Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometer calibrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

An Eigenvector-based Method of Radio Array Calibration and Its Application to the Tianlai Cylinder Pathfinder

We propose an eigenvector-based formalism for the calibration of radio interferometer arrays. In the presence of a strong dominant point source, the complex gains of the array can be obtained by taking the first eigenvector of the visibility matrix. We use the stable principle component analysis (SPCA) method to help separate outliers and noise from the calibrator signal to improve the performance of the method. This method can be applied with poorly known beam model of the antenna, and is insensitive to outliers or imperfections in the data, and has low computational complexity. It thus is particularly suitable for the initial calibration of the array, which can serve as the initial point for more accurate calibrations. We demonstrate this method by applying it to the cylinder pathfinder of the Tianlai experiment, which aims to measure the dark energy equation of state using the baryon acoustic oscillation (BAO) features in the large scale structure by making intensity mapping observation of the redshifted 21~cm emission of the neutral hydrogen (HI). The complex gain of the array elements and the beam profile in the East-West direction (short axis of the cylinder) are successfully obtained by applying this method to the transit data of bright radio sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superperiods in Interference of eÕ3 Laughlin Quasiparticles Encircling Filling 2/5 FractionalQuantum Hall Island

We report experiments in a large, 2.5 {mu}m diameter Fabry-Perot quantum Hall interferometer with two tunneling constrictions. Interference fringes are observed as conductance oscillations as a function of applied magnetic field (the Aharonov-Bohm flux through the electron island) or a global backgate voltage (electronic charge in the island). Depletion is such that in the fractional quantum Hall regime, filling 1/3 current-carrying chiral edge channels pass through constrictions when the island filling is 2/5. The interferometer device is calibrated with fermionic electrons in the integer quantum Hall regime. In the fractional regime, we observe magnetic flux and charge periods 5h/e and 2e, respectively, corresponding to creation of ten e/5 Laughlin quasiparticles in the island. These results agree with our prior report of the superperiods in a much smaller interferometer device. The observed experimental periods are interpreted as imposed by anyonic statistical interaction of fractionally charged quasiparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron density measurements of a field-reversed configuration plasma using a novel compact ultrastable second-harmonic interferometer

A compact high-sensitivity second-harmonic interferometer for line-integrated electron density measurements on a large plasma machine is presented. The device is based on a fiber coupled near-infrared continuous-wave Nd:YAG laser and is remotely controlled. The performances of the instrument are tested on the Irvine field-reversed configuration machine, and a sensitivity of few 10{sup 14} cm{sup -2} in measuring line integrated electron density is demonstrated with a time resolution of a few microseconds. The interferometer is self calibrated, has an impressive stability, and it does not require any further alignment after proper installation. These features make this device a real turn-key system suitable for electron density measurement in large plasma machines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALL TRANSIENTS, ALL THE TIME: REAL-TIME RADIO TRANSIENT DETECTION WITH INTERFEROMETRIC CLOSURE QUANTITIES

We demonstrate a new technique for detecting radio transients based on interferometric closure quantities. The technique uses the bispectrum, the product of visibilities around a closed loop of baselines of an interferometer. The bispectrum is calibration independent, resistant to interference, and computationally efficient, so it can be built into correlators for real-time transient detection. Our technique could find celestial transients anywhere in the field of view and localize them to arcsecond precision. At the Karl G. Jansky Very Large Array (VLA), such a system would have a high survey speed and a 5{sigma} sensitivity of 38 mJy on 10 ms timescales with 1 GHz of bandwidth. The ability to localize dispersed millisecond pulses to arcsecond precision in large volumes of interferometer data has several unique science applications. Localizing individual pulses from Galactic pulsars will help find X-ray counterparts that define their physical properties, while finding host galaxies of extragalactic transients will measure the electron density of the intergalactic medium with a single dispersed pulse. Exoplanets and active stars have distinct millisecond variability that can be used to identify them and probe their magnetospheres. We use millisecond timescale visibilities from the Allen Telescope Array and VLA to show that the bispectrum can detect dispersed pulses and reject local interference. The computational and data efficiency of the bispectrum will help find transients on a range of timescales with next-generation radio interferometers.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Calibration method to characterize the accuracy of phase-shifting point diffraction interferometer

Characterization of measurement accuracy of the phase-shifting point diffraction interferometer (PS/PDI) is usually performed by two-pinhole null test. In this procedure, the geometrical coma and detector tilt astigmatism systematic errors are almost one or two magnitude higher than the desired accuracy of PS/PDI. These errors must be accurately removed from the null test result to achieve high accuracy. Published calibration methods, which can remove the geometrical coma error successfully, have some limitations in calibrating the astigmatism error. In this paper, we propose a method to simultaneously calibrate the geometrical coma and detector tilt astigmatism errors in PS/PDI null test. Based on the measurement results obtained from two pinhole pairs in orthogonal directions, the method utilizes the orthogonal and rotational symmetry properties of Zernike polynomials over unit circle to calculate the systematic errors introduced in null test of PS/PDI. The experiment using PS/PDI operated at visible light is performed to verify the method. The results show that the method is effective in isolating the systematic errors of PS/PDI and the measurement accuracy of the calibrated PS/PDI is 0.0088{lambda} rms ({lambda}= 632.8 nm).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezoelectric Shaker Development for High Frequency Calibration of Accelerometers

