Search NASA⌕ Search

SEARCH · Search NASA

Results for “insulative performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Surfactant templated biogenic nanoporous silica thermal insulation composite

Carbon-sequestration biogenic insulation materials offer a promising solution for sustainable and energy-efficient buildings. However, minimizing energy-intensive manufacturing processes and ensuring a uniform microstructure are essential to achieve widespread application. In this work, we introduce cetyltrimethylammonium bromide (CTAB) surfactant as both synthesis and dispersion template for nanoporous silica to create biogenic straw-based thermal insulation composites. As the amount of nanoporous silica increases to 72 wt%, the elastic insulation composite dried using the solvent exchange method exhibits a density of 0.058 g cm –3 , a thermal conductivity of 30.3 mW m –1 K –1 and a flexural modulus of 3.96 MPa, while demonstrating materials circularity and fire retardance. The use of CTAB surfactant effectively captures nanoporous silica, preventing its loss during manufacturing and enhancing the homogeneity and dispersion of the silica within the composite. In addition, the results show that the ethanol solvent exchange drying at ambient conditions provides the optimum thermal insulation performance with less energy consumption compared to freeze-drying.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Porous Ceramics With Foaming Agent

The macro-porous ceramics has promising durability and thermal insulation performance. As porous ceramics find more and more applications across many industries, a cost-effective and scalable additive manufacturing technique for fabricating macro-porous ceramics is highly desirable. Herein, we reported a facile additive manufacturing approach to fabricate porous ceramics and control the printed porosity. Several printable ceramic inks were prepared, and the foaming agent was added to generate gaseous bubbles in the ink, followed by the direct ink writing and the ambient-pressure and room-temperature drying to create the three-dimensional geometries. In this work, a set of experimental studies were performed to optimize the printing quality. The results revealed the optimal process parameters for printing the foamed ceramic ink with a high spatial resolution and fine surface quality. Varying the concentration of the foaming agent enables the controllability of the structural porosity. The maximum porosity can reach 85%, with a crack-free internal porous structure. The tensile tests showed that the printed macro-porous ceramics possessed enhanced durability with the addition of fiber. With a high-fidelity three-dimensional (3D) printing process and the precise controllability of the porosity, we showed that the printed samples exhibited a remarkably low thermal conductivity and durable mechanical strength.

36 MATERIALS SCIENCE↗

Thermochemical characterization of intumescent materials and their application in FEM models using Aria

Intumescent materials are in wide use as protective coatings in fire protection or thermal management applications. These materials undergo chemical reactions occurring from approximately 300°C to 900°C, which outgas and expand the material, providing an appreciable increase in insulative performance. However, the complicated chemical mechanisms and large changes in materials properties complicate the incorporation of these materials into predictive thermal models. This document serves to outline the thermochemical characterization of select intumescent materials, the extraction of relevant parameters, and the incorporation of these parameters into the ChemEQ reaction model implemented in Aria. This work was performed in 2016 and documented in a draft SAND report in March 2017. In 2022, the draft SAND report was discovered and put through R&A.

36 MATERIALS SCIENCE↗

Measured Moisture Performance of Sealed and Insulated Attics with Permeable Insulation In California Homes

This study performed detailed thermal and moisture measurements in two homes in Fresno and Clovis, California with sealed attics insulated with glass fiber insulation to determine moisture performance in inland California climates. Data were recorded once every minute for more than a year in each home to allow detailed observation of time-varying moisture and thermal conditions. Moisture measurements were taken at multiple locations in each attic and included wood moisture, surface condensation and surface relative humidity. The results showed that there are strong solar-driven diurnal cycles in attic wood and air moisture content, as well as longer-term seasonal and annual variations. Mold growth was obdserved on the North roof deck in one of the two homes even in this sunny dry climate with attics built in compliance with California building codes that specifically address sealed and insulated attics with vapor-permeable insulation. We investigated moisture stratification in the attic and found that, although there is stratification during sunny daytime hours, this was not when wood moisture content, surface humidity or surface condensation are high. Therefore, other moisture transport mechanisms are acting to increase moisture levels near the roof peak. Finally, our measurements also showed that the attic with the highest measured moisture levels did not have any mold growth, while mold was visually observed in the attic whose measurements indicted little or no concern, indicating that the state-of-the-art in moisture measurement and mold growth prediction in building assemblies may be insufficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long term performance of vacuum insulation panels integrated into building components

