Search NASA⌕ Search

SEARCH · Search NASA

Results for “interlaboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

Electrophoretic mobilities of cultured human embryonic kidney cells in various buffers

Data on the electrophoretic mobility distributions of cells in the new D-1 buffer and the interlaboratory standardization of urokinase assay methods are presented. A table of cell strains and recent data on cell dispersal methods are also included. It was decided that glycerol in A-1 electrophoretic mobility data on cultured human embryonic kidney cells subjected to electrophoresis in this buffer. The buffer composition is presented.

Source record↗

Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

Lisagor, W. B.↗

A direct time series comparison between the La Jolla and Belfast radiocarbon records

For many years it has been widely assumed that the variations in the level of atmospheric carbon-14 were due to statistical fluctuations arising from experimental error. This is understandable since the signal/noise ratio is very low and the time sequences representing the variations are strongly stochastic. Interlaboratory comparisons show that baseline variations in the absolute value of the carbon-14 concentration do exist. However, assuming linearity, the delta 14C values are independent of these. The importance of assessing the quantitive reality of the delta 14C values is based upon their expression of the interplanetary cosmic ray source function, because in the range of 100 to 1000 year periods, there appears to be no evidence that the Earth's magnetic field is the source modulating function. Therefore the modulation is either due to changes in the solar atmosphere propagated out into the solar wind, or extra-heliospheric pressure effects, but these appear to be unlikely for the periods noted here. The recent availability of the new high quality Belfast time sequence of delta 14C now permits a simple mutual assessment of the several sequences which are available. Since the La Jolla record has been a standard for many years , these two were chosen for a simple comparison. Although differences exist, the close agreement between these two sequences, one carried out on White mountain Bristlecone pines, and the other done using Irish peat bog wood, is striking. This correlation between the two strongly reinforces the statistical view that the delta 14C record is that of real interplanetary modulation of the cosmic ray source leading to the generation of atmospheric 14C.

Sonett, C. P.↗

Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

Domack, M. S.↗

Current activities in standardization of high-temperature, low-cycle-fatigue testing techniques in the United States

The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.

Verrilli, Michael J.↗

Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

Obrien, T. Kevin↗

Accuracy metrics for judging time scale algorithms

Time scales have been constructed in different ways to meet the many demands placed upon them for time accuracy, frequency accuracy, long-term stability, and robustness. Usually, no single time scale is optimum for all purposes. In the context of the impending availability of high-accuracy intermittently-operated cesium fountains, we reconsider the question of evaluating the accuracy of time scales which use an algorithm to span interruptions of the primary standard. We consider a broad class of calibration algorithms that can be evaluated and compared quantitatively for their accuracy in the presence of frequency drift and a full noise model (a mixture of white PM, flicker PM, white FM, flicker FM, and random walk FM noise). We present the analytic techniques for computing the standard uncertainty for the full noise model and this class of calibration algorithms. The simplest algorithm is evaluated to find the average-frequency uncertainty arising from the noise of the cesium fountain's local oscillator and from the noise of a hydrogen maser transfer-standard. This algorithm and known noise sources are shown to permit interlaboratory frequency transfer with a standard uncertainty of less than 10(exp -15) for periods of 30-100 days.

Douglas, R. J.↗

Standardization Activities in TMF Test Methodologies

No standard test practice currently exists for strain-controlled thermomechanical fatigue (TMF) testing. This paper discusses recent activities which lay the foundation for standardization of TMF test methods. Specifically, the paper documents the results of two interlaboratory TMF test programs, identifies key TMF symposia and workshops, and discusses efforts toward drafting a TMF standard test practice.

Verrilli, M. J.↗

A Summary of the International Workshops on Space Solar Cell Calibration and Measurement Techniques

The first two of a planned series of international workshops concerning space solar cell calibration and measurement techniques have been held within the past year. The need for these workshops arose from the increasing complexity of space solar cells coupled with the growing international nature of the market for space cells and arrays. The workshops, jointly sponsored by NASDA, ESA and NASA, have the objective of obtaining international agreement on standardized values for the AM0 spectrum and constant, recommendations for laboratory measurement practices and the establishment of a set of protocols for making interlaboratory comparison measurements. The results of the first two workshops, held in Waikiki, Hawaii, USA in 1994 and Madrid, Spain in 1995, are presented.

