Search NASA⌕ Search

SEARCH · Search NASA

Results for “insulative performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Liquefaction and Storage of In-Situ Oxygen on the Surface of Mars

The In-Situ production of propellants for Martian and Lunar missions has been heavily discussed since the mid 1990's. One portion of the production of the propellants is the liquefaction, storage, and delivery of the propellants to the stage tanks. Two key technology development efforts are required: large refrigeration systems (cryocoolers) to perform the liquefaction and high performance insulation within a soft vacuum environment. Several different concepts of operation may be employed to liquefy the propellants based on how and where these two technologies are implemented. The concepts that were investigated include: using an accumulator tank to store the propellant until it is needed, liquefying in the flow stream going into the tank, and liquefying in the flight propellant tank itself. The different concept of operations were studied to assess the mass and power impacts of each concept. Additionally, the trade between insulation performance and cryocooler mass was performed to give performance targets for soft vacuum insulation development. It was found that liquefying within the flight propellant tank itself adds the least mass and power requirements to the mission.

Cryogenic Fluid Management↗

Basic performance of a multilayer insulation system containing 20 to 160 layers

An experimental investigation was conducted to determine the thermal effectiveness of an aluminized Mylar-silk net insulation system containing up to 160 layers. The experimentally measured heat flux was compared with results predicted by using (1) a previously developed semi-empirical equation and (2) an effective-thermal-conductivity value. All tests were conducted at a nominal hot-boundary temperature of 294 K (530 R) with liquid hydrogen as the heat sink. The experimental results show that the insulation performed as expected and that both the semi-empirical equation and effective thermal conductivity of a small number of layers were adequate in predicting the thermal performance of a large number of layers of insulation.

Stochl, R. J.↗

Characterization of Internal Insulation Thermal Performance

A test campaign was performed to build an SRM-insulation-material thermal-performance database using MSFC’s Solid Fuel Torch that could be leveraged to enhance understanding of the relationship between ablation rates and internal-environment parameters and improve insulation performance predictions. Seven hot-fire tests were performed along with data analysis that revealed the thermal performance differences among the tested materials. Functional Data Analysis was employed to create a model of material ablation rate as a function of six covariates. The relative importance of several environmental parameters was indicated, and the gaps in the operational space covered by the database were identified.

Ablation↗

Thermodynamic performance measure for cryogenic vessel insulation

Commonly encountered 'passive' insulation has been improved in recent years using 'dynamic'insulation based on closed cycle cryocoolers attached to photon shields. The paper presents a novel insulation performance measure based on ideal thermodynamic limits. Each floating insulation package has a unique value. In contrast real vessels with vent tube and supports are characterized by an 'effectiveness' less than unity.

Chen, W. E. W.↗

Panelized high performance multilayer insulation

Multilayer insulation coverings with low conductivity foam spacers are interleaved with quarter mil aluminized polymer film radiation shields to cover flight type liquid hydrogen tankage of space vehicles with a removable, structurally compatible, lightweight, high performance cryogenic insulation capable of surviving extended space mission environments.

Burkley, R. A.↗

Thermal Protection Systems for Aerospace Vehicles During Atmospheric Entry

Atmospheric entry and need for thermal protection systems (TPS) is discussed. Ceramic insulations for use as passive TPS are described. Different modes of heat transfer in ceramic insulation are described, and a thermal model is presented. Figures of merit for insulation performance are described and various methods for improving insulation performance are presented.

thermal protection system↗

Space Shuttle Orbiter - Reusable surface insulation flight performance

The first two flights of the Space Shuttle Orbiter have provided the initial data required for operational certification of the Thermal Protection System (TPS). The flight performance characteristics of the TPS reusable surface insulation (RSI) will be discussed. The discussion will be based on post-flight inspections of the RSI and post-flight interpretations of the flight instrumentation data. The flights to date indicate that the thermal and mechanical design requirements for the RSI system were met or exceeded.

Dotts, R. L.↗

Modeling the Gas Dynamics Environment in a Subscale Solid Rocket Test Motor

Subscale test motors are often used for the evaluation of solid rocket motor component materials such as internal insulation. These motors are useful for characterizing insulation performance behavior, screening insulation material candidates and obtaining material thermal and ablative property design data. One of the primary challenges associated with using subscale motors however, is the uncertainty involved when extrapolating the results to full-scale motor conditions. These uncertainties are related to differences in such phenomena as turbulent flow behavior and boundary layer development, propellant particle interactions with the wall, insulation off-gas mixing and thermochemical reactions with the bulk flow, radiation levels, material response to the local environment, and other anomalous flow conditions. In addition to the need for better understanding of physical mechanisms, there is also a need to better understand how to best simulate these phenomena using numerical modeling approaches such as computational fluid dynamics (CFD). To better understand and model interactions between major phenomena in a subscale test motor, a numerical study of the internal flow environment of a representative motor was performed. Simulation of the environment included not only gas dynamics, but two-phase flow modeling of entrained alumina particles like those found in an aluminized propellant, and offgassing from wall surfaces similar to an ablating insulation material. This work represents a starting point for establishing the internal environment of a subscale test motor using comprehensive modeling techniques, and lays the groundwork for improving the understanding of the applicability of subscale test data to full-scale motors. It was found that grid resolution, and inclusion of phenomena in addition to gas dynamics, such as two-phase and multi-component gas composition are all important factors that can effect the overall flow field predictions.