Vacuum insulation panels provide much greater resistance to heat transfer than conventional insulation materials, making them ideal for building applications, especially where space is a constraint. Of particular interest is energy retrofits where high insulation values are required with very little or no modifications to existing building envelope elements such as fenestrations and service penetrations. To facilitate the use of vacuum insulation panels (VIPs) in residential and commercial construction, this study investigates the performance of VIPs integrated into polyisocyanurate foam board and vinyl siding after several years of service. Vacuum insulation panels integrated with polyisocyanurate boards were studied in mixed humid and cold climates. The integration of VIPs with vinyl siding was investigated in a mixed humid climate. Periods of service were between two and five years. In all cases, the integrated building components outperformed conventional materials by almost 40 percent during heating and cooling periods. However, the percent reduction in heat gains and losses of the integrated building components decreased with time at a rate between approximately 4% and 10% per year during the service period. In some cases, the rate seems to converge to a steady -state value. Measurements are ongoing to determine if a steady-state value is attained or the panel's insulation value continues to decrease with time. This study is critical in addressing the service life and durability of the building envelope with VIP integrated building components. The effect of these changes will be reviewed in the context of an exterior retrofit.

Aldykiewicz Jr, Antonio↗

Degradation of Insulating Glass Units: Thermal Performance, Measurements and Energy Impacts

Insulating glass unit (IGU) degradation has been studied extensively. However, there is limited understanding of how present durability evaluation standards relate to product lifetime. Furthermore, there is debate on how to quantify performance of installed windows over time to better understand degradation processes. More knowledge on these topics is required to link durability evaluation to product lifetime projections based on energy performance. Energy models provide helpful estimations of total annual building energy consumption. However, most models are based on “as installed” performance of envelope components and fail to account for performance degradation. This can lead to an underestimation of building lifetime energy consumption. A better understanding of the relationship between durability and energy performance can inform integration of degradation dynamics into energy modeling software. This will improve lifetime building energy consumption estimations as well as inform appropriate retrofit strategies and timing. This paper reviews current durability literature, various standards for window performance ratings and weathering methods, existing in situ IGU energy performance measurement techniques, and whole-building energy effects. The challenges and disparities among various studies are analyzed and discussed. The authors hope that further work in this area will lead to the development of improved in situ test methods to assess IGU degradation in the field and link this knowledge to improved energy performance modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Fabrication of Polyisocyanurate Foams toward Significantly Enhanced Thermal Resistivity

Developing high-performance thermal insulation is vital for addressing the ongoing global demand for reduced energy costs. Polyisocyanurate (PIR) foams are commonly used in residential and commercial buildings and in various industrial applications owing to their relatively high thermal insulation properties and fire resistivity. Here, this study aims to further improve the thermal resistivity of PIR foams by (1) incorporating low thermal conductivity blowing agents; (2) tailoring the anisotropy of their cells; (3) tuning polymeric isocyanate quantities; and (4) incorporating a facer barrier, while using steps that easily integrate into current manufacturing processes for PIR foams. The resulting PIR foams exhibit a significant enhancement in thermal resistivity, achieving initial values as high as 8.3 h·ft 2 ·°F/Btu/in., commonly abbreviated as R-8.3/in., which is a 20% improvement compared with that of commercially used PIR foams that achieve approximately R-7/in. The detailed analysis of thermal conductivity measurements, mechanical testing, and morphological characterization elucidates the structure–property relationships. The developed high-performance PIR foams provide a critical pillar for next-generation high-performance insulation, offering promising thermal insulation for buildings and many other applications that have a significant effect on global energy costs.

Anisotropic pores↗

Development and performance evaluation of active insulation systems using solid-state thermal switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs) that dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. However, materials and assembly development still need a cost-effective product that achieves the required performance. Here, in this study, we present the process of developing an AIS that we will install in a test hut for its performance evaluation. Minimum performance criteria of the AIS system are developed based on R-low/R-high ratio, required time and efficiency to switch states, and cost estimates. The following steps during this study are creating the concept to meet the requirements, predicting the performance via simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to environmental chamber tests. The selected approach uses off-the-shelf products to create an AIS that can switch R-value between 0.98 ft 2 ·°F·h/BTU (0.173 m 2 ·K/W) and 5.81 ft 2 ·°F·h/BTU (1.02 m 2 ·K/W) and have a switching time of less than one minute between R-high and R-low.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nanoporous Wood Chips Based Sizable, Robust, and Low-Cost Honeycomb Vacuum Insulation Panels (DOE BENEFIT Final Research Performance Progress Report (RPPR))