Brinker, D. J.↗

NIST Efforts to Quality-Assure Gunpowder Measurements

In the past few years, the National Institute for Standards and Technology (NIST) has been promoting the idea of quantitatively determining the additives in smokeless gunpowder using micellar capillary electrophoresis as a means of investigating the criminal use of hand guns and pipe bombs. As a part of this effort, we have evaluated both supercritical fluid and ultrasonic solvent extractions for the quantitative recovery of nitroglycerin (NG), diphenylamine (DPA), N-nitrosodiphenylamine (NnDPA), and ethyl centralite (EC) from gunpowder. Recoveries were evaluated by repeat extraction and matrix spiking experiments. The final extraction protocol provides greater than 95 percent recoveries. To help other researches validate their own analytical method for additive determinations, NIST is exploring the development of a standard reference material, Additives in Smokeless Gunpowder. The evaluated method is being applied to two double-base (NG-containing) powders, one stabilized with diphenylamine and the other with ethyl centralite. As part of this reference material development effort, we are conducting an interlaboratory comparison exercise among the forensic and military gunpowder measurement community.

MacCrehan, William A.↗

Development of a Reference Dose for Perchlorate: Current Issues and Status

The perchlorate anion (ClO4) is typically manufactured as the ammonium salt. The most common use of ammonium perchlorate is in the aerospace program as a component of solid rocket fuel. The perchlorate anion is exceedingly stable under environmental conditions and has been found in ground and surface waters in CA, NV, UT, AZ, TX, AK, NY, MD, WV and FL. The National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (US EPA) is in the process of developing an oral reference dose (RfD) for perchlorate. An oral RfD is a body-weight-adjusted dose that can be consumed daily over an entire lifetime with the expectation of no adverse health effects. Once developed, the new RfD will be used by US EPA as the basis of a safe-drinking-water level (SDWL) guideline. US EPA and regional regulatory agencies will then jointly or separately propose clean-up action levels for ground and surface waters at contaminated sites. The toxicological database on CIO4- as of March 1997 was determined by an expert peer-review panel to be inadequate for the purpose of deriving an oral RfD. For example, little or no experimental data existed on the subchronic, reproductive, or developmental toxicity of perchlorate. To fill gaps in the toxicological database, eight animal studies were designed by a government-industry consortium that included US EPA and AFRL. These studies were performed in 1997-1998. It has been known for many years that in the thyroid, high doses of perchlorate block the function of iodide by competing for iodide binding sites. Perchlorate was used in the 1950s-60s as a treatment for Graves' disease (a hyperthyroid condition). Because of what was already known about the pharmacological mode of action of perchlorate, specific concerns addressed in the design of the recent animal studies included the potential for developmental toxicity, notably neurological development. Upon review of complete study reports from four of the studies and incomplete data from the other two, US EPA/NCEA issued a document in December 1998 stating that the critical effects were hormone and histology data from the neurodevelopmental/behavioral toxicity study that had been performed in rats; an RfD was proposed based upon the observation of thyroid-follicular-cell hypertrophy in the 5-day-old pups (PND) of dams given perchlorate in drinking water at 0.1 mg/kg-day (the lowest dose tested) in this study. US EPA/NCEA also focused attention on a nonsignificant increase in motor activity observed in 14-day-old male pups in the same study at the same dose. In February 1999, a public workshop was convened at which an external peer-review panel determined that there was still insufficient data to support the development of a RfD. Additional studies were recommended. Since that time a clinical study revealed significant depression of thyroidal uptake of iodide in volunteers receiving potassium perchlorate at 10 mg/day for 14 days. Follow-up studies currently underway include a pathology working-group review of histology slides from the all of the previous studies, a motor activity study similar to the first behavioral study, an additional immunotoxicity study, male and female rat kinetic studies, a hormone interlaboratory study, and an effects study for thyroid and brain in developing rats. These studies are expected to be complete by mid-2000. A clinical study is planned to determine inhibition of iodide uptake and kinetic parameters in humans following 14-day perchlorate ingestion. The kinetics studies will provide data for developing physiologically based pharmacokinetic (PBPK) models for rats and humans needed to establish the RfD.