Calibration of vibration transducers requires sinusoidal motion over a wide frequency range with low distortion and low cross-axial motion. Piezoelectric shakers are well suited to generate such motion and are suitable for use with laser interferometric methods at frequencies of 3 kHz and above. An advantage of piezoelectric shakers is the higher achievable accelerations and displacement amplitudes as compared to electro-dynamic (ED) shakers. Typical commercial ED calibration shakers produce maximum accelerations from 100 m/s{sup 2} to 500 m/s{sup 2}. Very large ED shakers may produce somewhat higher accelerations but require large amplifiers and expensive cooling systems to dissipate heat. Due to the limitations in maximum accelerations by ED shakers at frequencies above 5 kHz, the amplitudes of the generated sinusoidal displacement are frequently below the resolution of laser interferometers used in primary calibration methods. This limits the usefulness of ED shakers in interferometric based calibrations at higher frequencies.Small piezoelectric shakers provide much higher acceleration and displacement amplitudes for frequencies above 5 kHz, making these shakers very useful for accelerometer calibrations employing laser interferometric measurements, as will be shown in this paper. These piezoelectric shakers have been developed and used at NIST for many years for high frequency calibration of accelerometers. This paper documents the construction and performance of a new version of these shakers developed at NIST for the calibration of accelerometers over the range of 3 kHz to 30 kHz and possibly higher. Examples of typical calibration results are also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-mode fiber, velocity interferometry

In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, we demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats--this interference occurs between the ''recently'' shifted and ''formerly unshifted'' paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multichannel microwave interferometer for the levitated dipole experiment

A four-channel microwave interferometer (center frequency: 60 GHz) has been constructed to measure plasma density profiles in the levitated dipole experiment (LDX). The LDX interferometer has a unique design owing to the unique geometry of LDX. The main design features of the interferometer are: (1) the transmitted beam traverses the plasma entirely in O-mode; (2) the interferometer is a heterodyne system employing two free-running oscillators; (3) four signals of data are received from just on transmitted beam; (4) phase shifts are detected in quadrature. Calibration tests demonstrate that the interferometer measures phase shifts with an uncertainty of approximately 5 deg. Plasma densities in LDX corresponding to phase shifts of up to 5{pi} are routinely and successfully measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validating data analysis of broadband laser ranging

Broadband laser ranging combines spectral interferometry and a dispersive Fourier transform to achieve high-repetition-rate measurements of the position of a moving surface. Telecommunications fiber is a convenient tool for generating the large linear dispersions required for a dispersive Fourier transform, but standard fiber also has higher-order dispersion that distorts the Fourier transform. Imperfections in the dispersive Fourier transform significantly complicate the ranging signal and must be dealt with to make high-precision measurements. Here, we describe in detail an analysis process for interpreting ranging data when standard telecommunications fiber is used to perform an imperfect dispersive Fourier transform. This analysis process is experimentally validated over a 27-cm scan of static positions, showing an accuracy of 50 μm and a root-mean-square precision of 4.7 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in papers Yashchuk et al. (2007), Yashchuk et al. (2008) is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one-dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high performance of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two-dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the Micromap{trademark}-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of Doppler coherence imaging velocity images

Here, a new technique has been developed for absolutely calibrating a Doppler Coherence Imaging Spectroscopy interferometer for measuring plasma ion and neutral velocities. An optical model of the interferometer is used to generate zero-velocity reference images for the plasma spectral line of interest from a calibration source some spectral distance away. Validation of this technique using a tunable diode laser demonstrated an accuracy better than 0.2 km/s over an extrapolation range of 3.5 nm; a two order of magnitude improvement over linear approaches. While a well-characterized and very stable interferometer is required, this technique opens up the possibility of calibrated velocity measurements in difficult viewing geometries and for complex spectral line-shapes.

spectroscopy and imaging↗

A closed-loop phase-locked interferometer for wide bandwidth position sensing

This article describes a position sensitive interferometer with closed-loop control of the reference mirror. A calibrated nanopositioner is used to lock the interferometer phase to the most sensitive point in the interferogram. In this configuration, large low-frequency movements of the sensor mirror can be detected from the control signal applied to the nanopositioner and high-frequency short-range signals can be measured directly from the photodiode. It is demonstrated that these two signals are complementary and can be summed to find the total displacement. The resulting interferometer has a number of desirable characteristics: it is optically simple, does not require polarization or modulation to detect the direction of motion, does not require fringe-counting or interpolation electronics, and has a bandwidth equal to that of the photodiode. Experimental results demonstrate the frequency response analysis of a high-speed positioning stage. The proposed instrument is ideal for measuring the frequency response of nanopositioners, electro-optical components, MEMs devices, ultrasonic devices, and sensors such as surface acoustic wave detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