Conventional vacuum insulation panels (VIPs) suffer from severe limitations including high cost, vulnerability to perforation, and significant performance degradation over time due to vacuum loss. InventWood Inc. (IW) and partnering teams completely re-engineered the VIP structure by constructing arrays of isolated vacuum-cells to enable limited cutting at designated areas (in between vacuum cells) and reduced consequential vacuum loss due to puncture. The teams also replaced the expensive vacuum insulation core materials with a low-cost commercial wood pulp and recycled long fiber. The wood pulp derived VIP can deliver an overall panel insulation of R15 (<0.01W/m·K) with over 90% thermal resistance retention after cutting (R13.5 overall, R5 along the cut edges). In addition, the vacuum-cell-array design minimizes edge losses, resulting in more durable performance, longer service life (>50 years), and higher R-value per dollar towards a cost target of <$1/ft 2 ·in. It is anticipated that the Nanochip-VIP will attract strong market interest and become an affordable insulation solution for energy efficient buildings and retrofits, leading to significant reductions in energy usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mutually magnetically insulated two-species Brillouin flow

In this work, we use the Brillouin flow analytic framework to examine the physics of Magnetically Insulated Transmission Lines (MITL). Here, we derive a model applicable to any particle species, including both positive and negative ions, in planar and cylindrical configurations. We then show how to self-consistently solve for two-species simultaneously, using magnetically insulated electrons and positive ions as an example. We require both layers to be spatially separated and magnetically insulated (mutually magnetically insulated); for a 7.5 cm gap with a 2 MV bias voltage, this condition requires magnetic fields in excess of 2.73 T. We see a close match between mutually insulated MITL performance and “superinsulated” (high degree of magnetic insulation) electron-only theory, as may be expected for these high magnetic fields. However, the presence of ions leads to several novel effects: (1) Opposite to electron-only theory, total electron currents increase rather than decrease as the degree of magnetic insulation becomes stronger. The common assumption of neglecting electrons for superinsulated MITL operation must be revisited when ions are present—we calculate up to 20× current enhancement. (2) The electron flow layer thickness increases up to double, due to ion space-charge enhancement. (3) The contributions from both ions and electrons to the MITL flow impedance are calculated. The flow impedance drops by over 50% when ions fill the gap, which can cause significant reflections at the load if not anticipated and degrade performance. Additional effects and results from the inclusion of the ion layer are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Models to Predict the Hygrothermal Performance of Equipment and Piping Insulation

The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).

Shrestha, Som↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. This report, Performance of Windows in Walls with Continuous Insulation , explores the common method for installing windows in walls with continuous insulation and presents acceptance criteria for evaluating the performance of windows installed in walls with and without continuous insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Insulated Wall Systems with Exterior Insulation of Polyisocyanurate under Different Facer Materials: Material Characterization and Long-Term Hygrothermal Performance Assessment

The application of exterior insulation in both new construction and retrofits is a common practice to enhance the energy efficiency of buildings. In addition to increased thermal performance, the rigid insulation can serve to keep the sheathing board warm and serve as a water-resistive barrier to keep moisture-related problems due to condensation and wind-driven rain. Polyisocyanurate (PIR) rigid boards have a higher thermal resistance in comparison to other commonly used exterior insulation boards. However, because of its perceived lower permeance, its use as exterior insulation is not very common. In this study, the hygrothermal property of PIR boards with different facer types and thicknesses is characterized. The material data obtained through experimental test and extrapolation is used in a long term hygrothermal performance assessment of a wood frame wall with PIR boards as exterior insulation. Results show that PIR with no facer has the smallest accumulated moisture on the sheathing board in comparison to other insulation boards. Walls with a bigger thickness of exterior insulation perform better when no vapor barrier is used. The PIR exterior insulation supports the moisture control strategy well in colder climates in perfect wall scenarios, where there is no air leakage and moisture intrusion. In cases where there is trapped moisture, the sheathing board has a higher moisture content with PIR boards with both aluminum or fiberglass type facers. An innovative facer material development for PIR boards can help efforts targeting improved energy-efficient and durable wall systems.

36 MATERIALS SCIENCE↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