Pleus, R. C.↗

Reproducibility and Repeatability of Tensile and Low-Cycle Fatigue Properties in Propulsion Grade Hydrogen

Hydrogen has the potential of increased use in the future as an environmentally friendly fuel. It has, however, shown a tendency to embrittle some materials. To be used in a safe manner and to exploit its full potential, it will be necessary to develop a database of material properties in hydrogen environment. The tests needed to produce this data are costly to perform (tensile test cost 25 times more and low cycle fatigue test are 55 times as expensive). Moreover, there is presently a lack of universal test methods to ensure standardized data within the hydrogen community. Each of the industries that work with hydrogen (aerospace, petroleum, fuel cells, etc.) performs tests by their own laboratory-developed methods, thus rendering cross- comparisons of material property data highly questionable. It is extremely important that data generated in a hydrogen environment be done to a standard that reduces variance to a minimum and allows direct comparison of test results from different laboratories. Doing so will assure that all data generated can be used to further our understanding of the hydrogen effects and to make sure components/products designed for hydrogen are the safest and most reliable possible. This paper reviews the results of two 'round-robin' programs conducted by NASA-MSFC. These two programs examined the reproducibility and repeatability of tensile and low-cycle fatigue test results in high-pressure hydrogen environments. The studies indicated that even with the tightest controls available from current commercial standards, the reproducibility (between different laboratories) and repeatability (within a laboratory) results of the tensile tests exhibited five times the variance as in standard ambient air tests. The variance with the LCF tests were on the same order as with air tests, but that was due to the large variation present in the last Interlaboratory air program. The paper concludes with a recommendation for a program that would allow the development of improved test methods, leading to lower variance in the generation of mechanical property data in the future.

Vesely, E. J.↗

DEVELOPMENT OF STANDARDIZED LUNAR REGOLITH SIMULANT MATERIALS

Lunar exploration activities require scientific and engineering studies that use standardized testing procedures and ultimately support flight certification of hardware and the development of technologies for their use on the lunar surface. It is necessary to anticipate the full range of source materials and environmental constraints that are expected on the Moon and Mars, and to evaluate in-situ resource utilization (ISRU) coupled with testing and development. Historical use of lunar simulants has focused on physical aspects of the lunar regolith for landing and transportation activities. Lunar mare simulants MLS-1 and JSC-1 have been developed, but supplies have been exhausted. Renewed emphasis on exploration and ISRU activities requires development of standardized simulant reference materials that are traceable interlaboratory standards for testing and simulate the lunar regolith in terms of physical, chemical, and mineralogical properties. This new generation of lunar regolith simulants must therefore support both technological development and testing methods. These issues were extensively discussed at the 2005 Lunar Regolith Simulant Materials Workshop.

Carpenter, P.↗

Development of Standardized Lunar Regolith Simulant Materials

Lunar exploration requires scientific and engineering studies using standardized testing procedures that ultimately support flight certification of technologies and hardware. It is necessary to anticipate the range of source materials and environmental constraints that are expected on the Moon and Mars, and to evaluate in-situ resource utilization (ISRU) coupled with testing and development. Physical properties of the regolith dominate processes such as excavation and drilling, while chemical properties dominate processes such as elemental extraction. We describe here the development of standardized lunar regolith simulant (SLRS) materials that are traceable interlaboratory standards for testing and technology development. These SLRS materials must simulate the lunar regolith in terms of physical, chemical, and mineralogical properties. A comprehensive simulant development program has been outlined and is in progress. A summary of these issues is contained in the 2005 Workshop on Lunar Regolith Simulant Materials

Carpenter, P.↗

X-ray Mapping of Terrestrial and Extraterrestrial Materials Using the Electron Microprobe

