample simulations.

47 OTHER INSTRUMENTATION↗

Machine Learning assisted optimization and parameter space exploration dataset of spin ice Hamiltonian

This repository contains both simulated and experimental structure factor data for the data challenge involving the inverse scattering problem. The simulated data were generated during a machine-learning-assisted optimization routine described in ref[1]. The experimental structure factor was measured on a rare-earth oxide, Dy2Ti2O7 using diffuse neutron scattering from time-of-flight techniques on the CORELLI instrument at the Spallation Neutron Source, Oak Ridge National Laboratory. A Metropolis Monte Carlo code implemented to run in a High-performance computing setting was used to calculated simulated structure factors for the spin-ice Hamiltonian at 680 mK, which is the same temperature as for the experimental data. The total size of all the files in this repository is 5.12 GB. A detailed description of the files is given below. ExperimentalData_630mK.dat – A linearized version of 3-dimensional experimental data of size 61×81×21. This data was processed to remove an estimation of non-magnetic background, including nuclear scattering signal and instrumentation background. Parameters.dat – 6700 samples were evaluated over the 4-dimensional parameter space (J_1, J_2, J_3 and J_(3^' )). There is an additional parameter, D in the spin Hamiltonian to mimic the dipolar interaction between magnetic ions. However, this parameter, D was fixed to a value determined by prior work. This file contains five columns for the parameters J_1, J_2, J_3, J_(3^' ) and D respectively. 3D_Simulation_Data.dat – The simulated structure factor, S(Q) data are included in this file. Each raw contains a linearized array of 3D volumes of S(Q) calculated for the parameter set given in the corresponding row of the file Parameters.dat. The size of the volume data was matched to the experimental data. Qx(h,-h,0).dat, Qy(k,k,-2k).dat, Qz(l,l,l).dat – These files contain the h, k, and l values along with the reciprocal vectors [h,-h,0], [k,k,-2k] and [l,l,l] respectively.

36 MATERIALS SCIENCE↗

The development of the NNBAR experiment

The NNBAR experiment for the European Spallation Source will search for free neutrons converting to antineutrons with a sensitivity improvement of three orders of magnitude compared to the last such search. This paper describes progress towards a conceptual design report for NNBAR. The design of a moderator, neutron reflector, beamline, shielding and annihilation detector is reported. The simulations used form part of a model which will be used for optimisation of the experiment design and quantification of its sensitivity.

47 OTHER INSTRUMENTATION↗