Eaton, Andrew M.↗

Silica/Polymer and Silica/Polymer/Fiber Composite Aerogels

Aerogels that consist, variously, of neat silica/polymer alloys and silica/polymer alloy matrices reinforced with fibers have been developed as materials for flexible thermal-insulation blankets. In comparison with prior aerogel blankets, these aerogel blankets are more durable and less dusty. These blankets are also better able to resist and recover from compression . an important advantage in that maintenance of thickness is essential to maintenance of high thermal-insulation performance. These blankets are especially suitable as core materials for vacuum- insulated panels and vacuum-insulated boxes of advanced, nearly seamless design. (Inasmuch as heat leakage at seams is much greater than heat leakage elsewhere through such structures, advanced designs for high insulation performance should provide for minimization of the sizes and numbers of seams.) A silica/polymer aerogel of the present type could be characterized, somewhat more precisely, as consisting of multiply bonded, linear polymer reinforcements within a silica aerogel matrix. Thus far, several different polymethacrylates (PMAs) have been incorporated into aerogel networks to increase resistance to crushing and to improve other mechanical properties while minimally affecting thermal conductivity and density. The polymethacrylate phases are strongly linked into the silica aerogel networks in these materials. Unlike in other organic/inorganic blended aerogels, the inorganic and organic phases are chemically bonded to each other, by both covalent and hydrogen bonds. In the process for making a silica/polymer alloy aerogel, the covalent bonds are introduced by prepolymerization of the methacrylate monomer with trimethoxysilylpropylmethacrylate, which serves as a phase cross-linker in that it contains both organic and inorganic monomer functional groups and hence acts as a connector between the organic and inorganic phases. Hydrogen bonds are formed between the silanol groups of the inorganic phase and the carboxyl groups of the organic phase. The polymerization process has been adapted to create interpenetrating PMA and silica-gel networks from monomers and prevent any phase separations that could otherwise be caused by an overgrowth of either phase. Typically, the resulting PMA/silica aerogel, without or with fiber reinforcement, has a density and a thermal conductivity similar to those of pure silica aerogels. However, the PMA enhances mechanical properties. Specifically, flexural strength at rupture is increased to 102 psi (=0.7 MPa), about 50 times the flexural strength of typical pure silica aerogels. Resistance to compression is also increased: Applied pressure of 17.5 psi (=0.12 MPa) was found to reduce the thicknesses of several composite PMA/silica aerogels by only about 10 percent.

Ou, Danny↗

Space shuttle Production Verification Motor 1 (PV-1) static fire

All inspection and instrumentation data indicate that the PV-1 static test firing conducted 18 Aug. 1988 was successful. With the exception of the intentionally flawed joints and static test modifications, PV-1 was flight configuration. Fail-safe flaws guaranteeing pressure to test the sealing capability of primary O-rings were included in the aft field joint, case-to-nozzle joint, and nozzle internal Joint 5. The test was conducted at ambient conditions, with the exception of the field joints and case/nozzle joints which were maintained at a minimum of 75 F. Ballistics performance values were within specification requirements. The PV-1 motor exhibited chamber pressure oscillations similar to previously tested Space Shuttle redesigned solid rocket motors, particularly QM-7. The first longitudinal mode oscillations experienced by PV-1 were the strongest ever measured in a Space Shuttle motor. Investigation into this observation is being conducted. Joint insulation performed as designed with no evidence of gas flow within unflawed forward field joints. The intentionally flawed center and aft case field joint insulation performance was excellent. There was no evidence of hot gas past the center field joint capture feature O-ring, the case-to-nozzle joint primary O-ring, or the aft field joint primary O-ring. O-ring seals and barriers with assured pressure at the flaws showed erosion and heat effect, but all sealed against passage of hot gases with the exception of the aft field joint capture feature O-ring. There was no evidence of erosion, heat effect, or blowby on any O-ring seals or barriers at the unflawed joints. Nozzle performance was nominal with typical erosion. Post-test examination revealed that the forward nose ring was of the old high performance motor design configuration with the 150-deg ply angle. All nozzle components remained intact for post-test evaluation. The thrust vector control system operated correctly. The water deluge system, CO2 quench, and other test equipment performed as planned during all required test operations.

Source record↗