Lunar samples returned from the Apollo program motivated development of the Bence-Albee algorithm for the rapid and accurate analysis of lunar materials, and established interlaboratory comparability through its common use. In the analysis of mineral and rock fragments it became necessary to combine micro- and macroscopic analysis by coupling electron-probe microanalysis (EPMA) with automated stage point counting. A coarse grid that included several thousand points was used, and initially wavelength-dispersive (WDS) and later energydispersive (EDS) data were acquired at discrete stage points using approx. 5 sec count times. A approx 50 micrometer beam diameter was used for WDS and up to 500 micrometer beam diameter for EDS analysis. Average analyses of discretely sampled phases were coupled with the point count data to calculate the bulk composition using matrix algebra. Use of a defocused beam resulted in a contribution from multiple phases to each analytical point, and the analytical data were deconvolved relative to end-member phase chemistry on the fly. Impressive agreement was obtained between WDS and EDS measurements as well as comparison with bulk chemistry obtained by other methods. In the 30 years since these methods were developed, significant improvements in EPMA automation and computer processing have taken place. Digital beam control allows routine collection of x-ray maps by EDS, and stage mapping for WDS is conducted continuously at slew speed and incrementally by sampling at discrete points. Digital pulse processing in EDS systems has significantly increased the throughput for EDS mapping, and the ongoing development of Si-drift detector systems promises mapping capabilities rivaling WDS systems. Spectrum imaging allows a data cube of EDS spectra to be acquired and sophisticated processing of the original data is possible using matrix algebra techniques. The study of lunar and meteoritic materials includes the need to conveniently: (1) Characterize the sample at microscopic and macroscopic scales with relatively high sensitivity, (2) Determine the modal abundance of minerals, and (3) Identify and relocate discrete features of interest in terms of size and chemistry. The coupled substitution of cations in minerals can result in significant variation in mineral chemistry, but at similar average Z, leading to poor backscattered-electron (BSE) contrast discrimination of mineralogy. It is necessary to discriminate phase chemistry at both the trace element level and the major element level. To date, the WDS of microprobe systems is preferred for mapping due to high throughput and the ability to obtain the necessary intensity to discriminate phases at both trace and major element concentrations. It is desirable to produce fully quantitative compositional maps of geological materials, which requires the acquisition of k-ratio maps that are background and dead-time corrected, and which have been corrected by phi(delta z> or an equivalent algorithm at each pixel. To date, turnkey systems do not allow the acquisition of k-ratio maps and the rigorous correction in this manner. X-ray maps of a chondrule from the Ourique meteorite, and a comb-layered xenolith from the San Francisco volcanic field, have been analyzed and processed to extract phase information. The Ourique meteorite presents a challenge due to relatively low BSE contrast, and has been studied using spectrum imaging. X-ray maps for Si, Mg, and FeK(alpha) were used to produce RGB images. The xenolith sample contains sector-zoned augite, olivine, plagioclase, and basaltic glass. X-ray maps were processed using Lispix and ImageJ software to produce mineral phase maps. The x-ray maps for Mg, Ca, and Ti were used with traceback to generate binary images that were converted to RGB images. These approaches are successful in discriminating phases, but it is desirable to achieve the methods that were used on lunar samples 30 years ago on current microprobe systems. Curnt research includes x-ray mapping analysis of the Dalgety Downs chondrite by micro x-ray fluorescence and spectrum imaging, in collaboration with Kenny Witherspoon of IXRF Systems and Dale Newbury of NIST.

Carpenter, P.↗

Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

Luecke, William E.↗

System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

Kim, Hyun-Jung↗

Computer Controlled High Vacuum Gas Purification and Analysis Line

Light stable isotope work requires the handling of gasses such a way that does not alter isotopic composition. To do this, there are a large number of analytical and experimental procedures which involve the use of a vacuum line, numerous “egg timers” and a human hand on a valve. Unfortunately, the human hand is inconsistent and inadvertent small, and commonly large, differences in timing can have a measurable effect on outcomes. We have constructed a computer controlled high-vacuum line to be used as an expandable platform for future experimental and analytical procedures. The vacuum line consists of an electropolished 316 stainless steel system of cryogenic u-traps partitioned by pneumatic valves. The code to operate the line has been developed using the LabView platform and will allow for automated timing, consistent valve opening speed and unattended operation of long analytical procedures. The aim of this project is to address a need in the light stable isotope laboratory for a general-purpose vacuum line for handling and manipulation of gasses. When combined with existing instrumentation it allows for a significant expansion of current analytical capabilities. The system allows for better handling of standards, gas conversion techniques and gas sample collection for interlaboratory comparisons. The basic structure of the line, automation hardware and software were chosen and designed to provide a base for future expansion of the system to incorporate new automated analytical techniques as laboratory instrumentation and analytical needs expand.

High vacuum↗